Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Thyroid ; 16(12): 1273-8, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17199438

RESUMO

OBJECTIVE: To investigate the usefulness of whole body scan (WBS) and serum thyroglobulin (Tg) measurement after thyroxine withdrawal during sequential follow-ups in patients with differentiated thyroid cancer (DTC). DESIGN: Two hundred and sixty-five consecutive DTC patients were enrolled. They were previously treated with near-total thyroidectomy and I-131 remnant ablation, without initial metastases or Tg antibodies. All had the first follow-up WBS and serum Tg measurement 6-12 months after initial treatment, and 165 patients received the second follow-up without further therapy. Positive/negative predictive values (PPV/NPV) were calculated by the outcome of patients being followed up for more than 8 years (mean+/-SD: 133+/-26 months). RESULTS: Serum Tg levels while the patients were off thyroxine therapy decreased spontaneously in 39.3% of the cases without further therapy. The NPV of the first follow-up serum Tg level was excellent: <2 microg/L and <0.5 microg/L were 95.1% and 98.2%, respectively. However, the PPV of the first follow-up serum Tg level was low: >10 microg/L and 2-10 microg/L were 40% and 9.6%, respectively. The trend of Tg levels was more informative; the PPV was 62.5% in cases with an increase of serum Tg of >10 microg/L and 16.6% with an increase of <5 microg/L. However, decreasing Tg levels may associate with rapid deterioration of disease, in which cases decrease of Tg indicated dedifferentiation of the tumor. The diagnostic WBS showed the same picture in 91.5% of the patients. Only one patient (0.6%) turned from negative study to positive during the follow-up. In the meanwhile his serum Tg levels increased from 0.56 to 13.6 microg/L. CONCLUSION: It is most informative when both the trend and the levels of Tg during sequential follow-up are considered. The diagnostic WBS may be performed for selected patients with indication based on Tg levels to localize the disease.


Assuntos
Carcinoma Papilar/diagnóstico por imagem , Tireoglobulina/sangue , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Imagem Corporal Total , Adulto , Idoso , Carcinoma Papilar/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica/diagnóstico por imagem , Valor Preditivo dos Testes , Cintilografia , Síndrome de Abstinência a Substâncias , Neoplasias da Glândula Tireoide/terapia , Tiroxina/uso terapêutico
2.
Ophthalmologica ; 219(5): 292-6, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16123556

RESUMO

PURPOSE: To evaluate the sensitivity and specificity of one-field, non-mydriatic, 45 degrees digital photography for screening for diabetic retinopathy compared to indirect ophthalmoscopy using a slit-lamp, the reference standard. METHODS: A total of 100 consecutive diabetic patients (200 eyes) who underwent digital fundus photography and ocular examinations from June 2002 to November 2002 were included in this retrospective study. The patients, recruited from a hospital-based, retina referral practice, underwent 45 degrees, non-mydriatic, digital fundus photography using a non-mydriatic fundus camera. One image was obtained focusing the mid fundus between the optic disc and the macula. The fundus images were printed and graded by endocrinologists and a retinal specialist separately. The patients also underwent complete standard ocular examinations as the reference method for determining diabetic retinopathy, including dilation of their pupils and slit-lamp biomicroscopy done by ophthalmologists. The sensitivity and specificity of the digital photographic method were calculated by comparison to the reference method. RESULTS: The sensitivity and specificity of the retinal specialist's diabetic retinopathy grades were 53.8 and 89.0%, respectively. The sensitivity and specificity of the endocrinologists' grades were 45 and 75.3%, respectively. The false negative rates were 22 and 21.5% for endocrinologists and the retinal specialist, respectively. CONCLUSIONS: Screening for diabetic retinopathy using one-field, non-mydriatic, 45 degrees digital photography is inadequate.


Assuntos
Retinopatia Diabética/diagnóstico , Fotografação/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Reações Falso-Negativas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmoscopia/métodos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA