Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pediatr Diabetes ; 22(4): 594-604, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33576551

RESUMO

OBJECTIVE: Data on closed loop systems in young children with type 1 diabetes (T1D) are limited. We tested the efficacy and safety of an open-source, do-it-yourself automated insulin delivery system AndroidAPS in preschool and school-aged children. RESEARCH DESIGN AND METHODS: This retrospective study analyzed diabetes control in 18 preschool (3-7 years) and 18 school-aged children (8-14 years) with T1D who switched from a sensor-augmented pump (SAP) to AndroidAPS. We compared the CGM parameters and HbA1c levels 3 months before and 6 months after the initiation of AndroidAPS therapy and evaluated frequency of severe adverse events during AndroidAPS use, the most frequent reasons for its interruption, and the experience and psychosocial benefits of AndroidAPS use. RESULTS: General glycemic control was significantly improved after the switch from SAP to AndroidAPS. Time in range (TIR) increased in both preschool (70.8%-78.6%, p = 0.004) and school-aged children (77.2%-82.9%, p < 0.001), whereas HbA1c levels decreased (preschool children 53.8-48.5 mmol/mol, p < 0.001; school-aged children 52.6-45.1 mmol/mol, p = 0.001). Time spent in range of 3.0-3.8 mmol/L increased slightly in school children (2.6%-3.8%, p = 0.040), but not in preschool children (3.0%-3.0%, p = 0.913). Time spent at <3 mmol/L remained unchanged in both preschool (0.95%-0.67%, p = 0.432) and school-aged children (0.8%-0.8%, p = 1.000). No episodes of severe hypoglycemia or DKA and significant improvement of quality of life were reported by AndroidAPS users. CONCLUSIONS: AndroidAPS seems effective for T1D control both in preschool and school-age children but further validation by prospective studies is necessary.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Fatores Etários , Glicemia/metabolismo , Criança , Pré-Escolar , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
2.
Diabetes Technol Ther ; 20(11): 744-750, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30285476

RESUMO

OBJECTIVE: Officially licensed hybrid closed-loop systems are not currently available worldwide; therefore, open-source systems have become increasingly popular. Our aim was to assess the safety, feasibility, and efficacy of an open-source hybrid closed-loop system (AndroidAPS) versus SmartGuard® technology for day-and-night glucose control in children under extreme sports conditions. RESEARCH DESIGN AND METHODS: Twenty-two children (16 girls, 6-15 years of age, median HbA1c 56 ± 9 mmol/mol) were enrolled in this pivotal winter sports camp study. The participants were divided into two groups using either the AndroidAPS or SmartGuard technology. Physical exertion was represented by all-day alpine skiing. The primary endpoints were mean glucose level, time below the threshold of 3.9 mmol/L, and time within the target range of 3.9 to 10 mmol/L. RESULTS: The children using the AndroidAPS had significantly lower mean glycemia levels (7.2 ± 2.7 vs. 7.7 ± 2.8 mmol/L; 129.6 ± 49 vs. 138.6 ± 50 mg/dL, P < 0.042) than the children using the SmartGuard. The proportion of time below the target (median 5.0% ± 2.5% vs. 3.0% ± 2.3%, P = 0.6) and in the target zone (63% ± 9.5% vs. 63% ± 18%, P = 0.5) did not significantly differ. The AndroidAPS group experienced more frequent malfunctions of the cannula set (median 0.8 ± 0.4 vs. 0.2 ± 0.4, P = 0.02), which could have affected the results. No significant difference was found in the amount of carbohydrates consumed for the prevention and treatment of hypoglycemia [median 40 ± 23 vs. 25 ± 29 g/(patient ·3 days)]. No episodes of severe hypoglycemia or other serious adverse events were noted. CONCLUSIONS: This pilot study showed that the AndroidAPS system was a safe and feasible alternative to the SmartGuard Technology.


Assuntos
Automonitorização da Glicemia/instrumentação , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Glicemia/metabolismo , Automonitorização da Glicemia/métodos , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/fisiopatologia , Exercício Físico/fisiologia , Estudos de Viabilidade , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemia/etiologia , Hipoglicemia/prevenção & controle , Masculino , Projetos Piloto , Esqui/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA