Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 45(8): 2226-2241, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31128769

RESUMO

This work presents an affordable and easily customizable methodology for phantom manufacturing, which can be used to mimic different anatomic organs and structures. This methodology is based on the use of polyvinyl alcohol-based cryogels as a physical substitute for biologic soft tissues and of 3-D printed polymers for hard tissues, moulding and supporting elements. Thin and durable soft-tissue mimicking layers and multilayer arrangements can be obtained using these materials. Special attention was paid to the acoustic properties (sound speed, attenuation coefficient and mechanical impedance) of the materials developed to simulate soft tissues. These properties were characterized as a function of the additives concentration (propylene-glycol and alumina particles). The polyvinyl alcohol formulation proposed in this work is stable over several freeze-thaw cycles, allowing the manufacturing of multilayer materials with controlled properties. The manufacturing methodology presented was applied to the development of a phantom for high-frequency cranial ultrasonography in infants. This phantom was able to reproduce the main characteristics of the ultrasound images obtained in neonates through the anterior fontanel, down to 8-mm depth.


Assuntos
Criogéis , Ecoencefalografia/métodos , Imagens de Fantasmas , Álcool de Polivinil , Impressão Tridimensional , Materiais Biomiméticos , Humanos , Recém-Nascido , Polímeros
2.
Artigo em Inglês | MEDLINE | ID: mdl-20875988

RESUMO

In this work, a high-resolution imaging method for the inspection of isotropic plate-like structures using linear arrays and Lamb waves is proposed. The evaluation of these components is limited by the low dynamic range resulting from main lobe and side lobe field patterns, and from the narrowband nature of the Lamb waves. Based on a full matrix array, synthetic aperture technique using all emitter-receiver combinations, different images from the same object are obtained by using different apodization coefficients, which are related to a trade-off between main lobe width and relative side lobe level. Several image compounding strategies have been tested and a new algorithm, based on apodization and polarity diversities between signals, is proposed. However, some effects, such as the dead zone close to the array and reverberations caused by interactions of the wavefront and defects, still limit the quality of the images. The use of spatial diversity, obtained by an additional array, introduces complementary information about the defects and improves the results of the proposed algorithm, producing high-resolution, high-contrast images. Experimental results are shown for a 1-mm-thick isotropic aluminum plate with artificial defects using linear arrays formed by 30 piezoelectric elements, with the low dispersion symmetric mode S0 at the frequency of 330 kHz.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia/instrumentação , Ultrassonografia/métodos
3.
Artigo em Inglês | MEDLINE | ID: mdl-18986872

RESUMO

This work presents the implementation of the ultrasonic shear reflectance method for viscosity measurement of Newtonian liquids using wave mode conversion from longitudinal to shear waves and vice versa. The method is based on the measurement of the complex reflection coefficient (magnitude and phase) at a solid-liquid interface. The implemented measurement cell is composed of an ultrasonic transducer, a water buffer, an aluminum prism, a PMMA buffer rod, and a sample chamber. Viscosity measurements were made in the range from 1 to 3.5 MHz for olive oil and for automotive oils (SAE 40, 90, and 250) at 15 and 22.5 degrees C, respectively. Moreover, olive oil and corn oil measurements were conducted in the range from 15 to 30 degrees C at 3.5 and 2.25 MHz, respectively. The ultrasonic measurements, in the case of the less viscous liquids, agree with the results provided by a rotational viscometer, showing Newtonian behavior. In the case of the more viscous liquids, a significant difference was obtained, showing a clear non-Newtonian behavior that cannot be described by the Kelvin-Voigt model.


Assuntos
Acústica , Algoritmos , Modelos Químicos , Nefelometria e Turbidimetria/métodos , Óleos/química , Espectrografia do Som/métodos , Simulação por Computador , Óleos/análise , Espalhamento de Radiação , Sensibilidade e Especificidade , Viscosidade
SELEÇÃO DE REFERÊNCIAS