Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Craniofac Surg ; 34(4): e334-e336, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36036497

RESUMO

Renal cell carcinoma (RCC) is the most common tumor of the kidney. Although RCC often metastasizes to other organs, metastasis to the head and neck region is rare, and metastasis to the mandible is very unusual. Given the fact that metastasis of primary neoplasms is not always predictable, it is essential to rule out metastatic carcinoma in jaw lesions. We herein report a rare presentation of metastasis of RCC to the mandible, in which the metastatic lesion in the oral cavity was found first, followed by the primary lesion, in a 22-year-old girl who suffered from pain in the left temporomandibular joint on mouth opening and hypoesthesia of the left chin, left lower lip, and left lower gum.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Feminino , Humanos , Adulto Jovem , Adulto , Carcinoma de Células Renais/secundário , Neoplasias Renais/patologia , Rim/patologia , Mandíbula/patologia , Boca
2.
J Craniofac Surg ; 33(5): 1578-1582, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34907946

RESUMO

ABSTRACT: The zygomatic bone is a structure that protrudes symmetrically on both sides of the midface and plays an important role in the overall aesthetic appearance of the face. Unlike Caucasians, the mesocephalic facial shape is predominant in Asians, and therefore, many people have a relatively laterally developed zygomatic bone. In Asians, when the zygomatic bone is excessively developed, it gives a strong and stubborn image, and aesthetically, many people want to reduce the zygomatic bone because they prefer an oval and slim face.To reduce the excessive zygomatic bone, a reduction malar- plasty through an intraoral and preauricular approach has been performed. Although reducing the zygomatic bone is not a big problem in most cases of symmetric reduction malarplasty, it is not easy to produce surgical results as intended by the surgeon in asymmetric malar patients or patients requiring a three-dimensional (3D) change of zygoma. In addition, because of the mobility of the zygoma segment, it may be difficult to drill holes and fix plate after osteotomy. Moreover, these factors can increase the possibility of malunion or nonunion.In this study, cutting guides made with the aid of 3D virtual surgery, 3D printing, and customized titanium plates manufactured with the computer-aided design/computer-aided manufacturing technology are used for 8 patients to maximize the recovery of 3D symmetry and minimize complications through accurate fixation after surgery. During the surgical procedures, screw hole drilling and osteotomy were performed using a cutting guide, and then, the malar segment was fixed by matching the premade customized plates with the predrilled holes. As a result of checking the accuracy of the surgery by superimposing the postoperative 3D cone beam computed tomography image and virtual surgery data based on the skull base, the 2 images almost overlapped and no significant differences were observed, so it was confirmed that the operation was performed exactly as planned.When using the 3D technology, it is possible to perform a more accurate surgery in patients with asymmetry due to congenital anomalies or trauma as well as simple asymmetry, so it can be concluded that using the 3D technology can overcome the limitations and disadvantages of the conventional method as in the cases in this study. The accurate prediction of soft tissue is still insufficient, and further research is needed to overcome this limitation.


Assuntos
Procedimentos de Cirurgia Plástica , Zigoma , Desenho Assistido por Computador , Humanos , Impressão Tridimensional , Procedimentos de Cirurgia Plástica/métodos , Stents , Zigoma/anormalidades , Zigoma/diagnóstico por imagem , Zigoma/cirurgia
3.
Proc Natl Acad Sci U S A ; 112(13): 3920-5, 2015 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-25775550

RESUMO

Recent advances in electrodes for noninvasive recording of electroencephalograms expand opportunities collecting such data for diagnosis of neurological disorders and brain-computer interfaces. Existing technologies, however, cannot be used effectively in continuous, uninterrupted modes for more than a few days due to irritation and irreversible degradation in the electrical and mechanical properties of the skin interface. Here we introduce a soft, foldable collection of electrodes in open, fractal mesh geometries that can mount directly and chronically on the complex surface topology of the auricle and the mastoid, to provide high-fidelity and long-term capture of electroencephalograms in ways that avoid any significant thermal, electrical, or mechanical loading of the skin. Experimental and computational studies establish the fundamental aspects of the bending and stretching mechanics that enable this type of intimate integration on the highly irregular and textured surfaces of the auricle. Cell level tests and thermal imaging studies establish the biocompatibility and wearability of such systems, with examples of high-quality measurements over periods of 2 wk with devices that remain mounted throughout daily activities including vigorous exercise, swimming, sleeping, and bathing. Demonstrations include a text speller with a steady-state visually evoked potential-based brain-computer interface and elicitation of an event-related potential (P300 wave).


Assuntos
Interfaces Cérebro-Computador , Orelha Externa , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Cognição , Computadores , Eletrodos , Eletrônica , Desenho de Equipamento , Potenciais Evocados P300 , Fractais , Humanos , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
4.
IEEE Open J Eng Med Biol ; 3: 47-57, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35519421

RESUMO

Bladder cancer (BC) is the most common urinary malignancy; however accurate diagnosis and prediction of recurrence after therapies remain elusive. This study aimed to develop a biosignature of immunotherapy-based responses using gene expression data. Publicly available BC datasets were collected, and machine learning (ML) approaches were applied to identify a novel biosignature to differentiate patient subgroups. Immune phenotyping of BC in the IMvigor210 dataset included three subtypes: inflamed, excluded, and desert immune. Immune phenotypes were analyzed with gene expressions using traditional but powerful classification methods such as random forests, Deep Neural Networks (DNN), Support Vector Machines (SVM) together with boosting and feature selection methods. Specifically, DNN yielded the highest area under the curve (AUC) with precision and recall (PR) curves and receiver operating characteristic (ROC) curves for each phenotype ([Formula: see text] and [Formula: see text], respectively) resulting in the identification of gene expression features useful for immune phenotype classification. Our results suggest significant potential to further develop and utilize machine learning algorithms for analysis of BC and its precaution. In conclusion, the findings from this study present a novel gene expression assay that can accurately discriminate BC patients from controls. Upon further validation in independent cohorts, this gene signature could be developed into a predictive test that can support clinical evaluation and patient care.

5.
Adv Mater ; 28(22): 4563, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27273442

RESUMO

The design of an ultrathin, conformal electronic device that integrates electrotactile stimulation with electromyography, temperature, and strain sensing in a single, simple platform is reported by J. A. Rogers and co-workers on page 4462. Demonstrated application possibilities include prosthetic control with sensory feedback, monitors, and stimulation signals related to lower back exertion, and electrical muscle stimulation with feedback control.


Assuntos
Esforço Físico , Estimulação Elétrica , Eletromiografia , Retroalimentação Sensorial , Músculo Esquelético
6.
Adv Mater ; 28(22): 4462-71, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26469201

RESUMO

The design of an ultrathin, conformal electronic device that integrates electrotactile stimulation with electromyography, temperature, and strain sensing in a single, simple platform is reported. Experiments demonstrate simultaneous use of multiple modes of operation of this type of device in the sensorimotor control of robotic systems, in the monitoring of lower back exertion and in muscle stimulation.


Assuntos
Eletromiografia/instrumentação , Esforço Físico , Epiderme , Humanos , Músculo Esquelético
7.
Nat Commun ; 5: 3266, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24509865

RESUMO

Stretchable electronics provide a foundation for applications that exceed the scope of conventional wafer and circuit board technologies due to their unique capacity to integrate with soft materials and curvilinear surfaces. The range of possibilities is predicated on the development of device architectures that simultaneously offer advanced electronic function and compliant mechanics. Here we report that thin films of hard electronic materials patterned in deterministic fractal motifs and bonded to elastomers enable unusual mechanics with important implications in stretchable device design. In particular, we demonstrate the utility of Peano, Greek cross, Vicsek and other fractal constructs to yield space-filling structures of electronic materials, including monocrystalline silicon, for electrophysiological sensors, precision monitors and actuators, and radio frequency antennas. These devices support conformal mounting on the skin and have unique properties such as invisibility under magnetic resonance imaging. The results suggest that fractal-based layouts represent important strategies for hard-soft materials integration.


Assuntos
Eletrônica , Fractais , Adulto , Epiderme , Humanos , Masculino , Mecânica , Adulto Jovem
8.
Adv Healthc Mater ; 3(10): 1597-607, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24668927

RESUMO

Non-invasive, biomedical devices have the potential to provide important, quantitative data for the assessment of skin diseases and wound healing. Traditional methods either rely on qualitative visual and tactile judgments of a professional and/or data obtained using instrumentation with forms that do not readily allow intimate integration with sensitive skin near a wound site. Here, an electronic sensor platform that can softly and reversibly laminate perilesionally at wounds to provide highly accurate, quantitative data of relevance to the management of surgical wound healing is reported. Clinical studies on patients using thermal sensors and actuators in fractal layouts provide precise time-dependent mapping of temperature and thermal conductivity of the skin near the wounds. Analytical and simulation results establish the fundamentals of the sensing modalities, the mechanics of the system, and strategies for optimized design. The use of this type of "epidermal" electronics system in a realistic clinical setting with human subjects establishes a set of practical procedures in disinfection, reuse, and protocols for quantitative measurement. The results have the potential to address important unmet needs in chronic wound management.


Assuntos
Eletrônica Médica/instrumentação , Monitorização Fisiológica/instrumentação , Cicatrização/fisiologia , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Silicones , Temperatura Cutânea/fisiologia , Fita Cirúrgica , Termografia/instrumentação
9.
Adv Mater ; 25(47): 6839-46, 2013 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-24327417

RESUMO

Thin, soft, and elastic electronics with physical properties well matched to the epidermis can be conformally and robustly integrated with the skin. Materials and optimized designs for such devices are presented for surface electromyography (sEMG). The findings enable sEMG from wide ranging areas of the body. The measurements have quality sufficient for advanced forms of human-machine interface.


Assuntos
Eletrônica , Epiderme/fisiologia , Eletromiografia , Epiderme/química , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA