Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 50(2): 581-592, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36192469

RESUMO

BACKGROUND: There is currently no established imaging method for assessing liver reserve capacity prior to carbon-ion radiotherapy (CIRT) for liver tumors. In order to perform safe CIRT, it is essential to estimate the post-therapeutic residual reserve capacity of the liver. PURPOSE: To evaluate the ability of pre-treatment 99mTc-galactosyl human serum albumin (99mTc-GSA) scintigraphy to accurately estimate the residual liver reserve capacity in patients treated with CIRT for liver tumors. MATERIALS AND METHODS: This retrospective study evaluated patients who were performed CIRT for liver tumors between December 2018 and September 2020 and underwent 99mTc-GSA scintigraphy before and 3 months after CIRT, and gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI within 1 month before CIRT were evaluated. The maximal removal rate of 99mTc-GSA (GSA-Rmax) was analyzed for the evaluation of pre-treatment liver reserve capacity. Then, the GSA-Rmax of the estimated residual liver (GSA-RL) was calculated using liver SPECT images fused with the Gd-EOB-DTPA-enhanced MRI. GSA-RL before CIRT and GSA-Rmax at 3 months after CIRT were compared using non-parametric Wilcoxon signed-rank test and linear regression analysis. RESULTS: Overall, 50 patients were included (mean age ± standard deviation, 73 years ± 11; range, 29-89 years, 35 men). The median GSA-RL was 0.393 [range, 0.057-0.729] mg/min, and the median GSA-Rmax after CIRT was 0.369 [range, 0.037-0.780] mg/min (P = .40). The linear regression equation representing the relationship between the GSA-RL and GSA-Rmax after CIRT was y = 0.05 + 0.84x (R2 = 0.67, P < .0001). There was a linear relationship between the estimated and actual post-treatment values for all patients, as well as in the group with impaired liver reserve capacity (y = - 0.02 + 1.09x (R2 = 0.62, P = .0005)). CONCLUSIONS: 99mTc-GSA scintigraphy has potential clinical utility for estimating the residual liver reserve capacity in patients undergoing carbon-ion radiotherapy for liver tumors. TRIAL REGISTRATION: UMIN000038328, https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000043545 .


Assuntos
Hepatectomia , Neoplasias Hepáticas , Humanos , Masculino , Carbono , Hepatectomia/métodos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/patologia , Cintilografia , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Pentetato de Tecnécio Tc 99m , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
2.
Eur J Nucl Med Mol Imaging ; 45(8): 1405-1416, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29478082

RESUMO

PURPOSE: The aim of this multicenter trial was to generate a [123I]FP-CIT SPECT database of healthy controls from the common SPECT systems available in Japan. METHODS: This study included 510 sets of SPECT data from 256 healthy controls (116 men and 140 women; age range, 30-83 years) acquired from eight different centers. Images were reconstructed without attenuation or scatter correction (NOACNOSC), with only attenuation correction using the Chang method (ChangACNOSC) or X-ray CT (CTACNOSC), and with both scatter and attenuation correction using the Chang method (ChangACSC) or X-ray CT (CTACSC). These SPECT images were analyzed using the Southampton method. The outcome measure was the specific binding ratio (SBR) in the striatum. These striatal SBRs were calibrated from prior experiments using a striatal phantom. RESULTS: The original SBRs gradually decreased in the order of ChangACSC, CTACSC, ChangACNOSC, CTACNOSC, and NOACNOSC. The SBRs for NOACNOSC were 46% lower than those for ChangACSC. In contrast, the calibrated SBRs were almost equal under no scatter correction (NOSC) conditions. A significant effect of age was found, with an SBR decline rate of 6.3% per decade. In the 30-39 age group, SBRs were 12.2% higher in women than in men, but this increase declined with age and was absent in the 70-79 age group. CONCLUSIONS: This study provided a large-scale quantitative database of [123I]FP-CIT SPECT scans from different scanners in healthy controls across a wide age range and with balanced sex representation. The phantom calibration effectively harmonizes SPECT data from different SPECT systems under NOSC conditions. The data collected in this study may serve as a reference database.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Tropanos , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Bases de Dados Factuais , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
3.
Eur J Nucl Med Mol Imaging ; 44(3): 366-372, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27544223

RESUMO

PURPOSE: For the quantitative assessment of dopamine transporter (DAT) using [123I]FP-CIT single-photon emission computed tomography (SPECT) (DaTscan), anatomic standardization is preferable for achieving objective and user-independent quantification of striatal binding using a volume-of-interest (VOI) template. However, low accumulation of DAT in Parkinson's disease (PD) would lead to a deformation error when using a DaTscan-specific template without any structural information. To avoid this deformation error, we applied computed tomography (CT) data obtained using SPECT/CT equipment to anatomic standardization. METHODS: We retrospectively analyzed DaTscan images of 130 patients with parkinsonian syndromes (PS), including 80 PD and 50 non-PD patients. First we segmented gray matter from CT images using statistical parametric mapping 12 (SPM12). These gray-matter images were then anatomically standardized using the diffeomorphic anatomical registration using exponentiated Lie algebra (DARTEL) algorithm. Next, DaTscan images were warped with the same parameters used in the CT anatomic standardization. The target striatal VOIs for decreased DAT in PD were generated from the SPM12 group comparison of 20 DaTscan images from each group. We applied these VOIs to DaTscan images of the remaining patients in both groups and calculated the specific binding ratios (SBRs) using nonspecific counts in a reference area. In terms of the differential diagnosis of PD and non-PD groups using SBR, we compared the present method with two other methods, DaTQUANT and DaTView, which have already been released as software programs for the quantitative assessment of DaTscan images. RESULTS: The SPM12 group comparison showed a significant DAT decrease in PD patients in the bilateral whole striatum. Of the three methods assessed, the present CT-guided method showed the greatest power for discriminating PD and non-PD groups, as it completely separated the two groups. CONCLUSION: CT-guided anatomic standardization using the DARTEL algorithm is promising for the quantitative assessment of DaTscan images.


Assuntos
Doença de Parkinson/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas , Tropanos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Estudos de Casos e Controles , Corpo Estriado/diagnóstico por imagem , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/patologia , Padrões de Referência , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
NMR Biomed ; 29(7): 890-5, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27129076

RESUMO

We examined and compared the temperatures of the intraventricular cerebrospinal fluid (Tv ) and the brain parenchyma (Tp ) using MRI, with reference to the tympanic membrane temperature (Tt ) in healthy subjects. We estimated Tv and Tp values from data gathered simultaneously by MR diffusion-weighted imaging (DWI) and MRS, respectively, in 35 healthy volunteers (17 males, 18 females; age 25-78 years). We also obtained Tt values just before each MR examination to evaluate the relationships among the three temperatures. There were significant positive correlations between Tv and Tp (R = 0.611, p < 0.001). The correlation was also significant after correction for Tt (R = 0.642, p < 0.001). There was no significant correlation between Tv and Tt or between Tp and Tt in the men or the women. Negative correlations were found between Tv and age and between Tp and age in the males but not females. DWI thermometry seems to reflect the intracranial environment as accurately as MRS thermometry. An age-dependent decline in temperature was evident in our male subjects by both DWI and MRS thermometry, probably due to the decrease in cerebral metabolism with age. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Temperatura Corporal/fisiologia , Ventrículos Cerebrais/fisiologia , Líquido Cefalorraquidiano/fisiologia , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Espectroscopia de Ressonância Magnética/métodos , Termografia/métodos , Adulto , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores Sexuais , Temperatura
5.
Epilepsy Behav ; 62: 239-45, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27497065

RESUMO

Graph theory is an emerging method to investigate brain networks. Altered cerebral blood flow (CBF) has frequently been reported in temporal lobe epilepsy (TLE), but graph theoretical findings of CBF are poorly understood. Here, we explored graph theoretical networks of CBF in TLE using arterial spin labeling imaging. We recruited patients with TLE and unilateral hippocampal sclerosis (HS) (19 patients with left TLE, and 21 with right TLE) and 20 gender- and age-matched healthy control subjects. We obtained all participants' CBF maps using pseudo-continuous arterial spin labeling and analyzed them using the Graph Analysis Toolbox (GAT) software program. As a result, compared to the controls, the patients with left TLE showed a significantly low clustering coefficient (p=0.024), local efficiency (p=0.001), global efficiency (p=0.010), and high transitivity (p=0.015), whereas the patients with right TLE showed significantly high assortativity (p=0.046) and transitivity (p=0.011). The group with right TLE also had high characteristic path length values (p=0.085), low global efficiency (p=0.078), and low resilience to targeted attack (p=0.101) at a trend level. Lower normalized clustering coefficient (p=0.081) in the left TLE and higher normalized characteristic path length (p=0.089) in the right TLE were found also at a trend level. Both the patients with left and right TLE showed significantly decreased clustering in similar areas, i.e., the cingulate gyri, precuneus, and occipital lobe. Our findings revealed differing left-right network metrics in which an inefficient CBF network in left TLE and vulnerability to irritation in right TLE are suggested. The left-right common finding of regional decreased clustering might reflect impaired default-mode networks in TLE.


Assuntos
Circulação Cerebrovascular/fisiologia , Epilepsia do Lobo Temporal/fisiopatologia , Hipocampo/patologia , Lobo Temporal/patologia , Adulto , Mapeamento Encefálico/métodos , Epilepsia do Lobo Temporal/patologia , Feminino , Hipocampo/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose/patologia , Esclerose/fisiopatologia , Software , Lobo Temporal/fisiopatologia
6.
Int J Geriatr Psychiatry ; 29(10): 1079-86, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24687634

RESUMO

OBJECTIVES: The purpose of this study was to clarify the concordance of diagnostic abilities and interobserver agreement between 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and brain perfusion single photon-emission computed tomography (SPECT) in patients with Alzheimer's disease (AD) who were diagnosed according to the research criteria of the National Institute of Aging-Alzheimer's Association Workshop. METHODS: Fifty-five patients with "AD and mild cognitive impairment (MCI)" (n = 40) and "non-AD" (n = 15) were evaluated with 18F-FDG PET and (99m)Tc-ethyl cysteinate dimer (ECD) SPECT during an 8-week period. Three radiologists independently graded the regional uptake in the frontal, temporal, parietal, and occipital lobes as well as the precuneus/posterior cingulate cortex in both images. Kappa values were used to determine the interobserver reliability regarding regional uptake. RESULTS: The regions with better interobserver reliability between 18F-FDG PET and (99m)Tc-ECD SPECT were the frontal, parietal, and temporal lobes. The (99m)Tc-ECD SPECT agreement in the occipital lobes was not significant. The frontal, temporal, and parietal lobes showed good correlations between 18F-FDG PET and (99m)Tc-ECD SPECT in the degree of uptake, but the occipital lobe and precuneus/posterior cingulate cortex did not show good correlations. The diagnostic accuracy rates of "AD and MCI" ranged from 60% to 70% in both of the techniques. CONCLUSIONS: The degree of uptake on 18F-FDG PET and (99m)Tc-ECD SPECT showed significant correlations in the frontal, temporal, and parietal lobes. The diagnostic abilities of 18F-FDG PET and (99m)Tc-ECD SPECT for "AD and MCI," when diagnosed according to the National Institute of Aging-Alzheimer's Association Workshop criteria, were nearly identical.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Transtornos Cognitivos/diagnóstico por imagem , Cisteína/análogos & derivados , Fluordesoxiglucose F18 , Compostos de Organotecnécio , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/metabolismo , Encéfalo/metabolismo , Transtornos Cognitivos/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tomografia por Emissão de Pósitrons/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/normas
7.
Neuroradiology ; 55(5): 559-66, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23322456

RESUMO

INTRODUCTION: The purpose of this study was to identify brain atrophy specific for dementia with Lewy bodies (DLB) and to evaluate the discriminatory performance of this specific atrophy between DLB and Alzheimer's disease (AD). METHODS: We retrospectively reviewed 60 DLB and 30 AD patients who had undergone 3D T1-weighted MRI. We randomly divided the DLB patients into two equal groups (A and B). First, we obtained a target volume of interest (VOI) for DLB-specific atrophy using correlation analysis of the percentage rate of significant whole white matter (WM) atrophy calculated using the Voxel-based Specific Regional Analysis System for Alzheimer's Disease (VSRAD) based on statistical parametric mapping 8 (SPM8) plus diffeomorphic anatomic registration through exponentiated Lie algebra, with segmented WM images in group A. We then evaluated the usefulness of this target VOI for discriminating the remaining 30 DLB patients in group B from the 30 AD patients. Z score values in this target VOI obtained from VSRAD were used as the determinant in receiver operating characteristic (ROC) analysis. RESULTS: Specific target VOIs for DLB were determined in the right-side dominant dorsal midbrain, right-side dominant dorsal pons, and bilateral cerebellum. ROC analysis revealed that the target VOI limited to the midbrain exhibited the highest area under the ROC curves of 0.75. CONCLUSIONS: DLB patients showed specific atrophy in the midbrain, pons, and cerebellum. Midbrain atrophy demonstrated the highest power for discriminating DLB and AD. This approach may be useful for determining the contributions of DLB and AD pathologies to the dementia syndrome.


Assuntos
Doença de Alzheimer/patologia , Encéfalo/patologia , Imagem de Tensor de Difusão/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Doença por Corpos de Lewy/patologia , Técnica de Subtração , Idoso , Algoritmos , Interpretação Estatística de Dados , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Int J Clin Oncol ; 17(3): 276-82, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21830087

RESUMO

BACKGROUND: To assess the usefulness of positron emission tomography combined with computed tomography using (18)F-fluorodeoxyglucose (FDG PET/CT) for optimizing chemotherapy during neoadjuvant chemotherapy for primary breast cancer. METHODS: One hundred and eight patients (110 tumors) with breast cancer (≥2 cm, stages II and III) received neoadjuvant chemotherapy consisting of an anthracycline-based regimen and taxane. The maximal value of the baseline standardized uptake value (SUV) and the change in SUV after four cycles of an anthracycline-based regimen relative to baseline SUV were assessed for predicting pathological complete response (pCR) after sequential taxane. RESULTS: Tumors with pCR had significantly higher baseline SUV (9.3 ± 3.7 SD) compared to those with non-pCR (7.2 ± 3.8 SD) (p = 0.02), but there was a considerable overlap between two groups. On PET scan after four cycles of chemotherapy, thirty-three patients (33.7%) with a 72.1% or greater reduction in SUV were considered as responders and the performance in predicting pCR had a sensitivity of 88.9% and specificity of 78.7%. CONCLUSION: The baseline SUV could not be a useful indicator for predicting pCR due to the wide range in sensitivity. On the other hand, a relative change in SUV after completion of an anthracycline-based regimen could be useful for predicting pCR.


Assuntos
Antineoplásicos/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Hidrocarbonetos Aromáticos com Pontes/uso terapêutico , Fluordesoxiglucose F18 , Compostos Radiofarmacêuticos , Taxoides/uso terapêutico , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Tomografia Computadorizada por Raios X
10.
Clin Nucl Med ; 47(12): 1066-1068, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36179331

RESUMO

ABSTRACT: The Alzheimer disease (AD) brain is characterized microscopically by the presence of extracellular amyloid plaques and intraneuronal neurofibrillary tangles consisting of phosphorylated tau aggregations. 18 F-THK5351 is a first-generation PET tau tracer that also binds to monoamine oxidase B, which represents astrogliosis, and is useful to evaluate some non-AD neurodegenerative disorders. We examined the utility of 18 F-THK5351 in preclinical AD using 3-dimensional stereotactic surface projection images optimized for its pathological accumulation by comparison with a normal dataset. By using this 18 F-THK5351 3-dimensional stereotactic surface projection procedure, which can evaluate phosphorylated tau and neuroinflammation, we could diagnose preclinical AD effectively.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Gliose/diagnóstico por imagem , Gliose/metabolismo , Proteínas tau/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo
11.
Ann Nucl Med ; 36(10): 865-875, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35821311

RESUMO

OBJECTIVE: Although beta-amyloid (Aß) positron emission tomography (PET) images are interpreted visually as positive or negative, approximately 10% are judged as equivocal in Alzheimer's disease. Therefore, we aimed to develop an automated semi-quantitative analysis technique using 18F-flutemetamol PET images without anatomical images. METHODS: Overall, 136 cases of patients administered 18F-flutemetamol were enrolled. Of 136 cases, five PET images each with the highest and lowest values of standardized uptake value ratio (SUVr) of cerebral cortex-to-pons were used to create positive and negative templates. Using these templates, PET images of the remaining 126 cases were standardized, and SUVr images were produced with the pons as a reference region. The mean of SUVr values in the volume of interest delineated on the cerebral cortex was compared to those in the CortexID Suite (GE Healthcare). Furthermore, centiloid (CL) values were calculated for the 126 cases using data from the Centiloid Project ( http://www.gaain.org/centiloid-project ) and both templates. 18F-flutemetamol-PET was interpreted visually as positive/negative based on Aß deposition in the cortex. However, the criterion "equivocal" was added for cases with focal or mild Aß accumulation that were difficult to categorize. Optimal cutoff values of SUVr and CL maximizing sensitivity and specificity for Aß detection were determined by receiver operating characteristic (ROC) analysis using the visual evaluation as a standard of truth. RESULTS: SUVr calculated by our method and CortexID were highly correlated (R2 = 0.9657). The 126 PET images comprised 84 negative and 42 positive cases of Aß deposition by visual evaluation, of which 11 and 10 were classified as equivocal, respectively. ROC analyses determined the optimal cutoff values, sensitivity, and specificity for SUVr as 0.544, 89.3%, and 92.9%, respectively, and for CL as 12.400, 94.0%, and 92.9%, respectively. Both semi-quantitative analyses showed that 12 and 9 of the 21 equivocal cases were negative and positive, respectively, under the optimal cutoff values. CONCLUSIONS: This semi-quantitative analysis technique using 18F-flutemetamol-PET calculated SUVr and CL automatically without anatomical images. Moreover, it objectively and homogeneously interpreted positive or negative Aß burden in the brain as a supplemental tool for the visual reading of equivocal cases in routine clinical practice.


Assuntos
Doença de Alzheimer , Amiloidose , Doença de Alzheimer/diagnóstico por imagem , Amiloide/metabolismo , Peptídeos beta-Amiloides/metabolismo , Compostos de Anilina , Benzotiazóis , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Humanos , Tomografia por Emissão de Pósitrons/métodos
12.
Front Aging Neurosci ; 14: 847094, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35517046

RESUMO

Neurodegenerative changes in the preclinical stage of Alzheimer's disease (AD) have recently been the focus of attention because they may present a range of treatment opportunities. A total of 134 elderly volunteers who lived in a local community were investigated and grouped into preclinical and mild cognitive impairment stages according to the Clinical Dementia Rating test; we also estimated amyloid deposition in the brain using positron emission tomography (PET). A significant interaction between clinical stage and amyloid PET positivity on cerebral atrophy was observed in the bilateral parietal lobe, parahippocampal gyri, hippocampus, fusiform gyrus, and right superior and middle temporal gyri, as previously reported. Early AD-specific voxel of interest (VOI) analysis was also applied and averaged Z-scores in the right, left, bilateral, and right minus left medial temporal early AD specific area were computed. We defined these averaged Z-scores in the right, left, bilateral, and right minus left early AD specific VOI in medial temporal area as R-MedT-Atrophy-score, L-MedT-Atrophy-score, Bil-MedT-Atrophy-score, and R_L-MedT-Atrophy-score, respectively. It revealed that the R_L-MedT-Atrophy-scores were significantly larger in the amyloid-positive than in the amyloid-negative cognitively normal (CN) elderly group, that is, the right medial temporal areas were smaller than left in amyloid positive CN group and these left-right differences were significantly larger in amyloid positive than amyloid negative CN elderly group. The L-MedT-Atrophy-score was slightly larger (p = 0.073), that is, the left medial temporal area was smaller in the amyloid-negative CN group than in the amyloid-positive CN group. Conclusively, the left medial temporal area could be larger in CN participants with amyloid deposition than in those without amyloid deposition. The area under the receiver operating characteristic curve for differentiating amyloid positivity among CN participants using the R_L-MedT-Atrophy-scores was 0.73; the sensitivity and specificity were 0.828 and 0.606, respectively. Although not significant, a negative correlation was observed between the composite cerebral standardized uptake value ratio in amyloid PET images and L-MedT-Atrophy-score in CN group. The left medial temporal volume might become enlarged because of compensatory effects against AD pathology occurring at the beginning of the amyloid deposition.

13.
Med Phys ; 49(5): 2995-3005, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35246870

RESUMO

PURPOSE: The Bayesian penalized likelihood (BPL) reconstruction algorithm, Q.Clear, can achieve a higher signal-to-noise ratio on images and more accurate quantitation than ordered subset-expectation maximization (OSEM). The reconstruction parameter (ß) in BPL requires optimization according to the radiopharmaceutical tracer. The present study aimed to define the optimal ß value in BPL required to diagnose Alzheimer disease from brain positron emission tomography (PET) images acquired using 18 F-fluoro-2-deoxy-D-glucose ([18 F]FDG) and 11 C-labeled Pittsburg compound B ([11 C]PiB). METHODS: Images generated from Hoffman 3D brain and cylindrical phantoms were acquired using a Discovery PET/computed tomography (CT) 710 and reconstructed using OSEM + time-of-flight (TOF) under clinical conditions and BPL + TOF (ß = 20-1000). Contrast was calculated from images generated by the Hoffman 3D brain phantom, and noise and uniformity were calculated from those generated by the cylindrical phantom. Five cognitively healthy controls and five patients with Alzheimer disease were assessed using [18 F]FDG and [11 C]PiB PET to validate the findings from the phantom study. The ß values were restricted by the findings of the phantom study, then one certified nuclear medicine physician and two certified nuclear medicine technologists visually determined optimal ß values by scoring the quality parameters of image contrast, image noise, cerebellar stability, and overall image quality of PET images from 1 (poor) to 5 (excellent). RESULTS: The contrast in BPL satisfied the Japanese Society of Nuclear Medicine (JSNM) criterion of ≥55% and exceeded that of OSEM at ranges of ß = 20-450 and 20-600 for [18 F]FDG and [11 C]PiB, respectively. The image noise in BPL satisfied the JSNM criterion of ≤15% and was below that in OSEM when ß = 150-1000 and 400-1000 for [18 F]FDG and [11 C]PiB, respectively. The phantom study restricted the ranges of ß values to 100-300 and 300-500 for [18 F]FDG and [11 C]PiB, respectively. The BPL scores for gray-white matter contrast and image noise, exceeded those of OSEM in [18 F]FDG and [11 C]PiB images regardless of ß values. Visual evaluation confirmed that the optimal ß values were 200 and 450 for [18 F]FDG and [11 C]PiB, respectively. CONCLUSIONS: The BPL achieved better image contrast and less image noise than OSEM, while maintaining quantitative standardized uptake value ratios (SUVR) due to full convergence, more rigorous noise control, and edge preservation. The optimal ß values for [18 F]FDG and [11 C]PiB brain PET were apparently 200 and 450, respectively. The present study provides useful information about how to determine optimal ß values in BPL for brain PET imaging.


Assuntos
Doença de Alzheimer , Compostos de Anilina/química , Fluordesoxiglucose F18 , Tiazóis/química , Algoritmos , Doença de Alzheimer/diagnóstico por imagem , Teorema de Bayes , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons
14.
Int J Clin Oncol ; 16(1): 39-44, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20862596

RESUMO

BACKGROUND: An important step in deciding the treatment strategy for pancreatic cancer is to preoperatively predict the possibility of early recurrence. We reviewed whether 18[F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) before pancreatic cancer resection could predict tumor recurrence in the early postoperative period. METHODS: FDG-PET/CT was performed preoperatively on 56 patients with pancreatic cancer. The maximum standardized uptake (SUV(max)) values obtained by FDG-PET/CT were compared between two groups: patients with and without recurrence within the first 6 postoperative months. SUV(max) analyses were also performed to determine whether age, sex, CA 19-9 values, the operative method, and portal vein resection were also predictive of recurrence within less than 6 months after tumor resection. RESULTS: The median SUV(max) values of the recurrence group and no-recurrence group were 7.9 and 4.2, respectively (P = 0.0042). The SUV(max) was the only risk factor for recurrence in the first 6 postoperative months identified by multivariate analysis (P = 0.0062). CONCLUSIONS: Preoperative SUV(max) was higher in the recurrence group during the early postoperative period, and a high SUV(max) was a risk factor for early postoperative recurrence. Based on these results, we conclude that FDG-PET/CT is predictive of the recurrence of pancreatic cancer in the early postoperative period.


Assuntos
Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/cirurgia , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Recidiva Local de Neoplasia/patologia , Neoplasias Pancreáticas/patologia , Período Pré-Operatório
15.
Clin Nucl Med ; 46(3): 243-245, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33323735

RESUMO

ABSTRACT: Amyotrophic lateral sclerosis (ALS) involves both upper motor neurons (UMNs) and lower motor neurons. The detection of UMN involvement, a core component of ALS criteria, is primarily dependent on neurological examination because of a lack of definitive biomarkers. We present the 18F-THK5351 PET images of a 76-year-old man diagnosed with ALS comorbid with Alzheimer disease, demonstrating marked accumulation of 18F-THK5351 in the bilateral precentral gyri. Because 18F-THK5351 binds to monoamine oxidase B highly expressed in astrocytes, where the neurodegenerative process is ongoing, our case highlights that 18F-THK5351 tracer should be a useful marker for detecting UMN neurodegeneration in ALS.


Assuntos
Aminopiridinas , Esclerose Lateral Amiotrófica/diagnóstico por imagem , Córtex Motor/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Quinolinas , Idoso , Doença de Alzheimer/complicações , Esclerose Lateral Amiotrófica/complicações , Humanos , Masculino
16.
Ann Nucl Med ; 35(11): 1240-1252, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34368924

RESUMO

OBJECTIVE: 5-(1-(2-[18F]fluoroethoxy))-[3-(6,7-dimethoxy-3,4-dihydro-1H-isoquinolin-2-yl)-propyl]-5,6,7,8-tetrahydronaphthalen ([18F]MC225) is a selective substrate for P-glycoprotein (P-gp), possessing suitable properties for measuring overexpression of P-gp in the brain. This is the first-in-human study to examine safety, radiation dosimetry and P-gp function at the blood-brain barrier (BBB) of [18F]MC225 in healthy subjects. METHODS: [18F]MC225 biodistribution and dosimetry were determined in 3 healthy male subjects, using serial 2 h and intermittent 4 and 6 h whole-body PET scans acquired after [18F]MC225 injection. Dynamic [18F]MC225 brain PET (90 min) was obtained in 5 healthy male subjects. Arterial blood was sampled at various time intervals during scanning and the fraction of unchanged [18F]MC225 in plasma was determined. T1-weighted MRI was performed for anatomical coregistration. Total distribution volume (VT) was estimated using 1- and 2-tissue-compartment models (1-TCM and 2-TCM, respectively). VT was also estimated using the Logan graphical method (Logan plot) (t* = 20 min). Surrogate parameters without blood sampling (area-under the curve [AUC] of regional time-activity curves [TACs] and negative slope of calculated TACs) were compared with the VT values. RESULTS: No serious adverse events occurred throughout the study period. Although biodistribution implied hepatobiliary excretion, secretion of radioactivity from liver to small intestine through the gallbladder was very slow. Total renal excreted radioactivity recovered during 6 h after injection was < 2%ID. Absorbed dose was the highest in the pancreas (mean ± SD, 203 ± 45 µGy/MBq) followed by the liver (83 ± 11 µGy/MBq). Mean effective dose with and without urination was 17 ± 1 µSv/MBq. [18F]MC225 readily entered the brain, distributing homogeneously in grey matter regions. 2-TCM provided lower Akaike information criterion scores than did 1-TCM. VT estimated by Logan plot was well correlated with that of 2-TCM (r2 > 0.9). AUCs of TACs were positively correlated with VT (2-TCM) values (r2: AUC0-60 min = 0.61, AUC0-30 min = 0.62, AUC30-60 min = 0.59, p < 0.0001). Negative slope of SUV TACs was negatively correlated with VT (2-TCM) values (r2 = 0.53, p < 0.0001). CONCLUSIONS: This initial evaluation indicated that [18F]MC225 is a suitable and safe PET tracer for measuring P-gp function at the BBB.


Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP
17.
Med Phys ; 37(12): 6178-86, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21302774

RESUMO

PURPOSE: Respiratory monitoring systems are used to detect the respiratory phase of patients during the planning and administration of respiratory gated radiotherapy by using four-dimensional computed tomography (4DCT) or 4D positron-emission tomography/CT (4DPET/CT) and the linear accelerator (linac), respectively. Generally, identical respiratory monitoring systems are used for 4DCT, 4DPET/CT, and linac. However, different systems are sometimes used in combination because the accessibility of the respiratory monitoring systems may differ by manufacturer. The combined use of different respiratory monitoring systems in phase-based gating is of concern because the differences in the timing of tags (end-respiration signals algorithmically determined by the respiratory monitoring system), defined by the two systems, may result in phase differences, The purpose of this study is to estimate this difference and evaluate its effect on 4DCT data. METHODS: Ten patients (seven men and three women) with a median age of 75 yr (range: 57-84 yr) were treated by gated stereotactic body radiation therapy between April and December 2009. Two types of respiratory monitoring systems--RPM (Varian Medical Systems) and AZ-733V (Anzai MEDICAL)--were placed on the abdominal surface of the patients, and the respiratory signals were acquired by both systems. The relationship between the amplitude peak and the tag obtained by each respiratory system was analyzed for each patient. Further, the 4DCT images were reconstructed by using the signals obtained from both the RPM and the AZ-733V systems, and the tumor volumes and the tumor centroid positions in the craniocaudal plane were analyzed for each patient. RESULTS: The correlation factor between the respiratory signals from the RPM system and AZ-733V system was 0.990 (range: 0.940-0.994). The amplitude peak of the RPM system corresponded well with that of the AZ-733V system. The median +/- standard deviation of the phase difference for all the patients ranged from -4.3 +/- 7.1% to 3.5 +/- 2.2%. In the case of some patients, differences were noted between the two systems in the estimation of the tumor centroid position and tumor shape. CONCLUSIONS: The estimation of the position of the tumor centroid and tumor shape may vary with the use of different respiratory monitoring systems. This implies that it is preferable to use the same respiratory monitoring system with 4DCT, 4DPET-CT, and linac.


Assuntos
Radioterapia/métodos , Respiração , Neoplasias Abdominais/diagnóstico , Neoplasias Abdominais/patologia , Neoplasias Abdominais/fisiopatologia , Neoplasias Abdominais/radioterapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/radioterapia , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos , Carga Tumoral/efeitos da radiação
18.
BMC Med Imaging ; 10: 17, 2010 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-20701753

RESUMO

BACKGROUND: Partial volume effects in atrophied areas should be taken into account when interpreting brain perfusion single photon emission computed tomography (SPECT) images of neurodegenerative diseases. To evaluate both perfusion and atrophy using brain SPECT alone, we developed a new technique applying tensor-based morphometry (TBM) to SPECT. METHODS: After linear spatial normalization of brain perfusion SPECT using 99mTc-ethyl cysteinate dimer (99mTc-ECD) to a Talairach space, high-dimension-warping was done using an original 99mTc-ECD template. Contraction map images calculated from Jacobian determinants and spatially normalized SPECT images using this high-dimension-warping were compared using statistical parametric mapping (SPM2) between two groups of 16 multiple system atrophy of the cerebellar type (MSA-C) patients and 73 age-matched normal controls. This comparison was also performed in conventionally warped SPECT images. RESULTS: SPM2 demonstrated statistically significant contraction indicating local atrophy and decreased perfusion in the whole cerebellum and pons of MSA-C patients as compared to normal controls. Higher significance for decreased perfusion in these areas was obtained in high-dimension-warping than in conventional warping, possibly due to sufficient spatial normalization to a 99mTc-ECD template in high-dimensional warping of severely atrophied cerebellum and pons. In the present high-dimension-warping, modification of tracer activity remained within 3% of the original tracer distribution. CONCLUSIONS: The present new technique applying TBM to brain SPECT provides information on both perfusion and atrophy at the same time thereby enhancing the role of brain perfusion SPECT.


Assuntos
Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Atrofia/diagnóstico por imagem , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Ann Nucl Med ; 23(3): 283-91, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19347569

RESUMO

OBJECTIVE: A multicenter prospective study was performed to assess the additional value of a subtraction ictal SPECT coregistered to MRI (SISCOM) technique to traditional side-by-side comparison of ictal- and interictal SPECT images in epilepsy surgery. METHODS: One hundred and twenty-three patients with temporal and extratemporal lobe epilepsy who had undergone epilepsy surgery after evaluation of scalp ictal and interictal electroencephalogram (EEG), MRI, and ictal and interictal SPECT scans were followed up in terms of postsurgical outcome for a period of at least 1 year. Three reviewers localized the epileptogenic focus using ictal and interictal SPECT images first by side-by-side comparison and subsequently by SISCOM. Concordance of the localization of the epileptogenic focus by SPECT diagnosis with the surgical site and inter-observer agreement between reviewers was compared between side-by-side comparison and SISCOM. Logistic regression analysis was performed in predicting the surgical outcome with the dependent variable being the achievement of a good postsurgical outcome and the independent variables using the SISCOM, side-by-side comparison of ictal and interictal SPECT images, MRI, and scalp ictal EEG. RESULTS: The SISCOM presented better concordance in extratemporal lobe epilepsy and less concordance in temporal lobe epilepsy than side-by-side comparison. Inter-observer concordance was higher in SISCOM than in side-by-side comparison. Much higher concordance of the epileptogenic focus by SPECT diagnosis with the surgical site was obtained in patients with good surgical outcome than in those with poor surgical outcome. These differences in concordance between good and poor surgical outcomes were greater in SISCOM than in side-by-side comparison. Logistic regression analysis showed the highest odds ratio of 12.391 (95% confidence interval; 3.319, 46.254) by SISCOM evaluation for concordance of the epileptogenic focus with the surgical site in predicting good surgical outcome. CONCLUSIONS: A SISCOM technique of ictal and interictal SPECT images provides higher predictive value of good surgical outcome and more reliability on the diagnosis of the epileptogenic focus than side-by-side comparison in medically intractable partial epilepsy.


Assuntos
Epilepsias Parciais/diagnóstico por imagem , Epilepsias Parciais/cirurgia , Técnica de Subtração , Adolescente , Adulto , Criança , Pré-Escolar , Epilepsias Parciais/terapia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento
20.
Nucl Med Commun ; 29(9): 770-4, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18677203

RESUMO

BACKGROUND AND AIM: Skeletal muscle blood flow (SMBF) is a crucial indicator of impaired peripheral circulation. Although 133Xe has long been used for estimation of regional SMBF, its lipophilic and volatile nature hampers precise measurement. Therefore, we established an improved method based on 99mTc-pertechnetate ion (99mTcO-4) clearance. METHODS: Ten healthy male volunteers including five rugby players and five non-athletes (each group aged 25-35 years) received injection of 99mTcO-4 into the bilateral tibialis anterior muscles and gastrocnemius muscles (GCMs). The radioactivity of 99mTcO-4 before, during, and after toe-up or treadmill exercise was traced using a gamma-camera. Regional SMBF in absolute values (in ml/min/100 g muscle) was then calculated based on the half-time obtained from the time-activity curve. RESULTS: In both the groups, SMBF in tibialis anterior muscle changed similarly with values at the same levels. In contrast, SMBF in GCM showed marked difference between the two groups: in rugby players, SMBF in GCM returned to the baseline level (6.5+/-1.7, n=10) immediately after treadmill exercise, whereas that in non-athletes remained high (16.2+/-3.2, n=10). CONCLUSION: Regional SMBF measured by 99mTcO-4 clearance can indicate effectiveness of exercise training, and would be a diagnostic tool and prognostic indicator for use in patients with impaired peripheral circulation.


Assuntos
Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/patologia , Compostos Radiofarmacêuticos/farmacocinética , Pertecnetato Tc 99m de Sódio/farmacocinética , Adulto , Exercício Físico , Câmaras gama , Raios gama , Humanos , Masculino , Prognóstico , Fluxo Sanguíneo Regional , Projetos de Pesquisa , Esportes , Fatores de Tempo , Doenças Vasculares/diagnóstico , Doenças Vasculares/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA