Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Indoor Air ; 32(11): e13161, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36437677

RESUMO

Hospital-acquired infections (HAIs) are a global challenge incurring mortalities and high treatment costs. The environment plays an important role in transmission due to contaminated air and surfaces. This includes microorganisms' deposition from the air onto surfaces. Quantifying the deposition rate of microorganisms enables understanding surface contamination and can inform strategies to mitigate the infection risk. We developed and validated a novel Automated Multiplate Passive Air Sampling (AMPAS) device. This enables sequences of passive deposition samples to be collected over a controlled time period without human intervention. AMPAS was used with air sampling to measure the effect of ventilation rate and spatial location on the deposition rate of aerosolized Staphylococcus aureus in a 32 m3 chamber. Increasing the ventilation rate from 3 to 6 ACH results in a reduction of microbial load in the air and on surfaces by 45% ± 10% and 44% ± 32%, respectively. The deposition rate onto internal surfaces λd was calculated as 1.38 ± 0.48 h-1 . Samples of airborne and surface microorganisms taken closer to the ventilation supply showed a lower concentration than close to the extract. The findings support the importance of controlling the ventilation and the environmental parameters to mitigate both air and surface infection risks in the hospital environment.


Assuntos
Poluição do Ar em Ambientes Fechados , Infecção Hospitalar , Humanos , Poluição do Ar em Ambientes Fechados/análise , Ventilação , Staphylococcus aureus , Hospitais
2.
Indoor Air ; 32(1): e12938, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34693567

RESUMO

Self-contamination during doffing of personal protective equipment (PPE) is a concern for healthcare workers (HCW) following SARS-CoV-2-positive patient care. Staff may subconsciously become contaminated through improper glove removal; so, quantifying this exposure is critical for safe working procedures. HCW surface contact sequences on a respiratory ward were modeled using a discrete-time Markov chain for: IV-drip care, blood pressure monitoring, and doctors' rounds. Accretion of viral RNA on gloves during care was modeled using a stochastic recurrence relation. In the simulation, the HCW then doffed PPE and contaminated themselves in a fraction of cases based on increasing caseload. A parametric study was conducted to analyze the effect of: (1a) increasing patient numbers on the ward, (1b) the proportion of COVID-19 cases, (2) the length of a shift, and (3) the probability of touching contaminated PPE. The driving factors for the exposure were surface contamination and the number of surface contacts. The results simulate generally low viral exposures in most of the scenarios considered including on 100% COVID-19 positive wards, although this is where the highest self-inoculated dose is likely to occur with median 0.0305 viruses (95% CI =0-0.6 viruses). Dose correlates highly with surface contamination showing that this can be a determining factor for the exposure. The infection risk resulting from the exposure is challenging to estimate, as it will be influenced by the factors such as virus variant and vaccination rates.


Assuntos
Poluição do Ar em Ambientes Fechados , COVID-19 , Fômites , Exposição Ocupacional , Equipamento de Proteção Individual , Fômites/virologia , Luvas Protetoras/virologia , Hospitais , Humanos , Equipamento de Proteção Individual/virologia , SARS-CoV-2
3.
Indoor Air ; 31(5): 1308-1322, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33945176

RESUMO

Airborne microorganisms in hospitals have been associated with several hospital-acquired infections (HAIs), and various measures of indoor air quality (IAQ) parameters such as temperature, relative humidity, carbon dioxide (CO2 ), particle mass concentration, and particle size have been linked to pathogen survival or mitigation of pathogen spread. To investigate whether there are quantitative relationships between the concentration of airborne microorganisms and the IAQ in the hospital environment. Web of Science, Scopus and PubMed databases were searched for studies reporting airborne microbial levels and any IAQ parameter(s) in hospital environments, from database inception to October 2020. Pooled effect estimates were determined via random-effects models. Seventeen of 654 studies were eligible for the meta-analysis. The concentration of airborne microbial measured as aerobic colony count (ACC) was significantly correlated with temperature (r = 0.25 [95% CI = 0.06-0.42], p = 0.01), CO2 concentration (r = 0.53 [95% CI = 0.40-0.64], p Ë‚ 0.001), particle mass concentration (≤5 µg/m3 ; r = 0.40 [95% CI = 0.04-0.66], p = 0.03), and particle size (≤5 and ˃5 µm), (r = 0.51 [95% CI = 0.12-0.77], p = 0.01 and r = 0.55 [95% CI = 0.20-0.78], p = 0.003), respectively, while not being significantly correlated with relative humidity or particulate matter of size >5 µm. Conversely, airborne total fungi (TF) were not significantly correlated with temperature, relative humidity, or CO2 level. However, there was a significant weak correlation between ACC and TF (r = 0.31 [95% CI = 0.07-0.52], p = 0.013). Although significant correlations exist between ACC and IAQ parameters, the relationship is not definitive; the IAQ parameters may affect the microorganisms but are not responsible for the presence of airborne microorganisms. Environmental parameters could be related to the generating source, survival, dispersion, and deposition rate of microorganisms. Future studies should record IAQ parameters and factors such as healthcare worker presence and the activities carried out such as cleaning, sanitizing, and disinfection protocols. Foot traffic would influence both the generation of microorganisms and their deposition rate onto surfaces in the hospital environment. These data would inform models to improve the understanding of the likely concentration of airborne microorganisms and provide an alternative approach for real-time monitoring of the healthcare environment.


Assuntos
Microbiologia do Ar , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Hospitais , Material Particulado , Dióxido de Carbono , Monitoramento Ambiental , Fungos , Humanos , Temperatura
4.
Indoor Air ; 30(5): 993-1004, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32329918

RESUMO

Bacterial transmission from contaminated surfaces via hand contact plays a critical role in disease spread. However, the fomite-to-finger transfer efficiency of microorganisms during multiple sequential surface contacts with and without gloves has not been formerly investigated. We measured the quantity of Escherichia coli on fingertips of participants after 1-8 sequential contacts with inoculated plastic coupons with and without nitrile gloves. A Bayesian approach was used to develop a mechanistic model of pathogen accretion to examine finger loading as a function of the difference between E coli on surfaces and fingers. We used the model to determine the coefficient of transfer efficiency (λ), and influence of swabbing efficiency and finger area. Results showed that λ for bare skin was higher (49%, 95% CI = 32%-72%) than for gloved hands (30%, CI = 17%-49%). Microbial load tended toward a dynamic equilibrium after four and six contacts for gloved hands and bare skin, respectively. Individual differences between volunteers' hands had a negligible effect compared with use of gloves (P < .01). Gloves reduced loading by 4.7% (CI = -12%-21%) over bare skin contacts, while 20% of participants accrued more microorganisms on gloved hands. This was due to poor fitting, which created a larger finger surface area than bare hands.


Assuntos
Bactérias , Fômites/microbiologia , Luvas Protetoras/microbiologia , Mãos/microbiologia , Desinfecção das Mãos , Humanos
5.
Sci Rep ; 12(1): 4373, 2022 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-35322064

RESUMO

Many infectious diseases, including COVID-19, are transmitted by airborne pathogens. There is a need for effective environmental control measures which, ideally, are not reliant on human behaviour. One potential solution is Krypton Chloride (KrCl) excimer lamps (often referred to as Far-UVC), which can efficiently inactivate pathogens, such as coronaviruses and influenza, in air. Research demonstrates that when KrCl lamps are filtered to remove longer-wavelength ultraviolet emissions they do not induce acute reactions in the skin or eyes, nor delayed effects such as skin cancer. While there is laboratory evidence for Far-UVC efficacy, there is limited evidence in full-sized rooms. For the first time, we show that Far-UVC deployed in a room-sized chamber effectively inactivates aerosolised Staphylococcus aureus. At a room ventilation rate of 3 air-changes-per-hour (ACH), with 5 filtered-sources the steady-state pathogen load was reduced by 98.4% providing an additional 184 equivalent air changes (eACH). This reduction was achieved using Far-UVC irradiances consistent with current American Conference of Governmental Industrial Hygienists threshold limit values for skin for a continuous 8-h exposure. Our data indicate that Far-UVC is likely to be more effective against common airborne viruses, including SARS-CoV-2, than bacteria and should thus be an effective and "hands-off" technology to reduce airborne disease transmission. The findings provide room-scale data to support the design and development of effective Far-UVC systems.


Assuntos
COVID-19 , Infecções Estafilocócicas , Desinfecção , Humanos , SARS-CoV-2 , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA