Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Chem Commun (Camb) ; 50(76): 11226-9, 2014 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-25116379

RESUMO

Oxygen annealing of thick MoS2 films results in randomly oriented and controllable triangular etched shapes, forming pits with uniform etching angles. These etching morphologies differ across the sample based on the defect sites situated on the basal plane surface, forming numerous features in different bulk sample thicknesses.

3.
Artigo em Inglês | MEDLINE | ID: mdl-19213647

RESUMO

Very large element counts (16,000-65,000) are required for 2-D arrays for 3-D rectilinear imaging. The difficulties in fabricating and interconnecting 2-D arrays with a large number of elements (>5,000) have limited the development of suitable transducers for 3-D rectilinear imaging. In this paper, we propose an alternative solution to this problem by using a dual-layer transducer array design. This design consists of 2 perpendicular 1-D arrays for clinical 3-D imaging of targets near the transducer. These targets include the breast, carotid artery, and musculoskeletal system. This transducer design reduces the fabrication complexity and the channel count, making 3-D rectilinear imaging more realizable. With this design, an effective N x N 2-D array can be developed using only N transmitters and N receivers. This benefit becomes very significant when N becomes greater than 128, for example. To demonstrate feasibility, we constructed a 4 x 4 cm prototype dual-layer array. The transmit array uses diced PZT-5H elements, and the receive array is a single sheet of undiced P[VDF-TrFE] copolymer. The receive elements are defined by the copper traces on the flexible interconnect circuit. The measured -6 dB fractional bandwidth was 80% with a center frequency of 4.8 MHz. At 5 MHz, the nearest neighbor crosstalk of the PZT array and PVDF array was -30.4 +/- 3.1 dB and -28.8 +/- 3.7 dB, respectively. This dual-layer transducer was interfaced with an Ultrasonix Sonix RP system, and a synthetic aperture 3-D data set was acquired. We then performed offline 3-D beamforming to obtain volumes of nylon wire targets. The theoretical lateral beamwidth was 0.52 mm compared with measured beamwidths of 0.65 mm and 0.67 mm in azimuth and elevation, respectively. Then, 3-D images of an 8 mm diameter anechoic cyst phantom were also acquired.


Assuntos
Imageamento Tridimensional/instrumentação , Transdutores , Ultrassonografia/instrumentação , Acústica , Cerâmica/química , Simulação por Computador , Modelos Teóricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA