Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circ J ; 84(3): 411-418, 2020 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-32051386

RESUMO

BACKGROUND: This study investigated the impact of systemic inflammation on bleeding risk in non-valvular atrial fibrillation (NVAF) patients treated with direct oral anticoagulants (DOAC).Methods and Results:We conducted a single-center prospective registry of 2,216 NVAF patients treated with DOAC: the DIRECT registry (UMIN000033283). High-sensitivity C-reactive protein (hsCRP) was measured ≤3 months before (pre-DOAC hsCRP) and 6±3 months after initiation of DOAC (post-DOAC hsCRP). Multivariate logistic regression model was used to assess the influence of systemic inflammation and conventional bleeding risk factors on major bleeding according to International Society on Thrombosis and Haemostasis criteria. Based on the findings, we created a new bleeding risk assessment score: the ORBIT-i score, which included post-DOAC hsCRP >0.100 mg/dL and all components of the ORBIT score. A total of 1,848 patients had both pre- and post-DOAC hsCRP data (follow-up duration, 460±388 days). Post-DOAC hsCRP was associated with major bleeding (OR, 2.770; 95% CI: 1.687-4.548, P<0.001). Patients with post-DOAC hsCRP >0.100 mg/dL more frequently had major bleeding than those without (log-rank test, P<0.001). ORBIT-i score had the highest C-index of 0.711 (95% CI, 0.654-0.769) compared with the ORBIT and HAS-BLED scores. CONCLUSIONS: Persistent systemic inflammation was associated with major bleeding risk. ORBIT-i score had a higher discriminative performance compared with the conventional bleeding risk scores.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/efeitos adversos , Hemorragia/induzido quimicamente , Inflamação/epidemiologia , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , Inibidores do Fator Xa/administração & dosagem , Feminino , Humanos , Inflamação/sangue , Inflamação/diagnóstico , Mediadores da Inflamação/sangue , Japão/epidemiologia , Masculino , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 93(3): 545-552, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30312990

RESUMO

OBJECTIVES: This study reports on the clinical effects of complete vs incompletely revascularized coronary artery disease on transcatheter aortic valve replacement (TAVR). BACKGROUND: There is a high prevalence of active coronary artery disease (CAD) in patients undergoing TAVR but preemptive revascularization remains controversial. METHODS: Patients were categorized into three cohorts: complete revascularization (CR), incomplete revascularization of a major epicardial artery (IR Major), and incomplete revascularization of a minor epicardial artery only (IR Minor). When feasible, SYNTAX scoring was performed for exploratory analysis. Analyses were performed using Cox proportional hazard models and Kaplan-Meier method. RESULTS: A total of 323 patients with active CAD were included. Adjusted outcomes showed that patients with IR Major had increased incidence of acute myocardial infarction (AMI) or revascularization compared with those in the CR cohort (HR 3.72, P = 0.048). No difference was noted in all-cause mortality or all-cause readmission rates. Exploratory secondary analysis with residual SYNTAX scores showed a significant interaction between disease burden and AMI/revascularization, as well as all-cause readmission. All-cause mortality remained unaffected based on residual SYNTAX scores. CONCLUSIONS: This is a retrospective single-center study reporting on pre-TAVR revascularization outcomes in patients with active CAD. In this analysis, we found that patients undergoing TAVR benefited from achieving complete revascularization to abate future incidence of AMI/revascularization. Despite this finding, all-cause mortality remained unaffected. Future efforts should focus on the role of functional assessment of the coronaries, as well as the long-term effects of complete revascularization in a larger patient cohort.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico , Doença da Artéria Coronariana/terapia , Artéria Femoral , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Causas de Morte , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Readmissão do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
3.
Circ J ; 83(7): 1600-1606, 2019 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-31118365

RESUMO

BACKGROUND: Little is known about late outcomes after transcatheter aortic valve replacement (TAVR) in dialysis patients.Methods and Results:We enrolled 25 dialysis patients (mean age 76.5 years; mean STS score 14.7%; men 60.0%) with aortic valve stenosis undergoing TAVR at our institute. Cardiovascular mortality and stroke were defined according to the VARC-2 criteria, and major adverse cardiac and cerebrovascular events (MACCE) were investigated. Twenty-three patients (92.0%) were discharged, and the median hospital stay after TAVR was 9 days (IQR, 7.5-11 days). Mortality at 30 days was not observed. The overall survival rate at 1 and 3 years were 80.0% and 55.7%, respectively (follow-up period, 879±493 days; range, 40-1,826 days). At 1 and 3 years, rates of freedom from cardiovascular mortality, disabling stroke, and MACCE were 100% and 83.0%, 91.2% and 84.7%, and 69.8% and 39.9%, respectively. Three patients required redo-TAVR for valve dysfunction at 23, 36, and 38 months after the first TAVR, respectively (The rate of freedom from severe structural valve deterioration at 1 and 3 years was 100% and 85.9%, respectively). CONCLUSIONS: Satisfactory in-hospital outcomes were achieved in dialysis patients after TAVR. Various problems, however, such as complications particular to dialysis patients and valve durability, remained at midterm follow-up. Further studies are recommended to solve these problems, and prudent preoperative assessments should be mandatory.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Taxa de Sobrevida , Fatores de Tempo
5.
Circ J ; 81(3): 397-404, 2017 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-28123149

RESUMO

BACKGROUND: Dual antiplatelet therapy (DAPT) is commonly used after transcatheter aortic valve implantation (TAVI); however, the supporting evidence is limited. To determine if aspirin alone is a better alternative to DAPT, we compared the outcomes of patients treated with DAPT or aspirin alone after TAVI.Methods and Results:We analyzed a total of 144 consecutive patients (92 females, mean age 83±6 years) who underwent implantation of a balloon-expandable transcatheter valve (SAPIEN or SAPIEN XT, Edwards Lifesciences). Patients were divided into DAPT (n=66) or aspirin-alone treatment groups (n=78). At 1 year after TAVI, the composite endpoint, which consisted of all-cause death, myocardial infarction, stroke, and major or life-threatening bleeding complications, occurred significantly less frequently (Kaplan-Meier analysis) in the aspirin-alone group (15.4%) than in the DAPT group (30.3%; P=0.031). Valve function assessed by echocardiography was similar between the 2 treatment groups with respect to effective orifice area (1.78±0.43 cm2in DAPT vs. 1.91±0.46 cm2in aspirin-alone group; P=0.13) and transvalvular pressure gradient (11.1±3.5 mmHg in DAPT vs. 10.3±4.1 mmHg in aspirin-alone group; P=0.31). CONCLUSIONS: Treatment with aspirin alone after TAVI had greater safety benefits and was associated with similar valve function as DAPT. These results suggest that treatment with aspirin alone is an acceptable regimen for TAVI patients.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/cirurgia , Aspirina/administração & dosagem , Bioprótese , Próteses Valvulares Cardíacas , Inibidores da Agregação Plaquetária/administração & dosagem , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/terapia , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Taxa de Sobrevida
6.
Circ J ; 79(12): 2713-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26460887

RESUMO

BACKGROUND: Although transcatheter aortic valve implantation (TAVI) is a new alternative treatment with acceptable midterm results for high surgical risk patients, at present performing the procedure in dialysis patients is not reimbursed in Japan. METHODS AND RESULTS: The study group of 17 dialysis patients (mean age, 76.7±5.0 years) underwent TAVI with the SAPIEN/SAPIEN XT. EuroSCORE and STS score were 25.0±19.0% and 15.4±12.3%, respectively. Transiliofemoral and transapical approaches were performed in 7 (41.2%) and 10 patients (58.8%), respectively. ICU and hospital stays after TAVI were 1.8±1.6 and 12.9±12.7 days, respectively. Mean transvalvular gradients at discharge significantly decreased from 45.9±13.3 mmHg to 10.7±4.3 mmHg (P<0.0001) and effective orifice area significantly increased from 0.78±0.17 to 1.69±0.37 cm(2)(P<0.0001). Device success was 87.5%. One patient required a valve-in-valve procedure on 187-postoperative-day for an acute increase in paravalvular leakage caused by initial lower implantation of the device. The overall mortality at 1 year was 0% and clinical efficacies at 30 days, 6 months, and 1 year were 93.8%, 83.3%, and 69.2%, respectively. CONCLUSIONS: Satisfactory early results were achieved with TAVI in Japanese dialysis patients with a high surgical risk, indicating it is a safe and effective alternative for the treatment of aortic valve stenosis in such patients.


Assuntos
Estenose da Valva Aórtica/terapia , Falência Renal Crônica/terapia , Diálise Renal , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Povo Asiático , Feminino , Seguimentos , Humanos , Japão , Falência Renal Crônica/complicações , Masculino
7.
Circ J ; 79(5): 1037-43, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25740501

RESUMO

BACKGROUND: Feasibility and early results of transfemoral aortic valve implantation using the ACURATE neo/TF(TM)self-expanding stent are reported. METHODS AND RESULTS: The study group of 15 patients (mean age 83.3±6.0) was enrolled with a mean EuroSCORE and STS score of 21.9±11.6% and 7.5±3.1%, respectively. Clinical and echocardiographic evaluations were performed at baseline, discharge, 30 days and 6 months. The primary endpoint was all-cause mortality at 30 days. Transcatheter aortic valve implantation (TAVI) using the ACURATE neo/TF device was successful in 14 patients; 1 patient underwent valve-in-valve implantation because the prosthetic valve embolized during withdrawal of the delivery system. Conversion to surgery, coronary obstruction, peri-operative stroke, and pacemaker implantation did not occur at 30 days. Mean transvalvular gradients at discharge significantly decreased from 44.2±10.5 mmHg (preprocedural) to 7.7±3.1 mmHg (P<0.0001) and effective orifice area significantly increased from 0.77±0.12 to 1.69±0.25 cm(2)(P<0.0001). None or trace paravalvular leak was revealed in 50.0%, and no patient exhibited moderate or higher paravalvular leak. The overall mortality at 30 days and 6 months was 0% and 6.7%, respectively. CONCLUSIONS: A new self-expanding TF TAVI device, ACURATE neo/TF, is safe and effective in the treatment of severe aortic stenosis in elderly patients at high risk for surgery.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino
8.
J Echocardiogr ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38451414

RESUMO

BACKGROUND: Dilated cardiomyopathy (DCM) presents with diverse clinical courses, hardly predictable solely by the left ventricular (LV) ejection fraction (EF). Longitudinal strain (LS) offers distinct information from LVEF and exhibits various distribution patterns. This study aimed to evaluate the clinical significance of LS distribution patterns in DCM. METHODS: We studied 139 patients with DCM (LVEF ≤ 35%) who were admitted for heart failure (HF). LS distribution was assessed using a bull's eye map and the relative apical LS index (RapLSI), calculated by dividing apical LS by the sum of basal and mid-LS values. We evaluated the associations of LS distribution with cardiac events (cardiac death, LV assist device implantation, or HF hospitalization) and LV reverse remodeling (LVRR), as indicated by subsequent LVEF changes. RESULTS: Twenty six (19%) and 29 (21%) patients exhibited a pattern of relatively apical impaired or preserved LS (defined by RapLSI < 0.25 or > 0.75, signifying a 50% decrease or increase in apical LS compared to other segments), and the remaining patients exhibited a scattered/homogeneously impaired LS pattern. The proportion of new-onset heart failure and LVEF differed between the three groups. During the median 595-day follow-up, patients with relatively-impaired apical LS had a higher rate of cardiac events (both log-rank p < 0.05) and a lower incidence of LVRR (both p < 0.01) compared to patients with other patterns. RapLSI was significantly associated with cardiac event rates after adjusting for age, sex, and new-onset HF or global LS. CONCLUSION: DCM patients with reduced EF and distinct distribution patterns of impaired LS experienced different outcomes.

9.
Clin Case Rep ; 12(2): e8463, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38314190

RESUMO

Key Clinical Message: Left atrial posterior wall on the vertebra is often difficult to obtain stable tissue contact with ablation-catheter. Laser balloon ablation is effective because the compression from the vertebra can be visualized through endoscopy. Abstract: When performing pulmonary vein isolation (PVI) with radiofrequency, left atrial posterior wall on the vertebra is often difficult to obtain stable tissue contact with ablation-catheter because of the movement of the ablation point. Laser balloon ablation is effective for the achievement of durable PVI in cases with such anatomical characteristics because the compression from the vertebra can be visualized through endoscopy.

10.
J Card Surg ; 28(4): 373-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23879340

RESUMO

BACKGROUND: Even mild paravalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) is associated with increased late mortality. Electrocardiogram-gated multi-slice computed tomography (MSCT) enables detailed aortic annulus assessment. We describe the impact of MSCT for PVL following TAVR. METHODS: Congruence between the prosthesis and annulus diameters affects PVL; therefore, we calculated the OverSized AortiC Annular ratio (OSACA ratio) and OSACA (transesophageal echocardiography, TEE) ratio as prosthesis diameter/annulus diameter on MSCT or TEE, respectively, and compared their relationship with PVL ≤ trace following TAVR. RESULTS: Of 36 consecutive patients undergoing TAVR (Group A), the occurrence of PVL ≤ trace (33.3%) was significantly related to the OSACA ratio (p = 0.00020). In receiver-operating characteristics analysis, the cutoff value of 1.03 for the OSACA ratio had the highest sum of sensitivity (75.0%) and specificity (91.7%; AUC = 0.87) with significantly higher discriminatory performance for PVL as compared to the OSACA (TEE) ratio (AUC = 0.69, p = 0.028). In nine consecutive patients (Group B) undergoing TAVR based on guidelines formulated from our experience with Group A, PVL ≤ trace was significantly more frequent (88.9%) than that in Group A (p = 0.0060). CONCLUSIONS: The OSACA ratio has a significantly higher discriminatory performance for PVL ≤ trace than the OSACA (TEE) ratio, and aortic annular measurement from MSCT is more accurate than that from TEE.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Eletrocardiografia/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores/métodos , Complicações Pós-Operatórias , Desenho de Prótese/efeitos adversos , Desenho de Prótese/métodos , Falha de Prótese/etiologia , Ajuste de Prótese/efeitos adversos , Ajuste de Prótese/métodos , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Estudos Retrospectivos
11.
Intern Med ; 62(14): 2085-2088, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-36418104

RESUMO

Peripartum cardiomyopathy (PPCM) is a left ventricular systolic dysfunction associated with heart failure (HF) in late-term pregnancy or peripartum. A 29-year-old pregnant woman with no history of cardiac disease noted lower extremity edema around 34 weeks' gestation with significant weight gain. She delivered twins via caesarean section, and the edema regressed postpartum. On postpartum day 4, however, she experienced difficulty breathing at night and was diagnosed with HF owing to PPCM. HF treatment along with cabergoline was initiated. With low prolactin blood levels, her symptoms and cardiac function improved over time. This case demonstrated the usefulness of anti-prolactin therapy with cabergoline in PPCM.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Complicações Cardiovasculares na Gravidez , Transtornos Puerperais , Gravidez , Feminino , Humanos , Adulto , Cabergolina/uso terapêutico , Cesárea , Período Periparto , Cardiomiopatias/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/etiologia , Transtornos Puerperais/diagnóstico , Transtornos Puerperais/tratamento farmacológico , Complicações Cardiovasculares na Gravidez/tratamento farmacológico , Complicações Cardiovasculares na Gravidez/diagnóstico
12.
J Heart Lung Transplant ; 41(7): 877-885, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35400587

RESUMO

BACKGROUND: Detailed morphological characteristics of de novo and donor-transmitted plaques and the association of serum T-lymphocyte cytokine levels with plaque progression of coronary allograft vasculopathy within 1 year after heart transplantation are unknown. METHODS: In this retrospective analysis of data in a prospectively maintained database, 40 heart transplant recipients were included. We performed serial 3 vessel optical coherence tomography and intravascular ultrasound analyses, at the 8 week (baseline) and 12 month post-transplantation follow-ups, and serum cytokine measurements (n = 23). The correlation between serum cytokines and Δplaque burden (between baseline and follow-up) was evaluated depending on plaque morphology. RESULTS: Thirteen de novo plaques (maximum intimal thickness ≥0.5 mm at the 12 month follow-up without plaques at baseline) were identified in 8 recipients, and 31 donor-transmitted plaques (maximum intimal thickness ≥0.5 mm at baseline) were detected in 17 recipients. Compared with donor-transmitted plaques, the Δplaque burden in the de novo plaques, with mainly fibrous morphology, was high (38.8% [29.6%-41.2%] vs 8.7% [1.33%-13.6%], p < 0.001). Stratification of the morphology of donor-transmitted plaques revealed that the Δplaque burden in fibrous plaques (10.6% [7.0%-18.0%]) was similar to that in fibroatheroma (10.3% [8.7%-23.8%]). Serum interleukin-31 levels at baseline correlated with fibrous plaque proliferation (r = 0.73, p = 0.007) even under immunosuppressive conditions, whereas other cytokines (interleukin-1ß, interleukin-17, and interferon-gamma) were mostly undetectable. CONCLUSIONS: Intimal fibrous proliferation contributed to the progression of donor-transmitted and de novo plaques. Serum interleukin-31 levels at baseline may contribute to intimal fibrous proliferation within 1 year after heart transplantation.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Placa Aterosclerótica , Aloenxertos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/imunologia , Citocinas/imunologia , Transplante de Coração/efeitos adversos , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/etiologia , Placa Aterosclerótica/imunologia , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/métodos
13.
J Am Heart Assoc ; 11(7): e023276, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35377181

RESUMO

Background Stent thrombosis (ST) remains a significant medical issue. In particular, longer-term mortality and clinical predictors after ST occurrence have yet to be elucidated. Methods and Results This was a multicenter, retrospective, observational study. A total of 187 definite ST cases from January 2008 to December 2017 were enrolled, and the long-term clinical outcomes were investigated. The primary outcome measure was the cumulative mortality after ST occurrence. In addition, independent predictors of mortality were assessed. Among the stent types causing ST, bare-metal stent, first-generation drug-eluting stent, second-generation drug-eluting stent, and third-generation drug-eluting stent comprised 31.0%, 19.3%, 36.9%, and 6.4% of cases, respectively. Median duration from stent implantation to ST was 680.5 (interquartile range, 33.8-2450.5) days. Cumulative mortality was 14.6%, 17.4%, 21.2%, 24.4%, and 33.8% at 1, 2, 3, 5 and 10 years, respectively. The cumulative mortality did not significantly differ by type of stent, and mortality of late ST was higher than that of early ST and very late ST; however, it did not reach statistical significance after the multivariate analysis. Independent predictors of mortality were hemodialysis (hazard ratio [HR], 7.80; 95% CI, 3.07-19.81; P<0.001), culprit lesions in the left main trunk (HR, 8.14; 95% CI, 1.71-38.75; P=0.008), culprit lesions in the left coronary artery (HR, 2.77; 95% CI, 1.10-6.96; P=0.030), and peak creatine kinase (HR, 1.017; 95% CI, 1.011-1.022; P<0.001). Conclusions The 10-year cumulative mortality after ST reached 33.8%. Close follow-up is thus mandatory for patients with ST, especially with hemodialysis, culprit lesions in the left main trunk and left coronary artery, and high peak creatine kinase.


Assuntos
Trombose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Trombose , Trombose Coronária/etiologia , Stents Farmacológicos/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Trombose/epidemiologia , Resultado do Tratamento
14.
J Cardiol Cases ; 24(4): 169-172, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35059050

RESUMO

In the drug-eluting stent era, stent thrombosis is uncommon but still a life-threatening complication after percutaneous coronary intervention. There are several types of risk factors associated with stent thrombosis, which could work synergistically to produce thrombus. We report the case of subacute stent thrombosis. A 66-year-old male was hospitalized due to ST-segment elevation myocardial infarction and received emergency percutaneous coronary intervention to the obtuse marginal branch and the posterolateral artery. Five days later, he complained of chest pain. Emergency coronary angiography was performed and revealed stent thromboses in both the obtuse marginal branch and the posterolateral artery. Remarkably, in this case, stent thromboses occurred in the obtuse marginal branch and the posterolateral artery simultaneously. Finally, we overcame this situation by stenting to the main branch of left circumflex artery. We speculated the precise mechanism of simultaneously occurring two subacute stent thromboses through multiple intracoronary imaging modalities. In this case, we hypothesized that the combination of the protrusion of obtuse marginal branch stent to the main branch of left circumflex artery, blood flow turbulence due to the ulcer, and relatively high thrombogenicity of acute coronary syndrome lesion synergistically generated the thrombus. .

15.
Intern Med ; 59(23): 3045-3049, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32759592

RESUMO

A 76-year-old man developed repeated fulminant myocarditis in a short period, and immunosuppressive therapy was remarkably effective. A pathologic evaluation showed that inflammatory cells had infiltrated the myocardium. Not only invasion of inflammatory cells but also the formation of lymphoid follicle was noted. Chronic myocardial inflammation was proven, but cardiac sarcoidosis was negative according to the results of various examinations. This is the first report of recurrent autoimmune myocarditis with a lymphoid follicle in the myocardium. These findings may suggest a novel pathogenesis of myocarditis.


Assuntos
Imunoterapia/métodos , Miocardite/complicações , Miocardite/fisiopatologia , Miocardite/terapia , Miocárdio/patologia , Estruturas Linfoides Terciárias/etiologia , Estruturas Linfoides Terciárias/fisiopatologia , Estruturas Linfoides Terciárias/terapia , Idoso , Humanos , Masculino , Recidiva , Resultado do Tratamento
16.
Cardiovasc Revasc Med ; 21(8): 1034-1040, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31992532

RESUMO

Device iterations and technical refinements have enabled transcatheter aortic valve implantation (TAVI) to be offered as a routine interventional procedure in many centers with high reproducibility and success. The concept of a streamlined procedure with appropriate procedural optimization, namely "optimized approach," has become increasingly relevant, aimed at minimizing perioperative burden and promoting early recovery. Relatively high device costs may be mitigated by reducing length of hospital stay and resource utilization. This review summarizes current evidence of components related to the optimization process during transfemoral TAVI. It is important to customize the procedure specific to each patient for its optimization.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Periférico , Artéria Femoral , Doenças das Valvas Cardíacas/cirurgia , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Medicina Baseada em Evidências , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Segurança do Paciente , Complicações Pós-Operatórias/etiologia , Punções , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
J Invasive Cardiol ; 32(5): 186-193, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32160153

RESUMO

OBJECTIVES: We share our center's experience with the use of transcatheter valvular therapies in the setting of failed bioprostheses. BACKGROUND: As medicine continues to advance, the lifespan of individuals continues to increase, and current surgical valvular therapies begin to degrade prior to a person's end of life. It is important to evaluate the efficacy and durability of transcatheter valves within failed surgical bioprostheses. METHODS: Baseline characteristics, periprocedural complications, and long-term outcomes were collected and assessed in patients who received transcatheter valves for failing surgical aortic valve bioprostheses and mitral valve and ring bioprostheses from March 2011 to July 2018. RESULTS: From our cohort of 1048 patients, we identified 45 individuals (4.3%) who underwent transcatheter replacement of a failed bioprosthetic valve or ring. Mean age at presentation was 80.8 ± 10.7 years and 75.5 ± 9.3 years, mean STS score was 9.3 ± 5.1 and 13.3 ± 8.7, and mean time to failure was 12.0 ± 5.2 years and 7.3 ± 4.5 years for aortic and mitral positions, respectively. At 1 year, time to event analysis suggested a 16.4% mortality rate for aortic replacement and 12.8% mortality rate for mitral replacement. CONCLUSIONS: We demonstrate outcomes from one of the largest single-center United States based cohorts of transcatheter replacements of failed surgical bioprostheses. Our center has demonstrated that it is feasible to pursue the replacement of failed surgical bioprostheses in the aortic and mitral positions with transcatheter valves given appropriate patient selection.


Assuntos
Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Circ Rep ; 1(3): 142-148, 2019 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-33693129

RESUMO

Background: The outcome of redo transcatheter aortic valve (TAV) implantation (TAVI) is unknown for TAV structural valve degeneration (SVD). This paper reports the initial results of redo TAVI for TAV-SVD in Japanese patients. Methods and Results: Of 630 consecutive patients, 6 (1.0%) underwent redo TAVI for TAV-SVD (689-1,932 days after the first TAVI). The first TAV were 23-mm balloon-expandable valves (BEV, n=5) and a 26-mm self-expandable valve (SEV, n=1). All patients underwent multidetector computed tomography (MDCT) before redo TAVI, which showed first-TAV under-expansion (range, 19.1-21.0 mm) compared with the label size. Two BEV and 4 SEV were successfully implanted as second TAV, without moderate/severe regurgitation or 30-day mortality. One of 2 patients with a BEV-inside-BEV implantation had a high transvalvular mean pressure gradient post-procedurally (34 mmHg) and required surgical valve replacement 248 days after the redo TAVI. This, however, was unnoted in patients with SEV implantation during redo TAVI. Planned coronary artery bypass grafting was concomitantly performed in 1 patient with a small sino-tubular junction and SEV-inside-SEV implantation because of the risk of coronary malperfusion caused by the first TAV leaflets. Five of the 6 patients survived during the follow-up period (range, 285-1,503 days). Conclusions: Redo TAVI for TAV-SVD appears safe and feasible, while specific strategies based on MDCT and device selection seem important for better outcomes.

20.
Am J Cardiol ; 124(4): 573-579, 2019 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-31255236

RESUMO

Few studies have evaluated transcatheter aortic valve implantation (TAVI) beyond 5 years. We investigated long-term outcomes (≥5 years) and transcatheter heart valve (THV) performance in patients who had undergone TAVI at least 5 years previously, based on annual follow-up. We reviewed 114 consecutive patients who were of high surgical risk or inoperable and underwent TAVI for severe aortic stenosis from October 2009 to November 2013. There was no lost to follow-up, and median time to death or latest follow-up was 5.0 years (range: 0.1 to 8.5). Structural valve degeneration (SVD) was defined on transthoracic echocardiography (TTE) as follows: (1) mean pressure gradient ≥20 mm Hg with a >10 mm Hg increase from the post-TAVI baseline, and/or (2) moderate or severe transvalvular regurgitation. The mean patient age was 82.7 ± 6.4 years, and 37.7% of patients were men. Median Society of Thoracic Surgeons score was 7.6% (interquartile range 5.8 to 10.9). TTE ≥5 years was 76.1% complete (51 of 67 patients who survived ≥5 years postoperatively). The estimated cumulative survival rates at 1, 3, 5, and 7 years were 88.6%, 72.8%, 58.8%, and 45.3%, respectively. Albumin <3.5 g/dl was strongly associated with increased long-term mortality on multivariate analysis. Longitudinal TTE confirmed durable performance of THV up to 7 years in the majority of patients; however, 6 patients (5.3% of the total cohort) experienced SVD during the follow-up. In conclusion, this study demonstrated favorable long-term survival and stable THV performance after TAVI, although SVD was not rare.


Assuntos
Estenose da Valva Aórtica/cirurgia , Avaliação de Resultados em Cuidados de Saúde , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Feminino , Humanos , Japão , Masculino , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA