RESUMO
BACKGROUND: Lutein and zeaxanthin are suggested micronutrient supplements to prevent the progression of age-related macular degeneration (AMD), a leading cause of blindness worldwide. To monitor the levels of lutein/zeaxanthin in the macula, macular pigment optical density (MPOD) is measured. A commercially available device (MPSII®, Elektron Technology, Switzerland), using technology based on heterochromatic flicker photometry, can measure both absolute and estimated values of MPOD. However, whether the estimated value is applicable to Asian individuals and/or AMD patients remains to be determined. METHODS: The absolute and estimated values of MPOD were measured using the MPSII® device in 77 participants with a best-corrected visual acuity (BCVA) > 0.099 (logMAR score). RESULTS: The studied eyes included 17 young (20-29 years) healthy, 26 aged (>50 years) healthy, 18 aged and AMD-fellow, and 16 aged AMD eyes. The mean BCVA among the groups were not significantly different. Both absolute and estimated values were measurable in all eyes of young healthy group. However, absolute values were measurable in only 57.7%, 66.7%, and 43.8%, of the aged healthy, AMD-fellow, and AMD groups, respectively, and 56.7% of the eyes included in the 3 aged groups. In contrast, the estimated value was measurable in 84.6%, 88.9% and 93.8% of the groups, respectively, and 88.3% of eyes in the pooled aged group. The estimated value was correlated with absolute value in individuals from all groups by Spearman's correlation coefficient analyses (young healthy: R2 = 0.885, P = 0.0001; aged healthy: R2 = 0.765, P = 0.001; AMD-fellow: R2 = 0.851, P = 0.0001; and AMD: R2 = 0.860, P = 0.013). Using the estimated value, significantly lower MPOD values were found in aged AMD-related eyes, which included both AMD-fellow and AMD eyes, compared with aged healthy eyes by Student's t-test (P = 0.02). CONCLUSIONS: Absolute, in contrast to estimated, value was measurable in a limited number of aged participants; however, it was correlated with estimated value both in young and aged Asian populations with or without AMD. These results may inform future clinical studies investigating the measurement of MPOD in understanding the role of macular pigments in the pathogenesis of AMD.
Assuntos
Povo Asiático , Luteína/metabolismo , Degeneração Macular/metabolismo , Retina/fisiologia , Zeaxantinas/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
Visual field defects interfere with free actions and influence the quality of life of patients with retinitis pigmentosa; the prevalence of this disease is increasing in aging societies. Patients with progressive disease may require visual aids; however, no such devices are currently available. We utilized a retinal projection eyewear system, QD laser eyewear, which includes a projector inside the spectacle frame, to draw the image taken by a connected portable camera with a wide field lens. The images are projected onto the retina using a Maxwellian view optical system, which is not influenced by refractive error or the amount of incident light. Goldmann perimetry and figure recognition tests with the QD laser eyewear showed increased visual field areas and angles, and shortened the time for recognition of the number of figures in a sheet, in a limited visual field model that we developed by using a pin-hole system to simulate the tunnel vision of retinitis pigmentosa in 19 healthy adults. The device supported the quality of vision. Additionally, the visual field defect model used in healthy adults was useful for validating the device in the development stage of the study, to clarify both advantages and future goals for improving the device.