Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Occup Environ Hyg ; 18(9): 430-435, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34383620

RESUMO

Personal protective equipment used by healthcare workers to mitigate disease transmission risks while caring for patients with high-consequence infectious diseases can impair normal body cooling mechanisms and exacerbate physiological strain. Symptoms of heat strain (e.g., cognitive impairment, confusion, muscle cramping) are especially harmful in the high-risk environment of high-consequence infectious disease care. In this pilot study, the core body temperatures of healthcare workers were assessed using an ingestible, wireless-transmission thermometer while performing patient care tasks common to a high-level isolation unit setting in powered air purifying respirator (PAPR)-level. The objective was to determine the potential for occupational health hazard due to heat stress in an environmentally controlled unit. Maximum core temperatures of the six participants ranged from 37.4 °C (99.3 °F) to 39.9 °C (103.8°F) during the 4-hr shift; core temperatures of half (n = 3) of the participants exceeded 38.5 °C (101.3 °F), the upper core temperature limit. Future investigations are needed to identify other heat stress risks both in and outside of controlled units. The ongoing COVID-19 pandemic offers unique opportunities for field-based research on risks of heat stress related to personal protective equipment in healthcare workers that can lead to both short- and long-term innovations in this field.


Assuntos
Temperatura Corporal/fisiologia , COVID-19/epidemiologia , Transtornos de Estresse por Calor/etiologia , Isolamento de Pacientes , Equipamento de Proteção Individual/efeitos adversos , Adulto , Índice de Massa Corporal , Feminino , Pessoal de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Saúde Ocupacional , Pandemias , Projetos Piloto , SARS-CoV-2
2.
Forensic Sci Med Pathol ; 15(1): 31-40, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30402743

RESUMO

In the United States of America, Medical Examiners and Coroners (ME/Cs) investigate approximately 20% of all deaths. Unexpected deaths, such as those occurring due to a deceased person under investigation for a highly infectious disease, are likely to fall under ME/C jurisdiction, thereby placing the ME/C and other morgue personnel at increased risk of contracting an occupationally acquired infection. This survey of U.S. ME/Cs' capabilities to address highly infectious decedents aimed to determine opportunities for improvement at ME/C facilities serving a state or metropolitan area. Data for this study was gathered via an electronic survey. Of the 177 electronic surveys that were distributed, the overall response rate was N = 108 (61%), with 99 of those 108 respondents completing all the questions within the survey. At least one ME/C responded from 47 of 50 states, and the District of Columbia. Select results were: less than half of respondents (44%) stated that their office had been involved in handling a suspected or confirmed highly infectious remains case and responses indicated medical examiners. Additionally, ME/C altered their personal protective equipment based on suspected versus confirmed highly infectious remains rather than taking an all-hazards approach. Standard operating procedures or guidelines should be updated to take an all-hazards approach, best-practices on handling highly infectious remains could be integrated into a standardized education, and evidence-based information on appropriate personal protective equipment selection could be incorporated into a widely disseminated learning module for addressing suspected or confirmed highly infectious remains, as those areas were revealed to be currently lacking.


Assuntos
Médicos Legistas/estatística & dados numéricos , Transmissão de Doença Infecciosa/prevenção & controle , Controle de Infecções/estatística & dados numéricos , Doenças Profissionais/prevenção & controle , Autopsia , Restos Mortais , Contenção de Riscos Biológicos/estatística & dados numéricos , Humanos , Controle de Infecções/normas , Necrotério , Equipamento de Proteção Individual/estatística & dados numéricos , Competência Profissional , Gestão da Segurança/estatística & dados numéricos , Inquéritos e Questionários , Estados Unidos
3.
J Clin Microbiol ; 56(2)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29167287

RESUMO

In late 2014, 56 hospitals in the United States were designated by state and federal public health authorities as specially designed high-level isolation units (HLIUs) equipped with advanced infrastructure, laboratory capabilities, and trained staff to care for patients with highly hazardous communicable diseases (HHCDs), such as Ebola virus disease. This survey describes the clinical laboratory support capabilities of U.S. HLIUs, including the specific test menus that HLIUs have identified to safely manage HHCD patients and the locations where such testing would be performed. In spring 2016, a survey was electronically distributed, as a fillable pdf file, to the 56 U.S. HLIUs. Site representatives completed the surveys, and data were coded and analyzed in an electronic spreadsheet, using descriptive statistics. Thirty-six HLIUs (64%) responded, and 33 completed the laboratory capabilities section. Thirty-one HLIUs (94%) had performed risk analyses for all laboratory procedures and equipment. Twenty-nine (88%) had decontamination procedures specified for all laboratory equipment used for patients with suspected or confirmed HHCDs. On-site laboratories in 27 HLIUs (81%) had the capacity to inventory and to securely store HHCD patient specimens. Ten HLIUs (31%) had at least one test they would conduct within the patient isolation room. The high-risk nature of HHCDs and the occupational exposures that may occur in clinical laboratories demand advanced preparation and risk assessment of work practices, laboratory equipment, and instrumentation by HLIU laboratories. Although risk analyses of clinical laboratory testing and equipment that HLIUs have conducted have likely focused on those for Ebola virus, HLIUs must be prepared to revise their current procedures for other HHCDs.


Assuntos
Doenças Transmissíveis/epidemiologia , Controle de Infecções/estatística & dados numéricos , Laboratórios Hospitalares/estatística & dados numéricos , Técnicas de Laboratório Clínico/instrumentação , Descontaminação , Humanos , Exposição Ocupacional/prevenção & controle , Isolamento de Pacientes , Medição de Risco/estatística & dados numéricos , Inquéritos e Questionários , Estados Unidos/epidemiologia
4.
J Nurs Adm ; 48(11): 553-560, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33216517

RESUMO

OBJECTIVE: To describe strategies used by US high-level isolation units (HLIUs) to recruit, train, and sustain a full team of multidisciplinary staff and identify how units are secured. BACKGROUND: Fifty-six US hospitals have been designated HLIUs, capable of providing safe care to patients with highly infectious disease. METHODS: An electronic survey was administered to the 56 HLIUs in spring of 2016. Responses were collected via a fillable PDF and analyzed using descriptive statistics. RESULTS: Thirty-six HLIUs (64%) responded; 33 completed surveys, and 3 reported no longer being a designated HLIU. HLIUs reported large numbers of multidisciplinary staff, primarily consisting of RNs and critical care clinicians. Nearly all HLIUs (94%) required orientation training, although hours varied. CONCLUSIONS: Over a short period, HLIUs recruited and trained significant numbers of staff with little guidance. Costs of ongoing trainings are considerable, and it remains unclear how HLIUs will continue funding these activities.

5.
J Public Health Manag Pract ; 24(5): E28-E33, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29227420

RESUMO

CONTEXT: US state public health departments played key roles in planning for and responding to confirmed and suspected cases of Ebola virus disease (EVD) during the 2014-2016 outbreak, including designating select hospitals as high-level isolation units (HLIUs) for EVD treatment in conjunction with the Centers for Disease Control and Prevention. OBJECTIVE: To identify existing guidelines and perspectives of state health departments pertaining to the management and transport of patients with EVD and other highly hazardous communicable diseases (HHCDs). DESIGN: An electronic 8-question survey with subquestions was administered as a fillable PDF. SETTING: The survey was distributed to publicly accessible e-mails of state health department employees. PARTICIPANTS: State epidemiologists, emergency preparedness directors, or chief medical officers from each of the 50 states and the District of Columbia were contacted; a representative from 36 states and the District of Columbia responded (73%). MAIN OUTCOME MEASURES: Descriptive statistics were used to identify the proportion of state health departments with various existing protocols. RESULTS: A majority of states reported that they would prefer patients confirmed with viral hemorrhagic fevers (eg, EVD, Marburg fever) and smallpox be transported to an HLIU for treatment rather than remain at the initial hospital of diagnosis. While most (89%) states had written guidelines for the safe transportation of patients with HHCDs, only 6 (16%) had written protocols for the management of accidents or other travel disruptions that may occur during HHCD transport within the state. Twenty-two state health departments (59%) had operationally exercised transport of a patient to an HLIU. CONCLUSIONS: Nearly half of states in the United States lack an HLIU, yet most prefer to have patients with HHCDs treated in high-level isolation. Recent budget cuts and uncertainty of future funding threaten the abilities of health departments to devote the necessary resources and staff to prepare for and deliver the desired care to HHCD cases. The lack of HLIUs in some states may complicate transport to a geographically proximate HLIU. Moreover, limited guidance on diseases that warrant high-level isolation may cause disagreement in HHCD patient placement between health departments, diagnosing facilities, and HLIUs.


Assuntos
Doenças Transmissíveis/diagnóstico , Planejamento em Desastres/métodos , Saúde Pública/métodos , Doenças Transmissíveis/epidemiologia , Planejamento em Desastres/estatística & dados numéricos , Ebolavirus/patogenicidade , Doença pelo Vírus Ebola/diagnóstico , Doença pelo Vírus Ebola/epidemiologia , Humanos , Isoladores de Pacientes/normas , Isoladores de Pacientes/tendências , Governo Estadual , Inquéritos e Questionários , Zika virus/patogenicidade , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/epidemiologia
6.
Emerg Infect Dis ; 23(6): 965-967, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28518036

RESUMO

To identify barriers to maintaining and applying capabilities of US high-level isolation units (HLIUs) used during the Ebola virus disease outbreak, during 2016 we surveyed HLIUs. HLIUs identified sustainability challenges and reported the highly infectious diseases they would treat. HLIUs expended substantial resources in development but must strategize models of sustainability to maintain readiness.


Assuntos
Defesa Civil/organização & administração , Doença pelo Vírus Ebola/prevenção & controle , Hospitais de Isolamento/provisão & distribuição , Ebolavirus/patogenicidade , Doença pelo Vírus Ebola/economia , Doença pelo Vírus Ebola/epidemiologia , Doença pelo Vírus Ebola/transmissão , Hospitais de Isolamento/economia , Humanos , Saúde Pública/métodos , Estados Unidos/epidemiologia
7.
J Occup Environ Hyg ; 14(9): 674-680, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28609169

RESUMO

PURPOSE: A United States industry-specific gap analysis survey of the death care sector-which comprises organizations and businesses affiliated with the funeral industry and the handling of human remains- was developed, the results analyzed, and training and education needs in relation to highly infectious disease mitigation and management were explored in an effort to identify where occupational health and safety can be enhanced in this worker population. METHODS: Collaborating national death care organizations distributed the 47-question electronic survey. N = 424 surveys were initiated and results recorded. The survey collected death care sector-specific information pertaining to the comfortability and willingness to handle highly infectious remains; perceptions of readiness, current policies and procedures in place to address highly infectious diseases; current highly infectious disease training levels, available resources, and personal protective equipment. RESULTS: One-third of respondents have been trained on how to manage highly infectious remains. There was a discrepancy between Supervisor/Management and Employee/Worker perceptions on employees' willingness and comfortability to manage potentially highly infectious remains. More than 40% of respondents did not know the correct routes of transmission for viral hemorrhagic fevers. CONCLUSIONS: Results suggest death care workers could benefit from increasing up-to-date industry-specific training and education on highly infectious disease risk mitigation and management. Professional death care sector organizations are positioned to disseminate information, training, and best practices.


Assuntos
Controle de Doenças Transmissíveis/métodos , Cremação/estatística & dados numéricos , Funerárias/estatística & dados numéricos , Práticas Mortuárias/educação , Doenças Transmissíveis/transmissão , Febres Hemorrágicas Virais/transmissão , Humanos , Inquéritos e Questionários , Estados Unidos
8.
J Occup Environ Hyg ; 14(6): 456-460, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28278065

RESUMO

An ultraviolet germicidal irradiation (UVGI) generator (the TORCH, ClorDiSys Solutions, Inc.) was used to compare the disinfection of surface coupons (plastic from a bedrail, stainless steel, and chrome-plated light switch cover) in a hospital room with walls coated with ultraviolet (UV)-reflective paint (Lumacept) or standard paint. Each surface coupon was inoculated with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus faecalis (VRE), placed at 6 different sites within a hospital room coated with UV-reflective paint or standard paint, and treated by 10 min UVC exposure (UVC dose of 0-688 mJ/cm2 between sites with standard paint and 0-553 mJ/cm2 with UV-reflective paint) in 8 total trials. Aggregated MRSA concentrations on plastic bedrail surface coupons were reduced on average by 3.0 log10 (1.8 log10 Geometric Standard Deviation [GSD]) with standard paint and 4.3 log10 (1.3 log10 GSD) with UV-reflective paint (p = 0.0005) with no significant reduction differences between paints on stainless steel and chrome. Average VRE concentrations were reduced by ≥4.9 log10 (<1.2 log10 GSD) on all surface types with UV-reflective paint and ≤4.1 log10 (<1.7 log10 GSD) with standard paint (p < 0.05). At 5 aggregated sites directly exposed to UVC light, MRSA concentrations on average were reduced by 5.2 log10 (1.4 log10 GSD) with standard paint and 5.1 log10 (1.2 log10 GSD) with UV-reflective paint (p = 0.017) and VRE by 4.4 log10 (1.4 log10 GSD) with standard paint and 5.3 log10 (1.1 log10 GSD) with UV-reflective paint (p < 0.0001). At one indirectly exposed site on the opposite side of the hospital bed from the UVGI generator, MRSA concentrations on average were reduced by 1.3 log10 (1.7 log10 GSD) with standard paint and 4.7 log10 (1.3 log10 GSD) with UV-reflective paint (p < 0.0001) and VRE by 1.2 log10 (1.5 log10 GSD) with standard paint and 4.6 log10 (1.1 log10 GSD) with UV-reflective paint (p < 0.0001). Coating hospital room walls with UV-reflective paint enhanced UVGI disinfection of nosocomial bacteria on various surfaces compared to standard paint, particularly at a surface placement site indirectly exposed to UVC light.


Assuntos
Desinfecção/métodos , Staphylococcus aureus Resistente à Meticilina/efeitos da radiação , Pintura , Enterococos Resistentes à Vancomicina/efeitos da radiação , Contagem de Colônia Microbiana , Infecção Hospitalar/prevenção & controle , Desinfecção/instrumentação , Contaminação de Equipamentos , Quartos de Pacientes , Raios Ultravioleta
9.
J Clin Microbiol ; 54(4): 1031-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26842705

RESUMO

Fifty-five hospitals in the United States have been designated Ebola treatment centers (ETCs) by their state and local health authorities. Designated ETCs must have appropriate plans to manage a patient with confirmed Ebola virus disease (EVD) for the full duration of illness and must have these plans assessed through a CDC site visit conducted by an interdisciplinary team of subject matter experts. This study determined the clinical laboratory capabilities of these ETCs. ETCs were electronically surveyed on clinical laboratory characteristics. Survey responses were returned from 47 ETCs (85%). Forty-one (87%) of the ETCs planned to provide some laboratory support (e.g., point-of-care [POC] testing) within the room of the isolated patient. Forty-four (94%) ETCs indicated that their hospital would also provide clinical laboratory support for patient care. Twenty-two (50%) of these ETC clinical laboratories had biosafety level 3 (BSL-3) containment. Of all respondents, 34 (72%) were supported by their jurisdictional public health laboratory (PHL), all of which had available BSL-3 laboratories. Overall, 40 of 44 (91%) ETCs reported BSL-3 laboratory support via their clinical laboratory and/or PHL. This survey provided a snapshot of the laboratory support for designated U.S. ETCs. ETCs have approached high-level isolation critical care with laboratory support in close proximity to the patient room and by distributing laboratory support among laboratory resources. Experts might review safety considerations for these laboratory testing/diagnostic activities that are novel in the context of biocontainment care.


Assuntos
Técnicas de Laboratório Clínico/métodos , Testes Diagnósticos de Rotina/métodos , Doença pelo Vírus Ebola/diagnóstico , Laboratórios , Contenção de Riscos Biológicos/normas , Humanos , Inquéritos e Questionários , Estados Unidos
10.
J Occup Environ Hyg ; 13(9): 690-8, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27028152

RESUMO

The estimated 721,800 hospital acquired infections per year in the United States have necessitated development of novel environmental decontamination technologies such as ultraviolet germicidal irradiation (UVGI). This study evaluated the efficacy of a novel, portable UVGI generator (the TORCH, ChlorDiSys Solutions, Inc., Lebanon, NJ) to disinfect surface coupons composed of plastic from a bedrail, stainless steel, chrome-plated light switch cover, and a porcelain tile that were inoculated with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus faecalis (VRE). Each surface type was placed at 6 different sites within a hospital room and treated by 10-min ultraviolet-C (UVC) exposures using the TORCH with doses ranging from 0-688 mJ/cm(2) between sites. Organism reductions were compared with untreated surface coupons as controls. Overall, UVGI significantly reduced MRSA by an average of 4.6 log10 (GSD: 1.7 log10, 77% inactivation, p < 0.0001) and VRE by an average of 3.9 log10 (GSD: 1.7 log10, 65% inactivation, p < 0.0001). MRSA on bedrail was reduced significantly (p < 0.0001) less than on other surfaces, while VRE was reduced significantly less on chrome (p = 0.0004) and stainless steel (p = 0.0012) than porcelain tile. Organisms out of direct line of sight of the UVC generator were reduced significantly less (p < 0.0001) than those directly in line of sight. UVGI was found an effective method to inactivate nosocomial pathogens on surfaces evaluated within the hospital environment in direct line of sight of UVGI treatment with variation between organism and surface types.


Assuntos
Desinfecção/instrumentação , Staphylococcus aureus Resistente à Meticilina/efeitos da radiação , Raios Ultravioleta , Enterococos Resistentes à Vancomicina/efeitos da radiação , Contagem de Colônia Microbiana , Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Hospitais , Quartos de Pacientes
11.
Prehosp Emerg Care ; 19(2): 179-83, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25380073

RESUMO

The Nebraska Biocontainment Unit through the Nebraska Medical Center in Omaha, Nebraska, recently received patients with confirmed Ebola virus from West Africa. The Nebraska Biocontainment Unit and Omaha Fire Department's emergency medical services (EMS) coordinated patient transportation from airport to the high-level isolation unit. Transportation of these highly infectious patients capitalized on over 8 years of meticulous planning and rigorous infection control training to ensure the safety of transport personnel as well as the community during transport. Although these transports occurred with advanced notice and after confirmed Ebola virus disease (EVD) diagnosis, approaches and key lessons acquired through this effort will advance the ability of any EMS provider to safely transport a confirmed or suspected patient with EVD. Three critical areas have been identified from our experience: ambulance preparation, appropriate selection and use of personal protective equipment, and environmental decontamination.


Assuntos
Ebolavirus/patogenicidade , Serviços Médicos de Emergência/normas , Doença pelo Vírus Ebola/prevenção & controle , Controle de Infecções , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Transporte de Pacientes/normas , Protocolos Clínicos , Emergências , Doença pelo Vírus Ebola/transmissão , Humanos , Isolamento de Pacientes , Gestão da Segurança
12.
Am J Infect Control ; 46(2): 133-138, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28958444

RESUMO

BACKGROUND: The recent Ebola outbreak led to the development of Ebola virus disease (EVD) best practices in clinical settings. However, after the care of EVD patients, proper medical waste management and disposal was identified as a crucial component to containing the virus. Category A waste-contaminated with EVD and other highly infectious pathogens-is strictly regulated by governmental agencies, and led to only several facilities willing to accept the waste. METHODS: A pilot survey was administered to determine if U.S. medical waste facilities are prepared to handle or transport category A waste, and to determine waste workers' current extent of training to handle highly infectious waste. RESULTS: Sixty-eight percent of survey respondents indicated they had not determined if their facility would accept category A waste. Of those that had acquired a special permit, 67% had yet to modify their permit since the EVD outbreak. This pilot survey underscores gaps in the medical waste industry to handle and respond to category A waste. Furthermore, this study affirms reports a limited number of processing facilities are capable or willing to accept category A waste. CONCLUSIONS: Developing the proper management of infectious disease materials is essential to close the gaps identified so that states and governmental entities can act accordingly based on the regulations and guidance developed, and to ensure public safety.


Assuntos
Controle de Doenças Transmissíveis/métodos , Doenças Transmissíveis/transmissão , Eliminação de Resíduos de Serviços de Saúde/métodos , Eliminação de Resíduos de Serviços de Saúde/normas , Resíduos de Serviços de Saúde/classificação , Coleta de Dados , Surtos de Doenças/prevenção & controle , Zeladoria Hospitalar , Humanos , Projetos Piloto , Estados Unidos
13.
Disaster Med Public Health Prep ; 12(6): 675-679, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29352835

RESUMO

OBJECTIVE: Despite lessons learned from the recent Ebola epidemic, attempts to survey and determine non-health care worker, industry-specific needs to address highly infectious diseases have been minimal. The aircraft rescue and fire fighting (ARFF) industry is often overlooked in highly infectious disease training and education, even though it is critical to their field due to elevated occupational exposure risk during their operations. METHODS: A 44-question gap analysis survey was distributed to the ARFF Working Group to determine where highly infectious education and training can be improved. In total, N=245 responses were initiated and collected. Descriptive statistics were generated utilizing Qualtrics Software Version 2016.17©. RESULTS: Supervisors perceived Frontline respondents to be more willing and comfortable to encounter potential highly infectious disease scenarios than the Frontline indicated. More than one-third of respondents incorrectly marked transmission routes of viral hemorrhagic fevers. There were discrepancies in self-reports on the existence of highly infectious disease orientation and skills demonstration, employee resources, and personal protective equipment policies, with a range of 7.5%-24.0% more Supervisors than Frontline respondents marking activities as conducted. CONCLUSIONS: There are deficits in highly infectious disease knowledge, skills, and abilities among ARFF members that must be addressed to enhance member safety, health, and well-being. (Disaster Med Public Health Preparedness. 2018;12:675-679).


Assuntos
Medicina Aeroespacial/métodos , Bombeiros/educação , Avaliação das Necessidades/tendências , Trabalho de Resgate/métodos , Ensino/normas , Medicina Aeroespacial/educação , Aeronaves , Bombeiros/estatística & dados numéricos , Doença pelo Vírus Ebola/diagnóstico , Doença pelo Vírus Ebola/transmissão , Humanos , Trabalho de Resgate/tendências , Inquéritos e Questionários , Ensino/tendências
14.
Am J Infect Control ; 46(3): 246-252, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29499788

RESUMO

BACKGROUND: The Ebola virus disease outbreak highlighted the lack of consistent guidelines and training for workers outside of hospital settings. Specifically, emergency medical services (EMS) workers, who are frequently the first professionals to evaluate patients, often do not have advanced notice of patient diagnosis, and have limited time in their national curricula devoted to highly infectious disease (HID) identification and containment. All of these can place them at increased risk. To explore the depth of US EMS practitioners' HID training and education, a pilot gap analysis survey was distributed to determine where the aforementioned can be bolstered to increase occupational safety. METHODS: Electronic surveys were distributed to EMS organization members. The survey collected respondent willingness to encounter HID scenarios; current policies and procedures; and levels of knowledge, training, and available resources to address HIDs. RESULTS: A total of 2,165 surveys were initiated and collected. Eighty percent of frontline personnel were aware that their agency had an HID standard operating guideline. Almost 85% of respondents correctly marked routes of exposure for select HIDs. More than half of respondents indicated no maximum shift times in personal protective equipment. DISCUSSION: This research suggests EMS practitioners could benefit from enhanced industry-specific education, training, and planning on HID mitigation and management. CONCLUSION: Strengthening EMS preparedness in response to suspected or confirmed HID cases may not only improve patient outcomes, but also worker and community safety.


Assuntos
Controle de Doenças Transmissíveis/métodos , Controle de Doenças Transmissíveis/normas , Serviços Médicos de Emergência/métodos , Serviços Médicos de Emergência/normas , Pessoal de Saúde/educação , Doenças Transmissíveis/transmissão , Coleta de Dados , Serviço Hospitalar de Emergência , Tratamento de Emergência , Guias como Assunto , Humanos , Estados Unidos
15.
Health Secur ; 15(5): 519-526, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29058966

RESUMO

The 2014-2016 Ebola outbreak in West Africa prompted a select group of US hospitals to establish high-level isolation units equipped with advanced engineering controls, trained staff, and stringent protocols to safely treat highly infectious disease patients. This survey details the comprehensive infection control protocols developed by these units, including for decontamination of units, post-mortem management, liquid waste disposal, and personal protective equipment (PPE) use. In spring 2016, a survey was electronically distributed to the 56 original Centers for Disease Control and Prevention (CDC)-designated high-level isolation units. Responses were collected via a fillable PDF and analyzed using descriptive statistics. Thirty-six (64%) high-level isolation units responded; 33 completed the survey, and 3 reported they no longer maintained high-level isolation unit capabilities. Nearly all responding units had written procedures for decontamination, liquid waste disposal, and PPE use; however, infection control protocols varied between units. High-level isolation units implemented multiple strategies in promoting hand hygiene among staff and in monitoring correct PPE use. Maximum time allowed in full PPE was restricted in all but 2 units (average of 3.45 hours per shift). Almost all (94%) had written procedures for the management of human remains, although only 2 units had written protocols for an autopsy of a patient with a highly infectious disease. While the vast majority of high-level isolation units reported having written protocols for infection control practices, staff compliance and procedural application are the true indicators of the state of preparedness. Therefore, rigorous training and staff adherence to infection control practices is critical to minimizing exposure risks.


Assuntos
Doenças Transmissíveis/epidemiologia , Controle de Infecções/normas , Isolamento de Pacientes/métodos , Autopsia/métodos , Descontaminação/normas , Higiene das Mãos , Humanos , Exposição Ocupacional/prevenção & controle , Isolamento de Pacientes/organização & administração , Equipamento de Proteção Individual/estatística & dados numéricos , Eliminação de Resíduos Líquidos/métodos
16.
J Interprof Educ Pract ; 1(3): 97-99, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32289082

RESUMO

Caring for patients with Ebola virus disease (EVD) in the Nebraska Biocontainment Unit (NBU) has necessitated and enabled extensive interprofessional relationships and the creation of a collaborative care model. Critical aspects of NBU functionality include a constructive leadership environment, staff inclusion and consideration during protocol development, and a culture of partnership and communication.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA