Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Artif Organs ; 20(1): 91-98, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27485094

RESUMO

Repair of large segmental defects of long bones are a tremendous challenge that calls for a novel approach to supporting immediate weight bearing and bone regeneration. This study investigated the functional and biological characteristics of a combination of a tailor-made titanium mesh cage with a plate (tTMCP) with tetrapod-shaped alpha tricalcium phosphate granules (TB) and basic fibroblast growth factor (bFGF)-binding ion complex gel (f-IC gel) to repair 20-mm segmental radial defects in dogs. The defects were created surgically in 18 adult beagle dogs and treated by implantation of tTMCPs with TB with (TB-gel group) or without (TB group) f-IC gel. Each tTMCP fitted the defect well, and all dogs could bear weight on the affected limb immediately after surgery. Dogs were euthanized 4, 8 and 24 weeks after implantation. Histomorphometry showed greater infiltration of new vessels and higher bone union rate in the TB-gel group than in the TB group. The lamellar bone volume and mineral apposition rate did not differ significantly between the groups, indicating that neovascularization may be the primary effect of f-IC gel on bone regeneration. This combination method which is tTMCP combined with TB and f-IC gel, would be useful for the treatment of segmental long bone defects.


Assuntos
Placas Ósseas , Regeneração Óssea/fisiologia , Rádio (Anatomia)/cirurgia , Titânio , Cicatrização/fisiologia , Animais , Regeneração Óssea/efeitos dos fármacos , Fosfatos de Cálcio/uso terapêutico , Cães , Fator 2 de Crescimento de Fibroblastos/uso terapêutico , Suporte de Carga , Cicatrização/efeitos dos fármacos
2.
Rev Sci Instrum ; 87(11): 11D617, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910509

RESUMO

High time resolved electron temperature measurements are useful for fluctuation study. A multi-pass Thomson scattering (MPTS) system is proposed for the improvement of both increasing the TS signal intensity and time resolution. The MPTS system in GAMMA 10/PDX has been constructed for enhancing the Thomson scattered signals for the improvement of measurement accuracy. The MPTS system has a polarization-based configuration with an image relaying system. We optimized the image relaying optics for improving the multi-pass laser confinement and obtaining the stable MPTS signals over ten passing TS signals. The integrated MPTS signals increased about five times larger than that in the single pass system. Finally, time dependent electron temperatures were obtained in MHz sampling.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA