Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Mol Pharm ; 16(4): 1498-1506, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30821463

RESUMO

Several radiolabeled folic acid conjugates have been developed for targeted imaging and therapy. However, the therapeutic concept with radiolabeled folate conjugates has not yet been applied to clinical applications owing to the high renal absorbed dose. The effectiveness of targeted radionuclide therapy (TRT) depends primarily on the absorbed dose rate and on the total absorbed dose delivered to the tumor and to normal tissue. Owing to various limitations associated with organ level dosimetry, voxel-based dosimetry has become essential for the assessment of a more  accurate absorbed dose during TRT. In this study, we synthesized iron oxide nanoparticle (IONP)-conjugated radiolabeled folate (177Lu-IONP-Folate) and performed voxel-based dosimetry using SPECT/CT images of normal mice through direct Geant4 application for emission tomography (GATE) Monte Carlo (MC) simulation. We also prepared 177Lu-Folate and 177Lu-IONPs for the comparison of absorbed doses with that of 177Lu-IONP-Folate. In addition, we calculated the mean absorbed dose at the organ-level using the medical internal radiation dose (MIRD) schema. The radioactivities of all three radiotracers were mainly accumulated in the liver and kidneys immediately after injection. For the kidneys, the voxel-based absorbed doses obtained with 177Lu-IONP-Folate, 177Lu-Folate, and 177Lu-IONPs were 1.01 ± 0.17, 2.46 ± 0.50, and 0.52 ± 0.08 Gy/MBq, respectively. The renal absorbed dose decreased significantly (∼half) when 177Lu-IONP-Folate was used compared with when the 177Lu-Folate only was used. The mean absorbed dose values obtained at organ-level using the MIRD schema were comparable to voxel-based absorbed doses estimated with GATE MC. The voxel-based absorbed dose values obtained in this study of individualized activity show that the renal absorbed dose could be reduced to almost half with 177Lu-IONP-Folate. Therefore, 177Lu-IONP-Folate could be clinically applicable in the TRT of folate receptor-positive cancers in a personalized manner when using the voxel-based dosimetry method.


Assuntos
Compostos Férricos/química , Ácido Fólico/química , Lutécio/administração & dosagem , Nanopartículas/química , Radioisótopos/administração & dosagem , Compostos Radiofarmacêuticos/administração & dosagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Neoplasias do Colo do Útero/radioterapia , Algoritmos , Animais , Feminino , Humanos , Lutécio/química , Camundongos , Camundongos Endogâmicos BALB C , Radioisótopos/química , Radiometria , Compostos Radiofarmacêuticos/química , Células Tumorais Cultivadas , Proteína Tumoral 1 Controlada por Tradução , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/metabolismo , Ensaios Antitumorais Modelo de Xenoenxerto
2.
J Cereb Blood Flow Metab ; 35(12): 2098-108, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26243707

RESUMO

In recent years, several linearized model approaches for fast and reliable parametric neuroreceptor mapping based on dynamic nuclear imaging have been developed from the simplified reference tissue model (SRTM) equation. All the methods share the basic SRTM assumptions, but use different schemes to alleviate the effect of noise in dynamic-image voxels. Thus, this study aimed to compare those approaches in terms of their performance in parametric image generation. We used the basis function method and MRTM2 (multilinear reference tissue model with two parameters), which require a division process to obtain the distribution volume ratio (DVR). In addition, a linear model with the DVR as a model parameter (multilinear SRTM) was used in two forms: one based on linear least squares and the other based on extension of total least squares (TLS). Assessment using simulated and actual dynamic [(11)C]ABP688 positron emission tomography data revealed their equivalence with the SRTM, except for different noise susceptibilities. In the DVR image production, the two multilinear SRTM approaches achieved better image quality and regional compatibility with the SRTM than the others, with slightly better performance in the TLS-based method.


Assuntos
Mapeamento Encefálico/métodos , Oximas , Tomografia por Emissão de Pósitrons/métodos , Piridinas , Compostos Radiofarmacêuticos , Células Receptoras Sensoriais , Algoritmos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Análise dos Mínimos Quadrados , Modelos Lineares , Doença de Parkinson/diagnóstico por imagem , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA