Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ann Cardiothorac Surg ; 13(4): 339-345, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39157181

RESUMO

Robotic-assisted coronary bypass is an attractive option in the management of patients with isolated left anterior descending artery (LAD) disease or multi-vessel coronary disease providing the benefits of the left internal mammary artery (LIMA) to the LAD graft while avoiding the morbidity of a sternotomy. Although the learning curve is significant, both cardiothoracic surgery trainees as well as experienced coronary surgeons can learn this technique. As the prevalence of patients requiring these procedures increases, we must be prepared to respond by increasing our training of robotic coronary surgeons.

2.
Innovations (Phila) ; 18(3): 240-246, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37231667

RESUMO

OBJECTIVE: Many robotic mitral surgeons utilize right thoracotomy with transthoracic clamping of the aorta, while a smaller number employ a port-only endoscopic approach with endoaortic balloon occlusion of the aorta. We present our technique for a port-only endoscopic robotic approach with transthoracic clamping. METHODS: From July 2019 through December 2022, 133 patients underwent port-only endoscopic robotic mitral surgery with transthoracic clamp aortic occlusion and antegrade cardioplegia. Perfusion was through the femoral artery in 101 patients (76%) and axillary in 32 patients (24%). Clamp technique involved placing the clamp at the mid-ascending aorta, dynamic valve testing to 90 mm aortic root pressure, and closure of the cardioplegia cannula site prior to clamp removal. Indications for clamp utilization over balloon occlusion included both balloon supply issues and aortoiliac anatomy. RESULTS: Mitral repair was performed in 122 patients (92.7%) and mitral valve replacement in 11 patients (8.3%). Mean aortic occlusion time was 92 ± 21.4 min. Mean time from left atrial closure to clamp removal was 8.7 (7.2 to 12.8) min. There were no injuries to the aorta or surrounding structures, mortality, strokes, or renal failure. CONCLUSIONS: For robotic teams with endoaortic balloon capability, this technique may be useful in certain patients with aorto-iliac pathology or limited femoral artery access. Alternatively, robotic teams who employ transthoracic aortic clamping through a thoracotomy may find this technique useful to transition to a port-only endoscopic approach.


Assuntos
Doenças da Aorta , Procedimentos Cirúrgicos Cardíacos , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Endoscopia , Aorta/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos
3.
Innovations (Phila) ; 17(4): 297-303, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35770592

RESUMO

Objective: Mitral surgery is higher risk in patients with a previous median sternotomy. We describe an endoscopic robotic approach in this higher-risk cohort by an experienced robotic team. Methods: From January 2006 through June 2021, 152 consecutive patients with previous sternotomy cardiac surgery underwent mitral surgery using endoscopic robotics. Peripheral perfusion with endoaortic balloon occlusion was used in 148 patients (97.4%) and ventricular fibrillation in 4 patients (2.6%). Results: Mitral repair was performed in 73 patients (48%) including primary repair in 57 patients and re-repair in 16 patients, mitral replacement in 78 patients (51.3%) including primary replacement in 26 patients, conversion of a previous repair to replacement in 28 patients, and re-replacement in 24 patients. A paravalvular leak was primarily repaired in 1 patient (0.7%). Concomitant procedures included tricuspid repair in 28 patients (18.4%) and cryoablation in 8 patients (5.3%). Postoperative echocardiography in the mitral repair patients demonstrated none to mild regurgitation in 72 patients (98.6%). One repair patient (1.4%) had severe regurgitation and required robotic mitral replacement 5 days postoperatively. There were no paravalvular leaks in the mitral replacement patients. Operative mortality occurred in 3 patients (1.97%). Stroke occurred in 1 patient (0.7%), prolonged ventilation in 18 patients (11.8%), renal failure in 2 patients (1.4%), and re-exploration for bleeding in 10 patients (6.6%). Mean length of stay for the entire cohort was 5 ± 5.4 days. Conclusions: Robotic mitral valve surgery can be extended to patients with previous sternotomy with satisfactory efficacy and low operative mortality and morbidity.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Esternotomia/efeitos adversos
4.
Interv Cardiol Clin ; 11(1): 41-50, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34838296

RESUMO

The tricuspid valve is an often forgotten but relevant cause of significant morbidity and mortality. Serious consideration should be given to addressing the valve in patients undergoing left-sided valve surgery who have functional TR, or an enlarged annulus. Tricuspid repair with a ring annuloplasty has shown improved long-term survival and freedom from recurrent TR at as long as 15 years of follow-up compared to suture annuloplasty or other repairs where a prosthetic ring is not used.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA