Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Med Educ ; 24(1): 250, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38500112

RESUMO

OBJECTIVE: The gold standard of oral cancer (OC) treatment is diagnostic confirmation by biopsy followed by surgical treatment. However, studies have shown that dentists have difficulty performing biopsies, dental students lack knowledge about OC, and surgeons do not always maintain a safe margin during tumor resection. To address this, biopsies and resections could be trained under realistic conditions outside the patient. The aim of this study was to develop and to validate a porcine pseudotumor model of the tongue. METHODS: An interdisciplinary team reflecting various specialties involved in the oncological treatment of head and neck oncology developed a porcine pseudotumor model of the tongue in which biopsies and resections can be practiced. The refined model was validated in a final trial of 10 participants who each resected four pseudotumors on a tongue, resulting in a total of 40 resected pseudotumors. The participants (7 residents and 3 specialists) had an experience in OC treatment ranging from 0.5 to 27 years. Resection margins (minimum and maximum) were assessed macroscopically and compared beside self-assessed margins and resection time between residents and specialists. Furthermore, the model was evaluated using Likert-type questions on haptic and radiological fidelity, its usefulness as a training model, as well as its imageability using CT and ultrasound. RESULTS: The model haptically resembles OC (3.0 ± 0.5; 4-point Likert scale), can be visualized with medical imaging and macroscopically evaluated immediately after resection providing feedback. Although, participants (3.2 ± 0.4) tended to agree that they had resected the pseudotumor with an ideal safety margin (10 mm), the mean minimum resection margin was insufficient at 4.2 ± 1.2 mm (mean ± SD), comparable to reported margins in literature. Simultaneously, a maximum resection margin of 18.4 ± 6.1 mm was measured, indicating partial over-resection. Although specialists were faster at resection (p < 0.001), this had no effect on margins (p = 0.114). Overall, the model was well received by the participants, and they could see it being implemented in training (3.7 ± 0.5). CONCLUSION: The model, which is cost-effective, cryopreservable, and provides a risk-free training environment, is ideal for training in OC biopsy and resection and could be incorporated into dental, medical, or oncologic surgery curricula. Future studies should evaluate the long-term training effects using this model and its potential impact on improving patient outcomes.


Assuntos
Margens de Excisão , Neoplasias Bucais , Animais , Humanos , Biópsia , Cadáver , Cabeça , Neoplasias Bucais/cirurgia , Neoplasias Bucais/patologia , Suínos
2.
Minim Invasive Ther Allied Technol ; 31(6): 902-908, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34865602

RESUMO

INTRODUCTION: The aim of the study was to demonstrate the feasibility of a prototype for accelerometer-based guidance for percutaneous CT-guided punctures and compare it with free-hand punctures. MATERIAL AND METHODS: The prototype enabled alignment with the CT coordinate system and a wireless connectivity. Its feasibility was tested in a swine cadaver model: 20 out-of-plane device-assisted punctures performed without intermittent control scans (one-step punctures) were evaluated regarding deviation to target and difference between planned and obtained angle. Thereafter, 22 device-assisted punctures were compared with 20 free-hand punctures regarding distance to target, deviation from the planned angle, number of control scans and procedure time. Differences were compared with the Mann-Whitney U-test (p < .05). RESULTS: The one-step punctures revealed a deviation to target of 0.26 ± 0.37 cm (axial plane) and 0.21 ± 0.19 cm (sagittal plane) and differences between planned and performed puncture angles of 0.9 ± 1.09° (axial plane) and 1.15 ± 0.91° (sagittal planes). In the comparative study, device-assisted punctures showed a significantly higher accuracy, 0.20 ± 0.17 cm vs. 0.30 ± 0.21 cm (p < .05) and lower number of required control scans, 1.3 ± 1.1 vs. 3.7 ± 0.9 (p < .05) compared with free-hand punctures. CONCLUSION: The accelerometer-based device proved to be feasible and demonstrated significantly higher accuracy and required significantly less control scans compared to free-hand puncture.


Assuntos
Punções , Tomografia Computadorizada por Raios X , Acelerometria , Animais , Agulhas , Suínos , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 31(5): 3035-3041, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33051733

RESUMO

OBJECTIVES: The aim of this study was to compare success, technical complexity, and complication rates of percutaneous transhepatic biliary drainage (PTBD) in patients with dilated vs. nondilated bile ducts. METHODS: In a retrospective analysis, we evaluated all consecutive PTBD performed in our department over a period of 5 years. Technical success, technical data (side, fluoroscopy time, radiation dose, amount of contrast media, use of disposable equipment), procedure-related complications and peri-interventional mortality were compared for patients with dilated vs. non-dilated bile ducts. Independent t test and χ2 test were used to evaluate the statistical significance. RESULTS: A total of 253 procedures were performed on 187 patients, of whom 101/253 had dilated bile ducts and 152/253 not. In total, 243/253 procedures were successful. PTBD was significantly more often successful in patients with dilated vs. nondilated bile ducts (150/153 vs. 93/101; p 0.02). Overall complication rate (13%) did not differ significantly between patients with dilated vs. nondilated bile ducts. Procedures in patients with normal, nondilated bile ducts were associated with a significantly higher rate of post-interventional bleeding (5/101 vs. 0/152). Mean fluoroscopy time (42:36 ± 35:39 h vs. 30:28 ± 25:10 h; p 0.002) and amount of contrast media (66 ± 40 ml vs. 52 ± 24 ml; p 0.07) or use of disposables were significantly higher in patients with nondilated ducts. A significantly lower fluoroscopy time and amount of contrast medium were used in left hepatic PTBD. CONCLUSION: Despite the higher technical complexity, PTBD with nondilated bile ducts was associated with similar overall complication rates but higher bleeding complications compared with PTBD with dilated bile ducts. KEY POINTS: • PTBD was associated with similar overall complication rates in patients with dilated vs. nondilated bile ducts. • Although overall complication rates were low, PTBD in patients with nondilated bile ducts was associated with a higher incidence of post-interventional bleeding. • PTBD in patients with nondilated bile ducts is technically more complex.


Assuntos
Ductos Biliares , Drenagem , Ductos Biliares/diagnóstico por imagem , Dilatação Patológica , Fluoroscopia , Humanos , Estudos Retrospectivos
4.
J Vasc Interv Radiol ; 32(6): 836-842.e2, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33689835

RESUMO

PURPOSE: To compare hepatic hypertrophy in the contralateral lobe achieved by unilobar transarterial radioembolization (TARE) versus portal vein embolization (PVE) in a swine model. METHODS: After an escalation study to determine the optimum dose to achieve hypertrophy after unilobar TARE in 4 animals, 16 pigs were treated by TARE (yttrium-90 resin microspheres) or PVE (lipiodol/n-butyl cyanoacrylate). Liver volume was calculated based on CT before treatment and during 6 months of follow-up. Independent t-test (P < .05) was used to compare hypertrophy. The relationship between hypertrophy after TARE and absorbed dose was calculated using the Pearson correlation. RESULTS: At 2 and 4 weeks after treatment, a significantly higher degree of future liver remnant hypertrophy was observed in the PVE group versus the TARE group, with a median volume gain of 31% (interquartile range [IQR]: 16%-66%) for PVE versus 23% (IQR: 6%-36%) for TARE after 2 weeks and 51% (IQR: 47%-69%) for PVE versus 29% (IQR: 20%-50%) for TARE after 4 weeks. After 3 and 6 months, hypertrophy converged without a statistically significant difference, with a volume gain of 103% (IQR: 86%-119%) for PVE versus 82% (IQR: 70%-96%) for TARE after 3 months and 115% (IQR: 70%-46%) for PVE versus 86% (IQR: 58%-111%) for TARE after 6 months. A strong correlation was observed between radiation dose (median 162 Gy, IQR: 139-175) and hypertrophy. CONCLUSIONS: PVE resulted in rapid hypertrophy within 1 month of the procedure, followed by a plateau, whereas TARE resulted in comparable hypertrophy by 3-6 months. TARE-induced hypertrophy correlated with radiation absorbed dose.


Assuntos
Embolização Terapêutica , Embucrilato/administração & dosagem , Óleo Etiodado/administração & dosagem , Artéria Hepática , Regeneração Hepática , Fígado/irrigação sanguínea , Veia Porta , Compostos Radiofarmacêuticos/administração & dosagem , Radioisótopos de Ítrio/administração & dosagem , Animais , Embolização Terapêutica/efeitos adversos , Embucrilato/toxicidade , Óleo Etiodado/toxicidade , Feminino , Artéria Hepática/diagnóstico por imagem , Hipertrofia , Injeções Intra-Arteriais , Injeções Intravenosas , Fígado/diagnóstico por imagem , Fígado/patologia , Modelos Animais , Veia Porta/diagnóstico por imagem , Compostos Radiofarmacêuticos/efeitos adversos , Suínos , Porco Miniatura , Fatores de Tempo , Radioisótopos de Ítrio/toxicidade
5.
Eur Radiol ; 30(2): 1221-1227, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31493210

RESUMO

OBJECTIVES: To evaluate the mid-term outcome of salvage radiofrequency ablation (RFA) treatment in patients who exhibited intrahepatic recurrence after major hepatectomy for colorectal liver metastases (CRCLM). METHODS: Observational study on 23 consecutive patients (mean age 59 ± 9 years; 14/9 male/female) who, after a single (11/23) or multiple rounds (12/23) of major hepatic surgery, developed recurrent CRCLM in the liver remnant. Patients with a maximum of three metastases measuring up to 3 cm, and without relevant extrahepatic disease, underwent CT-guided RFA. Using the Kaplan-Meier-method, median intrahepatic progression-free-survival (ihPFS) and overall survival (OS) times after salvage RFA were compared with the same patients' time between the respective last round of surgery and diagnosis of intrahepatic recurrence leading to RFA. RESULTS: Median follow-up was 26 months (range 12-103 months). Median ihPFS time after RFA was 8 months (range 1-81 months). Median ihPFS time after the respective last round of surgery and RFA in the same patients had been 5 months (range 1-23 months), thus yielding similar ihPFS times after surgery vs. after salvage RFA (p = 0.238; Mood's median test). After RFA, 15/23 (65%) of patients developed new hepatic metastases within the first year post-RFA. Median OS was 37 months, with a 1-year OS rate of 100%, 3-year OS rate of 57%, and 5-year OS rate of 24%. No major complications were observed. CONCLUSIONS: Patients who exhibit intrahepatic recurrence of CRCLM after major hepatectomy will experience intrahepatic recurrence after salvage RFA as well, and after similar time intervals. However, long-term ihPFS may still be achieved in some patients. KEY POINTS: • Patients who exhibit intrahepatic recurrence of colorectal liver metastases after major hepatectomy will experience intrahepatic recurrence after salvage RFA as well, and after similar time intervals. • About two-thirds of all patients develop new metastases elsewhere in the liver within 1 year after RFA. • However, long-term intrahepatic progression-free survival may still be achieved in some patients.


Assuntos
Neoplasias Colorretais/patologia , Hepatectomia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia/cirurgia , Ablação por Radiofrequência , Terapia de Salvação/métodos , Idoso , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Prognóstico , Intervalo Livre de Progressão , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
6.
J Vasc Interv Radiol ; 31(12): 2033-2042.e1, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33267950

RESUMO

PURPOSE: To examine predictors of midterm occlusion in portal and hepatic veins within or adjacent to the ablation zone after irreversible electroporation (IRE) of liver tumors. MATERIALS AND METHODS: This retrospective cohort analysis included 39 patients who underwent CT-guided IRE of liver tumors. Vessels within or adjacent to the ablation zone were identified on CT images acquired immediately after the procedure, and the positional relationships with the ablation zone (within/adjacent), locations (proximal/distal), and diameters (< 4 mm or ≥ 4 mm) were evaluated. Using contrast-enhanced follow-up scans, each vessel was classified as patent, stenosed, or occluded. Associations between vessel occlusion and each variable were investigated. RESULTS: Overall, 33 portal veins and 64 hepatic veins were analyzed. Follow-up scans showed occlusion in 12/33 (36.7%) portal veins and 17/64 (26.6%) hepatic veins. Vessels within the ablation zone were occluded significantly more frequently than vessels adjacent to the ablation zone (portal: 55.6% [10/18] vs 13.3% [2/15], P = .04; hepatic: 45.4% [15/33] vs 6.4% [2/31], P = .011). Vessels with a diameter < 4 mm were also occluded significantly more frequently than vessels with a diameter ≥ 4 mm (portal: 72.7% [8/11] vs 18.1% [4/22], P = .011; hepatic: 54.8% [17/31] vs 0% [0/33], P < .001). The respective positive and negative predictive values for occlusion of vessels categorized as both within and < 4 mm were 88% (7/8) and 82% (20/25) for portal veins and 79% (15/19) and 96% (43/45) for hepatic veins. CONCLUSIONS: Midterm vessel occlusion after liver IRE could be predicted with relatively high accuracy by assessing ablation location and vessel diameter.


Assuntos
Técnicas de Ablação/efeitos adversos , Eletroporação , Veias Hepáticas , Neoplasias Hepáticas/cirurgia , Veia Porta , Doenças Vasculares/etiologia , Adulto , Idoso , Constrição Patológica , Feminino , Veias Hepáticas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem
7.
World J Surg Oncol ; 18(1): 140, 2020 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-32580729

RESUMO

BACKGROUND: Associating liver partition and portal vein ligation for staged hepatectomy (ALPPS) and two stage hepatectomy with inter-stage portal vein embolization (TSH/PVE) are surgical maneuvers applied in patients with advanced malignancies considered unresectable by means of conventional liver surgery. The aim of this report is to compare the oncologic outcome and technical feasibility of ALPPS and TSH/PVE in the scenario of colorectal liver metastases (CRLM). METHODS: All consecutive patients who underwent either ALPPS or TSH/PVE for CRLM between 2011 and 2017 in one hepatobiliary center were analyzed and compared regarding perioperative and long-term oncologic outcome. RESULTS: A cohort of 58 patients who underwent ALPPS (n = 21) or TSH/PVE (n = 37) was analyzed. The median overall survival (OS) was 28 months and 34 months after ALPPS and TSH/PVE (p = 0.963), respectively. The median recurrence-free survival (RFS) was higher following ALPPS with 19 months than following TSH/PVE with 10 months, but marginally failed to achieve statistical significance (p = 0.05). There were no differences in morbidity and mortality after stages 1 and 2. Patients undergoing ALPPS due to insufficient hypertrophy after TSH/PVE (rescue-ALPPS) displayed similar oncologic outcome as patients treated by conventional ALPPS or TSH/PVE (p = 0.971). CONCLUSIONS: ALPPS and TSH/PVE show excellent technical feasibility and comparable long-term oncologic outcome in CRLM. Rescue ALPPS appears to be a viable option for patients displaying insufficient hypertrophy after a TSH/PVE approach.


Assuntos
Neoplasias Colorretais/cirurgia , Embolização Terapêutica/métodos , Hepatectomia/métodos , Neoplasias Hepáticas/cirurgia , Veia Porta/cirurgia , Idoso , Neoplasias Colorretais/patologia , Feminino , Humanos , Ligadura , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
8.
Eur Radiol ; 29(11): 6300-6308, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31101968

RESUMO

OBJECTIVES: We conducted an in vivo trial to investigate the safety and efficacy of a newly developed system for the application of a combined therapy consisting of irreversible electroporation (IRE) and electrochemotherapy (IRECT) in the liver. The system is conceived as a single-needle multitined applicator with expandable electrodes that allow interstitial injection of fluids, e.g., chemotherapy. METHODS: Experiments were conducted in ten domestic pigs. The applicator was placed in different liver lobes under CT guidance. In one lobe, the applicator was used for conventional IRE (1500 V, 120 pulses, pulse length 100 µs). In the other lobe, the same procedure was performed preceded by the injection of a doxorubicin mixture through the expandable electrodes (IRECT). Contrast-enhanced CT and MRI were performed on days 1, 3, and 7 after the procedure. Accordingly, three animals were sacrificed on days 1, 3, and 7 after the imaging and ablation volumes were evaluated histopathologically. Related t test was used to compare the groups. RESULTS: Technical success was achieved in 9/10 experiments. One animal deceased during the intervention because of ventricular fibrillation. Follow-up CT 1 and 3 days after intervention showed a significant (p < 0.05) difference in the ablation volumes of IRECT vs IRE, respectively, of 4.47 ± 1.78 ml vs 2.51 ± 0.93 ml and of 3.39 ± 1.05 vs 1.53 ± 0.78 ml. CONCLUSIONS: IRECT using the newly developed system proved to be effective and provided significantly larger ablation volumes compared with IRE alone. However, ECG triggering is a necessary prerequisite to allow a safe application of the system. KEY POINTS: • Working on the geometry of the IRE applicator in terms of expandable electrodes may overcome the current limitations of IRE resulting from the placement of multiple electrodes. • Efficacy of IRE ablations can be enhanced by the interstitial application of chemotherapy in the periphery of ablation areas.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Eletroquimioterapia/métodos , Eletroporação/métodos , Animais , Antibióticos Antineoplásicos/administração & dosagem , Doxorrubicina/administração & dosagem , Eletroquimioterapia/efeitos adversos , Eletrodos , Eletroporação/instrumentação , Fígado/cirurgia , Imageamento por Ressonância Magnética , Agulhas , Sus scrofa , Suínos
9.
J Surg Res ; 240: 156-164, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30933829

RESUMO

BACKGROUND: Aortic aneurysms in the viscerorenal-segment are nowadays treatable by endovascular means. Previously, new endograft techniques were only tested in healthy animals. We aimed to establish a new large animal model for testing complex endovascular stent techniques preclinically. METHODS: In sheep, four juxtarenal and two type IV thoracoabdominal aortic aneurysms were surgically created via a retroperitoneal approach. Two pieces out of a 10 × 15-cm bovine pericardial patch were sewn with the healthy aorta longitudinally. The viscerorenal segment was clamped, and the aorta was incised longitudinally. Then, the patches were longitudinally sewn together. In the meantime, antegrade flow through the native part of the aorta was already established by tangential clamping. Computed tomography angiography was performed after 4, 8, and 52 wk. RESULTS: Technical success was 100%. The median surgical procedure time was 3 h, the median blood loss was 210 mL, and the viscerorenal-segment clamping time was 2-4 min. The animals started drinking 1 h after arousal from anesthesia. One animal died after 1 wk because of delayed bleeding and another died after 1 y because of aneurysm rupture by a secondary bacterial infection. Four animals survived. The proximal landing zone diameter and the clock position of the vessel were stable over 52 wk. CONCLUSIONS: Surgical creation of an aortic aneurysm in the viscerorenal-segment in sheep was successful, without an ischemia/reperfusion injury. This animal model offers a new platform for evaluating innovative endovascular therapy options in vivo.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Modelos Animais de Doenças , Animais , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Ovinos , Resultado do Tratamento
10.
Int J Mol Sci ; 20(6)2019 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-30909504

RESUMO

Hepatocellular carcinoma (HCC) is the most common primary tumor of the liver and its mortality is third among all solid tumors, behind carcinomas of the lung and the colon. Despite continuous advancements in the management of this disease, the prognosis for HCC remains inferior compared to other tumor entities. While orthotopic liver transplantation (OLT) and surgical resection are the only two curative treatment options, OLT remains the best treatment strategy as it not only removes the tumor but cures the underlying liver disease. As the applicability of OLT is nowadays limited by organ shortage, major liver resections ⁻ even in patients with underlying chronic liver disease ⁻ are adopted increasingly into clinical practice. Against the background of the oftentimes present chronical liver disease, locoregional therapies have also gained increasing significance. These strategies range from radiofrequency ablation and trans-arterial chemoembolization to selective internal radiation therapy and are employed in both curative and palliative intent, individually, as a bridging to transplant or in combination with liver resection. The choice of the appropriate treatment, or combination of treatments, should consider the tumor stage, the function of the remaining liver parenchyma, the future liver remnant volume and the patient's general condition. This review aims to address the topic of multimodal treatment strategies in HCC, highlighting a multidisciplinary treatment approach to further improve outcome in these patients.


Assuntos
Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Animais , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/mortalidade , Terapia Combinada/efeitos adversos , Terapia Combinada/métodos , Comorbidade , Gerenciamento Clínico , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/mortalidade , Resultado do Tratamento
11.
Radiology ; 285(3): 1023-1031, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28799842

RESUMO

Purpose To investigate the efficacy and safety of irreversible electroporation (IRE) in the treatment of hepatic tumors not suitable for thermal ablation (radiofrequency ablation [RFA] or microwave ablation). Materials and Methods This was an institutional review board-approved prospective study in 29 patients (15 men, 14 women; mean age, 63 years ± 12 [standard deviation]) with 43 primary (n = 8) or secondary (n = 35) malignant liver tumors who underwent computed tomography (CT)-guided IRE. All target tumors were located immediately adjacent to major hepatic veins, portal veins, or both; thus, they were not considered suitable for RFA or microwave ablation. Patients underwent postinterventional CT and magnetic resonance (MR) imaging. Systematic follow-up MR imaging was performed for 24 months on average to assess complete ablation, intrahepatic tumor recurrence, and complications. The 95% confidence intervals (CIs) were determined for the rate of bile duct strictures, incomplete ablation, and tumor recurrence. Results Complete ablation was achieved in 40 (93%; 95% CI: 85, 100) of 43 target tumors, with a safety margin of 5-10 mm, and was confirmed at immediate postinterventional CT and MR imaging. In 13 (33%; 95% CI: 18, 47) of 40 completely ablated tumors, intrahepatic tumor recurrence was observed at 2-18 months. However, only two (15%; 95% CI: 0, 35) of these 13 tumors were observed within the ablation zone. In the remaining 11 (85%; 95% CI: 65, 100), tumor growth was observed alongside the needle tract. None of the two true local recurrences occurred at the site of the vessel. All adjacent vessels remained perfused at follow-up. Five (24%; 95% CI: 5, 39) of 21 patients with target tumors adjacent to portal veins developed mild to moderate cholestasis 2-6 weeks after IRE. Conclusion IRE is useful to avoid incomplete ablation secondary to heat-sink effects and damage to major blood vessels; however, needle tract seeding is observed in 26% of treated tumors, and IRE induces sufficient local heating to bile ducts in 24% of ablations. © RSNA, 2017.


Assuntos
Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/métodos , Eletroporação/métodos , Veias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Veia Porta/diagnóstico por imagem , Doenças Vasculares/etiologia , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/prevenção & controle
12.
J Vasc Interv Radiol ; 28(1): 60-63, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28007080

RESUMO

Patients with locally advanced pancreatic cancer who undergo distal pancreatectomy with resection of the celiac axis (CA) are at risk for postoperative hepatic or gastric ischemia if collateral blood flow from the superior mesenteric artery (SMA) via the gastroduodenal artery is insufficient. This study presents a technique for preoperative angiographic evaluation of these collateral vessels by using an AMPLATZER Vascular Plug to temporarily occlude the CA or common hepatic artery while simultaneously performing digital subtraction angiography of the SMA. If collateral vessels are deemed sufficient, the plug can subsequently be released for permanent occlusion with the intent to enhance the blood flow in these collateral vessels.


Assuntos
Artéria Celíaca/cirurgia , Duodeno/irrigação sanguínea , Embolização Terapêutica/métodos , Artéria Hepática , Pancreatectomia , Neoplasias Pancreáticas/cirurgia , Circulação Esplâncnica , Estômago/irrigação sanguínea , Idoso , Angiografia Digital , Artéria Celíaca/diagnóstico por imagem , Artéria Celíaca/fisiopatologia , Circulação Colateral , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Desenho de Equipamento , Feminino , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/fisiopatologia , Humanos , Circulação Hepática , Masculino , Artéria Mesentérica Superior/diagnóstico por imagem , Artéria Mesentérica Superior/fisiopatologia , Pessoa de Meia-Idade , Pancreatectomia/efeitos adversos , Neoplasias Pancreáticas/patologia , Complicações Pós-Operatórias/prevenção & controle , Resultado do Tratamento
13.
Minim Invasive Ther Allied Technol ; 26(1): 15-22, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27686414

RESUMO

OBJECTIVES: To develop an electromagnetic navigation technology for transjugular intrahepatic portosystemic shunt (TIPS) creation and translate it from phantom to an in-vivo large animal setting. MATERIAL AND METHODS: A custom-designed device for TIPS creation consisting of a stylet within a 5 French catheter as well as a software prototype were developed that allow real-time tip tracking of both stylet and catheter using an electromagnetic tracking system. Feasibility of navigated TIPSS creation was tested in a phantom by two interventional radiologists (A/B) followed by in-vivo testing evaluation in eight domestic pigs. Procedure duration and number of attempts needed for puncture of the portal vein were recorded. RESULTS: In the phantom setting, intervention time to gain access to the portal vein (PV) was 144 ± 67 s (A) and 122 ± 51 s (B), respectively. In the in-vivo trials, TIPS could be successfully completed in five out of eight animals. Mean time for the complete TIPS was 245 ± 205 minutes with a notable learning curve towards the last animal. CONCLUSIONS: TIPS creation with the use of electromagnetic tracking technology proved to be feasible in-vitro as well as in-vivo. The system may be useful to facilitate challenging TIPSS procedures.


Assuntos
Fenômenos Eletromagnéticos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Derivação Portossistêmica Transjugular Intra-Hepática/instrumentação , Ultrassonografia de Intervenção/métodos , Animais , Desenho de Equipamento , Suínos
14.
Minim Invasive Ther Allied Technol ; 25(6): 323-328, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27333262

RESUMO

PURPOSE: A novel approach for arterial bypass grafting using exclusively endovascular techniques was established in-vitro in a phantom model. MATERIAL AND METHODS: The experimental setting consisted of a gel-wax phantom with two embedded parallel fluid-filled silicon tubes simulating the superficial femoral vessels. Through an 8-French sheath, a re-entry catheter (OUTBACK®, Cordis) was placed in the simulated artery and used to puncture the vascular wall. Then a 0.014-inch guide wire was advanced into the extravascular space. With the curved needle of the re-entry catheter, the guide wire was steered on a course parallel to the vessel wall in the extravascular space for 5-10 cm. At the desired reentry site, the re-entry catheter was used to puncture the vascular wall again in order to regain access to the endovascular space. Once the tip of the guide wire had safely been placed in the vascular lumen, a self-expandable stent graft (VIABAHN® GORE®) was deployed to complete the extraluminal bypass. RESULTS: Endovascular placement of an extraluminal bypass was successfully achieved in 20 attempts. The mean duration of the procedure amounted to 14:58 (minutes: seconds) (SD ± 3:56). CONCLUSIONS: This in-vitro study suggests that endovascular placement of an extraluminal arterial bypass graft is technically feasible.


Assuntos
Implante de Prótese Vascular/métodos , Ponte de Artéria Coronária/métodos , Procedimentos Endovasculares/métodos , Estudos de Viabilidade , Humanos , Modelos Biológicos
15.
BMC Med Imaging ; 14: 30, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-25178653

RESUMO

BACKGROUND: To investigate the impact of high pitch cardiac CT vs. retrospective ECG gated CT on the quantification of calcified vessel stenoses, with assessment of the influence of tube voltage, reconstruction kernel and heart rate. METHODS: A 4D cardiac movement phantom equipped with three different plaque phantoms (12.5%, 25% and 50% stenosis at different calcification levels), was scanned with a 128-row dual source CT scanner, applying different trigger types (gated vs. prospectively triggered high pitch), tube voltages (100-120 kV) and heart rates (50-90 beats per minute, bpm). Images were reconstructed using different standard (B26f, B46f, B70f) and iterative (I26f, I70f) convolution kernels. Absolute and relative plaque sizes were measured and statistically compared. Radiation dose associated with the different methods (gated vs. high pitch, 100 kV vs. 120 kV) were compared. RESULTS: Compared to the known diameters of the phantom plaques and vessels both CT-examination techniques overestimated the degrees of stenoses. Using the high pitch CT-protocol plaques appeared larger (0.09 ± 0.31 mm, 2 ± 8 percent points, PP) in comparison to the ECG-gated CT-scans. Reducing tube voltage had a similar effect, resulting in higher grading of the same stenoses by 3 ± 8 PP. In turn, sharper convolution kernels lead to a lower grading of stenoses (differences of up to 5%). Pairwise comparison of B26f and I26f, B46f and B70f, and B70f and I70f showed differences of 0-1 ± 6-8 PP of the plaque depiction. Motion artifacts were present only at 90 bpm high pitch experiments. High-pitch protocols were associated with significantly lower radiation doses compared with the ECG-gated protocols (258.0 mGy vs. 2829.8 mGy CTDIvol, p ≤ 0.0001). CONCLUSION: Prospectively triggered high-pitch cardiac CT led to an overestimation of plaque diameter and degree of stenoses in a coronary phantom. This overestimation is only slight and probably negligible in a clinical situation. Even at higher heart rates high pitch CT-scanning allowed reliable measurements of plaque and vessel diameters with only slight differences compared ECG-gated protocols, although motion artifacts were present at 90 bpm using the high pitch protocols.


Assuntos
Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia/métodos , Tomografia Computadorizada Quadridimensional/métodos , Calcificação Vascular/diagnóstico por imagem , Angiografia Coronária/métodos , Vasos Coronários/patologia , Tomografia Computadorizada Quadridimensional/instrumentação , Frequência Cardíaca , Humanos , Imagens de Fantasmas , Doses de Radiação
16.
Med Image Anal ; 92: 103059, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38104402

RESUMO

Artificial intelligence (AI) has a multitude of applications in cancer research and oncology. However, the training of AI systems is impeded by the limited availability of large datasets due to data protection requirements and other regulatory obstacles. Federated and swarm learning represent possible solutions to this problem by collaboratively training AI models while avoiding data transfer. However, in these decentralized methods, weight updates are still transferred to the aggregation server for merging the models. This leaves the possibility for a breach of data privacy, for example by model inversion or membership inference attacks by untrusted servers. Somewhat-homomorphically-encrypted federated learning (SHEFL) is a solution to this problem because only encrypted weights are transferred, and model updates are performed in the encrypted space. Here, we demonstrate the first successful implementation of SHEFL in a range of clinically relevant tasks in cancer image analysis on multicentric datasets in radiology and histopathology. We show that SHEFL enables the training of AI models which outperform locally trained models and perform on par with models which are centrally trained. In the future, SHEFL can enable multiple institutions to co-train AI models without forsaking data governance and without ever transmitting any decryptable data to untrusted servers.


Assuntos
Neoplasias , Radiologia , Humanos , Inteligência Artificial , Aprendizagem , Neoplasias/diagnóstico por imagem , Processamento de Imagem Assistida por Computador
17.
Acad Radiol ; 31(5): 1784-1791, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38155024

RESUMO

RATIONALE AND OBJECTIVES: The prognostic role of pericardial effusion (PE) in Covid 19 is unclear. The aim of the present study was to estimate the prognostic role of PE in patients with Covid 19 in a large multicentre setting. MATERIALS AND METHODS: This retrospective study is a part of the German multicenter project RACOON (Radiological Cooperative Network of the Covid 19 pandemic). The acquired sample comprises 1197 patients, 363 (30.3%) women and 834 (69.7%) men. In every case, chest computed tomography was analyzed for PE. Data about 30-day mortality, need for mechanical ventilation and need for intensive care unit (ICU) admission were collected. Data were evaluated by means of descriptive statistics. Group differences were calculated with Mann-Whitney test and Fisher exact test. Uni-and multivariable regression analyses were performed. RESULTS: Overall, 46.4% of the patients were admitted to ICU, mechanical lung ventilation was performed in 26.6% and 30-day mortality was 24%. PE was identified in 159 patients (13.3%). The presence of PE was associated with 30-day mortality: HR= 1.54, CI 95% (1.05; 2.23), p = 0.02 (univariable analysis), and HR= 1.60, CI 95% (1.03; 2.48), p = 0.03 (multivariable analysis). Furthermore, density of PE was associated with the need for intubation (OR=1.02, CI 95% (1.003; 1.05), p = 0.03) and the need for ICU admission (OR=1.03, CI 95% (1.005; 1.05), p = 0.01) in univariable regression analysis. The presence of PE was associated with 30-day mortality in male patients, HR= 1.56, CI 95%(1.01-2.43), p = 0.04 (multivariable analysis). In female patients, none of PE values predicted clinical outcomes. CONCLUSION: The prevalence of PE in Covid 19 is 13.3%. PE is an independent predictor of 30-day mortality in male patients with Covid 19. In female patients, PE plays no predictive role.


Assuntos
COVID-19 , Derrame Pericárdico , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , COVID-19/mortalidade , COVID-19/epidemiologia , COVID-19/diagnóstico por imagem , COVID-19/complicações , Estudos Retrospectivos , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/epidemiologia , Idoso , Pessoa de Meia-Idade , Prognóstico , Alemanha/epidemiologia , Respiração Artificial/estatística & dados numéricos , SARS-CoV-2 , Unidades de Terapia Intensiva , Idoso de 80 Anos ou mais
18.
Acta Radiol ; 54(5): 521-5, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23474769

RESUMO

BACKGROUND: Hematoma is a common complication following arterial puncture. To date no device that allows sealing of an arterial puncture site with in-situ catheter has been developed. PURPOSE: To evaluate a newly developed arterial sealing device for endovascular catheters in an in-vivo experimental setting. MATERIAL AND METHODS: A peelable collagen-based vascular sealing device for endovascular catheters was tested in acute (follow-up: 4 h; n = 2) and chronic (follow-up: 1 week; n = 4) settings in the femoral artery (FA) of sheep. After implantation correct position of the device as well as patency of the FA were verified angiographically. In the chronic group, hematoma was excluded and patency of FA was assured using color Doppler ultrasound 1 and 3 days after the procedure. After 1 week a final ultrasound and an angiography were performed for final evaluation. Thereafter, the animals were sacrificed and the puncture site was dissected and analyzed macroscopically. RESULTS: Sufficient sealing of the puncture site could be observed in all animals. In acute and chronic experiments, neither a hematoma at the puncture site nor other complications were observed after positioning the sealing device. Follow-up color Doppler ultrasounds (CDUS) and final angiography revealed patent FAs in all animals. Macroscopic evaluation of dissection material proved collagen plug and catheter being in place. CONCLUSION: Our preliminary in-vivo results demonstrate a safe and convenient vascular sealing system for endovascular catheters. No acute or chronic complications were observed.


Assuntos
Cateteres de Demora , Hemostasia Cirúrgica/instrumentação , Dispositivos de Oclusão Vascular , Angiografia , Animais , Meios de Contraste , Modelos Animais de Doenças , Desenho de Equipamento , Artéria Femoral , Fluoroscopia , Hematoma/prevenção & controle , Iohexol/análogos & derivados , Punções , Carneiro Doméstico
19.
Sci Rep ; 13(1): 22576, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38114729

RESUMO

Developing robust artificial intelligence (AI) models that generalize well to unseen datasets is challenging and usually requires large and variable datasets, preferably from multiple institutions. In federated learning (FL), a model is trained collaboratively at numerous sites that hold local datasets without exchanging them. So far, the impact of training strategy, i.e., local versus collaborative, on the diagnostic on-domain and off-domain performance of AI models interpreting chest radiographs has not been assessed. Consequently, using 610,000 chest radiographs from five institutions across the globe, we assessed diagnostic performance as a function of training strategy (i.e., local vs. collaborative), network architecture (i.e., convolutional vs. transformer-based), single versus cross-institutional performance (i.e., on-domain vs. off-domain), imaging finding (i.e., cardiomegaly, pleural effusion, pneumonia, atelectasis, consolidation, pneumothorax, and no abnormality), dataset size (i.e., from n = 18,000 to 213,921 radiographs), and dataset diversity. Large datasets not only showed minimal performance gains with FL but, in some instances, even exhibited decreases. In contrast, smaller datasets revealed marked improvements. Thus, on-domain performance was mainly driven by training data size. However, off-domain performance leaned more on training diversity. When trained collaboratively across diverse external institutions, AI models consistently surpassed models trained locally for off-domain tasks, emphasizing FL's potential in leveraging data diversity. In conclusion, FL can bolster diagnostic privacy, reproducibility, and off-domain reliability of AI models and, potentially, optimize healthcare outcomes.


Assuntos
Inteligência Artificial , Aprendizagem , Reprodutibilidade dos Testes , Generalização Psicológica , Radiografia
20.
Sci Rep ; 13(1): 6046, 2023 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-37055456

RESUMO

Due to the rapid advancements in recent years, medical image analysis is largely dominated by deep learning (DL). However, building powerful and robust DL models requires training with large multi-party datasets. While multiple stakeholders have provided publicly available datasets, the ways in which these data are labeled vary widely. For Instance, an institution might provide a dataset of chest radiographs containing labels denoting the presence of pneumonia, while another institution might have a focus on determining the presence of metastases in the lung. Training a single AI model utilizing all these data is not feasible with conventional federated learning (FL). This prompts us to propose an extension to the widespread FL process, namely flexible federated learning (FFL) for collaborative training on such data. Using 695,000 chest radiographs from five institutions from across the globe-each with differing labels-we demonstrate that having heterogeneously labeled datasets, FFL-based training leads to significant performance increase compared to conventional FL training, where only the uniformly annotated images are utilized. We believe that our proposed algorithm could accelerate the process of bringing collaborative training methods from research and simulation phase to the real-world applications in healthcare.


Assuntos
Algoritmos , Inteligência Artificial , Simulação por Computador , Instalações de Saúde , Tórax
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA