Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Ann Thorac Surg ; 68(3): 864-9, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10509975

RESUMO

BACKGROUND: Optimal conditions for deep hypothermic perfusion and protective brain blood flow remain unclear. METHODS: Dogs (n = 52) underwent 120 minutes of cardiopulmonary bypass at 20 degrees C with perfusion flow rates of 2.5, 5, 10, 20, 40, and 100 mL x kg(-1) x min(-1). We examined the effect of the various flow rates and different perfusion pressures on brain blood flow, metabolism, and intracellular pH. RESULTS: The brain was ischemic and acidotic when the perfusion flow rate was less than 5 mL kg(-1) x min(-1) and pressure was less than 10 mm Hg. When perfusion pressure was higher than 10 mm Hg, cerebral cortex blood flow was more than 9 mL x 100 g(-1) x min(-1) and intracellular pH, higher than 6.95. The cerebral metabolic rate for oxygen decreased at a flow rate of 2.5 mL x kg(-1) min(-1). The cerebral metabolic ratio of glucose to oxygen and the cerebral vascular resistance were lowest when perfusion pressure was 10 to 30 mm Hg. Full-flow (100 mL x kg(-1) x min(-1)) perfusion caused paradoxical brain acidosis; a flow of 40 mL x kg(-1) x min(-1) provided the best results. CONCLUSIONS: Both extremely low-flow perfusion and excessive perfusion cause brain acidosis. Low-flow perfusion at a pressure of 20 mm Hg provides cerebral vasorelaxation and aerobic metabolism during operations at 20 degrees C.


Assuntos
Ponte Cardiopulmonar , Circulação Cerebrovascular , Hipotermia Induzida , Animais , Velocidade do Fluxo Sanguíneo , Encéfalo/metabolismo , Córtex Cerebral/irrigação sanguínea , Cães , Glucose/metabolismo , Concentração de Íons de Hidrogênio , Consumo de Oxigênio , Resistência Vascular
2.
Acad Radiol ; 4(7): 513-8, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9232172

RESUMO

RATIONALE AND OBJECTIVES: The authors performed an in vitro study to evaluate a temporary venous spring filter that can extend vessels of a wide range of diameters to a slit-shaped canal. MATERIALS AND METHODS: Filters were placed in thin polyethylene tubes or in porcine inferior vena cava specimens (diameter, 10.0-16.0 mm). Physiologic saline was substituted for blood flow, and blood clots of three sizes (6 x 10, 6 x 20, and 9 x 20 mm) were funneled to the filter. Clot-trapping ability was assessed by the degree of luminal extension. RESULTS: When the luminal extension was increased from 2.6r to 2.8r (where r is the original radius of the vein models), clot-trapping ability increased significantly (61.1%-87.5% in polyethylene tubes and 15.8%-77.5% in venous specimens, P < .001). When the luminal extension was increased to 3.0r, more than 90% of the clots were trapped in all tubes. After trapping the small, medium, and large clots, mean intraluminal pressure elevation was 1.0, 1.0, and 17.0 cm of saline, respectively. CONCLUSION: Despite its simple design, the spring filter proved to be an efficient filtering device.


Assuntos
Filtros de Veia Cava , Animais , Desenho de Equipamento , Humanos , Modelos Cardiovasculares , Embolia Pulmonar/prevenção & controle , Suínos
3.
Acad Radiol ; 5(9): 620-5, 1998 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9750891

RESUMO

RATIONALE AND OBJECTIVES: The authors compared in vitro function of a temporary venous spring filter with that of a temporary RF02 filter and a permanent Greenfield filter. MATERIALS AND METHODS: All three types of filters were placed in thin polyethylene tubes (diameters, 10.0-18.0 mm). Physiologic saline was substituted for flowing blood, and blood clots of three sizes (6 x 10 mm, 6 x 20 mm, 9 x 20 mm) were funneled to the filters. Clot-trapping ability of each filter and elevation of intraluminal pressure after clot trapping were assessed for each tube size. RESULTS: No statistically significant elevation in intraluminal pressure was detected immediately after placement of any filter. The clot-trapping ability of the spring filter and of Greenfield filter were slightly lower than that of the RF02 filter, but the differences were not statistically significant. After filters had trapped large clots, a high pressure gradient was detected in the 10.0-mm tube for all filters. The spring filter was associated with a higher pressure than the other filters in the 12.0-mm tube (P < .05). CONCLUSION: In vitro function of the spring filter was satisfactory in comparison with that of the RF02 filter and the Greenfield filter. For efficient filtering in the inferior vena cava, development of a larger version of the filter may be necessary.


Assuntos
Filtros de Veia Cava , Desenho de Equipamento , Técnicas In Vitro , Modelos Estruturais , Embolia Pulmonar/prevenção & controle
4.
Acad Radiol ; 6(6): 343-51, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10376065

RESUMO

RATIONALE AND OBJECTIVES: The authors performed this study to compare the in vivo efficacies of the temporary venous spring filter and the RF02 filter in an animal model. MATERIALS AND METHODS: Either the spring filter or the RF02 filter was placed in the inferior vena cava of 10 pigs each, and two clots (5 x 20 mm) were funneled into the filters at 1-hour intervals. The second clots were funneled without removing the first clots captured by the filters. Clot-trapping ability, caval occlusion associated with the clot-trapping procedure, arterial blood gas concentrations, and changes in arterial and iliac venous pressures were evaluated. RESULTS: Placement of the RF02 filter caused elevation of iliac venous pressure with a maximum of 2.2 mm Hg (median) (n = 13, P = .003). Placement of the spring filter parallel to venous flow enabled capture of 90% (nine of 10) and 100% (six of six) of the first and second clots, respectively. The RF02 filter captured clots consistently. The difference between filters was not statistically significant. Both filters equally contributed to elevation of iliac venous pressure (median, 9.3 and 7.2 mm Hg [n = 9] with the spring filter and RF02 filter, respectively). Caval occlusion occurred in 17% (one of six) and 67% (six of nine) of animals after two clots were trapped in the spring filter and RF02 filter, respectively (P = .06). Other parameters were not influenced by the clot-trapping procedure. CONCLUSION: Although a larger version should be developed and better stability of the filter is needed, the spring filter proved to be an efficient filtering device and had a lower rate of caval occlusion compared with the RF02 filter.


Assuntos
Filtros de Veia Cava , Animais , Distribuição de Qui-Quadrado , Desenho de Equipamento , Hemodinâmica , Projetos Piloto , Embolia Pulmonar/fisiopatologia , Embolia Pulmonar/prevenção & controle , Radiografia , Radiologia Intervencionista , Estatísticas não Paramétricas , Suínos , Veia Cava Inferior/diagnóstico por imagem
5.
Jpn J Antibiot ; 44(5): 571-9, 1991 May.
Artigo em Japonês | MEDLINE | ID: mdl-1652655

RESUMO

In vitro antifungal activities of itraconazole (ITZ), a triazole antifungal agent, against clinical isolates obtained from patients with superficial and subcutaneous mycoses were examined using the agar dilution method on casitone agar. The clinical isolates tested were 7 species and 263 isolates including Trichophyton mentagrophytes (104 isolates), Trichophyton rubrum (103 isolates), Microsporum canis (3 isolates), Epidermophyton floccosum (2 isolates), Candida albicans (32 isolates), Malassezia furfur (7 isolates) and Sporothrix schenckii (12 isolates). The results are summarized as follows: 1. MIC values of ITZ for the isolates of dermatophytes and M. furfur distributed in a range of less than 0.0012-5 micrograms/ml indicating that ITZ had greater in vitro activities. These in vitro activities of ITZ were greater than those of clotrimazole or bifonazole. 2. C. albicans isolates were divided into 2 groups in terms of ITZ-susceptibilities, a high susceptibility group and low-susceptibility group with MIC values of 0.02-0.08 micrograms/ml and greater than 10 micrograms/ml, respectively. 3. The in vitro activities of ITZ against S. schenckii isolates with a geometric mean MIC of 0.119 micrograms/ml were greater than those of ketoconazole, miconazole or amphotericin B used as reference drugs.


Assuntos
Antifúngicos , Dermatomicoses/microbiologia , Cetoconazol/análogos & derivados , Anfotericina B/farmacologia , Clotrimazol/farmacologia , Humanos , Imidazóis/farmacologia , Itraconazol , Cetoconazol/farmacologia , Miconazol/farmacologia , Testes de Sensibilidade Microbiana
6.
Kyobu Geka ; 46(10): 856-7, 1993 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-8377312

RESUMO

A new hanger for thoracic operation is introduced. This hanger for draping cloth is made for the purpose 1) of isolating the operative field from the anesthetist, 2) of keeping the broad hygienic area around the operator, 3) of keeping the area to handle the endotracheal tube for the anesthetist, 4) of keeping the area on the cranial side of the patient where the second assistant is able to stand, 5) of keeping the area for the watcher to stand.


Assuntos
Equipamentos Cirúrgicos , Cirurgia Torácica/instrumentação , Humanos
7.
Kyobu Geka ; 56(11): 973-6, 2003 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-14579703

RESUMO

We reported a successful case of emergent total arch replacement for a nonagenarian with acute Stanford A aortic dissection. A 92-year-old woman complained of general fatigue, with hypotension. Echocardiography showed moderate pericardial effusion and aortic regurgitation. Computed tomography (CT) scan showed widely extended aortic dissection from the ascending aorta to descending thoracic aorta, and cardiac tamponade. An emergent total arch replacement was performed under hypothermic selective cerebral perfusion with bladder temperature of 22.5 degrees C. Although she suffered from pneumothorax, renal insufficiency and gastrointestinal (GI) bleeding postoperatively, she tolerated the operation and complications, well. She is now leading a good life with the same level of activities of daily living (ADL) as preoperative one.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Aorta/cirurgia , Aorta Torácica/cirurgia , Feminino , Humanos
8.
Kyobu Geka ; 52(3): 218-23, 1999 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-10097549

RESUMO

Between 1978 and 1997, 9 patients developed poststernotomy mediastinitis after coronary artery bypass grafting. Four of these patients (group A) were treated with open drainage and mediastinal irrigation or omental transfer. The other 5 patients (group B) were treated with primary wound closure by the technique of muscle flap mobilization. The purpose of this study was to compare the surgical results and graft patency of both groups. The hospital mortality of group A was 100 per cent. All patients in group B survived for 35 months of the mean postoperative periods without complaints. Postoperative coronary angiography revealed the complete graft patency in group B. We conclude that muscle flap mobilization may be a superior measure for the patient survival and graft patency as the treatment of mediastinitis after coronary artery bypass grafting.


Assuntos
Ponte de Artéria Coronária , Mediastinite/cirurgia , Omento/transplante , Complicações Pós-Operatórias/cirurgia , Retalhos Cirúrgicos , Grau de Desobstrução Vascular , Idoso , Drenagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
9.
Nihon Rinsho ; 55(7): 1726-30, 1997 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-9233016

RESUMO

The mean transit time (MTT), cerebral blood flow (CBF) and cerebral blood volume (CBV) using echo planar imaging (EPI) in 22 aged volunteers were measured based on moment analysis and gamma variate method. The first peak of signal intensity curve (p delta R2.) and the area under the curve after the first peak (AUC) were calculated according to the height over area method, as a convenient quantification. Then, MTT, CBF, and CBV were compared with AUC/p delta R2, p delta R2, and AUC, respectively. There was a good correlation between each other parameter (r = 0.67 - 0.92, every p < 0.001). The slow upward slope and the low peak height, however, caused a larger error between each other parameter.


Assuntos
Encéfalo/patologia , Circulação Cerebrovascular , Imagem Ecoplanar/métodos , Velocidade do Fluxo Sanguíneo , Volume Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
Rinsho Hoshasen ; 34(2): 281-4, 1989 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-2547092

RESUMO

A case of 57-year-old man with multiple peripheral hepatic artery aneurysms is reported. The patient was admitted with liver dysfunction and detected hepatoma in the right lobe. Chemoembolization was performed for the treatment of hepatoma. After 35 days, reangiography revealed multiple peripheral hepatic artery aneurysms in the region of chemoembolization. The etiology of aneurysms were presumably drug induced arteritis.


Assuntos
Aneurisma/etiologia , Carcinoma Hepatocelular/complicações , Embolização Terapêutica/efeitos adversos , Artéria Hepática , Neoplasias Hepáticas/complicações , Carcinoma Hepatocelular/terapia , Humanos , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade
11.
Rinsho Hoshasen ; 34(5): 621-4, 1989 May.
Artigo em Japonês | MEDLINE | ID: mdl-2746957

RESUMO

A case of a 39-year-old male with ruptured right gastric artery aneurysm was reported. An emergency angiography was carried out followed by transarterial embolization. The TAE was of great value for the control of massive bleeding and for getting out of the urgent surgical operation. In the present report the clinical value of TAE as well as frequency and some diagnostic imagings on this disease was discussed.


Assuntos
Aneurisma/terapia , Embolização Terapêutica , Estômago/irrigação sanguínea , Adulto , Aneurisma/diagnóstico por imagem , Humanos , Masculino , Ruptura Espontânea , Tomografia Computadorizada por Raios X
13.
Phys Rev Lett ; 96(18): 181801, 2006 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-16712358

RESUMO

We performed an improved search for nu(mu) --> nu(e) oscillation with the KEK to Kamioka (K2K) long-baseline neutrino oscillation experiment, using the full data sample of 9.2 x 10(19) protons on target. No evidence for a nu(e) appearance signal was found, and we set bounds on the nu(mu) --> nu(e) oscillation parameters. At Deltam(2)=2.8 x 10(-3) eV(2), the best-fit value of the K2Knu(mu) disappearance analysis, we set an upper limit of sin(2)2theta(mue) < 0.13 at a 90% confidence level.

14.
Phys Rev Lett ; 95(25): 252301, 2005 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-16384451

RESUMO

We report the result from a search for charged-current coherent pion production induced by muon neutrinos with a mean energy of 1.3 GeV. The data are collected with a fully active scintillator detector in the K2K long-baseline neutrino oscillation experiment. No evidence for coherent pion production is observed, and an upper limit of is set on the cross section ratio of coherent pion production to the total charged-current interaction at 90% confidence level. This is the first experimental limit for coherent charged pion production in the energy region of a few GeV.

15.
Phys Rev Lett ; 94(8): 081802, 2005 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-15783876

RESUMO

We present results for nu(mu) oscillation in the KEK to Kamioka (K2K) long-baseline neutrino oscillation experiment. K2K uses an accelerator-produced nu(mu) beam with a mean energy of 1.3 GeV directed at the Super-Kamiokande detector. We observed the energy-dependent disappearance of nu(mu), which we presume have oscillated to nu(tau). The probability that we would observe these results if there is no neutrino oscillation is 0.0050% (4.0 sigma).

16.
Eur Radiol ; 7(3): 333-4, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9087352

RESUMO

Review of the literature shows no reports of vascular malformation of the gallbladder. Herein we report an unusual case of arteriovenous malformation of the gallbladder in a patient with hepatocellular carcinoma. The gallbladder lesion was found incidentally during abdominal angiography for the carcinoma. The angiographic features were specific, comprising dilated and tortuous feeding cystic arteries, a racemose vascular network, and early-filling cystic veins.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Vesícula Biliar/irrigação sanguínea , Adulto , Angiografia , Malformações Arteriovenosas/complicações , Carcinoma Hepatocelular/complicações , Humanos , Neoplasias Hepáticas/complicações , Masculino
17.
J Vasc Interv Radiol ; 6(6): 887-93, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-8850665

RESUMO

PURPOSE: To establish the influence of number of emboli on the trapping ability of vena cava filters in vitro. MATERIALS AND METHODS: Three filters, the titanium Greenfield, Vena Tech-LGM, and Günther Tulip retrievable, were studied with use of 20- or 26-mm-diameter tubes to simulate the inferior vena cava. In the first protocol, five small (4 x 20-mm) or medium (6 x 10-mm) emboli were delivered in sequence, and the fate of each was recorded. In the second protocol, medium or large (6 x 30-mm) clots were sequentially introduced until filter occlusion occurred or 50 clots had been delivered. RESULTS: For the first protocol, 82% of first small clots and 60% of second clots were trapped in 20-mm tubes (P = .001) and 63% and 45%, respectively, were trapped in 26-mm tubes (P - .02). With medium clots, the proportion trapped also dropped significantly with ascending clot rank. In the second protocol the proportion of clots captured was invariably higher for the first 10 clots (P < .001 for all combinations of covariables). CONCLUSION: Filter function deteriorates with number of emboli delivered, irrespective of embolus size and simulated vein caliber.


Assuntos
Embolia/patologia , Filtros de Veia Cava , Intervalos de Confiança , Desenho de Equipamento , Humanos , Intubação/instrumentação , Teste de Materiais/métodos , Modelos Estruturais , Fluxo Pulsátil , Propriedades de Superfície , Titânio , Veia Cava Inferior/anatomia & histologia
18.
Nihon Igaku Hoshasen Gakkai Zasshi ; 56(1): 66-7, 1996 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-8857103

RESUMO

Immediately after pelvic contrast MRA, subtraction MRA with additional administration of contrast agent was performed for evaluation of the femoropopliteal artery. Mask images were taken with three- dimensional spoiled GRASS (24/6.9/40 degrees), followed by contrast images with 7.5 - 10 ml of Gd-DTPA. The subtracted images provided excellent depiction of the arteries without the disruption of overlapping from the venous system or surrounding tissues. Seven lesions of arterial occlusion or stenosis were pointed out by subtraction MRA in the nine lesions confirmed with IADSA. Subtraction MRA is feasible for long segment imaging of the lower extremities with Gd-DTPA.


Assuntos
Angiografia Digital , Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Ácido Pentético/análogos & derivados
19.
J Vasc Interv Radiol ; 7(3): 395-400, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8761821

RESUMO

PURPOSE: To establish a new animal model of deep venous thrombosis. MATERIALS AND METHODS: Fifteen young pigs underwent temporary interruption of the inferior vena cava (IVC) below the entry of the right renal vein by means of either a silicone band (surgical technique, n = 6) or an intraluminal balloon catheter (endovascular technique, n = 9), followed by injection of absolute ethanol. Lumbar veins within 3 cm below the obstruction were ligated or occluded interventionally. The iatrogenic caval obstruction was relieved after 2 days. RESULTS: Procedure-related mortality was 33% (n = 2) and 11% (n = 1) for the surgical and endovascular groups, respectively. An adherent, occlusive thrombus was found in all four of the remaining surgically treated animals and in six of eight animals treated percutaneously. The IVC remained patent in two animals in whom balloon migration occurred. Severe caval stenosis invariably occurred after surgical banding. CONCLUSION: IVC thrombi suitable for the study of various recanalization therapies can be reliably created with this pig model.


Assuntos
Modelos Animais de Doenças , Tromboflebite/terapia , Angioplastia com Balão/instrumentação , Animais , Feminino , Suínos , Veia Cava Inferior/patologia
20.
Acta Radiol ; 40(5): 545-51, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10485246

RESUMO

PURPOSE: To assess the efficacy of the Spring filter during interventional treatment of deep venous thrombosis in vivo. MATERIAL AND METHODS: A model of inferior vena cava thrombosis was used. Part I: The thrombus was treated by the pulse-spray technique (PT) (urokinase 250,000 IU; n=7) or a rotatory basket catheter, Thrombolizer (MT) (activated with compressed air at 7 atm; n=5). Part II: Following placement of a Spring filter, the animal underwent PT (n=5) or MT (n=5). Based on the results of part I, the treatment protocol was modified (PT, urokinase 500,000 IU; MT, compressed air at 8 atm). Embolus volumes trapped by the filter and found in the lungs were calculated and the filtering efficacy quantified. RESULTS: Part I: Pulmonary emboli (1 to 4 mm in diameter) were observed in 3 animals in the PT group and 1 animal in the MT group, respectively. Median reduction in thrombus volume was 21% and 4% by PT and MT, respectively. Part II: In the PT group, 58% and 100% of the total embolus load was trapped in 2 animals, while the filter failed to trap emboli (1 to 1.5 mm in diameter) in 1 animal. In the remaining 2 animals, no embolus was found trapped by the filter or in the lungs. In the MT group, 55 97% (median 83%) of the embolus load was trapped. Emboli found in the lungs did not exceed 4 mm in diameter. CONCLUSION: Preceding interventional treatment of venous thrombosis with placement of the Spring filter reduced the embolic burden on the lungs.


Assuntos
Embolia Pulmonar/prevenção & controle , Trombectomia/métodos , Terapia Trombolítica/métodos , Filtros de Veia Cava , Veia Cava Inferior , Trombose Venosa/terapia , Angiografia , Animais , Modelos Animais de Doenças , Feminino , Fibrinolíticos/administração & dosagem , Injeções Intravenosas , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Suínos , Resultado do Tratamento , Trombose Venosa/complicações , Trombose Venosa/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA