Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Vasc Surg ; 80(2): 344-354, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38552884

RESUMO

OBJECTIVE: This study aims to report the efficacy and safety of double-fenestrated physician-modified endovascular grafts (PMEGs) for total aortic arch repair with at least 3 years of follow-up. METHODS: All consecutive patients with a pathological aortic arch who underwent aortic arch repair combined with a homemade double-fenestrated stent graft from 2017 to 2020 were reviewed. RESULTS: 74 patients were treated for pathological arch conditions with a double-fenestrated PMEG. Of these, 81% were male, the mean age was 69.9 years, and 59% were classified as American Society of Anesthesiology 3 or 4. Thirty-five percent were treated for a postdissection aneurysm, 36% for a degenerative aneurysm, and 14% for acute type B dissection. Fifteen percent had supra-aortic trunk dissection. Fenestration on the subclavian artery was performed in 96%; if not, a carotid-subclavian bypass was carried out. Technical success was 100%. The proximal landing zone is consistently in zone 0. Early outcomes revealed a 3% occurrence of type 1 endoleak, which was successfully treated by prompt reintervention. One retrograde dissection occurred, and one patient died from hemorrhage on an iliac conduit. A 5% stroke rate was reported. During long-term follow-up (mean time 40.7 months), one type 1 endoleak appeared and was successfully treated; no type 2 or type 3 endoleak requiring intervention occurred. No stent fractures or migrations were reported. Four percent of patients required reintervention, but no surgical conversion to open surgical repair was needed on the aortic arch. No patient died from a cause related to the main procedure. CONCLUSIONS: Total aortic arch repair with double-fenestrated PMEGs is associated with acceptable early and midterm major morbidity and mortality. It is suitable for the main aortic pathologies. Moreover, it is easily available for emergency situations.


Assuntos
Aorta Torácica , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Complicações Pós-Operatórias , Desenho de Prótese , Stents , Humanos , Masculino , Idoso , Feminino , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Tempo , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Dissecção Aórtica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Fatores de Risco
2.
J Surg Res ; 295: 222-230, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38039727

RESUMO

INTRODUCTION: Study aims were to evaluate the elastic properties of vascular substitutes frequently used for pulmonary artery (PA) replacement, and then to compare their compliance and stiffness indexes to those of human PA. METHODS: A bench-test pulsatile flow experiment was developed to perfuse human cadaveric vascular substitutes (PA, thoracic aorta, human pericardial conduit), bovine pericardial conduit, and prosthetic vascular substitutes (polytetrafluorethylene and Dacron grafts) at a flow and low pulsed pressure mimicking pulmonary circulation. Intraluminal pressure was measured. An ultrasound system with an echo-tracking function was used to monitor vessel wall movements. The diameter, compliance, and stiffness index were calculated for each vascular substitute and compared to the human PA at mean pressures ranging from 10 to 50 mmHg. RESULTS: The compliance of the PA and the thoracic aorta were similar at mean physiological pressures of 10 mmHg and 20 mmHg. The PA was significantly less compliant than the aorta at mean pressures above 30 mmHg (P = 0.017). However, there was no difference in stiffness index between the two substitutes over the entire pressure range. Compared to the PA, human pericardial conduit was less compliant at 10 mmHg (P = 0.033) and stiffer at 10 mmHg (P = 0.00038) and 20 mmHg (P = 0.026). Bovine pericardial conduit and synthetic prostheses were significantly less compliant and stiffer than the PA for mean pressures of 10, 20, and 30 mmHg. There were no differences at 40 and 50 mmHg. CONCLUSIONS: Allogenic arterial grafts appear to be the most suitable vascular substitutes in terms of compliance and stiffness for PA replacement.


Assuntos
Artéria Pulmonar , Humanos , Animais , Bovinos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Ultrassonografia , Fluxo Pulsátil
3.
J Endovasc Ther ; : 15266028241258401, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898697

RESUMO

INTRODUCTION: The treatment of acute type B aortic dissection (ATBAD) is currently a challenge for vascular surgeons, because of the early morbidity and mortality rates and the high risk of late aortic events up to 50% at 5 years. This study presents the initial outcomes of ATBAD treatment using optimal medical therapy alone or combined with proximal entry tear stent-graft coverage. Additionally, it provides an analysis of the evolution of the aortic diameter and its clinical consequences during the chronic phase in each group. MATERIALS AND METHODS: Conducted as a retrospective, single-center study, we enrolled all consecutive ATBAD patients (n=130) treated between 2008 and 2020. The primary analysis studies the entire patient cohort based on their initial management approach, namely, medical treatment alone for uncomplicated ATBAD (n=67) or combined with stent-graft entry tear coverage (n=63). We also conducted a subgroup analysis to investigate factors associated with disease progression in the medical management group. RESULTS: Median follow-up was 29.5 months. During this time aneurysmal evolution was observed in: 42.4% of cases in the medical group compared with 21.8% in the stent-graft group, primarily affecting the thoracic aorta. The stent-graft group exhibited significant aortic remodeling, with a decrease in false lumen (FL) and thoracic aortic diameters. Initial aortic diameter ≥40 mm and FL ≥22 mm were independent risk factors for aneurysmal degeneration. Five-year survival was consistent at 76.1% in both groups. CONCLUSION: This study confirms the safety and efficacy of stent-graft entry tear coverage for ATBAD. Initial thoracic endovascular aortic repair (TEVAR) appears to reduce late aortic events by promoting aortic remodeling. Considering TEVAR's safety and potential to prevent late aortic complications, it may be considered for uncomplicated ATBAD patients with an initial aortic diameter ≥40 mm or an FL ≥22 mm. CLINICAL IMPACT: This study validates the efficacy and safety of using endovascular stent grafts to seal the proximal entry tear in cases of acute type B aortic dissections, compared to optimal medical therapy. Aortic remodelling significantly benefits from endovascular stent graft coverage of the proximal entry tear. Given the heightened risk of late aortic events observed in the medical therapy cohort, there appears to be a necessity for including endovascular interventions in the management of uncomplicated acute type B aortic dissections, particularly when aortic diameter is ≥40 mm and false lumen diameter is ≥22 mm.

4.
J Endovasc Ther ; 30(1): 151-155, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35094606

RESUMO

PURPOSE: The purpose of the study was to demonstrate the feasibility of urgent endovascular treatment of a traumatic aortic isthmus rupture in a patient with an aberrant right subclavian artery. CASE REPORT: A 23-year-old man was admitted to a regional trauma center after a motor vehicle collision and found to have cerebral trauma and a large pseudoaneurysm of the aortic arch. Trauma computed tomography (CT) identified a blunt traumatic thoracic aortic injury with an aortic false aneurysm in the context of an aberrant right subclavian artery. A hybrid repair was performed with bilateral subclavian carotid bypasses and a double fenestrated physician-modified stent graft. The patient had an uneventful postoperative course. Postoperative CT scan showed sealing of the aortic arch rupture and patency of all the supra-aortic trunks. CONCLUSION: Endovascular repair of blunt traumatic thoracic aortic injury is considered first-line therapy. Aortic arch anomalies add complexity to treatment. This report demonstrates that a hybrid strategy with bilateral carotid-axillary bypasses and homemade double fenestrated endograft of the aortic arch is a valuable approach for this challenging emergency in the context of an aberrant right subclavian artery.


Assuntos
Aneurisma da Aorta Torácica , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Adulto Jovem , Adulto , Prótese Vascular , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Procedimentos Endovasculares/métodos , Stents , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia
5.
J Endovasc Ther ; : 15266028231215779, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38049943

RESUMO

OBJECTIVE: The aim of this study is to report the efficiency and safety of single-fenestrated physician-modified endografts (PMEGs) in zone 2 aortic arch pathologies with at least 3 years of follow-up. METHODS: All consecutive patients with a pathological aortic arch who underwent aortic repair combined with homemade single-fenestrated stent-graft from 2015 to 2020 were reviewed. The patients with a target vessel different from the left subclavian artery (LSA) were excluded. RESULTS: A total of 63 patients were treated for a pathological arch in zone 2 with a single-fenestrated PMEG. 73% were male, and the mean age was 65 years old. 25% were treated for a degenerative aneurysm, 19% for a post dissection aneurysm and 24% for an acute type B dissection. 52% of the patients were treated as an emergency and half of those for an aortic rupture. The LSA fenestration was stented in 70%. During 30 days of follow-up, 2 strokes (3%) were reported, 6 patients (10%) died with 4 of those treated for aortic rupture and 1 had a retrograde aortic dissection. During at least 3 years of follow-up (median 49 months), no reintervention was needed for endoleaks, there was no stent fracture or stent migration. No patient died from an aortic cause. Subgroup analysis comparing the endovascular treatment for various aortic pathologies did not find significant differences in death rate or comorbidity including stroke. When comparing emergent and elective aortic repair, operating time was similar (64 vs 65 minutes), and the LSA fenestration was less frequently stented (52%) in the emergency group. There was no difference in stroke frequency. There was a higher rate of death in the emergency group at 30 days of follow-up, but no patient died from aortic cause in the long-term follow-up. CONCLUSIONS: Aortic arch repair with single-fenestrated PMEGs for zone 2 pathological arch disease is associated with acceptable early and midterm major morbidity and mortality. It is suitable for emergency situations. CLINICAL IMPACT: Single-fenestrated PMEG for the left subclavian artery is a safe and efficient option in the short and medium term for the treatment of the aortic arch in zone 2 with 98% technical success. It allows for aortic repair and subclavian artery revascularization in a single step for all patients. It is suitable for a range of main pathologies, including degenerative, dissection-related, isthmus rupture, and embolic pathologies. Additionally, it is always available and easily utilized in emergency cases.

6.
Ann Vasc Surg ; 90: 100-108, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36270548

RESUMO

BACKGROUND: Obtaining a suitable proximal landing zone in blunt thoracic aortic injuries (BTAI) often necessitates coverage of the left subclavian artery (LSA). This study aimed to evaluate the outcomes of physician-modified endovascular grafts (PMEGs) in this indication. METHODS: We performed a retrospective analysis of a prospective registry including all patients who had undergone a thoracic endovascular aortic repair (TEVAR) for BTAI from October 2008 to October 2020. Starting in 2015, patients requiring coverage of the LSA were either treated using a physician-modified proximal scalloped or single-fenestrated stent graft. After an early postoperative computed tomography scan, follow-up was performed at 3 months, 6-months, and yearly. RESULTS: Among 58 patients treated with TEVAR for BTAI, 23 (39.6%) patients required a zone 2 landing zone of which 10 (17.2%) patients were treated with PMEGs. The median age was 48 [31-64.5] years, and 78.2% (n = 18) patients were male. The median Injury Severity Score was 38 [27-55.5]. Coverage of the LSA was performed in 25.8% (n = 15) of the total population in which 5 patients had an LSA transposition. The median modification time was 18 [14-27] minutes. Technical success of PMEGs was 90.0% overall and 100% for fenestrated stent grafts. No stroke, paraplegia, or retrograde dissection was observed. The primary patency of the LSA in the PMEGs group was 90 % at 1 year and 28.8 % in the LSA coverage group (P < 0.01). CONCLUSIONS: The use of PMEGs is feasible and effective in the management of BTAI with a short proximal landing zone. Further evaluation of long-term outcomes and durability are awaited.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Stents , Estudos Retrospectivos , Resultado do Tratamento , Aorta Torácica/cirurgia , Procedimentos Endovasculares/efeitos adversos
7.
J Surg Res ; 276: 416-432, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35465975

RESUMO

INTRODUCTION: The use of video-assisted thoracoscopic surgery (VATS) lobectomy has become a mainstay of modern thoracic surgery practice and the technique of choice for resection of early-stage lung cancers. However, the benefits of VATS following induction therapy are yet to be clarified. This study aims to assess whether VATS lobectomy achieves similar perioperative and oncologic outcomes compared to thoracotomy for nonsmall cell lung cancer after induction therapy. METHODS: We retrospectively reviewed the outcomes of 72 patients who underwent lung lobectomy after induction therapy in our institution from January 2017 to January 2020. Subsequently, we carried out a comprehensive literature search and pooled our results with available data from previously published studies to perform a meta-analysis. RESULTS: VATS was associated with reduced intraoperative blood loss (P = 0.05) and less perioperative complications (P = 0.04) in our local institution. The meta-analysis comprised nine studies. A total of 943 patients underwent VATS and 2827 patients underwent open lobectomy. VATS was associated with significant shorter surgery duration (P < 0.0001), shorter chest-tube drainage duration (P < 0.0001), and shorter hospital stays (P < 0.0001). Furthermore, there was significantly less perioperative complications (P = 0.006) and less intraoperative blood loss (P = 0.036) in the VATS group. However, there were no significant differences in 3-y overall survival and 3-y disease-free survival rates. CONCLUSIONS: In some selected patients undergoing induction therapy, VATS lobectomy could achieve equivalent perioperative outcomes to thoracotomy but evidence is lacking on oncologic outcomes. Further trials with a focus on oncologic outcomes and longer follow-up are required.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Perda Sanguínea Cirúrgica , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Humanos , Quimioterapia de Indução , Neoplasias Pulmonares/cirurgia , Pneumonectomia/métodos , Estudos Retrospectivos , Cirurgia Torácica Vídeoassistida/métodos , Toracotomia/métodos
8.
J Endovasc Ther ; 29(5): 773-779, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34955055

RESUMO

PURPOSE: This study assessed morphological changes in the aortic true and false lumens during follow-up of patients undergoing TEVAR (Thoracic Endovascular Aortic Repair) for complicated acute and subacute type B dissection. The study analyzes the effectiveness of TEVAR in preventing distal aneurysmal progression. MATERIALS AND METHODS: All patients between 2009 and 2019 undergoing TEVAR for complicated acute and subacute type B dissection at the study institution were retrospectively reviewed. Maximal diameters were measured on the proximal descending aorta right below the left subclavian artery, thoraco-abdominal junction right above the celiac trunk, and infrarenal aortic right above the inferior mesenteric artery, pre-operatively and during follow-up, analyzing either expansion or shrinkage of true and false lumens at these 3 sites. RESULTS: Forty-one patients were included. Thirty-day incidence of death, stroke, paraplegia, and visceral ischemia was, respectively, 8% (n = 4), 6% (n = 3), 2% (n = 1), and 2% (n = 1). Three patients (6%) died from intervention-related cause. Mortality was 17% (n = 8) during a mean follow-up of 54 months. One patient had aneurysmal dilation of the descending aorta needing additional coverage and only 2 (4%) developed thoraco-abdominal aneurysms requiring re-intervention. In the remaining patients, both significant expansion of the true lumen and shrinkage of false lumen were observed at all 3 sites. CONCLUSION: Proximal coverage of the main entry tear appears to prevent aneurysmal progression in most patients (96%). With such promising results, TEVAR should be considered as a first-line treatment in acute and subacute type B dissection.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Abdominal/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
9.
J Endovasc Ther ; : 15266028221116747, 2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-35927926

RESUMO

OBJECTIVE: The aim was to evaluate early and medium-term outcomes of double fenestrated physician-modified endovascular grafts for total endovascular aortic arch repair. METHODS: This single-center retrospective analysis of prospectively-collected data included 100 patients, from January 2017 to December 2021, undergoing thoracic endovascular aortic repair (TEVAR) for zone 0. The fenestrations were a proximal larger fenestration that incorporated the brach2iocephalic trunk and left common carotid artery and a distal smaller fenestration for the left subclavian artery (LSA). Only the LSA fenestration was stented. RESULTS: The median duration for stent-graft modification was 23±6 minutes. Of the 100 patients, 70 were men. The mean patient age was 70±10.5 years. Indications for treatment included degenerative aortic arch aneurysm (n=32), dissecting aortic arch aneurysm after type A dissections (n=23) and (n=19) after type B dissections, acute complicated type B dissection (n=16), and other pathologies (n=10). Technical success rate was 97%. The 30 day mortality was 2% (n=2). Four patients (4%) had minor stroke with full recovery. One patient (1%) had a type IA endoleak, 1 patient (1%) had a type IB endoleak, and 2 patients (2%) have a type II endoleak from the LSA. Eight patients (8%) required reintervention: 1 type IA endoleak, 1 type IB endoleak, 1 retrograde type A dissection, and 5 because of access-related complications. During a mean follow-up of 24±7.2 months, there were no aortic rupture, paraplegia, and all supra-aortic trunks were patent. CONCLUSIONS: Double homemade fenestrated TEVAR is both feasible and effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The long-term durability will need to be assessed in studies with long-term follow-up. CLINICAL IMPACT: Double homemade fenestrated TEVAR is effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The standout feature of this double fenestrated device is its simple handling during operation with the proximal fenestrations being directed to the orifices of the BT and LCCA automatically when the LSA fenestration is catheterized and secured by covered stent placement. The deployment algorithm actively steers the operator away from superfluous manipulations of the device within the arch and avoids guidewire manipulation in carotid arteries. The long-term durability will need to be assessed in studies with long-term follow-up.

11.
JTCVS Tech ; 25: 8-18, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899088

RESUMO

Objective: This study aims to assess the feasibility and effectiveness of physician-modified fenestrated stent grafts (PMEGs) in treating type 1a endoleak after conventional thoracic endovascular aortic repair (TEVAR) in aortic arch pathologies. Methods: Patients who developed a type 1a endoleak after conventional TEVAR were included in the study. They underwent treatment with fenestrated PMEGs, which involved single or double fenestration for the supra-aortic trunks. Results: Twenty patients were treated with PMEGs between October 2018 and November 2023. Among them, 25% received single fenestrated PMEGs and 75% received double fenestrated PMEGs. The technical success rate was 100% for both types. Eighty percent of the PMEGs had a landing zone in zone 0, whereas 20% had a landing zone in zone 2. There were no in-hospital deaths. After 30 days, 1 patient died as the result of an aortic-related cause (retrograde dissection). The mean follow-up time was 16.5 months (range, 0-60 months). No major adverse events such as stroke or spinal ischemia were reported. No type 1 or type 3 endoleaks were observed, and one type 2 endoleaks required peripheral endovascular reintervention. Conclusions: The treatment of type 1a endoleaks using fenestrated PMEGs after conventional TEVAR for aortic arch pathologies is a viable option. It is associated with acceptable rates of early and midterm major morbidity and mortality.

12.
Ann Vasc Surg ; 27(6): 801.e5-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23711968

RESUMO

We report a case of heparin-induced thrombocytopenia in a patient on low molecular weight heparin bridge therapy who developed acute abdominal aortic stent-graft thrombosis 1 week after uncomplicated endovascular abdominal aortic aneurysm repair. The diagnosis was confirmed by a computed tomographic scan of the abdomen. The patient was successfully treated by conversion to open repair. The postoperative course was marked by subacute left limb ischemia related to an in vivo cross-reactivity of danaparoid with the heparin immune complex. To our knowledge, this is the first case report of heparin-induced thrombocytopenia with acute abdominal aortic stent-graft thrombosis.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Remoção de Dispositivo/métodos , Oclusão de Enxerto Vascular/etiologia , Heparina/efeitos adversos , Trombectomia/métodos , Trombocitopenia/induzido quimicamente , Trombose/etiologia , Doença Aguda , Idoso , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/cirurgia , Heparina/uso terapêutico , Humanos , Masculino , Trombocitopenia/complicações , Trombose/diagnóstico , Trombose/cirurgia , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler Dupla
13.
Cancers (Basel) ; 15(2)2023 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-36672363

RESUMO

Objectives: This study aims to evaluate the perioperative and oncologic outcomes of thoracoscopic lobectomy for advanced stage III NSCLC. Methods: We retrospectively reviewed 205 consecutive patients who underwent VATS or open lobectomy for clinical stage III lung cancer between January 2013 and December 2020. The perioperative and oncologic outcomes of the two approaches were compared. Long-term survival was assessed using the Kaplan−Meier estimator. Propensity score-matched (PSM) comparisons were used to obtain a well-balanced cohort of patients undergoing VATS and open lobectomy. Results: VATS lobectomy was performed in 77 (37.6%) patients and open lobectomy in 128 (62.4%) patients. Twelve patients (15.6%) converted from VATS to the open approach. PSM resulted in 64 cases in each group, which were well matched according to twelve potential prognostic factors, including tumor size, histology, and pTNM stage. Between the VATS and the open group, there were no significant differences in unmatched and matched analyses, respectively, of the overall postoperative complications (p = 0.138 vs. p = 0.109), chest tube duration (p = 0.311 vs. p = 0.106), or 30-day mortality (p = 1 vs. p = 1). However, VATS was associated with shorter hospital stays (p < 0.0001). The five-year overall survival (OS) and five-year Recurrence-free survival (RFS) were comparable between the VATS and the open groups. There was no significant difference in the recurrence pattern between the two groups in both the unmatched and matched analyses. Conclusion: For the advanced stage III NSCLC, VATS lobectomy achieved equivalent postoperative and oncologic outcomes when compared with open lobectomy without increasing the risk of procedure-related locoregional recurrence.

14.
Cancers (Basel) ; 15(20)2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37894338

RESUMO

BACKGROUND: The aim of this single-center retrospective cohort study was to assess the impact of arterial reconstruction technique on lung perfusion. The second objective was to ascertain the functional validity of arterial sleeve lobectomy. METHOD: Between January 2001 and December 2020, a total of 81 patients underwent lobectomy with pulmonary artery (PA) reconstruction for lung cancer at the University Hospital of Montpellier. After excluding patients with an incomplete postoperative pulmonary function test, we conducted a comparative analysis of the preoperative and postoperative functional outcomes (FEV1) of 48 patients, as well as the preoperative and postoperative Technetium99m scintigraphic pulmonary perfusion results of 28 patients. Then, we analyzed postoperative perfusion results according to the pulmonary artery reconstruction techniques use. RESULTS: PA reconstruction types were as follows: 9 direct angioplasties (19%), 14 patch angioplasties (29%), 7 end-to-end anastomoses (15%), 6 prosthetic bypasses (12%), 11 arterial allograft bypasses (23%), and 1 custom-made xenopericardial conduit bypass. Regardless of the type of vascular reconstruction performed, the comparative analysis of lung perfusion revealed no significant difference between the preoperative and postoperative perfusion ratio of the remaining parenchyma (median = 29.5% versus 32.5%, respectively; p = 0.47). Regarding the pulmonary functional test, postoperative predicted FEV1 significantly underestimated the actual postoperative measured FEV1 by about 260 mL (11.4%) of the preoperative value. The patency rate was 96% and the 5-year overall survival was 49% for a mean follow up period of 34 months. CONCLUSION: Lobectomy with PA reconstruction is a valid parenchymal-sparing technique in terms of perfusion and respiratory function.

15.
Ann Vasc Surg ; 26(5): 715-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22664283

RESUMO

BACKGROUND: The aim of this study was to evaluate the short- and midterm results following endovascular repair of dissecting aortic arch aneurysm after surgical treatment of acute type A dissection. METHODS: Between 2003 and 2010, six consecutive patients previously operated for acute type A dissection underwent endovascular repair of dissecting aortic arch aneurysm (six men, mean age: 63 ± 9.8 years); one of the aneurysms was ruptured. Follow-up computed tomography scans were performed at 1 week, at 3 and 6 months, and annually thereafter. RESULTS: All endografts were successfully deployed (TAG [2], Valiant [4]). All the patients underwent hybrid technique with supra-aortic debranching (through a sternotomy approach in four cases and through a cervical approach in two cases) and simultaneous or staged endovascular stent-grafting. During the same operative time, one patient underwent, on full cardiopulmonary bypass, saphenous vein bypass from the ascending aorta to the anterior descending coronary artery. One permanent neurologic event was observed. After a mean follow-up of 22.3 ± 14.6 months, no aortic-related mortality was observed. No cases of stent-graft migration or secondary rupture were observed. The ruptured aortic arch aneurysm presented a type I endoleak at 6 months and was successfully treated with a second endograft. One patient died of an unrelated cause 7 months after surgical repair. CONCLUSIONS: Our experience demonstrates promising potential of endovascular repair of dissecting aortic arch aneurysm after surgical treatment of acute type A dissection. The potential to diminish the magnitude of the surgical procedure and the consequences of aortic arch exposure, and above all avoiding the need for circulatory arrest, is promising and mandates further investigation to determine the efficacy and durability of this technique.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Doença Aguda , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Stents , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
16.
Interact Cardiovasc Thorac Surg ; 34(1): 74-80, 2022 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-34999810

RESUMO

OBJECTIVES: This article aims to evaluate the feasibility and safety of a hybrid video-assisted thoracic surgery (VATS) approach to achieve en bloc lobectomy and spinal resection for non-small-cell lung cancer (NSCLC). METHODS: Between October 2015 and November 2020, 10 patients underwent VATS anatomical lobectomy and en bloc chest wall and spinal resection through a limited posterior midline incision as a single operation for T4 (vertebral involvement) lung cancer. Nine patients had Pancoast syndrome without vascular involvement and 1 patient had NSCLC of the right lower lobe with invasion of T9 and T10. RESULTS: There were 5 men and 5 women. The mean age was 61 years (range: 47-74 years). Induction treatment was administered to 9 patients (90%). The average operative time was 315.5 min (range: 250-375 min). The average blood loss was 665 ml (range: 100-2500 ml). Spinal resection was hemivertebrectomy in 6 patients and wedge corpectomy in 4 patients. Complete resection (R0) was achieved in all patients. The average hospitalization stay was 14 days (range: 6-50 days). There was no in-hospital mortality. The mean follow-up was 32.3 months (range: 6-66 months). Six patients (60%) are alive without recurrence. CONCLUSIONS: VATS is feasible and safe to achieve en bloc resection of NSCLC inviding the spine without compromising oncological efficacy. Further experience and longer follow-up are needed to determine if this approach provides any advantages over thoracotomy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Cirurgia Torácica Vídeoassistida , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Feminino , Humanos , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Síndrome de Pancoast , Pneumonectomia/efeitos adversos , Cirurgia Torácica Vídeoassistida/efeitos adversos , Vértebras Torácicas
17.
J Vasc Surg ; 54(4): 1145-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21658890

RESUMO

Hybrid repair of ruptured aortic arch repair has been proposed as a valuable approach. However, the presence of an anterior mediastinal hematoma must be carefully detected because of the inherent risk of rupture at sternotomy. We report the case of a patient presenting a ruptured aortic arch aneurysm with anterior rupture who underwent hybrid repair using a temporary extra-anatomic brain perfusion followed by total rerouting of the supra-aortic trunks. We propose this adjunctive technique as a means of allowing a safe endovascular exclusion of aortic arch lesions and avoiding the risk of acute and total aortic rupture in case of anterior rupture of aortic arch aneurysms.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Perfusão/métodos , Idoso , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/fisiopatologia , Aortografia/métodos , Circulação Cerebrovascular , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Hemodinâmica , Humanos , Masculino , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
J Endovasc Ther ; 18(4): 485-90, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21861734

RESUMO

PURPOSE: To analyze the impact of stent-graft design on the outcome of endovascular repair of acute traumatic thoracic aortic transection. METHODS: Forty-eight patients (38 men; mean age 37 ± 11 years) underwent endovascular repair for an acute traumatic aortic rupture between April 2001 and March 2011. Up to October 2007, 32 patients (mean age 41 ± 16 years; group 1) were treated with the first generation of commercially available thoracic stent-grafts (10 Talent, 20 Excluder/TAG, 2 Zenith). From November 2007, 16 patients (mean age 42 ± 19 years; group 2) were treated with second-generation thoracic stent-grafts (13 Valiant and 3 C-TAG). The 2 groups were statistically comparable. Follow-up computed tomography was performed at 1 week; at 3 and 6 months; and annually thereafter. RESULTS: In the 2 groups, the mortality rate related to aortic repair was nil. All the patients have completed each of their scheduled follow-up evaluations and CT scans. The morbidity rate was significantly reduced (p = 0.0003) from 18.7% (first generation) to 6.2% (second generation). Type I endoleak (n = 1), inadvertent coverage of the supra-aortic trunks (n = 3), and stent-graft collapse (n = 2) occurred only with the first-generation stent-grafts. One iliac artery rupture occurred with a second-generation stent-graft. CONCLUSION: Enhanced stent-graft conformability and more accurate delivery systems have significantly decreased the morbidity of endovascular repair of acute traumatic transection of the thoracic aorta. The increasing clinical experience may also have contributed to improved results.


Assuntos
Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Artérias Torácicas/cirurgia , Lesões do Sistema Vascular/cirurgia , Doença Aguda , Adulto , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Medição de Risco , Fatores de Risco , Artérias Torácicas/diagnóstico por imagem , Artérias Torácicas/lesões , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/mortalidade , Adulto Jovem
19.
Ann Vasc Surg ; 25(3): 327-32, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20926239

RESUMO

BACKGROUND: The aim of this study was to evaluate the short-term and midterm results of endovascular repair of false aneurysm formation after coarctation repair. METHODS: Between November 1998 and August 2009, seven patients underwent endovascular repair for false aneurysm formation after coarctation repair (two women, five men; mean age: 45.4 ± 12.1 years; range: 30-60 years). Follow-up computed tomography scans were performed at 1 week, 3 months, 6 months, and annually thereafter. RESULTS: All endografts were successfully deployed (Excluder-TAG in three patients, Talent in one patient, Valiant in three patients). Among them, six patients underwent hybrid technique with supra-aortic debranching and simultaneous or staged endovascular stent grafting as follows: transposition of the left common carotid artery (LCCA) into the brachiocephalic trunk which was later followed by transposition of the left subclavian artery into the LCCA in one case and transposition of the left subclavian artery into the LCCA in remaining five cases. No major complications occurred. A mean follow-up of 44.8 ± 41.3 months (range: 1-131 months) demonstrated no endoleak, rupture, conversion, or migration. CONCLUSIONS: Short-and mid-term results of endovascular treatment of false aneurysm formation after coarctation repair favor the proposition of endovascular repair as a first-line treatment option. Long-term survival studies are mandatory to determine the efficacy and durability of this technique.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Coartação Aórtica/cirurgia , Procedimentos Endovasculares , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Adulto , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aortografia/métodos , Prótese Vascular , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Stents , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
Ann Vasc Surg ; 25(2): 266.e5-7, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20889306

RESUMO

Aortic arch rupture is a life-threatening emergency. Conventional open surgical repair carries a high mortality and morbidity. We report a case of an elderly patient who suffered from a ruptured and infected penetrating ulcer of the aortic arch. A hybrid operation was performed, consisting of a right-to-left carotid bypass and transposition of the left subclavian artery into the left common carotid artery followed by endovascular repair of the aortic arch. Antibiotic therapy, based on the results of culture and sensitivity tests for Staphylococcus aureus, was administered for 6 months. The patient recovered uneventfully and remains asymptomatic 16 months after the procedure. However, long-term follow-up is mandatory to determine the efficacy and the durability of this technique.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Ruptura Aórtica/cirurgia , Aterosclerose/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Infecções Estafilocócicas/cirurgia , Úlcera/cirurgia , Procedimentos Cirúrgicos Vasculares , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/microbiologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/microbiologia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/microbiologia , Aortografia/métodos , Aterosclerose/diagnóstico por imagem , Aterosclerose/microbiologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Artérias Carótidas/cirurgia , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Infecções Estafilocócicas/diagnóstico por imagem , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/isolamento & purificação , Stents , Artéria Subclávia/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Úlcera/diagnóstico por imagem , Úlcera/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA