Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 80(4): 546-53, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22121027

RESUMO

OBJECTIVES: The SPIRIT Small Vessel (SV) was designed to evaluate the safety and effectiveness of the 2.25-mm XIENCE V everolimus eluting coronary stent system (EECSS), known as the XIENCE nano EECSS, in subjects with SVs and ischemic heart disease. BACKGROUND: The core sizes of XIENCE V EECSS are associated with low rates of restenosis and thrombosis in the general population, but the XIENCE nano EECSS has not been tested in the United States. METHODS: This prospective, single-arm, open-label study was conducted at 33 centers and in 150 patients in the United States. The primary endpoint was the target lesion failure (TLF) rate at 1 year, required to meet the prespecified performance goal (PG) of 20.4%, derived from historical data. RESULTS: The mean patient age was 63 years, 38% were women, 39.2% were diabetic, 49.3% had multivessel disease, and the reference vessel diameter was 2.13 ± 0.23 mm. The 1-year TLF rate was 8.1% in with an upper limit of the one-sided 95% confidence interval of 13.0%, which met the PG of 20.4% (P < 0.0001). At 1 year, the rate of cardiac death was 1.5%, the target vessel myocardial infarction rate was 1.5%, and clinically indicated target lesion revascularization rate was 5.1%. The 8-month angiographic in-stent late loss was 0.2 ± 0.4 mm, respectively. The 1-year academic research consortium defined definite/probable stent thrombosis rate was 1.5%. CONCLUSIONS: Based on the 1-year clinical and 8-month angiographic SPIRIT SV data, the XIENCE nano EECSS is considered safe and effective in the treatment of SVs.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Nanomedicina , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Everolimo , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA