Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Diagn Microbiol Infect Dis ; 62(3): 235-44, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18715735

RESUMO

The ARCHITECT Toxo IgG and IgG Avidity assays have been developed as a fully automated panel for immune status determination and acute infection exclusion. Resolved relative specificity and sensitivity of the ARCHITECT Toxo IgG assay were 99.6% (1359/1365) and 99.7% (1096/1099) as determined on pregnant females, blood donor, and diagnostic specimens. Seroconversion sensitivity of the ARCHITECT assay was comparable with the AxSYM Toxo IgG assay. The ARCHITECT Toxo IgG Avidity assay detected 100.0% (124/124) of acute phase specimens (<4 months after infection) as low avidity, whereas the Vidas Toxo IgG Avidity assay detected 98.9% (89/90) as low avidity. In summary, the ARCHITECT Toxo IgG assay, using recombinant antigens, showed excellent specificity and sensitivity for acute phase as well as past infection specimens. The ARCHITECT Toxoplasmosis panel can be reliably used to rule out acute Toxoplasma gondii infection in pregnant women.


Assuntos
Anticorpos Antiprotozoários/imunologia , Afinidade de Anticorpos , Imunoglobulina G/imunologia , Testes Sorológicos/métodos , Toxoplasma/imunologia , Toxoplasmose/diagnóstico , Doença Aguda , Animais , Anticorpos Antiprotozoários/sangue , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Gravidez , Complicações Parasitárias na Gravidez/diagnóstico , Complicações Parasitárias na Gravidez/parasitologia , Proteínas Recombinantes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Toxoplasma/isolamento & purificação
2.
J Clin Virol ; 35(4): 368-72, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16406797

RESUMO

BACKGROUND AND OBJECTIVES: Compliance with current regulations regarding the prevention of hepatitis C virus (HCV) transmission in the blood transfusion setting requires the use of sensitive assays for HCV antibody (anti-HCV) detection, which should, ideally, identify any donor having had prior contact with the virus. Therefore, low-level anti-HCV positive blood units should be detected by the screening assays, even those reflecting a past and resolved infection. To assess the sensitivity of two versions of an automated chemiluminescent microparticle immunoassay (CMIA) for anti-HCV screening (ARCHITECT Anti-HCV), 113 single serum samples containing low levels of anti-HCV, assessed by two immunoblot tests, were selected from 3686 samples received for confirmation of HCV infection by a reference laboratory over a 2-year period. MATERIALS AND METHODS: The panel included 17 samples with HCV RNA detected by the polymerase chain reaction (PCR) and 96 PCR negative samples with either positive or indeterminate (anti-Core and anti-NS3 alone) results by immunoblot. RESULTS: All but 13 specimens (100/113, 88.5%) were detected by the current version of the ARCHITECT Anti-HCV assay and 10 additional samples (110/113, 97.3%) tested positive in a modified version of the test. CONCLUSION: The results showed that the modification introduced in the ARCHITECT Anti-HCV assay achieves a significant sensitivity improvement including samples with low-level anti-HCV which are either PCR positive or negative.


Assuntos
Hepacivirus/imunologia , Anticorpos Anti-Hepatite C/sangue , Hepatite C/diagnóstico , Kit de Reagentes para Diagnóstico , Automação , Humanos , Imunoensaio , Immunoblotting , RNA Viral/sangue , Sensibilidade e Especificidade
3.
J Clin Virol ; 34(2): 97-103, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16122974

RESUMO

INTRODUCTION: The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. METHODS: The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. RESULTS: Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. CONCLUSION: This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.


Assuntos
Automação/métodos , Anticorpos Anti-Hepatite C/sangue , Hepatite C/diagnóstico , Imunoensaio/métodos , Doadores de Sangue , Humanos , Sensibilidade e Especificidade
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 786(1-2): 39-44, 2003 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-12651000

RESUMO

A DNA fragment coding for the human CD4 cytoplasmic domain (residues 394-433) was cloned into the pET15b expression vector. The resulting plasmid was used for synthesis of the polyhistidine-tagged 5.10(3) M(r) CD4 peptide in Escherichia coli BL21(DE3)Star. The CD4 cytoplasmic domain was purified under denaturing and reducing conditions by a two-step procedure using immobilized metal affinity chromatography and gel permeation chromatography. The purified CD4 cytoplasmic domain is soluble and functional without any specific refolding steps. The yield of the described purification procedure was approximately 5 mg peptide per liter culture volume.


Assuntos
Glicoproteínas de Membrana/isolamento & purificação , Sequência de Bases , Cromatografia de Afinidade , Cromatografia em Gel , Primers do DNA , Eletroforese em Gel de Poliacrilamida , Humanos , Proteínas Recombinantes/isolamento & purificação
5.
Transfusion ; 48(4): 584-93, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18194389

RESUMO

BACKGROUND: Before the introduction of human immunodeficiency virus (HIV) combination assays, serologic diagnosis of HIV infection was performed with assays that detected either antibodies or p24 antigen. Owing to the capability to detect the early appearance of p24 antigen, combination assays that are designed for simultaneous detection of antibodies and antigen can significantly reduce the diagnostic window. STUDY DESIGN AND METHODS: Specificity and sensitivity of a commercially available HIV antigen-antibody combination assay (Abbott PRISM; assay is not licensed by the FDA for use in the United States) were evaluated in a multicenter study by testing volunteer blood donors, hospitalized patients, seroconversion panels, and p24 antigen and HIV antibody subtype panels. Performance data were compared to a commercially available HIV combination assay and the PRISM HIV O Plus assay. RESULTS: Apparent specificity of 99.95 percent was observed in the donor population for the PRISM HIV antigen-antibody combination assay, and better seroconversion sensitivity was demonstrated compared with another combination assay and the PRISM HIV O Plus assay. Analytical HIV antigen detection sensitivity averaged 33 pg per mL on the Agence Française de Sécurité Sanitaire des Produits de Santé (AFSSAPS) panel. Furthermore, comparable antigen sensitivity was demonstrated for 32 HIV-1 group M subtype and group O panels. The PRISM HIV combination assay detected all HIV-1 group M and O and HIV-2 antibody-positive specimens evaluated. CONCLUSIONS: The PRISM HIV antigen-antibody combination assay demonstrated a significant reduction of the window period for diagnosis of HIV infection. The assay demonstrated enhanced specificity and sensitivity along with broad subtype detection. The assay performance represents the "state-of-the art" technology for serologic blood screening of HIV infection.


Assuntos
Seleção do Doador/métodos , Anticorpos Anti-HIV/sangue , Proteína do Núcleo p24 do HIV/imunologia , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , Humanos , Imunoensaio/métodos , Modelos Biológicos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA