Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 51(7): 1443-57, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23435152

RESUMO

BACKGROUND: The 2009 Asian multicenter study for derivation of reference intervals (RIs) featured: 1) centralized measurements to exclude reagent-dependent variations; 2) inclusion of non-standardized analytes (hormones, tumor makers, etc.) in the target; and 3) cross-check of test results between the central and local laboratories. Transferability of centrally derived RIs for non-standardized analytes based on the cross-check was examined. METHODS: Forty non-standardized analytes were centrally measured in sera from 3541 reference individuals recruited by 63 laboratories. Forty-four laboratories collaborated in the cross-check study by locally measuring aliquots of sera from 9 to 73 volunteers (average 22.2). Linear relationships were obtained by the major-axis regression. Error in converting RIs using the regression line was expressed by the coefficient of variation of slope b [CV(b)]. CV(b) <10% was set as the cut-off value allowing the conversion. The significance of factors for partitioning RIs was determined similarly as in the first report. RESULTS: Significant sex-, age-, and region-related changes in test results were observed in 17, 15, and 11 of the 40 analytes, respectively. In the cross-comparison study, test results were not harmonized in the majority of immunologically measured analytes, but their average CV(b)s were <10% except for total protein, cystatin C, CA19-9, free thyroxine, and triiodothyronine. After conversion, 74% of centrally derived RIs were transferred to each local laboratory. CONCLUSIONS: Our results point to the feasibility of: 1) harmonizing test results across different laboratories; and 2) sharing centrally derived RIs of non-standardized analytes by means of comparative measurement of a set of commutable specimens.


Assuntos
Biomarcadores Tumorais/sangue , Proteínas Sanguíneas/análise , Cistatina C/sangue , Lipoproteínas/sangue , Hormônios Tireóideos/sangue , Adulto , Fatores Etários , Idoso , Análise de Variância , Povo Asiático , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores Sexuais
2.
J Agric Food Chem ; 50(1): 172-6, 2002 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-11754563

RESUMO

Phytate-removed deamidated soybean globulins were prepared using ion-exchange resins to provide them with a functional property to enhance calcium absorption in the body. The phosphorus level was reduced from 45 to 20 micromol/g using 0.05 g/mL of AE-4, an anion-exchange resin with a (2-hydroxyethyl)dimethylammonium group, in 0.2% soybean globulin solution for 1 h at 4 degrees C, and 90-92% of the phosphorus in defatted soybeans could be removed. As for deamidation, CE-4, a cation-exchange resin of the carboxylate type, showed a much higher deamidation activity than CE-1 and CE-2, cation-exchange resins of the sulfonate type. No peptide bond hydrolysis was observed for any cation-exchange resin treated at 4 degrees C. There was no significant difference in the amount of acid amide deamidated at temperatures between 4 and 50 degrees C. The deamidation level was able to increase to 73% using 0.10 g/mL of CE-4 in a 0.2% soybean globulin solution for 6 h at 4 degrees C. The amount of calcium bound to the soybean globulins decreased with removal of the phytate but increased with deamidation.


Assuntos
Cálcio/metabolismo , Globulinas/metabolismo , Glycine max/química , Resinas de Troca Iônica/química , Ácido Fítico/metabolismo , Disponibilidade Biológica , Cálcio/farmacocinética , Desaminação , Globulinas/química , Humanos , Absorção Intestinal/efeitos dos fármacos , Fósforo/análise , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA