Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 143(11): 6589-6597, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37418006

RESUMO

INTRODUCTION: Self-monitoring is crucial to work progressively with a high-quality standard. A retrospective analysis is a valuable tool for studying the postoperative outcome of a prosthesis and for evaluating the learning process for the surgeon. MATERIALS AND METHODS: The learning process of one surgeon was analysed in 133 cases of hip arthroplasty. These were divided into seven groups representing the surgical years 2008-2014. Over the course of 3 postoperative years, a total of 655 radiographs were analysed at regarding three radiological quality parameters (centrum-collum-diaphyseal angle (CCD angle), intramedullary fit&fill ratio (FFR), and migration) and ancillary outcome parameters (Harris Hip Score (HHS), blood loss, operating time, and complications). This period was divided into five times: 1st-day post-op, 6 M, 12 M, 24 M, and 36 M. Bivariate Spearman's correlation analysis and pairwise comparisons were performed. RESULTS: The total collective achieved a proximal FFR of over 0.8. The distal prosthesis tip migrated and was located on the lateral cortex within the first months. The CCD angle initially showed a variation with a subsequent constant course. The HHS showed a significant increase (p < 0.001) to over 90 points postoperatively. Over time, the operating time and blood loss decreased. Intraoperative complications existed only at the beginning of the learning phase. A learning curve effect can be determined for almost all parameters by comparing the subject groups. CONCLUSIONS: Operative expertise was shown to gain through a learning curve, whereby postoperative results corresponded to the system philosophy of the short hip stem prosthesis. The distal FFR and the distal lateral distance could represent the principle of the prosthesis, which overall could be an interesting approach for verification of a new parameter.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Raios X , Curva de Aprendizado , Resultado do Tratamento , Desenho de Prótese
2.
Int J Mol Sci ; 23(5)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35269552

RESUMO

(1) Background: Synovial fluid (SF) from knee joints with osteoarthritis (OA) has increased levels of phospholipids (PL). We have reported earlier that TGF-ß and IGF-1 stimulate fibroblast-like synoviocytes (FLS) to synthesize increased amounts of PLs. The current study examined whether IL-1ß induces the release of PLs in FLS and the underlying mechanism. (2) Methods: Cultured human OA FLS were treated with IL-1ß alone and with pathway inhibitors or with synthetic liver X receptor (LXR) agonists. Cholesterol hydroxylases, ABC transporters, apolipoproteins (APO), LXR, sterol regulatory binding proteins (SREBPs), and 3-hydroxy-3-methylglutaryl-coenzyme A reductase (HMGCR) were analyzed by RT-PCR, Western blot, and ELISA. The release of radiolabeled PLs from FLS was determined, and statistical analysis was performed using R (N = 5-9). (3) Results: Like synthetic LXR agonists, IL-1ß induced a 1.4-fold greater release of PLs from FLS. Simultaneously, IL-1ß upregulated the level of the PL transporter ABCA1 and of cholesterol hydroxylases CH25H and CYP7B1. IL-1ß and T0901317 stimulated the expression of SREBP1c, whereas only T0901317 enhanced SREBP2, HMGCR, APOE, LXRα, and ABCG1 additionally. (4) Conclusions: IL-1ß partially controls PL levels in OA-SF by affecting the release of PLs from FLS. Our data show that IL-1ß upregulates cholesterol hydroxylases and thus the formation of oxysterols, which, as natural agonists of LXR, increase the level of active ABCA1, in turn enhancing the release of PLs.


Assuntos
Benzoatos/farmacologia , Benzilaminas/farmacologia , Interleucina-1beta/farmacologia , Osteoartrite/metabolismo , Fosfolipídeos/metabolismo , Sinoviócitos/citologia , Transportador 1 de Cassete de Ligação de ATP/genética , Células Cultivadas , Família 7 do Citocromo P450/genética , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Receptores X do Fígado/genética , Osteoartrite/genética , Esteroide Hidroxilases/genética , Líquido Sinovial/citologia , Líquido Sinovial/efeitos dos fármacos , Líquido Sinovial/metabolismo , Sinoviócitos/efeitos dos fármacos , Sinoviócitos/metabolismo
3.
J Biomech Eng ; 142(12)2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32601705

RESUMO

Cementless straight stems show very good survival rates. However, the more distal force application of straight stems may lead to release-related proximal stress-shielding. Nevertheless, this technical brief had the objective of conducting a biomechanical in vitro analysis comparing short stems with established straight stems with respect to their primary torsional stability. Two cementless short hip stems and three cementless straight hip stems were implanted in n = 5 synthetic femora each. Torsional torques were applied into the hip stems at a continuous interval of ±7 Nm. Micromotions were measured by six inductive extensometers on four different measurement levels. At the proximal measuring point, significantly smaller relative micromotions of the CLS® prosthesis could be detected compared to all other stem models (p < 0.05). In all stem models, smallest relative micromotions were found at the metaphyseal/diaphyseal measuring point. Only at the measuring point of the distal tips of the straight stems, statistically significantly lower relative micromotion of the CLS® stem compared to the Trendhip® stem could be found (p < 0.01). All the investigated stems generally display a rather comparable anchoring pattern and an almost physiological force application. Since the comparatively long straight stems present an anchoring pattern nearly identical to that of the examined short stems, a shortening of the established straight stems could be taken into consideration. This would offer the advantage of minimally invasive surgery and bone-saving resection as well as preservation of cancellous bone in case a revision would become necessary.


Assuntos
Prótese de Quadril , Artroplastia de Quadril , Fenômenos Biomecânicos , Fêmur , Desenho de Prótese , Estresse Mecânico
4.
Arch Orthop Trauma Surg ; 140(2): 247-253, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31786645

RESUMO

INTRODUCTION: Stress shielding may lead to aseptic loosening which is a common reason for implant failure. An established method to identify implants with risk of implant failure caused by aseptic loosening is to measure early migration of the stem with the "Ein Bild Roentgen Analyse" femoral component analysis (EBRA-FCA). Therefore, the aim of this study was to measure the migration of a cementless short stem prosthesis via EBRA-FCA to predict the future performance. MATERIALS AND METHODS: A total collective of 71 patients were treated with a cementless short hip stem prosthesis. Indications for surgery were primary coxarthrosis, dysplasia coxarthrosis or femoral head necrosis. After surgery, the patients were followed-up immediately after 3, 6, 12, 24, 36, and 48 months and X-ray images for EBRA-FCA measurements were taken. Axial caudal migration as well as the varus/valgus tilting of the prosthesis was determined. Possible influencing factors like BMI, age, diagnosis, gender or Harris Hip Score (HHS) on the migration of the stem were assessed. RESULTS: HHS increased significantly direct postoperatively (p < 0.001). At the second follow-up the average caudal migration was 0.42 ± 0.52 mm (range: 0.00-2.85 mm) (p < 0.001). A total of 14 patients underwent a caudal migration greater than 1.5 mm until 48 months. The initial varus and valgus tilts within the first 3 months were significant (p < 0.001). No correlations between BMI, age, diagnosis, gender or HHS and the migration as well as the tilting of the cementless short hip stem prosthesis were found. CONCLUSIONS: Although initial axial caudal migration as well as tilting tendencies in varus or valgus position can be detected, there is no marked migration of the examined prosthesis after the first 48 months. Likewise, no aseptic early loosening was detected throughout the study period, which indicates good osseointegration of the short stem prosthesis.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur , Prótese de Quadril/efeitos adversos , Falha de Prótese , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Humanos , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Radiografia
5.
Int Orthop ; 43(9): 2031-2037, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30178069

RESUMO

PURPOSE: The purpose of this study was to check the concept of the cementless Metha® short hip stem in order to find out whether proximal physiological load transfer can be achieved. METHODS: Fourty-three patients were included. Epidemiological factors were established. The Harris Hip Score was determined and measurement of bone mass density as well as osteodensitometric and radiological measurements was carried out pre-operatively, post-operatively, and after six, 12, 24, and 36 months. RESULTS: Harris Hip Score improved from 55.9 ± 12.4 pre-operatively to 94.8 ± 8.2 after 36 months (p < 0.001). After initial reduction of bone density in zones 1 and 7 up to six months post-operatively, there was a steady approximation of bone density to the initial values (p < 0.05). CONCLUSION: The Metha® short hip stem shows good clinical results. Furthermore, there is an increase of bone density in the proximal zones 1 and 7 between six and 36 months serving as a sign of physiological load transfer.


Assuntos
Artroplastia de Quadril/métodos , Necrose da Cabeça do Fêmur/cirurgia , Fêmur/cirurgia , Prótese de Quadril , Osseointegração , Osteoartrite do Quadril/cirurgia , Absorciometria de Fóton , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Fenômenos Biomecânicos , Cimentos Ósseos , Densidade Óssea/fisiologia , Cimentação , Feminino , Fêmur/diagnóstico por imagem , Fêmur/fisiopatologia , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/fisiopatologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/fisiopatologia , Estudos Prospectivos , Desenho de Prótese
6.
Int J Mol Sci ; 20(2)2019 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-30650648

RESUMO

Phospholipids (PLs) possess the unique ability to contribute to synovial joint lubrication. The aim of our study was to determine for the first time the effect of dexamethasone and some adrenergic and cholinergic agonists on the biosynthesis and release of PLs from human fibroblast-like synoviocytes (FLS). Osteoarthritic human knee FLS were treated with dexamethasone, terbutaline, epinephrine, carbachol, and pilocarpine, or the glucocorticoid receptor antagonist RU 486. Simultaneously PL biosynthesis was determined through the incorporation of stable isotope-labeled precursors into PLs. Radioactive isotope-labeled precursors were used to radiolabel PLs for the subsequent quantification of their release into nutrient media. Lipids were extracted and quantified using electrospray ionization tandem mass spectrometry or liquid scintillation counting. Dexamethasone significantly decreased the biosynthesis of phosphatidylcholine, phosphatidylethanolamine (PE), PE-based plasmalogen, and sphingomyelin. The addition of RU 486 abolished these effects. A release of PLs from FLS into nutrient media was not recognized by any of the tested agents. None of the adrenergic or cholinergic receptor agonists modulated the PL biosynthesis. We demonstrate for the first time an inhibitory effect of dexamethasone on the PL biosynthesis of FLS from human knees. Moreover, our study indicates that the PL metabolism of synovial joints and lungs are differently regulated.


Assuntos
Agonistas Adrenérgicos/farmacologia , Agonistas Colinérgicos/farmacologia , Dexametasona/farmacologia , Osteoartrite/patologia , Fosfolipídeos/metabolismo , Receptores Adrenérgicos/metabolismo , Receptores Colinérgicos/metabolismo , Sinoviócitos/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mifepristona/farmacologia , Modelos Biológicos , Osteoartrite/metabolismo , Fosfolipídeos/biossíntese , Sinoviócitos/efeitos dos fármacos
7.
Arch Orthop Trauma Surg ; 139(3): 405-410, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30506094

RESUMO

PURPOSE: The purpose of this study was to examine potential differences between patients under and over 60 years who underwent a total short hip stem arthroplasty in a 24-month follow-up in a clinical setting. METHODS: Sixty seven patients were included in this prospective study and divided in two groups. In the younger cohort 39 patients ≤ 59 years and in the older cohort 28 patients ≥ 60 years were included. Clinical and radiological examinations of the patients took place preoperatively, postoperatively and after 3, 6, 12 and 24 months. The Harris Hip Score (HHS) was raised as clinical examination. Changes of bone mass density (BMD), stress shielding, reactive lines, spot welds and sclerosing were examined as radiological analysis. RESULTS: The HHS improved from 53.6 ± 8.2 preoperative to 93.2 ± 9.6 in the younger cohort and for the older cohort from 57.6 ± 14.8 to 94.1 ± 7.6 after 24 months. BMD growth was detectable in regions of interest (ROI) 3 and 6 for both groups. Different results between the cohorts could only be detected in ROIs 4 and 5. The older cohort showed a loss of BMD of 5.95% in ROI 4 and 3.17% in ROI 5 after 24 months, whereas the younger cohort showed no loss of BMD in both ROIs. CONCLUSIONS: No significant differences or any influences of osseointegration and clinical outcome of the short hip stem for both groups were detectable. Lower losses (ROIs 1 and 2) and higher growths (ROIs 3, 4, 5) were discovered in younger patients and the HHS improved in both groups. Reasons for this result could be age, sex or the level of activity of the patients, but in both groups the short hip stem shows comparable results in clinical as well as in radiological examination. We conclude that the short hip stem seems to be an adequate treatment also for older patients.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Osseointegração/fisiologia , Adulto , Fatores Etários , Idoso , Densidade Óssea/fisiologia , Seguimentos , Quadril/diagnóstico por imagem , Quadril/cirurgia , Prótese de Quadril , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Cell Tissue Bank ; 17(3): 427-37, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27344440

RESUMO

Revision surgery of joint replacements is increasing and raises the demand for allograft bone since restoration of bone stock is crucial for longevity of implants. Proceedings of bone grafts influence the biological and mechanic properties differently. This study examines the effect of thermodisinfection on mechanic properties of cancellous bone. Bone cylinders from both femoral heads with length 45 mm were taken from twenty-three 6-8 months-old piglets, thermodisinfected at 82.5 °C according to bone bank guidelines and control remained native. The specimens were stored at -20 °C immediately and were put into 21 °C Ringer's solution for 3 h before testing. Shear and pressure modulus were tested since three point bending force was examined until destruction. Statistical analysis was done with non-parametric Wilcoxon, t test and SPSS since p < 0.05 was significant. Shear modulus was significantly reduced by thermodisinfection to 1.02 ± 0.31 GPa from 1.28 ± 0.68 GPa for unprocessed cancellous bone (p = 0.029) since thermodisinfection reduced pressure modulus not significantly from 6.30 ± 4.72 GPa for native specimens to 4.97 ± 2.23 GPa and maximum bending force was 270.03 ± 116.68 N for native and 228.80 ± 70.49 N for thermodisinfected cancellous bone. Shear and pressure modulus were reduced by thermodisinfection around 20 % and maximum bending force was impaired by about 15 % compared with native cancellous bone since only the reduction of shear modulus reached significance. The results suggest that thermodisinfection similarly affects different mechanic properties of cancellous bone and the reduction of mechanic properties should not relevantly impair clinical use of thermodisinfected cancellous bone.


Assuntos
Osso Esponjoso/fisiologia , Desinfecção/métodos , Temperatura , Animais , Fenômenos Biomecânicos , Estresse Mecânico , Sus scrofa , Torção Mecânica , Suporte de Carga
9.
Knee Surg Sports Traumatol Arthrosc ; 23(12): 3729-35, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25218576

RESUMO

PURPOSE: Matrix-induced autologous chondrocyte implantation (MACI) has demonstrated effectiveness in treating isolated cartilage defects of the knee but medium- and long-term evidence and information on the management of postoperative complications or partially successful cases are sparse. This study hypothesised that MACI is effective for up to 5 years and that patients with posttreatment problems may go on to obtain clinical benefit from other interventions. METHODS: A follow-on, prospective case series of patients recruited into a previous controlled, randomised, prospective study or newly enroled. Patients were followed up 6, 12, 24 and 60 months after surgery. Outcome measures were Tegner (activity levels) and Lysholm (pain, stability, gait, clinical symptoms) scores. Zone-specific subgroups were analysed 6, 12 and 24 months postoperatively. RESULTS: Sixty-five patients were treated with MACI. Median Tegner score improved from II to IV at 12 months; an improvement maintained to 60 months. Mean Lysholm score improved from 28.5 to 76.6 points (±19.8) at 24 months, settling back to 75.5 points after 5 years (p > 0.0001). No significant differences were identified in the zone-specific analysis. Posttreatment issues (N = 12/18.5 %) were resolved with microfracture, debridement, OATS or bone grafting. CONCLUSIONS: MACI is safe and effective in the majority of patients. Patients in whom treatment is only partially successful can go on to obtain clinical benefit from other cartilage repair options. This study adds to the clinical evidence on the MACI procedure, offers insight into likely treatment outcomes, and highlights MACI's usefulness as part of an armamentarium of surgical approaches to the treatment of isolated knee defects. LEVEL OF EVIDENCE: Prospective case control study with no control group, Level III.


Assuntos
Cartilagem Articular/cirurgia , Condrócitos/transplante , Traumatismos do Joelho/cirurgia , Articulação do Joelho/cirurgia , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Transplante Autólogo , Resultado do Tratamento
10.
Int Orthop ; 39(3): 411-6, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25233946

RESUMO

PURPOSE: The purpose of this study was to identify the shortest possible length of an established cemented hip stem in order to reduce stress shielding and optimise its bending behaviour. METHODS: Twenty-five prototypes from the same batch (five for each stem length) were included. Lengths resulted from the original length (100 %) and four distal shortenings to 94, 88, 83 and 78 % of original length. For standardised implantations, synthetic femurs were prepared. Relative movements under axial torque and stem bending under varus-valgus torque applications were investigated consecutively. Analyses of variance (ANOVA) were applied to detect differences between lengths. RESULTS: The maximum torque transfer occurred at the level of the lesser trochanter (p < 0.01). In particular, for the 78 % version, relative motion of the stem tip increased significantly compared with all other lengths (p = 0.02-0.04). Comparable findings were made for mean overall movements. In regards to varus-valgus torque, both the distal tip and the proximal shoulder always bent in the same direction following the femoral deflection. For the 83 % version bending of stem's shoulder was increased compared with the other length (p = 0.01 - 0.02), whereas tip bending was always comparable (p = 0.45-0.91). CONCLUSIONS: Our data show that the intention to preclinically optimise the mechanical behaviour of cemented stems by modifying their length seems to be a reasonable option. Advantages are decreased inner bone stiffening to reduce stress shielding and a lower cement volume, which is involved in cellular interactions.


Assuntos
Prótese de Quadril , Artroplastia de Quadril , Cimentação/métodos , Articulação do Quadril/cirurgia , Humanos , Desenho de Prótese , Rotação , Torque
11.
Int Orthop ; 39(3): 449-54, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25256851

RESUMO

PURPOSE: The purpose of our study was to investigate the change of sports activities before and after medial unicompartmental knee arthroplasty (UKA) with the use of the Heidelberg Sports Activity Score (HAS). METHODS: The Heidelberg Sports Activity Score (HAS) as well as FFb-H-OA, Oxford-12-Score, Tegner, UCLA and ACS were carried out to assess sports activities in 157 patients with medial osteoarthritis of the knee joint before and after UKA. The newly developed HAS also records the important duration and the sporting activity. RESULTS: Patients practiced sports in a more deliberate manner after UKA. Hiking, cycling and swimming were the sports most increased after surgery. Patients ≤65 years of age were sportier than those >65 years. Men were sportier than women, but all became sportier postoperatively. Patients with a high body mass index (BMI) are less sporty at first, but then increase their sports activity after surgery. CONCLUSIONS: HAS is an effective and valid assessment scale for evaluating sports activities before and after knee replacement.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Recuperação de Função Fisiológica , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Período Pós-Operatório , Qualidade de Vida , Esportes , Inquéritos e Questionários
12.
Arch Orthop Trauma Surg ; 135(11): 1609-14, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26272583

RESUMO

INTRODUCTION: The purpose of this study consisted in examining the effects of fit and fill ratio of the Metha prosthesis (BBraun, Aesculap, Tuttlingen, Germany) on radiological and clinical outcomes at a follow-up of 1 year. METHODS: 40 patients were included. Fit and fill ratio measurements, radiological and clinical examinations were performed preoperatively and postoperatively. Correlations were established between fit and fill ratio, and potential factors like sex, age, body mass index, Harris Hip Score and changes of radiological signs. RESULTS: The whole cohort (100%) had a tight fit and fill ratio (>0.8) at the proximal level and at each follow-up. "Champagne-flute" configuration provoked high distal tight-fit and fill ratio. Poor distal fit and fill ratio compared to the proximal and the mid-stem level was measurable at each follow-up (p < 0.05). Correlations between fit and fill ratio and preoperative femur configurations were detectable. CONCLUSIONS: Implanting the Metha prosthesis induces tight fit and fill ratio at the proximal and coated sections. Preoperative femur configuration should be considered to achieve best fit and fill situation and therefore excellent primary stability. In most cases "normal" and "stove-pipe" configurations provide good proximal fit and fill. Since "champagne-flute" configuration induces undesirable tight distal fit and fill ratio the size of the Metha (®) stem should be adequately increased to achieve a more proximal load transmission.


Assuntos
Artroplastia de Quadril , Fêmur/cirurgia , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Feminino , Humanos , Masculino , Desenho de Prótese
13.
Int Orthop ; 38(10): 2045-50, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25027975

RESUMO

PURPOSE: The purpose of this study was to examine the concept of proximal load initiation of a total short-stemmed hip arthroplasty (Metha BBraun, Aesculap, Tuttlingen, Germany) on the basis of bone variations by means of osteodensitometric dual energy X-ray absorptiometry and radiologic measurements. METHODS: After power analysis 40 patients were included in this study. DXA examination, radiological and clinical follow-up was performed pre-operatively and postoperatively. Socio-demographic relevancies of bone progression and radiological changes were raised epidemiologically and clinically. RESULTS: Improvement of the Harris hip score from 54.7 points preoperative to 96.7 points postoperative was detected (p < 0.01). Loss of summarized overall net average bone mass density (netavg BMD) could only be manifested after six months compared to the netavg BMD of the postoperative measurement (p < 0.01). After six and 12 months BMD atrophy was shown mainly in regions of interest (ROI) 1, 4 and 7. Positive correlations between changes of BMD and age, male sex and BMI were detectable. No stem had to be revised. CONCLUSIONS: The Metha implant shows excellent osseointegration at the coated area of the stem without factors of aseptic loosening in the short term. This study shows that parameters like age, sex and BMI influence BMD progression and stress shielding. Metha implant shows excellent results especially in young patients with good bone stock.


Assuntos
Artroplastia de Quadril/instrumentação , Densidade Óssea , Fêmur/fisiopatologia , Prótese de Quadril , Artropatias/cirurgia , Osseointegração , Absorciometria de Fóton , Adulto , Idoso , Fenômenos Biomecânicos , Cimentação , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Artropatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Risco
14.
J Orthop ; 57: 17-22, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38948502

RESUMO

Introduction: Short stem prostheses were originally designed for younger and more active patients. In recent years, they have been increasingly offered to older patients. This study evaluates the mid-to long-term survival of a short stem prosthesis and the changes in periprosthetic bone density following implantation of a cementless short hip stem in patients over 60 years of age. Methods: 118 patients aged over 60 received short stem prostheses. Clinical examination included Harris Hip Score (HHS) and Hip Disability and Osteoarthritis Outcome Score (HOOS). 93 patients were followed clinically for at least five years. 53 patients underwent dual-energy x-ray absorptiometry (DXA) and radiographic evaluation. Follow-up intervals were preoperative and postoperative (t0), at approximately six months (t1), at approximately two years (t2), and at approximately five years or later (t3). Results: Over a mean 6.7-year observation period for all 118 patients, one stem revision occurred due to a traumatic periprosthetic stem fracture. The five-year survival rate for the endpoint survival of the Metha® stem in 95 at-risk patients is 99.2%. HHS improved significantly from t0 55.3 ± 11.5 (range 30-79) to t3 95.3 ± 8.6 (range 57-100) at a mean of 8.0 years (p < 0.001). HOOS improved significantly in each subscale (p < 0.001). Bone mineral density (BMD) was available for review in 53 patients after a mean of 7.1 years. BMD increased from t0 to t3 in region of interest (ROI) 3 (+0.4%) and ROI 6 (+2.9%) and decreased in ROI 1 (-10.3%), ROI 2 (-9.8%), ROI 4 (-5.3%), ROI 5 (-3.4%) and ROI 7 (-23.1%). Conclusions: The evaluated short stem prosthesis shows a remarkably high survival rate in elderly patients, accompanied by excellent clinical results. Load transfer measurements show a metaphyseal-diaphyseal pattern with a trend towards increased diaphyseal transfer over the period observed.

15.
Int Orthop ; 37(2): 327-35, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22976592

RESUMO

PURPOSE: Based on the revival of artificial ligaments containing polyethylene terephthalate, this study aimed to evaluate objective intra-articular findings within scheduled second-look arthroscopy, patient-reported clinical outcome and stability after isolated augmented ACL reconstruction with polyethylene terephthalate (Trevira®) augmented patella-bone-tendon-bone graft. METHODS: In a retrospective analysis of our institutional database, we found 126 patients with polyethylene terephthalate (Trevira®) augmented ACL reconstruction. All these patients underwent standardised second-look arthroscopic evaluation when removal of the augmentation became necessary. These second-look arthroscopic analyses focused on graft integration and remodelling in line with the polyethylene terephthalate augmentation. Arthroscopic re-examination comprised a graft evaluation including a structural and functional classification according to the Marburger Arthroscopy Score (MAS). Additional clinical evaluation was performed via the IKDC score and the scores of Tegner and Lysholm. Instrumental anterior laxity testing was carried out with a KT-1000™ arthrometer. Furthermore, a correlation analysis between the clinical parameters, the instrumental stability assessment and the corresponding arthroscopic graft condition was performed. RESULTS: The arthroscopic evaluation showed rupture of 87 (69 %) of 126 augmentation devices. In 27 (31 %) of these 87 cases, synovial reactions were found particularly in the anterior compartment. An intact synthetic augmentation with signs of graft integration with intact synovial coating was only found in 30 %. Evaluation according to the MAS showed good to excellent structural and functional characteristics in 88 % of patients. Presence of a type III graft (MAS) was found in an additional 11 %. A rudimentary (type IV) graft was only detected once. Eighty-five percent of patients were graded A or B according to IKDC score. The Lysholm score was 92.4 ± 4.8. Correlation analysis demonstrated a significant relationship between clinical outcome according to the IKDC score (p<0.05), instrumental stability performance according to the KT-1000™ assessment (p<0.05) and the corresponding arthroscopic graft evaluation according to the MAS. CONCLUSION: Graft integration and remodelling has complex and multi-factorial origins, particularly with artificial augmentation. Correlation analysis showed a significant relation between clinical condition, instrumental stability performance and arthroscopic graft constitution. The release of polyethylene terephthalate fibres caused inflammation of synovial tissue of the knee. Characteristic sub-clinical graft changes of structural, morphological and functional qualities of the inserted graft appear on second-look arthroscopy despite good clinical results.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Materiais Biocompatíveis/efeitos adversos , Polietilenotereftalatos/efeitos adversos , Adulto , Artroscopia , Enxerto Osso-Tendão Patelar-Osso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Cirurgia de Second-Look
16.
Int Orthop ; 37(2): 271-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22941098

RESUMO

PURPOSE: The aim of this study was to evaluate patient-reported clinical outcome, instrumental stability and prevalence of radiological osteoarthritis (OA) based on a homogeneous patient sample after two years and on average ten years after isolated anterior cruciate ligament (ACL) reconstruction. METHODS: Primarily we performed ACL reconstruction using a four-strand semitendinosus tendon (ST) autograft in 112 patients. Two years after reconstruction 98 patients could be re-evaluated. Long-term clinical and functional follow-up assessment was then performed on 52 patients on average 10.2 years after operative treatment. Inclusion criteria consisted of an isolated ACL rupture, reconstruction with ST graft and no associated cartilage alterations and meniscal lesions. Clinical and functional follow-up assessment included the International Knee Documentation Committee (IKDC) score and the scores of Tegner and Lysholm. Instrumental stability testing was carried out with the KT1000™ arthrometer. The degree of degenerative changes and prevalence of OA was based on the Jäger-Wirth score. RESULTS: The mean long-term follow-up was 10.2 years (eight-13 years), and the mean age was 40.4 years (24-62 years). About 72 % of patients were graded A or B according to the IKDC score. Activity levels according to the scores of Tegner and Lysholm were 4.8 and 88.2 on long-term follow-up. Radiological assessment revealed degenerative changes in the sense of a grade I OA in 21.2 % of patients. Prevalence of a grade II OA was found in 53.8 % of patients. A grade III OA and a grade IV OA were found in 19.2 and 5.7 %. Correlation analysis showed significant relationships between the long-term stability and prevalence of OA (p<0.05). CONCLUSIONS: Arthroscopic ACL reconstruction using four-strand ST autograft resulted in high patient satisfaction and good clinical results at two years and long-term follow-up. The prevalence of higher degree OA that developed in about 25 % of patients is significantly correlated with long-term knee joint stability.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Ligamento Cruzado Anterior/cirurgia , Traumatismos do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Tendões/transplante , Adulto , Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/epidemiologia , Osteoartrite do Joelho/etiologia , Prevalência , Radiografia , Resultado do Tratamento , Adulto Jovem
17.
J Orthop ; 46: 117-123, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37994362

RESUMO

Introduction: In order to improve the anchorage behavior of short hip stems, this development project aims at designing a short hip stem concept that preserves the femoral neck and minimizes interference with the physiological stress distribution of the femur. The new design will be evaluated according to ISO 7206-4 which is the standard for testing Implants for surgery. Methods: Basic CAD models based on an established short stem prosthesis were created and evaluated using finite element analysis. The best design was further developed to achieve a more deformable stem while maintaining stability. The model was validated through in vitro testing. Results: The "H-Beam" short stem showed a higher degree of deformation of approximately 142-144% compared to the established short stem. The FE model had a relative error of 0.98% and 1.07% compared to the in vitro tests. An operating procedure was outlined for this new short stem design. Discussion: The FE model is deemed valid due to small differences in comparison to in vitro testing. The short-stem prosthesis is more flexible and can be easily adapted to individual anatomy during surgery. The prosthesis length is similar to conventional prostheses, but the new stem design could allow better and faster osteointegration while preserving the cancellous bone structure.

18.
Med Eng Phys ; 111: 103932, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36792236

RESUMO

Aseptic loosening is a frequent cause for revision of endoprosthesis. X-ray examinations like Radio-Stereometry-Analysis (RSA) are among the most widely used in vivo methods for its detection. Nevertheless, this method is not used routinely because of bone marker and related radiation exposure. This work aims at creating a new in vivo concept to detect implant stability measuring micromotions without x-ray and to develop a corresponding algorithm. Based on the assumption of contactless measurement, the input parameters for the algorithm are the distances of each ultrasound sensor to the object (prosthesis and bone) and its position. First, the number of parameters necessary for a precise reconstruction and measurement of micromotions between objects had to be defined. Therefore, the algorithm has been tested with simulations of these parameters. Two experimental measurements, either using contact sensors or ultrasound, were used to prove the accuracy of the algorithm. Simulations indicate a high accuracy with three distances as initial parameters for each object. Contact measurements show precise representation of micromotion, and the contactless measurements show the possibility of detecting various materials with a high resolution. This work lays the foundations for non-invasive detection of micromotions between the implant-bone interface.


Assuntos
Prótese de Quadril , Desenho de Prótese , Osso e Ossos
19.
Clin Biomech (Bristol, Avon) ; 109: 106079, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37651899

RESUMO

BACKGROUND: Preparing the medullary space of the femur aims to create an ideal form-fitting of cementless implants to provide sufficient initial stability, which is crucial for osseous integration, ensuring good long-term results. Hammering the implant into the proximal femur creates a press-fit anchoring of the endoprosthesis in the medullary space. Implanting the optimal size of the shaft for best fitting should avoid damage to the bone. Modified acoustic signals in connection with implantation are being detected by surgeons and might be related to the primary stability of the implant. METHODS: This study aims to explore the relationship between frequency sound patterns and the change in stem stability. For this purpose, n = 32 Metha® short stems were implanted in a clinical setting by the same surgeon. During implantation, the sounds were recorded. To define a change in the acoustic system response during the operation, the individual blows of the implantation sequence were correlated with one another. FINDINGS: An algorithm was able to subdivide through sound analysis two groups of hammer blows (area 1 and area 2) since the characteristics of these groups showed significant differences within the frequency range of 100 Hz to 24 kHz. The edge between both groups, detected by the algorithm, was validated with expert surgeons' classifications of the same data. INTERPRETATION: In conclusion, monitoring, the hammer blows sound might allow quantification of the primary stability of the implant. Sound analysis including patient parameters and a classification algorithm could provide a precise characterization of implant stability.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Desenho de Prótese , Fêmur/cirurgia , Acústica
20.
Int Orthop ; 36(1): 171-7, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21898038

RESUMO

PURPOSE: The aim of this investigation was to study patient-reported long-term clinical outcome, instrumental stablitity and prevalence of radiological osteoarthritis (OA) a minimum of ten years after isolated anterior cruciate ligament (ACL) reconstruction. METHODS: An average of 13.5 years after ACL reconstruction with bone-patellar tendon-bone (BTB) autograft, 73 patients were evaluated. Inclusion criteria consisted of an isolated ACL rupture and reconstruction with BPTB graft with no associated intra-articular lesions, in particular, cartilage alterations or meniscal lesions. Clinical assessment was performed using the International Knee Documentation Committee (IKDC) and Tegner and Lysholm scores. Instrumental anterior laxity testing was carried out with the KT-1000™ arthrometer. Degree of degenerative changes and prevalence of OA were determined using the Kellgren- Lawrence scale. RESULTS: Mean follow-up was 13.5 years. Mean age was 43.8 years. About 75% of patients were graded A or B according to the IKDC score. The Lysholm score was 90.2 ± 4.8. Radiological assessment reported degenerative changes of grade II OA in 54.2% of patients. Prevalence of grades III or IV OA was found in 20%. The incidence of OA was significantly correlated with stability and function at long-term follow-up. CONCLUSION: Arthroscopic ACL reconstruction using BPTB autograft resulted in a high degree of patient satisfaction and good clinical results on long-term follow-up. A higher degree of OA developed in 20% of patients and was significantly correlated with increased anterior laxity at long-term follow-up.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Enxerto Osso-Tendão Patelar-Osso/efeitos adversos , Instabilidade Articular/complicações , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Adulto , Lesões do Ligamento Cruzado Anterior , Feminino , Seguimentos , Humanos , Instabilidade Articular/fisiopatologia , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Satisfação do Paciente , Complicações Pós-Operatórias , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Ruptura , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA