Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
JCO Glob Oncol ; 10: e2400173, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39236283

RESUMO

PURPOSE: Most research on artificial intelligence-based auto-contouring as template (AI-assisted contouring) for organs-at-risk (OARs) stem from high-income countries. The effect and safety are, however, likely to depend on local factors. This study aimed to investigate the effects of AI-assisted contouring and teaching on contouring time and contour quality among radiation oncologists (ROs) working in low- and middle-income countries (LMICs). MATERIALS AND METHODS: Ninety-seven ROs were randomly assigned to either manual or AI-assisted contouring of eight OARs for two head-and-neck cancer cases with an in-between teaching session on contouring guidelines. Thereby, the effect of teaching (yes/no) and AI-assisted contouring (yes/no) was quantified. Second, ROs completed short-term and long-term follow-up cases all using AI assistance. Contour quality was quantified with Dice Similarity Coefficient (DSC) between ROs' contours and expert consensus contours. Groups were compared using absolute differences in medians with 95% CIs. RESULTS: AI-assisted contouring without previous teaching increased absolute DSC for optic nerve (by 0.05 [0.01; 0.10]), oral cavity (0.10 [0.06; 0.13]), parotid (0.07 [0.05; 0.12]), spinal cord (0.04 [0.01; 0.06]), and mandible (0.02 [0.01; 0.03]). Contouring time decreased for brain stem (-1.41 [-2.44; -0.25]), mandible (-6.60 [-8.09; -3.35]), optic nerve (-0.19 [-0.47; -0.02]), parotid (-1.80 [-2.66; -0.32]), and thyroid (-1.03 [-2.18; -0.05]). Without AI-assisted contouring, teaching increased DSC for oral cavity (0.05 [0.01; 0.09]) and thyroid (0.04 [0.02; 0.07]), and contouring time increased for mandible (2.36 [-0.51; 5.14]), oral cavity (1.42 [-0.08; 4.14]), and thyroid (1.60 [-0.04; 2.22]). CONCLUSION: The study suggested that AI-assisted contouring is safe and beneficial to ROs working in LMICs. Prospective clinical trials on AI-assisted contouring should, however, be conducted upon clinical implementation to confirm the effects.


Assuntos
Inteligência Artificial , Humanos , Órgãos em Risco/efeitos da radiação , Neoplasias de Cabeça e Pescoço/radioterapia , Feminino , Masculino , Planejamento da Radioterapia Assistida por Computador/métodos , Radio-Oncologistas/educação , Adulto , Pessoa de Meia-Idade
2.
Radiat Oncol J ; 37(4): 254-258, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31918462

RESUMO

PURPOSE: Deep inspiration breath hold (DIBH) is a well-established technique that enables efficient cardiac sparing in patients with left-sided breast cancer. The aim of the current study was to determine if DIBH is effective for reducing radiation exposure of of liver and other organs at risk in right breast radiotherapy (RT). MATERIALS AND METHODS: Twenty patients with right-sided breast cancer were enrolled in this study. Three-dimensional conformal RT plans were generated for each patient, with two different computed tomography scans of free breathing (FB) and DIBH. Nodes were contoured according to the Radiation Therapy Oncology Group contouring guidelines. Dose-volume histograms for the target volume coverage and organs at risk were evaluated and analyzed. RESULTS: DIBH plans showed significant reduction in mean liver dose (5.59 ± 2.07 Gy vs. 2.54 ± 1.40 Gy; p = 0.0003), V20Gy (148.38 ± 73.05 vs. 64.19 ± 51.07 mL; p = 0.0003) and V10Gy (195.34 ± 93.57 vs. 89.81 ± 57.28 mL; p = 0.0003) volumes compared with FB plans. Right lung doses were also significantly reduced in DIBH plans. Heart and left lung doses showed small but statistically significant improvement with application of the DIBH technique. CONCLUSION: We report that the use of DIBH for right-sided breast cancer significantly reduces the radiation doses to the liver, lungs, and heart.

3.
Radiother Oncol ; 127(2): 171-177, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29705501

RESUMO

BACKGROUND: The quality of radiotherapy services in post-Soviet countries has not yet been studied following a formal methodology. The IAEA conducted a survey using two sets of validated radiation oncology quality indicators (ROIs). METHODS: Eleven post-Soviet countries were assessed. A coordinator was designated for each country and acted as the liaison between the country and the IAEA. The methodology was a one-time cross-sectional survey using a 58-question tool in Russian. The questionnaire was based on two validated sets of ROIs: for radiotherapy centres, the indicators proposed by Cionini et al., and for data at the country level, the Australasian ROIs. RESULTS: The overall response ratio was 66.3%, but for the Russian Federation, it was 24%. Data were updated on radiotherapy infrastructure and equipment. 256 radiotherapy centres are operating 275 linear accelerators and 337 Cobalt-60 units. 61% of teletherapy machines are older than ten years. Analysis of ROIs revealed significant differences between these countries and radiotherapy practices in the West. Naming, task profile and education programmes of radiotherapy professionals are different than in the West. CONCLUSIONS: Most countries need modernization of their radiotherapy infrastructure coupled with adequate staffing numbers and updated education programmes focusing on evidence-based medicine, quality, and safety.


Assuntos
Neoplasias/radioterapia , Qualidade da Assistência à Saúde , Radioisótopos de Cobalto/uso terapêutico , Estudos Transversais , Humanos , Neoplasias/epidemiologia , Aceleradores de Partículas/provisão & distribuição , Indicadores de Qualidade em Assistência à Saúde , Radioterapia (Especialidade)/normas , Radioterapia (Especialidade)/estatística & dados numéricos , Radioterapia/instrumentação , Radioterapia/normas , Inquéritos e Questionários , U.R.S.S./epidemiologia
4.
J Contemp Brachytherapy ; 9(2): 106-111, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28533797

RESUMO

PURPOSE: To describe early results of two cohorts of patients with low and intermediate risk of early breast cancer treated with accelerated partial breast irradiation (APBI) using different schedules of multicatheter brachytherapy. MATERIAL AND METHODS: Patients with early stage breast cancer after breast conserving surgery were enrolled for a prospective analysis. The APBI, using multicatheter brachytherapy, was delivered either eight times 4 Gy in five days with a planned total dose of 32 Gy, or seven times 5 Gy in four days with a planned total dose of 35 Gy. Primary endpoints were side effects. RESULTS: Forty-eight patients were enrolled between 2012 and 2014. Patients characteristics were as follow: median age of patients was 55 years, early breast cancer was defined according GEC-ESTRO recommendations. With a median follow-up period of 37 months, no significant differences regarding late side effects and cosmesis between two cohorts of patients were documented. In total, cosmesis was excellent in 13/48 (27.1%) patients, good in 34/48 (70.8%) patients, and moderate in 1/48 patient (2.1%). CONCLUSIONS: Accelerated partial breast irradiation using multicatheter brachytherapy with 32 Gy/8 fractions and 35 Gy/7 fractions for early breast cancer seems to be similar in terms of late side effects. According to our findings, APBI was also feasible for intermediate-risk of early breast cancer patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA