Heart ; 105(21): 1622-1628, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30077993

RESUMO

OBJECTIVES: This study evaluates the 5-year clinical outcomes of transcatheter mitral valve (MV) repair with the MitraClip device in patients at high risk for MV surgery treated in the Endovascular Valve Edge-to-Edge Repair (EVEREST) II High Risk Study (HRS). METHODS: Patients with mitral regurgitation (MR) 3+ or 4+ and predicted surgical mortality risk ≥12% or surgeon assessment based on prespecified high-risk factors were enrolled. Patients prospectively consented to 5 years of follow-up. RESULTS: At 5 years, clinical follow-up was achieved in 90% of 78 enrolled patients. The rate of postprocedural adverse events declined from 30 days to 1 year follow-up and was stable thereafter through 5 years. Two patients (2.6%) developed mitral stenosis (MS). Two patients underwent MV surgery, including one due to MS. A total of 42 deaths were reported through 5 years. Effectiveness measures at 5 years showed reductions in MR severity to ≤2+ in 75% of patients (p=0.0107), left ventricular (LV) end-diastolic volume (-38.2 mL; 95% CI -55.0 to -21.4; p<0.0001) and LV end-systolic volume (-14.6 mL; 95% CI -27.7 to -1.5; p=0.0303) compared with baseline. The New York Heart Association (NYHA) functional class improved from baseline to 5 years (p<0.005), and septal-lateral annular dimensions remained stable with no indication of mitral annular dilation through 5 years. CONCLUSIONS: The EVEREST II HRS demonstrated long-term safety and efficacy of MitraClip in high-surgical-risk patients through 5 years. The observed mortality was most likely a consequence of the advanced age and comorbidity profile of the enrolled patients, while improvements in NYHA class in surviving patients were durable through long-term follow-up. TRIAL REGISTRATION NUMBER: NCT01940120.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Medição de Risco/métodos , Idoso , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Incidência , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo , Estados Unidos/epidemiologia , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA