Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Soft Matter ; 13(44): 8331-8336, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-29058731

RESUMO

Dynamic wetting behaviors on soft solids are important to interpret complex biological processes from cell-substrate interactions. Despite intensive research studies over the past half-century, the underlying mechanisms of spreading behaviors are not clearly understood. The most interesting feature of wetting on soft matter is the formation of a "wetting ridge", a surface deformation by a competition between elasticity and capillarity. Dynamics of the wetting ridge formed at the three-phase contact line underlies the dynamic wetting behaviors, but remains largely unexplored mostly due to limitations in indirect observation. Here, we directly visualize wetting ridge dynamics during continuous- and stick-slip motions on a viscoelastic surface using X-ray microscopy. Strikingly, we discover that the ridge spreads spontaneously during stick and triggers contact line depinning (stick-to-slip transition) by changing the ridge geometry which weakens the contact line pinning. Finally, we clarify 'viscoelastic-braking', 'stick-slipping', and 'stick-breaking' spreading behaviors through the ridge dynamics. In stick-breaking, no ridge-spreading occurs and contact line pinning (hysteresis) is enhanced by cusp-bending while preserving a microscopic equilibrium at the ridge tip. We have furthered the understanding of spreading behaviors on soft solids and demonstrated the value of X-ray microscopy in elucidating various dynamic wetting behaviors on soft solids as well as puzzling biological issues.

2.
J Synchrotron Radiat ; 22(6): 1524-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26524317

RESUMO

X-ray irradiation is shown to trigger the deposition of Cu from solution, at room temperature, on a wide variety of insulating substrates: glass, passivated Si, TiN/Ti/SiO2/Si and photoresists like PMMA and SU-8. The process is suitable for patterning and the products can be used as seeds for electroplating of thicker overlayers.

3.
Scand J Immunol ; 78(3): 238-47, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23679814

RESUMO

Reactive oxygen species (ROS) are produced by dendritic cells (DCs) during antigen presentation in contact hypersensitivity (CHS). ROS cause a number of non-enzymatic protein modifications, such as carbonylation. Carbonylated proteins in DCs in response to hapten have not been fully identified yet. To identify the proteins carbonylated by ROS, murine epidermis-derived DC line XS106 was challenged with a hapten, 2,4,6-trinitrobenzene sulphonic acid (TNBS). MALDI-TOF analysis revealed that heat-shock protein 70 (HSP70) was one of the carbonylated proteins induced by TNBS. To verify the role of HSP70 in TNBS-treated XS106 cell, we fused protein transduction domain (PTD) with HSP70 to facilitate protein delivery into the cell. The transfected fusion protein HSP70 within the cell caused transient increase of the cellular level of HSP70. Transient increase of HSP70 level in XS-106 DCs resulted in inhibition of ROS production, carbonylation of HSP70, p38 MAPK activation and subsequently IL-12 secretion. To investigate the effects of PTD-HSP70 in vivo, ear-swelling experiments with 2,4,6-trinitro-1-chlorobenzene (TNCB) were performed in BALB/c mice. Pretreatment of PTD-HSP70 reduced the CHS response to TNCB in vivo. We report here that carbonylation of HSP70 by ROS is associated with the pathogenesis of CHS, suggesting possibility of HSP70-targeting therapy in CHS.


Assuntos
Células Dendríticas/imunologia , Células Dendríticas/metabolismo , Proteínas de Choque Térmico HSP70/metabolismo , Carbonilação Proteica , Espécies Reativas de Oxigênio/metabolismo , Animais , Linhagem Celular , Dermatite de Contato/imunologia , Dermatite de Contato/metabolismo , Ativação Enzimática , Haptenos/imunologia , Interleucina-12/metabolismo , Camundongos , Camundongos Endogâmicos A , Camundongos Endogâmicos BALB C , Cloreto de Picrila/química , Proteínas Recombinantes de Fusão/metabolismo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Transfecção , Ácido Trinitrobenzenossulfônico/imunologia , Proteínas Quinases p38 Ativadas por Mitógeno/metabolismo
4.
Phys Rev Lett ; 107(1): 018301, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21797577

RESUMO

We show direct evidence that focused x rays enable us to merge polymer colloidal particles at room temperature. This phenomenon is ascribed to the photochemical scission of colloids with x rays, reducing the molecular weight, glass transition temperature, surface tension, and viscosity of colloids. The observation of the neck bridge growth with time shows that the x-ray-induced colloid coalescence is analogous to viscoelastic coalescence. This finding suggests a feasible protocol of photonic nanofabrication by sintering or welding of polymers, without thermal damage, using x-ray photonics.

5.
Anal Bioanal Chem ; 401(3): 827-35, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21626185

RESUMO

Refractive-index (phase-contrast) radiology was able to detect lung tumors less than 1 mm in live mice. Significant micromorphology differences were observed in the microradiographs between normal, inflamed, and lung cancer tissues. This was made possible by the high phase contrast and by the fast image taking that reduces the motion blur. The detection of cancer and inflammation areas by phase contrast microradiology and microtomography was validated by bioluminescence and histopathological analysis. The smallest tumor detected is less than 1 mm(3) with accuracy better than 1 × 10(-3) mm(3). This level of performance is currently suitable for animal studies, while further developments are required for clinical application.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Animais , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Linhagem Celular Tumoral , Colágeno/química , Modelos Animais de Doenças , Glioma/diagnóstico por imagem , Glioma/patologia , Neoplasias Pulmonares/patologia , Masculino , Camundongos , Radiografia , Ratos , Padrões de Referência , Espectroscopia de Infravermelho com Transformada de Fourier
6.
J Synchrotron Radiat ; 17(6): 817-20, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20975231

RESUMO

Synchrotron phase-contrast hard X-ray imaging is used to provide highly efficient direct visualization of landslide dynamics and granular flows in fully wet granular piles. High penetration capability and phase-contrast enhancement of hard X-rays offer marked advantages in the precise tracking of individual granular movements through a thick water medium. It is revealed that the stress accumulation follows a power-law evolution while the relaxation follows an exponential one. The onset of landslide emerges at the trade-off of the two evolutions.

7.
Aliment Pharmacol Ther ; 45(12): 1493-1505, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28436552

RESUMO

BACKGROUND: Preventing mother to child transmission of chronic hepatitis B infection in the setting of a high maternal viral load is challenging. The idea has emerged from antepartum tenofovir treatment with combination immunoprophylaxis. AIMS: To demonstrate the efficacy and safety of tenofovir to prevent mother to child transmission of hepatitis B virus. METHODS: PubMed, EMBASE, and Cochrane databases were searched through August 16, 2016. Comparative trials of second or third trimester tenofovir administration vs. controls for patients with chronic hepatitis B infection and non-comparative case series assessing mother to child transmission rates and evaluating maternal and foetal safety outcomes were included. RESULTS: Ten studies (one randomised controlled trial, four non-randomised controlled trials and five case series) that enrolled 733 women were included. The pooled results from comparative trials (599 pregnancies) showed that tenofovir significantly reduced the risk of infant hepatitis B surface antigen seropositivity by 77% (odds ratio=0.23, 95% confidence intervals=0.10-0.52, P=.0004) without heterogeneity (I2 =0%). In the case series analysis (134 pregnancies), only two cases (1.5%) of mother to child transmission with extremely high maternal viral load and non-compliance to treatment were identified. Maternal and foetal safety parameters including congenital malformation and foetal death were re-assuring. CONCLUSIONS: For pregnant women with high hepatitis B virus DNA levels, tenofovir administration in the second or third trimester can prevent mother to child transmission when combined with hepatitis B immunoglobulin and the hepatitis B vaccine. Tenofovir is safe and tolerable for both the mother and foetus.


Assuntos
Hepatite B Crônica/tratamento farmacológico , Hepatite B Crônica/transmissão , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Complicações Infecciosas na Gravidez/tratamento farmacológico , Tenofovir/uso terapêutico , Terapia Combinada , Feminino , Vacinas contra Hepatite B/uso terapêutico , Vírus da Hepatite B/efeitos dos fármacos , Vírus da Hepatite B/genética , Vírus da Hepatite B/imunologia , Hepatite B Crônica/epidemiologia , Hepatite B Crônica/terapia , Humanos , Lactente , Transmissão Vertical de Doenças Infecciosas/estatística & dados numéricos , Mães/estatística & dados numéricos , Gravidez , Complicações Infecciosas na Gravidez/epidemiologia , Complicações Infecciosas na Gravidez/terapia , Tenofovir/efeitos adversos , Resultado do Tratamento , Carga Viral/efeitos dos fármacos , Carga Viral/genética
8.
Free Radic Biol Med ; 37(4): 539-48, 2004 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-15256225

RESUMO

Lipid peroxidation and its end-product, 4-hydroxyhexenal (HHE), are known to affect redox balance during aging, which causes various degenerative processes including vascular alterations from endothelial cell deterioration. To better understand the molecular action of HHE in the development of vascular abnormalities during the aging process, we investigated whether the upregulation of inducible endothelial nitric oxide synthase (iNOS) by HHE is mediated through nuclear factor kappaB (NF-kappaB) activation. Results indicate that HHE stimulates iNOS by the transcriptional regulation of NF-kappaB activation through cytosolic kappaB degradation inhibitors (IkappaB). Pretreatment with NF-kappaB inhibitors Bay 11-7082 and N-acetyl cysteine (NAC) suppressed the upregulation of iNOS by blunting IkappaB degradation and NF-kappaB binding activity. Because inflammatory stimuli induce iNOS to generate large amounts of nitric oxide (NO), intracellular NO levels in the presence of Bay 11-7082, NAC, and caffeic acid methyl ester were estimated. These inhibitors significantly suppressed the HHE-induced NO levels to a basal level. These findings strongly suggest that in endothelial cells, HHE induces iNOS gene expression through NF-kappaB activation, which can lead to vascular dysfunction by the activation of various proinflammatory genes.


Assuntos
Aldeídos/química , NF-kappa B/metabolismo , Óxido Nítrico Sintase/metabolismo , Acetilcisteína/farmacologia , Envelhecimento , Animais , Apoptose , Western Blotting , Núcleo Celular/metabolismo , Sobrevivência Celular , Corantes/farmacologia , Meios de Cultura Livres de Soro/farmacologia , Citosol/metabolismo , Relação Dose-Resposta a Droga , Ativação Enzimática , Radicais Livres , Regulação da Expressão Gênica , Peroxidação de Lipídeos , Luciferases/metabolismo , Masculino , Óxido Nítrico/metabolismo , Óxido Nítrico Sintase Tipo II , Nitrilas/farmacologia , Oxirredução , Estresse Oxidativo , Próstata/patologia , Ratos , Sulfonas/farmacologia , Sais de Tetrazólio/farmacologia , Tiazóis/farmacologia , Fatores de Tempo , Transcrição Gênica , Transfecção , Regulação para Cima
9.
Phys Med Biol ; 49(4): 501-8, 2004 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-15005160

RESUMO

Coherent x-rays from synchrotron sources are increasingly used in non-conventional radiological techniques ('phase-contrast' radiology). Our experiments demonstrate that by using white (unmonochromatic) radiation and a time-resolving system, it is possible to image microscopic details of moving blood vessels in different live animals without using any contrast agent. The images have excellent contrast plus unprecedented spatial resolution for microangiography (< 10 microm). This result is likely to impact many different areas of biological and medical research and of diagnostic radiology.


Assuntos
Olho/diagnóstico por imagem , Síncrotrons , Tarso Animal/diagnóstico por imagem , Angiografia , Animais , Meios de Contraste , Olho/irrigação sanguínea , Camundongos , Ratos , Tarso Animal/irrigação sanguínea , Tomografia Computadorizada por Raios X/métodos
10.
J Nanosci Nanotechnol ; 1(3): 271-3, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12914061

RESUMO

The effects of long-range and short-range orders of Ti underlayer thickness on the magnetic properties of sputtered Co72 Cr21 Pt7 films were investigated using synchrotron X-ray scattering and X-ray absorption near-edge structure spectroscopy. The results were consistent with that of magnetic measurements and X-ray photoelectron spectroscopy. For thin Ti underlayers (10 nm), the oxidation of Ti and significant mixing of other elements within this underlayer did not promote texture development, further resulting in poor texturing of magnetic films and undesirable magnetic properties. Increased crystallinity and texture of metallic Ti in thicker underlayers enhanced the magnetic peak alignment and its properties.


Assuntos
Ligas de Cromo/química , Cristalização/métodos , Chumbo/química , Magnetismo , Nanotecnologia/métodos , Titânio/química , Ligas de Cromo/isolamento & purificação , Cristalografia/métodos , Teste de Materiais/métodos , Membranas Artificiais , Conformação Molecular , Relação Estrutura-Atividade
11.
Biotechnol Adv ; 31(3): 375-86, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22546483

RESUMO

Our experimental results demonstrate that full-field hard-X-ray microscopy is finally able to investigate the internal structure of cells in tissues. This result was made possible by three main factors: the use of a coherent (synchrotron) source of X-rays, the exploitation of contrast mechanisms based on the real part of the refractive index and the magnification provided by high-resolution Fresnel zone-plate objectives. We specifically obtained high-quality microradiographs of human and mouse cells with 29 nm Rayleigh spatial resolution and verified that tomographic reconstruction could be implemented with a final resolution level suitable for subcellular features. We also demonstrated that a phase retrieval method based on a wave propagation algorithm could yield good subcellular images starting from a series of defocused microradiographs. The concluding discussion compares cellular and subcellular hard-X-ray microradiology with other techniques and evaluates its potential impact on biomedical research.


Assuntos
Estruturas Celulares/citologia , Processamento de Imagem Assistida por Computador/métodos , Microrradiografia/métodos , Microscopia/métodos , Algoritmos , Animais , Aorta/citologia , Desenho de Equipamento , Ouro , Células HeLa , Humanos , Nanopartículas Metálicas/análise , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Microrradiografia/instrumentação , Microscopia/instrumentação , Neoplasias Experimentais/patologia , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Raios X , Peixe-Zebra
12.
Rev Sci Instrum ; 83(9): 093704, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23020380

RESUMO

A fast microtomography system for high-resolution high-speed imaging has been developed using bright monochromatic x-rays at the BL29XU beamline of SPring-8. The shortest scan time for microtomography we attained was 0.25 s in 1.25 µm effective pixel size by combining the bright monochromatic x-rays, a fast rotating sample stage, and a high performance x-ray imaging detector. The feasibility of the tomography system was successfully demonstrated by visualization of rising bubbles in a viscous liquid, an interesting issue in multiphase flow physics. This system also provides a high spatial (a measurable feature size of 300 nm) or a very high temporal (9.8 µs) resolution in radiographs.


Assuntos
Microtecnologia/instrumentação , Tomografia por Raios X/instrumentação , Cor , Estudos de Viabilidade , Imageamento Tridimensional , Rotação , Fatores de Tempo
13.
Phys Rev E Stat Nonlin Soft Matter Phys ; 84(3 Pt 1): 032601, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22060436

RESUMO

We present quantitative evidence for x-ray-induced water vaporization: water is vaporized at a rate of 5.5 pL/s with the 1-Å-wavelength x-ray irradiation of ~0.1 photons per Å(2); moreover, water vapor is reversibly condensed during pauses in irradiation. This result fundamentally suggests that photoionization induces vaporization. This phenomenon is attributed to surface-tension reduction by ionization and would be universally important in radiological and electrohydrodynamic situations.

14.
Phys Rev Lett ; 100(21): 217403, 2008 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-18518633

RESUMO

We discovered that intense irradiation by hard-x-ray strongly decreases the effects of natural surface tension of water in droplets and capillary tubes. The effect was revealed by direct experimental observations with phase contrast microradiology. A model based on ionization and surface charging explains this so far undetected phenomenon. The effect can impact the results of many experimental techniques based on x rays. This is an example of the largely unexplored effects that can be produced by extreme intense x-ray irradiation-an important issue due to current development of x-ray free-electron-lasers with unprecedented brilliance.

15.
J Synchrotron Radiat ; 15(Pt 6): 660-2, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18955775

RESUMO

A quantitative application of microradiology with coherent X-rays to the real-time study of microbubble and microdroplet coalescence phenomena, with specific emphasis on the size relations in three-body events, is presented. The results illustrate the remarkable effectiveness of coherent X-ray imaging in delineating interfaces in multiphase systems, in accurately measuring their geometric properties and in monitoring their dynamics.


Assuntos
Algoritmos , Gases/química , Microfluídica/métodos , Soluções/química , Propriedades de Superfície , Síncrotrons , Tomografia de Coerência Óptica/métodos , Difração de Raios X/métodos
16.
J Synchrotron Radiat ; 15(Pt 1): 96-9, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18097084

RESUMO

The correlation between the microscopic lattice plane curvature and the dislocation structure in thermal warpage of 200 mm-diameter Czochralski Si (001) wafers has been investigated using high-resolution X-ray diffractometry and topography. It is found that the (004) lattice plane curvature is locally confined between two neighboring slip bands, with the rotation axis parallel to the slip bands. High-resolution topography reveals that the curvature resulted from a fragmented dislocation structure. The local confinement is attributed to the multiplication of the dislocations that are generated between the two slip bands.

17.
J Synchrotron Radiat ; 15(Pt 2): 170-5, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18296784

RESUMO

The fabrication of gold Fresnel zone plates, by a combination of e-beam lithography and electrodeposition, with a 30 nm outermost zone width and a 450 nm-thick structure is described. The e-beam lithography process was implemented with a careful evaluation of applied dosage, tests of different bake-out temperatures and durations for the photoresist, and the use of a developer without methylisobutylketone. Electrodeposition with a pulsed current mode and with a specially designed apparatus produced the desired high-aspect-ratio nanostructures. The fabricated zone plates were examined by electron microscopy and their performances were assessed using a transmission X-ray microscope. The results specifically demonstrated an image resolution of 40 nm.

18.
Nanotechnology ; 19(29): 295104, 2008 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-21730596

RESUMO

We explored a very interesting gold nanoparticle system-pegylated gold in colloidal solution-and analyzed its uptake by mice colorectal adenocarcinoma CT26 tumor cells and the impact on the cell's response to x-ray irradiation. We found that exposure to polyethylene glycol (PEG) modified ('pegylated') 4.7 ± 2.6 nm gold nanoparticles synthesized by a novel synchrotron-based method enhances the response of CT26 cells to x-ray irradiation. Transmission electron microscopy (TEM) and confocal microscopy revealed that substantial amounts of such nanoparticles are taken up and absorbed by the cells and this conclusion is supported by quantitative induced coupled plasma (ICP) results. Standard tests indicated that the internalized particles are highly biocompatible but strongly enhance the cell damage induced by x-ray irradiation. Synchrotron radiation Fourier transform infrared (SR-FTIR) spectromicroscopy analyzed the chemical aspects of this phenomenon: the appearance of C = O stretching bond spectral features could be used as a marker for cell damage and confirmed the enhancement of the radiation-induced toxicity for cells.

19.
Neuroimage ; 32(2): 566-9, 2006 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16766209

RESUMO

Parkinson's disease (PD), defined as a neurodegenerative disorder, is characterized by the loss of dopaminergic neurons and the presence of Lewy bodies in neurons. Morphological study of Lewy bodies is important to identify the causes and the processes of PD. Here, we investigate a possibility of phase contrast radiography using coherent synchrotron X-rays to explore the microscopic details of Lewy bodies in thick (approximately 3 mm) midbrain tissues. Autopsied midbrain tissues of a PD patient were sliced in 3 mm thickness and then examined using synchrotron X-rays from the 7B2 beamline of the Pohang Light Source. Refraction-enhanced phase contrast radiography and microtomography were adopted to identify dark core and dim edge of Lewy bodies in neurons. The morphology of Lewy bodies was clearly revealed by the phase contrast radiography in very thick (3 mm) midbrain tissues without any staining treatment. Three-dimensional volume rendered microtomography of the autopsied midbrain tissues demonstrates striking evidence that several Lewy bodies are agglomerated by dim edges in a neuron. We suggest that the phase contrast radiography could be a useful tool to morphologically investigate the causes or the processes in PD.


Assuntos
Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Corpos de Lewy/diagnóstico por imagem , Mesencéfalo/diagnóstico por imagem , Microscopia de Contraste de Fase/instrumentação , Doença de Parkinson/diagnóstico por imagem , Radiografia/instrumentação , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Dopamina/metabolismo , Desenho de Equipamento , Humanos , Corpos de Lewy/patologia , Masculino , Computação Matemática , Pessoa de Meia-Idade , Degeneração Neural/patologia , Doença de Parkinson/patologia , Fotografação/instrumentação , Sensibilidade e Especificidade , Substância Negra/patologia
20.
Nature ; 417(6885): 139, 2002 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-12000951

RESUMO

In the electrodeposition of metals, a widely used industrial technique, bubbles of gas generated near the cathode can adversely affect the quality of the metal coating. Here we use phase-contrast radiology with synchrotron radiation to witness directly and in real time the accumulation of zinc on hydrogen bubbles. This process explains the origin of the bubble-shaped defects that are common in electrodeposited coatings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA