RESUMO
Cyclic volatile methyl siloxanes (cVMS) are ubiquitous in hair care products (HCPs). cVMS emissions from HCPs are of concern, given the potential adverse impact of siloxanes on the environment and human health. To characterize cVMS emissions and exposures during the use of HCPs, realistic hair care experiments were conducted in a residential building. Siloxane-based HCPs were tested using common hair styling techniques, including straightening, curling, waving, and oiling. VOC concentrations were measured via proton-transfer-reaction time-of-flight mass spectrometry. HCP use drove rapid changes in the chemical composition of the indoor atmosphere. cVMS dominated VOC emissions from HCP use, and decamethylcyclopentasiloxane (D5) contributed the most to cVMS emissions. cVMS emission factors (EFs) during hair care routines ranged from 110-1500 mg/person and were influenced by HCP type, styling tools, operation temperatures, and hair length. The high temperature of styling tools and the high surface area of hair enhanced VOC emissions. Increasing the hair straightener temperature from room temperature to 210 °C increased cVMS EFs by 50-310%. Elevated indoor cVMS concentrations can result in substantial indoor-to-outdoor transport of cVMS via ventilation (0.4-6 tons D5/year in the U.S.); thus, hair care routines may augment the abundance of cVMS in the outdoor atmosphere.
Assuntos
Preparações para Cabelo , Compostos Orgânicos Voláteis , Humanos , Siloxanas/análise , Espectrometria de Massas , Atmosfera , Preparações para Cabelo/análise , Monitoramento AmbientalRESUMO
NCl3 is formed as a disinfection byproduct in chlorinated swimming pools and can partition between the liquid and gas phases. Exposure to gas-phase NCl3 has been linked to asthma and can irritate the eyes and respiratory airways, thereby affecting the health and athletic performance of swimmers. This study involved an investigation of the spatiotemporal dynamics of gas-phase NCl3 in an aquatic center during a collegiate swim meet. Real-time (up to 1 Hz) measurements of gas-phase NCl3 were made via a novel on-line derivatization cavity ring-down spectrometer and a proton transfer reaction time-of-flight mass spectrometer. Significant temporal variations in gas-phase NCl3 and CO2 concentrations were observed across varying time scales, from seconds to hours. Gas-phase NCl3 concentrations increased with the number of active swimmers due to swimming-enhanced liquid-to-gas transfer of NCl3, with peak concentrations between 116 and 226 ppb. Strong correlations between concentrations of gas-phase NCl3 with concentrations of CO2 and water (relative humidity) were found and attributed to similar features in their physical transport processes in pool air. A vertical gradient in gas-phase NCl3 concentrations was periodically observed above the water surface, demonstrating that swimmers can be exposed to elevated levels of NCl3 beyond those measured in the bulk air.
Assuntos
Compostos de Nitrogênio , Piscinas , Cloretos , DesinfecçãoRESUMO
The increasing prevalence of hazardous chemical incidents in the United States necessitates the implementation of analytically robust, rapid, and reliable screening techniques for toxicant mixture analysis to understand short- and long-term health impacts of environmental exposures. A recent chemical disaster in East Palestine, Ohio has underscored the importance of thorough contamination assessment. On February 03, 2023, a Norfolk Southern train derailment prompted a chemical spill and fires. An open burn involving over 100,000 gal of vinyl chloride was conducted three days later. Hazardous compounds were released into air, water, and soil. To provide time-sensitive exposure data for emergency response, this study outlines a novel methodology for rapid characterization of chemical contamination of environmental media to support disaster response efforts. A controlled static headspace sampling system, in conjunction with a high-resolution proton transfer reaction time-of-flight mass spectrometer (PTR-TOF-MS), was developed to characterize volatile organic compounds (VOCs) in surface water samples collected near the East Palestine train derailment site. Spatial variations were observed in the chemical composition of surface water samples collected at different locations. Hydrocarbons were found to be the most abundant chemical group of all surface water samples, contributing 50 % to 97 % to the total headspace VOC mass. Compounds commonly detected in surface water samples, including benzene, styrene, xylene, and methyl tert-butyl ether (MTBE) were also observed in most surface water samples, with aqueous concentrations typically at ng/L levels. This study demonstrated the potential of the proposed methodology to be applied for rapid field screening of volatile chemicals in water samples in order to enable fast emergency response to chemical disasters and environmental hazards.
RESUMO
Scented volatile chemical products (sVCPs) are frequently used indoors. We conducted field measurements in a residential building to investigate new particle formation (NPF) from sVCP emissions. State-of-the-art instrumentation was used for real-time monitoring of indoor atmospheric nanocluster aerosol (NCA; 1-3 nm particles) size distributions and terpene mixing ratios. We integrated our NCA measurements with a comprehensive material balance model to analyze sVCP-nucleated indoor NCA dynamics. Our results reveal that sVCPs significantly increase indoor terpene mixing ratios (10-1,000 ppb), exceeding those in outdoor forested environments. The emitted terpenes react with indoor atmospheric O3 and initiate indoor NPF, resulting in nucleation rates as high as â¼105 cm-3 s-1 and condensational growth rates up to 300 nm h-1; these are orders of magnitude higher than those reported during outdoor NPF events. Notably, high particle nucleation rates significantly increase indoor atmospheric NCA concentrations (105-108 cm-3), and high growth rates drive their survival and growth to sizes that efficiently reach the deepest regions of the human respiratory system. We found sVCP-nucleated NCA to cause respiratory exposures and dose rates comparable to or exceeding those from primary aerosol sources such as gas stoves and diesel engines, highlighting their significant impact on indoor atmospheric environments.
RESUMO
Nanocluster aerosol (NCA: particles in the size range of 1-3â nm) are a critically important, yet understudied, class of atmospheric aerosol particles. NCA efficiently deposit in the human respiratory system and can translocate to vital organs. Due to their high surface area-to-mass ratios, NCA are associated with a heightened propensity for bioactivity and toxicity. Despite the human health relevance of NCA, little is known regarding the prevalence of NCA in indoor environments where people spend the majority of their time. In this study, we quantify the formation and transformation of indoor atmospheric NCA down to 1â nm via high-resolution online nanoparticle measurements during propane gas cooking in a residential building. We observed a substantial pool of sub-1.5â nm NCA in the indoor atmosphere during cooking periods, with aerosol number concentrations often dominated by the newly formed NCA. Indoor atmospheric NCA emission factors can reach up to â¼1016â NCA/kg-fuel during propane gas cooking and can exceed those for vehicles with gasoline and diesel engines. Such high emissions of combustion-derived indoor NCA can result in substantial NCA respiratory exposures and dose rates for children and adults, significantly exceeding that for outdoor traffic-associated NCA. Combustion-derived indoor NCA undergo unique size-dependent physical transformations, strongly influenced by particle coagulation and condensation of low-volatility cooking vapors. We show that indoor atmospheric NCA need to be measured directly and cannot be predicted using conventional indoor air pollution markers such as PM2.5 mass concentrations and NO x (NO + NO2) mixing ratios.
RESUMO
We conducted an experimental case study to demonstrate the application of proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) for mobile breathing zone (BZ) monitoring of volatile chemical exposures in workplace environments during COVID-19 disinfection activities. The experiments were conducted in an architectural engineering laboratory-the Purdue zero Energy Design Guidance for Engineers (zEDGE) Tiny House, which served as a simulated workplace environment. Controlled disinfection activities were carried out on impermeable high-touch indoor surfaces, including the entry door, kitchen countertop, toilet bowl, bathroom sink, and shower. Worker inhalation exposure to volatile organic compounds (VOCs) was evaluated by attaching the PTR-TOF-MS sampling line to the researcher's BZ while the disinfection activity was carried out throughout the entire building. The results demonstrate that significant spatiotemporal variations in VOC concentrations can occur in the worker's BZ during multi-surface disinfection events. Application of high-resolution monitoring techniques, such as PTR-TOF-MS, are needed to advance characterization of worker exposures towards the development of appropriate mitigation strategies for volatile disinfectant chemicals.
Assuntos
COVID-19 , Exposição Ocupacional , Humanos , Prótons , Desinfecção , Espectrometria de Massas/métodos , Local de TrabalhoRESUMO
Emerging sodium-ion batteries (NIBs) and potassium-ion batteries (KIBs) show promise in complementing lithium-ion battery (LIB) technology and diversifying the battery market. Hard carbon is a potential anode candidate for LIBs, NIBs, and KIBs due to its high capacity, sustainability, wide availability, and stable physicochemical properties. Herein, a series of hard carbons is synthesized by hydrothermal carbonization and subsequent pyrolysis at different temperatures to finely tune their structural properties. When tested as anodes, the hard carbons exhibit differing ion-storage trends for Li, Na, and K, with NIBs achieving the highest reversible capacity. Extensive materials and electrochemical characterizations are carried out to study the correlation of structural features with electrochemical performance and to explain the specific mechanisms of alkali-ion storage in hard carbons. In addition, the best-performing hard carbon is tested against a sodium cathode Na3 V2 (PO4 )3 in a Na-ion pouch cell, displaying a high power density of 2172 W kg-1 at an energy density of 181.5 Wh kg-1 (based on the total weight of active materials in both anode and cathode). The Na-ion pouch cell also shows stable ultralong-term cycling (9000 h or 5142 cycles) and demonstrates the promising potential of such materials as sustainable, scalable anodes for beyond Li-batteries.
RESUMO
Surface cleaning using commercial disinfectants, which has recently increased during the coronavirus disease 2019 pandemic, can generate secondary indoor pollutants both in gas and aerosol phases. It can also affect indoor air quality and health, especially for workers repeatedly exposed to disinfectants. Here, we cleaned the floor of a mechanically ventilated office room using a commercial cleaner while concurrently measuring gas-phase precursors, oxidants, radicals, secondary oxidation products, and aerosols in real-time; these were detected within minutes after cleaner application. During cleaning, indoor monoterpene concentrations exceeded outdoor concentrations by two orders of magnitude, increasing the rate of ozonolysis under low (<10 ppb) ozone levels. High number concentrations of freshly nucleated sub-10-nm particles (≥105 cm-3) resulted in respiratory tract deposited dose rates comparable to or exceeding that of inhalation of vehicle-associated aerosols.
RESUMO
The COVID-19 pandemic has resulted in increased usage of ethanol-based disinfectants for surface inactivation of SARS-CoV-2 in buildings. Emissions of volatile organic compounds (VOCs) and particles from ethanol-based disinfectant sprays were characterized in real-time (1 Hz) via a proton transfer reaction time-of-flight mass spectrometer (PTR-TOF-MS) and a high-resolution electrical low-pressure impactor (HR-ELPI+), respectively. Ethanol-based disinfectants drove sudden changes in the chemical composition of indoor air. VOC and particle concentrations increased immediately after application of the disinfectants, remained elevated during surface contact time, and gradually decreased after wiping. The disinfectants produced a broad spectrum of VOCs with mixing ratios spanning the sub-ppb to ppm range. Ethanol was the dominant VOC emitted by mass, with concentrations exceeding 103 µg m-3 and emission factors ranging from 101 to 102 mg g-1. Listed and unlisted diols, monoterpenes, and monoterpenoids were also abundant. The pressurized sprays released significant quantities (104-105 cm-3) of nano-sized particles smaller than 100 nm, resulting in large deposited doses in the tracheobronchial and pulmonary regions of the respiratory system. Inhalation exposure to VOCs varied with time during the building disinfection events. Much of the VOC inhalation intake (>60 %) occurred after the disinfectant was sprayed and wiped off the surface. Routine building disinfection with ethanol-based sprays during the COVID-19 pandemic may present a human health risk given the elevated production of volatile chemicals and nano-sized particles.
RESUMO
An activated carbon aerogel (ACA-500) with high surface area (1765 m2 g-1), pore volume (2.04 cm3 g-1), and hierarchical porous nanonetwork structure is prepared through direct activation of organic aerogel (RC-500) with a low potassium hydroxide ratio (1:1). Based on this substrate, a polyaniline (PANi)-coated activated carbon aerogel/sulfur (ACA-500-S@PANi) composite is prepared via a simple two-step procedure, including melt-infiltration of sublimed sulfur into ACA-500, followed by an in situ polymerization of aniline on the surface of ACA-500-S composite. The obtained ACA-500-S@PANi composite delivers a high reversible capacity up to 1208 mAh g-1 at 0.2C and maintains 542 mAh g-1 even at a high rate (3C). Furthermore, this composite exhibits a discharge capacity of 926 mAh g-1 at the initial cycle and 615 mAh g-1 after 700 cycles at 1C rate, revealing an extremely low capacity decay rate (0.48 per cycle). The excellent electrochemical performance of ACA-500-S@PANi can be attributed to the synergistic effect of hierarchical porous nanonetwork structure and PANi coating. Activated carbon aerogels with high surface area and unique three-dimensional (3D) interconnected hierarchical porous structure offer an efficient conductive network for sulfur, and a highly conductive PANi-coating layer further enhances conductivity of the electrode and prevents the dissolution of polysulfide species.