Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39271165

RESUMO

OBJECTIVES: Physician's evaluation of interstitial lung disease (ILD) extension with high-resolution computed tomography (HRCT) has limitations such as lack of objectivity and reproducibility. This study aimed to investigate the utility of computer-based deep-learning analysis using QZIP-ILD® software (DL-QZIP) compared with conventional approaches in connective tissue disease (CTD) -related ILD. METHODS: Patients with CTD-ILD visiting our Rheumatology Centre between December 2020 and April 2024 were recruited. Quantitative scores, including the percentage of lung involvement in ground-glass opacity (QGG), total fibrotic lesion (QFIB), and overall ILD extension encompassing both QGG and QFIB (QILD), calculated by DL-QZIP, were compared with semiquantitative visual method, employing intraclass correlation coefficients (ICC). We compared the capability of QILD scores to distinguish patients with forced vital capacity (FVC) % <70 in both methods determined by the area under the curve (AUC) by the receiver-operating characteristic curve analysis and DeLong's test. RESULTS: Eighty patients (median age, 66 years; 14 men) were included. Median QGG, QFIB, and QILD scores were 3.45%, 2.19%, and 5.35% using DL-QZIP, and 3.25%, 4.06%, and 8.48% using visual method, respectively. Correlations between DL-QZIP and visual method were 0.75 for QGG, 0.61 for QFIB, and 0.75 for QILD. The AUC of QILD scores for FVC% <70 was significantly higher with DL-QZIP (0.833) compared with visual method (0.660) (p < 0.01). CONCLUSION: QZIP-ILD® demonstrates superior capability in distinguishing patients with a radiological scenario correlated to severe physiological impairment, while showing relatively good correlations in quantifying the extent on HRCT compared with conventional method in CTD-ILD.

2.
J Minim Invasive Gynecol ; 31(5): 445-452, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38417674

RESUMO

STUDY OBJECTIVE: To assess the impact visceral adipose tissue percentage (VAT%) on surgical outcomes during minimally invasive surgery in obese women with endometrial cancer. DESIGN: Retrospective observational cohort study. SETTING: Mie University Hospital, Japan. PATIENTS: Of the 73 women (body mass index [BMI] >30 kg/m2) with obesity and primary endometrial cancer, 52 underwent robotic surgery, while 21 underwent laparoscopic surgery between April 2014 and December 2022. INTERVENTIONS: We investigated the correlation between surgical outcomes (operative time and blood loss) and obesity (BMI and visceral adipose tissue percentage [VAT%]). MEASUREMENTS AND MAIN RESULTS: Abdominal fat-related parameters were measured at the level of the umbilicus using preoperative computed tomography. A weak negative correlation was found between BMI and VAT% (CC = -0.313, p = .001). Multivariate analysis showed that VAT% had a stronger correlation to total and practical operative time than BMI (ß = 0.338 vs 0.267, ß = 0.311 vs 0.209, respectively) and was an independent predictor of blood loss. VAT% was an independent predictive marker prolonged for operative time and increased blood loss during lymphadenectomy. CONCLUSION: VAT% could be an indicator of surgical outcomes for patients with obesity and endometrial cancer.


Assuntos
Índice de Massa Corporal , Neoplasias do Endométrio , Gordura Intra-Abdominal , Laparoscopia , Obesidade , Duração da Cirurgia , Humanos , Feminino , Neoplasias do Endométrio/cirurgia , Neoplasias do Endométrio/patologia , Neoplasias do Endométrio/complicações , Gordura Intra-Abdominal/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Obesidade/complicações , Idoso , Laparoscopia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Perda Sanguínea Cirúrgica , Resultado do Tratamento , Japão/epidemiologia , Excisão de Linfonodo/métodos
3.
Surg Today ; 54(8): 953-963, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38581555

RESUMO

PURPOSE: Predicting nonalcoholic fatty liver disease (NAFLD) following pancreaticoduodenectomy (PD) is challenging, which delays therapeutic intervention and makes its prevention difficult. We conducted this study to assess the potential application of preoperative computed tomography (CT) radiomics for predicting NAFLD. METHODS: The subjects of this retrospective study were 186 patients with PD from a single institution. We extracted the predictors of NAFLD after PD statistically from conventional clinical and radiomic features of the estimated remnant pancreas and whole liver region on preoperative nonenhanced CT images. Based on these predictors, we developed a machine-learning predictive model, which integrated clinical and radiomic features. A comparative model used only clinical features as predictors. RESULTS: The incidence of NAFLD after PD was 43.5%. The variables of the clinicoradiomic model included one shape feature of the pancreas, two texture features of the liver, and sex; the variables of the clinical model were age, sex, and chemoradiotherapy. The accuracy%, precision%, recall%, F1 score, and area under the curve of the two models were 75.0, 72.7, 66.7, 69.6, and 0.80; and 69.6, 68.4, 54.2, 60.5, and 0.69, respectively. CONCLUSIONS: Preoperative CT-derived radiomic features from the pancreatic and liver regions are promising for the prediction of NAFLD post-PD. Using these features enhances the predictive model, enabling earlier intervention for high-risk patients.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Pancreaticoduodenectomia , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X , Humanos , Pancreaticoduodenectomia/efeitos adversos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/etiologia , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Idoso , Aprendizado de Máquina , Valor Preditivo dos Testes , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Adulto , Fígado/diagnóstico por imagem , Fígado/patologia , Período Pré-Operatório , Incidência , Idoso de 80 Anos ou mais , Radiômica
4.
J Digit Imaging ; 36(5): 2313-2321, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37322307

RESUMO

This study aims to determine the effect of Gaussian filter size for CT-based attenuation correction (CTAC) on the quantitative assessment of bone SPECT. An experiment was performed using a cylindrical phantom containing six rods, of which one was filled with water and five were filled with various concentrations of K2HPO4 solution (120-960 mg/cm3) to simulate different bone densities. 99mTc-solution of 207 kBq/ml was also included within the rods. SPECT data were acquired at 120 views for 30 s/view. CT for attenuation correction were obtained at 120 kVp and 100 mA. Sixteen different CTAC maps processed with different Gaussian filter sizes (ranging from 0 to 30 mm in 2 mm increments) were generated. SPECT images were reconstructed for each of the 16 CTAC maps. Attenuation coefficients and radioactivity concentrations in the rods were compared with those in the water-filled rod without K2HPO4 solution as a reference. Gaussian filter sizes below 14-16 mm resulted in an overestimation of radioactivity concentrations for rods with high concentrations of K2HPO4 (≥ 666 mg/cm3). The overestimation of radioactivity concentration measurement was 3.8% and 5.5% for 666 mg/cm3 and 960 mg/cm3 K2HPO4 solutions, respectively. The difference in radioactivity concentration between the water rod and the K2HPO4 rods was minimal at 18-22 mm. The use of Gaussian filter sizes smaller than 14-16 mm caused an overestimation of radioactivity concentration in regions of high CT values. Setting the Gaussian filter size to 18-22 mm enables radioactivity concentration to be measured with the least influence on bone density.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Osso e Ossos/diagnóstico por imagem , Densidade Óssea , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador
5.
J Digit Imaging ; 36(4): 1578-1587, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36944812

RESUMO

The purpose is to evaluate whether deep learning-based denoising (DLD) algorithm provides sufficient image quality for abdominal computed tomography (CT) with a 30% reduction in radiation dose, compared to standard-dose CT reconstructed with conventional hybrid iterative reconstruction (IR). The subjects consisted of 50 patients who underwent abdominal CT with standard dose and reconstructed with hybrid IR (ASiR-V50%) and another 50 patients who underwent abdominal CT with approximately 30% less dose and reconstructed with ASiR-V50% and DLD at low-, medium- and high-strength (DLD-L, DLD-M and DLD-H, respectively). The standard deviation of attenuation in liver parenchyma was measured as image noise. Contrast-to-noise ratio (CNR) for portal vein on portal venous phase was calculated. Lesion conspicuity in 23 abdominal solid mass on the reduced-dose CT was rated on a 5-point scale: 0 (best) to -4 (markedly inferior). Compared with hybrid IR of standard-dose CT, DLD-H of reduced-dose CT provided significantly lower image noise (portal phase: 9.0 (interquartile range, 8.7-9.4) HU vs 12.0 (11.4-12.7) HU, P < 0.0001) and significantly higher CNR (median, 5.8 (4.4-7.4) vs 4.3 (3.3-5.3), P = 0.0019). As for DLD-M of reduced-dose CT, no significant difference was found in image noise and CNR compared to hybrid IR of standard-dose CT (P > 0.99). Lesion conspicuity scores for DLD-H and DLD-M were significantly better than hybrid IR (P < 0.05). Dynamic contrast-enhanced abdominal CT acquired with approximately 30% lower radiation dose and generated with the DLD algorithm exhibit lower image noise and higher CNR compared to standard-dose CT with hybrid IR.


Assuntos
Aprendizado Profundo , Humanos , Redução da Medicação , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos
6.
Eur Radiol ; 32(8): 5499-5507, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35238970

RESUMO

OBJECTIVES: To evaluate the usefulness of deep learning image reconstruction (DLIR) to improve the image quality of dual-energy computed tomography (DECT) of the abdomen, compared to hybrid iterative reconstruction (IR). METHODS: This study included 40 patients who underwent contrast-enhanced DECT of the abdomen. Virtual monochromatic 40-, 50-, and 70-keV and iodine density images were reconstructed using three reconstruction algorithms, including hybrid IR (ASiR-V50%) and DLIR (TrueFidelity) at medium- and high-strength level (DLIR-M and DLIR-H, respectively). The standard deviation of attenuation in liver parenchyma was measured as image noise. The contrast-to-noise ratio (CNR) for the portal vein on portal venous phase CT was calculated. The vessel conspicuity and overall image quality were graded on a 5-point scale ranging from 1 (poor) to 5 (excellent). The comparative scale of lesion conspicuity in 47 abdominal solid lesions was evaluated on a 5-point scale ranging from 0 (best) to -4 (markedly inferior). RESULTS: The image noise of virtual monochromatic 40-, 50 -, and 70-keV and iodine density images was significantly decreased by DLIR compared to hybrid IR (p < 0.0001). The CNR was significantly higher in DLIR-H and DLIR-M than in hybrid IR (p < 0.0001). The vessel conspicuity and overall image quality scores were also significantly greater in DLIR-H and DLIR-M than in hybrid IR (p < 0.05). The lesion conspicuity scores for DLIR-M and DLIR-H were significantly higher than those for hybrid IR in the virtual monochromatic image of all energy levels (p ≤ 0.001). CONCLUSIONS: DLIR improves vessel conspicuity, CNR, and lesion conspicuity of virtual monochromatic and iodine density images in abdominal contrast-enhanced DECT, compared to hybrid IR. KEY POINTS: • Deep learning image reconstruction (DLIR) is useful for reducing image noise and improving the CNR of visual monochromatic 40-, 50-, and 70-keV images in dual-energy CT. • DLIR can improve lesion conspicuity of abdominal solid lesions on virtual monochromatic images compared to hybrid iterative reconstruction. • DLIR can also be applied to iodine density maps and significantly improves their image quality.


Assuntos
Aprendizado Profundo , Iodo , Abdome/diagnóstico por imagem , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
7.
J Cardiovasc Magn Reson ; 23(1): 56, 2021 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-33993891

RESUMO

BACKGROUND: Coronary magnetic resonance angiography (CMRA) allows non-ionizing visualization of luminal narrowing in coronary artery disease (CAD). Although a prior study showed the usefulness of CMRA for risk stratification in short-term follow-up, the long-term prognostic value of CMRA remains unclear. The purpose of this study was to evaluate the long-term prognostic value of CMRA. METHODS: A total of 506 patients without history of myocardial infarction or prior coronary artery revascularization underwent free-breathing whole-heart CMRA between 2009 and 2015. Images were acquired using a 1.5 T or 3 T scanner and visually evaluated as the consensus decisions of two observers. Obstructive CAD on CMRA was defined as luminal narrowing of ≥ 50% in at least one coronary artery. Major adverse cardiac events (MACE) comprised cardiac death, nonfatal myocardial infarction, and unstable angina. RESULTS: Obstructive CAD on CMRA was observed in 214 patients (42%). During follow-up (median, 5.6 years), 31 MACE occurred. Kaplan-Meier curve analysis revealed a significant difference in event-free survival between patients with and without obstructive CAD for MACE (log-rank, p = 0.003) and cardiac death (p = 0.012). Annualized event rates for MACE in patients with no obstructive CAD, 1-vessel disease, 2-vessel disease, and left-main or 3-vessel disease were 0.6%, 1.5%, 2.3%, and 3.6%, respectively (log-rank, p = 0.003). Cox proportional hazard regression analysis showed that, among obstructive CAD on CMRA and clinical risk factors (age, sex, hypertension, diabetes, dyslipidemia, smoking, and family history of CAD), obstructive CAD and diabetes were significant predictors of MACE (hazard ratios, 2.9 [p = 0.005] and 2.2 [p = 0.034], respectively). In multivariate analysis, obstructive CAD remained an independent predictor (adjusted hazard ratio, 2.6 [p = 0.010]) after adjusting for diabetes. Addition of obstructive CAD to clinical risk factors significantly increased the global chi-square result from 8.3 to 13.8 (p = 0.022). CONCLUSIONS: In long-term follow-up, free breathing whole heart CMRA allows non-invasive risk stratification for MACE and cardiac death and provides incremental prognostic value over conventional risk factors in patients without a history of myocardial infarction or prior coronary artery revascularization. The presence and severity of obstructive CAD detected by CMRA were associated with worse prognosis. Importantly, patients without obstructive CAD on CMRA displayed favorable prognosis.


Assuntos
Doença da Artéria Coronariana , Angiografia por Ressonância Magnética , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco
8.
J Cardiovasc Magn Reson ; 22(1): 42, 2020 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-32498688

RESUMO

BACKGROUND: Left ventricular (LV) diastolic dysfunction is the main cause of heart failure with preserved ejection fraction (HFpEF), and is characterized by LV stiffness and relaxation. Abnormal LV global longitudinal strain (GLS) is frequently observed l in HFpEF, and was shown to be useful in identifying HFpEF patients at high risk for a cardiovascular event. Cardiovascular magnetic resonance (CMR) feature tracking (CMR-FT) enables the reproducible and non-invasive assessment of global strain from cine CMR images. However, the association between GLS and invasively measured parameters of diastolic function has not been investigated. We sought to determine the prevalence and severity of GLS impairment in patients with HFpEF by using CMR-FT, and to evaluate the correlation between GLS measured by CMR-FT and that measured by invasive diastolic functional indices. METHODS: Eighteen patients with HFpEF and 18 age- and sex-matched healthy control subjects were studied. All subjects underwent cine, pre- and post-contrast T1 mapping and late gadolinium-enhancement CMR. In the HFpEF patients, invasive pressure-volume loops were obtained to evaluate LV diastolic properties. GLS was quantified from cine CMR, and extracellular volume fraction (ECV) was quantified from pre- and post-contrast T1 mapping as a known imaging biomarker for predicting LV stiffness. RESULTS: GLS was significantly impaired in patients with HFpEF (- 14.8 ± 3.3 vs.-19.5 ± 2.8%, p < 0.001). Thirty nine percent (7/18) of HFpEF patients showed impaired GLS with a cut-off of - 13.9%. Statistically significant difference was found in ECV between HFpEF patients and controls (32.2 ± 3.8% vs. 29.9 ± 2.6%, p = 0.044). In HFpEF patients, the time constant of active LV relaxation (Tau) was strongly correlated with GLS (r = 0.817, p < 0.001), global circumferential strain (GCS) (r = 0.539, p = 0.021) and global radial strain (GRS) (r = - 0.552, p = 0.017). Multiple linear regression analysis revealed GLS as the only independent predictor of altered Tau (beta = 0.817, p < 0.001) among age, LV end-diastolic volume index, LV end-systolic volume index, LV mass index, GCS, GRS and GLS. CONCLUSIONS: CMR-FT is a noninvasive approach that enables identification of the subgroup of HFpEF patients with impaired GLS. CMR LV GLS independently predicts abnormal invasive LV relaxation index Tau measurements in HFpEF patients. These findings suggest that feature-tracking CMR analysis in conjunction with ECV, may enable evaluation of diastolic dysfunction in patients with HFpEF.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Estudos de Casos e Controles , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia
9.
Radiology ; 292(3): 628-635, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31287389

RESUMO

BackgroundChange in tumor size at CT is insufficient for reliable assessment of treatment response after neoadjuvant chemotherapy and radiation therapy (CRT) and shows poor correlation with histologic grading of response.PurposeTo investigate the use of perfusion CT to predict the response of pancreatic ductal adenocarcinoma (PDA) to CRT.Materials and MethodsBetween June 2016 and May 2018, study participants with biopsy-proven PDA were prospectively recruited to undergo perfusion CT before and after planned CRT. Blood flow (BF), blood volume (BV), and permeability-surface area product (PSP) were quantified from CT images. Participants were categorized into responders and nonresponders according to therapy response. The Mann-Whitney test was used to compare the baseline perfusion values between responders and nonresponders, and the Wilcoxon matched-pairs signed rank test was used to compare perfusion values before and after CRT.ResultsThe final cohort of 21 participants (median age, 68 years; interquartile range [IQR], 65-72 years; eight men) underwent dynamic perfusion (dual-source) CT before neoadjuvant CRT. All participants underwent pancreatectomy. Eighteen participants underwent post-CRT perfusion CT. Baseline BF was higher in responders (n = 10) than in nonresponders (n = 11) (median, 44 [IQR, 39-56] vs 28 [IQR, 16-52] mL/100 g/min; P = .04), while BV and PSP were similar between groups (median BV, 4.3 [IQR, 3.5-6.9] vs 2.0 [IQR, 1.6-6.5] mL/100 g, P = .15; median PSP, 25 [IQR, 21-30] vs 20 [IQR, 10-34] mL/100 g/min, P = .31). Response Evaluation Criteria in Solid Tumors (RECIST) and carbohydrate antigen (CA) 19-9 showed no correlation with perfusion parameters (eg, RECIST and BF: r = 0.05, P = .84, 95% confidence interval [CI]: -0.40, 0.48; CA 19-9 and BF: r = 0.06, P = .78, 95% CI: -0.39, 0.49) or histopathologic response (r = 0.16, P = .47, 95% CI: -0.3, 0.57 and r = 0.09, P = .71, 95% CI: -0.37, 0.51, respectively). For responders, perfusion parameters increased after CRT (eg, median BF, 54 [IQR, 42-73] vs 43 [IQR, 28-53] mL/100 g/min; P = .04). The perfusion change in nonresponders was not significant (median BF, 43 [IQR, 28-53] vs 33 [IQR, 16-52] mL/100 g/min; P = .06).ConclusionPerfusion CT may be useful in helping predict the histopathologic response to therapy in pancreatic ductal adenocarcinoma.© RSNA, 2019See also the editorial by Sinitsyn in this issue.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/terapia , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/terapia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/terapia , Tomografia Computadorizada por Raios X/métodos , Idoso , Quimiorradioterapia Adjuvante/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Terapia Neoadjuvante/métodos , Pâncreas/diagnóstico por imagem , Pâncreas/efeitos dos fármacos , Pâncreas/efeitos da radiação , Estudos Prospectivos , Resultado do Tratamento
10.
J Nucl Cardiol ; 25(2): 407-415, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-27535413

RESUMO

BACKGROUND: The current study evaluated the usefulness of a belt technique for restricting respiratory motion of the heart and for improving image quality of 13N-ammonia myocardial PET/CT, and it assessed the tolerability of the belt technique in the clinical setting. METHODS: Myocardial 13N-ammonia PET/CT scanning was performed in 8 volunteers on Discovery PET/CT 690 with an optical respiratory motion tracking system. Emission scans were performed with and without an abdominal belt. The amplitude of left ventricular (LV) respiratory motion was measured on respiratory-gated PET images. The degree of erroneous decreases in regional myocardial uptake was visually assessed on ungated PET images using a 5-point scale (0 = normal, 1/2/3 = mild/moderate/severe decrease, 4 = defect). The tolerability of the belt technique was evaluated in 53 patients. RESULTS: All subjects tolerated the belt procedure. The amplitude of the LV respiratory motion decreased significantly with the belt (8.1 ± 7.1 vs 12.1 ± 6.1 mm, P = .0078). The belt significantly improved the image quality scores in the anterior (0.29 ± 0.81 vs 0.71 ± 1.04, P = .015) and inferior (0.33 ± 0.92 vs 1.04 ± 1.04, P < .0001) wall. No adverse events related to the belt technique were observed. CONCLUSIONS: The belt technique restricts LV respiratory motion and improves the image quality of myocardial PET/CT, and it is well tolerated by patients.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Abdome , Adulto , Idoso , Artefatos , Coração/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Radioisótopos de Nitrogênio , Respiração , Tomografia Computadorizada por Raios X
12.
J Cardiovasc Comput Tomogr ; 18(3): 281-290, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38429130

RESUMO

BACKGROUND: The purpose of this study was to investigate the usefulness of second-generation intra-cycle motion correction algorithm (SnapShot Freeze 2, GE Healthcare, MC2) in improving the delineation and interpretability of coronary arteries in coronary computed tomography angiography (CCTA) compared to first-generation intra-cycle motion correction algorithm (SnapShot Freeze, GE Healthcare, MC1). METHODS: Fifty consecutive patients with known or suspected coronary artery disease who underwent CCTA on a 256-slice CT scanner were retrospectively studied. CCTA were reconstructed with three different algorithms: no motion correction (NMC), MC1, and MC2. The delineation of coronary arteries on CCTA was qualitatively rated on a 5-point scale from 1 (nondiagnostic) to 5 (excellent) by two radiologists blinded to the reconstruction method and the patient information. RESULTS: On a per-vessel basis, the delineation scores of coronary arteries were significantly higher on MC2 images compared to MC1 images (median [interquartile range], right coronary artery, 5.0 [4.5-5.0] vs 4.5 [4.0-5.0]; left anterior descending artery, 5.0 [4.5-5.0] vs 4.5 [3.5-5.0]; left circumflex artery, 5.0 [4.5-5.0] vs 4.5 [3.9-5.0]; all p â€‹< â€‹0.05). On a per-segment basis, for both 2 observers, the delineation scores on segment 1, 2, 8, 9, 10, 12 and 13 on MC2 images were significantly better than those on MC1 images (p â€‹< â€‹0.05). The percentage of interpretable segments (rated score 3 or greater) on NMC, MC1, and MC2 images was 90.5-91.9%, 97.4-97.9%, and 100.0%, respectively. CONCLUSION: Second-generation intra-cycle motion correction algorithm improves the delineation and interpretability of coronary arteries in CCTA compared to first-generation algorithm.


Assuntos
Algoritmos , Artefatos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Vasos Coronários , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Humanos , Feminino , Masculino , Angiografia Coronária/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Vasos Coronários/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada Multidetectores , Variações Dependentes do Observador
13.
Arthritis Res Ther ; 26(1): 95, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38704556

RESUMO

OBJECTIVES: Rheumatoid arthritis (RA) related interstitial lung disease (ILD) impacts on the treatment strategy and its prognosis in patients with RA. However, the relationship between RA disease activity and the severity of comorbid ILD has not been fully investigated. This study aimed to investigate the impact of RA disease activity on the severity of comorbid ILD in detail based on currently established visual scoring method along with physiological severity. METHODS: Consecutive patients with RA visiting to our Rheumatology Centre between December 2020 and December 2023 were analysed. The radiological severity of ILD was evaluated by averaging the extent of the combined lesion of ground glass opacity, reticulation and honeycombing in 5% increments in six representative high-resolution computed tomography slices ranging from 0% (no involvement) to 100% (all lung fields affected) according to Goh and Walsh's method. Associations between the radiological and physiological severity of ILD and patients' features were investigated using linear regression analysis. RESULTS: Among 124 patients (32 men, 92 women), the median age was 70 years, and the median disease duration was 2.92 years. Radiological severity of ILD was 0% (without ILD) in 107 (86.2%), ILD with extent < 10% in nine (7.2%), ILD with extent ≥10% and < 20% in three (2.4%), ILD with extent ≥20% in five (4.0%). Both disease activity score (DAS)28-erythrocyte sedimentation rate (ESR) (standardized coefficient = 0.199, P = 0.03) and rheumatoid factor titre (standardized coefficient = 0.247, P = 0.01) were significantly associated with the radiological quantitative severity of ILD in multivariate analysis adjusted for age, sex, disease duration, smoking status and anti-citrullinated peptide antibody titre. DAS28-ESR was significantly associated with forced vital capacity% predicted (standardized coefficient = -0.230, P = 0.047). CONCLUSIONS: Disease activity of RA was significantly associated with the severity of RA-ILD both radiologically and physiologically.


Assuntos
Artrite Reumatoide , Doenças Pulmonares Intersticiais , Índice de Gravidade de Doença , Humanos , Artrite Reumatoide/complicações , Artrite Reumatoide/diagnóstico por imagem , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Idoso de 80 Anos ou mais
14.
Vasc Endovascular Surg ; 58(4): 457-460, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38019846

RESUMO

A 66-year-old man presented with hemolytic anemia, which required frequent blood transfusion, 6 months after surgical repair of an ascending aortic pseudoaneurysm. Hemolysis was attributed to luminal stenosis caused by graft kinking by laboratory test, CT and four-dimensional magnetic resonance imaging. First, an Excluder cuff was placed at the stenotic site under rapid pacing, but it migrated distally. Thereafter a Palmaz XL stent was placed at the stenotic site, which led to resolution of anemia. In this case, a Palmaz XL stent was successfully used to treat hemolytic anemia caused by graft kinking following ascending aortic surgery.


Assuntos
Anemia Hemolítica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Prótese Vascular/efeitos adversos , Resultado do Tratamento , Aorta/diagnóstico por imagem , Aorta/cirurgia , Stents/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Anemia Hemolítica/diagnóstico por imagem , Anemia Hemolítica/etiologia , Procedimentos Endovasculares/efeitos adversos
15.
Radiol Case Rep ; 19(5): 1708-1711, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38384705

RESUMO

Epipericardial fat necrosis (EFN) is a rare benign cause of chest pain, that is frequently overlooked. EFN involves the necrosis of fat tissue in the mediastinum, and presents on computed tomography (CT) as an ovoid lesion of fat attenuation surrounded by a rim of soft tissue attenuation. This case report describes a case of a 50-year-old man diagnosed with EFN on cardiac CT, which was incidentally associated with apical hypertrophic myocardiopathy. Notably, the detection of EFN proved difficult on arterial phase images during coronary CT angiography, whereas it was much easier to detect on delayed phase images. EFN should be considered in the differential diagnosis of chest pain, and careful examination of mediastinal fat is crucial for accurate diagnosis.

16.
J Innov Card Rhythm Manag ; 15(7): 5936-5944, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39011460

RESUMO

The effect of irradiation during computed tomography (CT) imaging on implantable cardioverter-defibrillators (ICDs) has not been fully evaluated in various settings. The purposes of this study were to evaluate the occurrence of electromagnetic interference (EMI) during CT irradiation in various clinically available ICDs with phantom experiments and to determine the potential risks related to irradiation during CT imaging. Five types of clinically available ICDs from five manufacturers were tested. An ICD was combined with an electrocardiogram (ECG) simulator, mounted in a chest phantom, and subjected to CT imaging. Each ICD was irradiated at the maximal power level (tube voltage, 135 kVp; tube current, 510 mA; rotation time, 1.5 s). EMI was defined as oversensing, ventricular tachycardia/ventricular fibrillation (VT/VF) detection, noise, or shock delivery during CT imaging. For ICDs in which EMI was observed, EMI was then evaluated under 144 different irradiation conditions (tube voltage [four patterns from 80-135 kVp], tube current [six patterns from 50-550 mA], and rotation time [six patterns from 0.35-1.5 s]). Testing was also performed during irradiation at the typical doses in three clinical settings and in two settings with inappropriate irradiation of ICDs due to incorrect setup. Among the five ICDs, a shock was delivered by one ICD manufactured by Medtronic (Minneapolis, MN, USA) due to oversensing during irradiation, which occurred at the maximal power level. No oversensing was observed in other ICDs. In the malfunctioned ICD, oversensing was observed in 134 of 144 irradiation patterns, even at a low power in the ICD. The VF-detection criterion was fulfilled in 20 of 134 tests and was significantly associated with tube voltage, tube current, ration time, and tube voltage × rotation time interaction. Although oversensing was observed in three clinical settings (typical chest CT, CT coronary angiography after coronary artery bypass graft, and dynamic assessment for pleural tumors) and one situation during an incorrect scan range on the chest for head perfusion CT, they were not recognized as tachycardia beats. Oversensing was observed when scans were incorrectly set over the ICD during bolus tracking of contrast-enhanced CT. Maximal power CT imaging induced VT/VF detection and shock delivery in one model of ICD placed in a chest phantom. VT/VF detection was observed when tube voltages were high and irradiation times were longer. Oversensing can occur during inappropriate CT imaging, particularly when slices are positioned over the ICD.

17.
J Imaging Inform Med ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39136827

RESUMO

To evaluate the usefulness of low-keV multiphasic computed tomography (CT) with deep learning image reconstruction (DLIR) in improving the delineation of pancreatic ductal adenocarcinoma (PDAC) compared to conventional hybrid iterative reconstruction (HIR). Thirty-five patients with PDAC who underwent multiphasic CT were retrospectively evaluated. Raw data were reconstructed with two energy levels (40 keV and 70 keV) of virtual monochromatic imaging (VMI) using HIR (ASiR-V50%) and DLIR (TrueFidelity-H). Contrast-to-noise ratio (CNRtumor) was calculated from the CT values within regions of interest in tumor and normal pancreas in the pancreatic parenchymal phase images. Lesion conspicuity of PDAC in pancreatic parenchymal phase on 40-keV HIR, 40-keV DLIR, and 70-keV DLIR images was qualitatively rated on a 5-point scale, using 70-keV HIR images as reference (score 1 = poor; score 3 = equivalent to reference; score 5 = excellent) by two radiologists. CNRtumor of 40-keV DLIR images (median 10.4, interquartile range (IQR) 7.8-14.9) was significantly higher than that of the other VMIs (40 keV HIR, median 6.2, IQR 4.4-8.5, P < 0.0001; 70-keV DLIR, median 6.3, IQR 5.1-9.9, P = 0.0002; 70-keV HIR, median 4.2, IQR 3.1-6.1, P < 0.0001). CNRtumor of 40-keV DLIR images were significantly better than those of the 40-keV HIR and 70-keV HIR images by 72 ± 22% and 211 ± 340%, respectively. Lesion conspicuity scores on 40-keV DLIR images (observer 1, 4.5 ± 0.7; observer 2, 3.4 ± 0.5) were significantly higher than on 40-keV HIR (observer 1, 3.3 ± 0.9, P < 0.0001; observer 2, 3.1 ± 0.4, P = 0.013). DLIR is a promising reconstruction method to improve PDAC delineation in 40-keV VMI at the pancreatic parenchymal phase compared to conventional HIR.

18.
BMC Med Imaging ; 13: 27, 2013 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-23927627

RESUMO

BACKGROUND: The recently developed model-based iterative reconstruction (MBIR) enables significant reduction of image noise and artifacts, compared with adaptive statistical iterative reconstruction (ASIR) and filtered back projection (FBP). The purpose of this study was to evaluate lesion detectability of low-dose chest computed tomography (CT) with MBIR in comparison with ASIR and FBP. METHODS: Chest CT was acquired with 64-slice CT (Discovery CT750HD) with standard-dose (5.7 ± 2.3 mSv) and low-dose (1.6 ± 0.8 mSv) conditions in 55 patients (aged 72 ± 7 years) who were suspected of lung disease on chest radiograms. Low-dose CT images were reconstructed with MBIR, ASIR 50% and FBP, and standard-dose CT images were reconstructed with FBP, using a reconstructed slice thickness of 0.625 mm. Two observers evaluated the image quality of abnormal lung and mediastinal structures on a 5-point scale (Score 5 = excellent and score 1 = non-diagnostic). The objective image noise was also measured as the standard deviation of CT intensity in the descending aorta. RESULTS: The image quality score of enlarged mediastinal lymph nodes on low-dose MBIR CT (4.7 ± 0.5) was significantly improved in comparison with low-dose FBP and ASIR CT (3.0 ± 0.5, p = 0.004; 4.0 ± 0.5, p = 0.02, respectively), and was nearly identical to the score of standard-dose FBP image (4.8 ± 0.4, p = 0.66). Concerning decreased lung attenuation (bulla, emphysema, or cyst), the image quality score on low-dose MBIR CT (4.9 ± 0.2) was slightly better compared to low-dose FBP and ASIR CT (4.5 ± 0.6, p = 0.01; 4.6 ± 0.5, p = 0.01, respectively). There were no significant differences in image quality scores of visualization of consolidation or mass, ground-glass attenuation, or reticular opacity among low- and standard-dose CT series. Image noise with low-dose MBIR CT (11.6 ± 1.0 Hounsfield units (HU)) were significantly lower than with low-dose ASIR (21.1 ± 2.6 HU, p < 0.0005), low-dose FBP CT (30.9 ± 3.9 HU, p < 0.0005), and standard-dose FBP CT (16.6 ± 2.3 HU, p < 0.0005). CONCLUSION: MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT without compromising image quality. With radiation dose reduction of >70%, MBIR can provide equivalent lesion detectability of standard-dose FBP CT.


Assuntos
Algoritmos , Pneumopatias/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Interpretação Estatística de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Ann Nucl Med ; 37(6): 360-370, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36947324

RESUMO

PURPOSE: To evaluate the prognostic value of the quantitative assessment of 99mTc-methylene diphosphonate (99mTc-MDP) bone SPECT/CT in castration-resistant prostate cancer (CRPC) patients with bone metastases. METHODS: A total of 103 patients who underwent 99mTc-MDP bone SPECT/CT imaging from the neck to the proximal femur were included. First, in 65 patients without bone metastases, the normal range of standardized uptake value (SUV) of non-pathological bone was evaluated to determine an SUV threshold to reliably exclude most normal osseous activity. Then, in 38 CRPC patients with bone metastases, lesion uptake volume (LUV), which is the extracted volume of bone metastases exhibiting high accumulation above the SUV threshold, was calculated. The relation between LUV and prostate-related mortality was statistically evaluated. RESULTS: Based on the SUV measurements of non-pathological bones, the optimal SUV threshold, which defines abnormal bone SPECT uptake, was determined to be 8. Median LUV was 39 mL (interquartile range 4.0-104.3 mL) in the CRPC subjects with bone metastases. Kaplan-Meier survival analysis showed a significant relation between prostate cancer-specific survival and LUV (cut-off value, 19.95 mL; P = 0.001). Multivariate analysis revealed LUV as an independent prognostic factor for the survival (P = 0.008, hazard ratio 23.424). Global chi-square test showed that LUV had significant incremental prognostic value in addition to prostate-specific antigen and the interval from progression to CRPC until bone SPECT/CT (P = 0.022). CONCLUSION: Quantitative assessment of 99mTc-MDP bone SPECT images can provide valuable prognostic information in CRPC patients with bone metastases.


Assuntos
Neoplasias Ósseas , Neoplasias de Próstata Resistentes à Castração , Masculino , Humanos , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Estudos Retrospectivos , Prognóstico , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Castração , Medronato de Tecnécio Tc 99m
20.
Radiol Case Rep ; 18(9): 3212-3217, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37448598

RESUMO

Mixed epithelial and stromal tumor (MEST) of the kidney is a rare benign tumor with malignant potential, and is characterized by epithelial and stromal proliferation with a variety of cellularity and growth pattern. MEST of the kidney is often depicted as a well-defined, solid mass with a cystic component. However, due to the rarity of the disease, there are no reports of its progression in serial imaging examinations. This report presents the case of a 68-year-old woman with MEST who was followed for 13 years by computed tomography (CT). To the best of our knowledge, this is the first report of image findings of MEST of the kidney over a follow-up period longer than 10 years.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA