Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
BMC Med Inform Decis Mak ; 22(1): 248, 2022 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-36138408

RESUMO

BACKGROUND: Point of care testing (POCT) devices have been developed to facilitate immediate results with the potential to aid screening for new disease and enable patients to self-monitor their disease. Non-communicable diseases (NCDs) are the major cause of mortality globally and are increasing in prevalence as the population ages. Allied health care professionals (AHPs) are skilled in undertaking risk assessment and delivering preventative advice, providing opportunities to access large proportions of the population who may not visit their doctor, within non-traditional community settings. There is evidence of high levels of support from public, patients and health professionals for engaging AHPs in risk-targeted early case detection of certain NCDs. Thus, POCT devices offer a potential alternative to traditional venous blood collection, as novel care pathways for increasing early case detection and access to preventative care. The objectives of this study were to: (i) determine the concordance of the specific POCT devices with laboratory-based standard assays employed within clinical biochemistry laboratories. (ii) compare the sampling experience of both methods via patient-reported experiences. METHODS: A prospective, two-centre study was undertaken involving 158 participants who provided informed consent. Venous blood was collected for traditional assays of HbA1c, creatinine/ estimated Glomerular-Filtration-Rate (eGFR) and vitamin-D. Capillary blood was collected by finger prick test and also assayed for the same biochemical indices (Nova StatSensor (creatinine/eGFR); Siemens DCA-Vantage (HbA1C); CityAssays (vitamin-D)). All users were provided with device training. Participants reported any discomfort experienced by each simultaneously applied method (randomised in order) via a 100 mm Visual-Analogue-Scale. RESULTS: Results for each POCT device and the laboratory standard were analysed by Bland-Altman plots to determine assay concordance. POCT devices demonstrated good concordance with laboratory testing, with at least 95% of all samples being within two standard deviations, for each of the devices tested. The majority of participants reported less discomfort with POCT than venepuncture, with the average reported discomfort being 17/100 mm less for POCT compared to venous blood sample collection on the visual analogue scale. CONCLUSIONS: The POCT devices demonstrated acceptable concordance with laboratory-based assays, and patients reported lower levels of discomfort compared to traditional means of blood collection. This study demonstrates the potential of using these devices as acceptable methods for opportunistic testing of "at-risk" individuals within non-traditional community care settings.


Assuntos
Química Clínica , Sistemas Automatizados de Assistência Junto ao Leito , Creatinina , Hemoglobinas Glicadas/metabolismo , Humanos , Laboratórios , Medidas de Resultados Relatados pelo Paciente , Testes Imediatos , Estudos Prospectivos , Vitaminas
2.
J Comput Chem ; 41(4): 317-327, 2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-31713259

RESUMO

We have computationally studied the bimolecular nucleophilic substitution (SN 2) reactions of Mn NH2 (n-1) + CH3 Cl (M+ = Li+ , Na+ , K+ , and MgCl+ ; n = 0, 1) in the gas phase and in tetrahydrofuran solution at OLYP/6-31++G(d,p) using polarizable continuum model implicit solvation. We wish to explore and understand the effect of the metal counterion M+ and of solvation on the reaction profile and the stereochemical preference, that is, backside (SN 2-b) versus frontside attack (SN 2-f). The results were compared to the corresponding ion-pair SN 2 reactions involving F- and OH- nucleophiles. Our analyses with an extended activation strain model of chemical reactivity uncover and explain various trends in SN 2 reactivity along the nucleophiles F- , OH- , and NH 2 - , including solvent and counterion effects. © 2019 Wiley Periodicals, Inc.

3.
J Comput Chem ; 40(3): 619-624, 2019 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-30144127

RESUMO

The distortion/interaction-activation strain model (D/I-ASM), a fragment analysis method, is applied to study the structure-reactivity relationship in reactions. The application of D/I-ASM involves the generation of input files for points along a reaction profile, submission of input files to a quantum software package, processing of parameters from the resulting output files and generation of graphical plots. The ExcelAutomat tool (Laloo et al., J. Comput. Aided Mol. Des. 2017, 31, 667) provides a framework and library in Visual Basic for Application programming language to process such files. New routines were written in ExcelAutomat 1.3 to facilitate processing of files for D/I-ASM. The worksheet "ASM" was included where initial parameters needed can be defined. The routines for D/I-ASM were tested successfully on bimolecular nucleophilic substitution, cycloaddition, and barrierless reactions. The automation of fragment analysis by ExcelAutomat 1.3 is compatible with Microsoft Excel and LibreOffice Calc. The extensible tool processes files from Gaussian and GAMESS-US packages. © 2018 Wiley Periodicals, Inc.

4.
J Comput Aided Mol Des ; 31(7): 667-673, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28624971

RESUMO

The processing of the input and output files of quantum chemical calculations often necessitates a spreadsheet as a key component of the workflow. Spreadsheet packages with a built-in programming language editor can automate the steps involved and thus provide a direct link between processing files and the spreadsheet. This helps to reduce user-interventions as well as the need to switch between different programs to carry out each step. The ExcelAutomat tool is the implementation of this method in Microsoft Excel (MS Excel) using the default Visual Basic for Application (VBA) programming language. The code in ExcelAutomat was adapted to work with the platform-independent open-source LibreOffice Calc, which also supports VBA. ExcelAutomat provides an interface through the spreadsheet to automate repetitive tasks such as merging input files, splitting, parsing and compiling data from output files, and generation of unique filenames. Selected extracted parameters can be retrieved as variables which can be included in custom codes for a tailored approach. ExcelAutomat works with Gaussian files and is adapted for use with other computational packages including the non-commercial GAMESS. ExcelAutomat is available as a downloadable MS Excel workbook or as a LibreOffice workbook.


Assuntos
Software , Gráficos por Computador , Teoria Quântica , Interface Usuário-Computador , Fluxo de Trabalho
5.
Chemistry ; 22(13): 4431-9, 2016 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-26879231

RESUMO

The ion-pair SN 2 reactions of model systems MnF(n-1) +CH3Cl(M(+) =Li(+), Na(+), K(+), and MgCl(+); n=0, 1) have been quantum chemically explored by using DFT at the OLYP/6-31++G(d,p) level. The purpose of this study is threefold: 1) to elucidate how the counterion M(+) modifies ion-pair SN 2 reactivity relative to the parent reaction F(-) +CH3Cl; 2) to determine how this influences stereochemical competition between the backside and frontside attacks; and 3) to examine the effect of solvation on these ion-pair SN2 pathways. Trends in reactivity are analyzed and explained by using the activation strain model (ASM) of chemical reactivity. The ASM has been extended to treat reactivity in solution. These findings contribute to a more rational design of tailor-made substitution reactions.

7.
Chem Asian J ; 13(9): 1138-1147, 2018 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-29437289

RESUMO

We have theoretically studied the non-identity SN 2 reactions of Mn OH(n-1) +CH3 Cl (M+ =Li+ , Na+ , K+ , and MgCl+ ; n=0, 1) in the gas phase and in THF solution at the OLYP/6-31++G(d,p) level using polarizable continuum model (PCM) implicit solvation. We want to explore and understand the effect of the metal counterion M+ and solvation on the reaction profile and the stereoselectivity of these processes. To this end, we have explored the potential energy surfaces of the backside (SN 2-b) and frontside (SN 2-f) pathways. To explain the computed trends, we have carried out analyses with an extended activation strain model (ASM) of chemical reactivity that includes the treatment of solvation effects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA