Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Radiologe ; 49(1): 59-67, 2009 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-18597065

RESUMO

RATIONALE: The aim of the present study was to calculate the overall diagnostic accuracy of nuclear medical imaging in patients with painful knee arthroplasty. MATERIAL AND METHODS: This retrospective study of all patients (n=87) where a (99m)Tc-triple phase bone scintigraphy (TPBS; n=120) and (99m)Tc-anti-granulocyte scintigraphy (BW 250/183; n=20) for a painful knee arthroplasty was performed between 2003 and 2007. RESULTS: A total of 87 patients with 94 knee arthroplasties were examined to detect septic and aseptic loosening and to differentiate between them. The sensitivity, specificity, the positive and negative predictive value and accuracy of TPBS for the detection of septic knee arthroplasty loosening was 100%, 85%, 55%, 100%, 73% and for BW 250/183 was 91%, 66%, 76%, 85%, 80% for sepsis, respectively. A significant increase in diagnostic accuracy with 94%, 88%, 89%, 95% und 89% (p <0.001) could be achieved when both methods were used in combination. CONCLUSION: Both methods alone have high negative predictive values, but the combination of both is complementary and significantly increases the diagnostic accuracy and positive predictive value for final diagnosis of knee arthroplasty loosening.


Assuntos
Prótese do Joelho , Dor Pós-Operatória/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Falha de Prótese , Infecção da Ferida Cirúrgica/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais , Anticorpos Monoclonais Murinos , Criança , Difosfonatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos de Organotecnécio , Osteomielite/diagnóstico por imagem , Cintilografia , Estudos Retrospectivos , Sensibilidade e Especificidade , Tecnécio
2.
Sci Rep ; 6: 26886, 2016 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-27241616

RESUMO

In September and October 2015 widespread forest and peatland fires burned over large parts of maritime southeast Asia, most notably Indonesia, releasing large amounts of terrestrially-stored carbon into the atmosphere, primarily in the form of CO2, CO and CH4. With a mean emission rate of 11.3 Tg CO2 per day during Sept-Oct 2015, emissions from these fires exceeded the fossil fuel CO2 release rate of the European Union (EU28) (8.9 Tg CO2 per day). Although seasonal fires are a frequent occurrence in the human modified landscapes found in Indonesia, the extent of the 2015 fires was greatly inflated by an extended drought period associated with a strong El Niño. We estimate carbon emissions from the 2015 fires to be the largest seen in maritime southeast Asia since those associated with the record breaking El Niño of 1997. Compared to that event, a much better constrained regional total carbon emission estimate can be made for the 2015 fires through the use of present-day satellite observations of the fire's radiative power output and atmospheric CO concentrations, processed using the modelling and assimilation framework of the Copernicus Atmosphere Monitoring Service (CAMS) and combined with unique in situ smoke measurements made on Kalimantan.

3.
Am J Kidney Dis ; 34(1): 21-8, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10401011

RESUMO

The administration of parenteral iron dextran to hemodialysis patients is typically intermittent. We sought to determine the most appropriate intervals for sampling iron parameters during intermittent need-based and continuous maintenance regimens and to quantify differences in efficacy between such regimens during long-term therapy. After a single course of 10 consecutive 100-mg iron doses administered to 14 patients on 16 occasions, transferrin saturation (TSAT) and ferritin were unreliable indices of iron status for the next 2 and 6 weeks, respectively. TSAT and ferritin levels at 1 week were virtually identical to those at 2 weeks after the administration of a single 50-mg or 100-mg iron dextran dose to 16 other patients. Twelve patients on maintenance iron therapy (25 to 100 mg/wk; TSAT, 30% to 50%) had a statistically significant decrease in the amount of recombinant human erythropoietin (rHuEPO) needed to maintain hemoglobin (Hb) levels between 10 and 11 g/dL compared with 12 patients receiving intermittent need-based dosing, an effect that persisted from week 16 to week 72 of the study. Maintenance iron was feasible even in a third group of eight patients targeted to sustain an Hb level of 14 g/dL. In both iron maintenance groups, iron indices could be measured at weekly intervals, and ferritin levels did not progressively increase over time. Continuous maintenance iron dextran used to maintain TSATs of 30% to 50% significantly reduced rHuEPO requirements and resulted in no adverse side effects in chronic hemodialysis patients. After weekly maintenance 25- to 100-mg iron dextran doses, iron indices can be measured after 1 week; a delay of 2 weeks is not necessary.


Assuntos
Anemia Ferropriva/tratamento farmacológico , Complexo Ferro-Dextran/administração & dosagem , Falência Renal Crônica/complicações , Diálise Renal , Idoso , Anemia Ferropriva/etiologia , Esquema de Medicação , Eritropoetina/uso terapêutico , Feminino , Ferritinas/sangue , Hemoglobinas/metabolismo , Humanos , Injeções Intravenosas , Complexo Ferro-Dextran/uso terapêutico , Falência Renal Crônica/terapia , Masculino , Proteínas Recombinantes , Fatores de Tempo , Transferrina/metabolismo
4.
Rofo ; 167(4): 348-54, 1997 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-9417262

RESUMO

PURPOSE: To compare primary mammography diagnosis (ultrasound report available) with primary ultrasound diagnosis (mammography report available). METHODS: 89 preoperative patients with suspicious lesions were included. Mammography and ultrasound of all patients were evaluated by two independent experienced readers under clinical conditions. The reports of the complementary modality were available to both observers. Lesion evaluation was done on a per breast basis, in cases of multiple lesions in respect of the lesion with the greatest risk of malignancy. RESULTS: 39 benign and 59 malignant lesions were found. Primary mammography and primary ultrasound yielded 3 and 8 false positives and 10 and 13 false negatives. Concerning the palpable lesions (n = 59), primary mammography and primary ultrasound had no and 4 false positives and 7 and 8 false negatives, respectively, for the non palpable lesions, the figures were 3 and 4 false positive and 3 and 5 false negatives. CONCLUSIONS: Mammography remains the method of first choice in early detection of breast cancer, whereas breast ultrasound should be performed after and in knowledge of the mammogram, in consideration of the known indications (equivocal palpable lesion and mammographic opacity, dense breast).


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia , Ultrassonografia Mamária , Adolescente , Idoso , Doenças Mamárias/diagnóstico por imagem , Diagnóstico Diferencial , Estudos de Avaliação como Assunto , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
5.
Clin Nucl Med ; 28(4): 267-76, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12642703

RESUMO

PURPOSE: The aim of the current study was to determine the overall diagnostic accuracy of Tc-99m-labeled antigranulocyte monoclonal antibody Fab' fragments (LeukoScan) for the routine detection of bone and soft tissue infections in a retrospective evaluation. PATIENTS AND METHODS: 138 patients (63 men, 75 women; mean age, 58.29 +/- 25.38 years) with fever of unknown origin and possible endocarditis (n = 59), infection of arthroplastic joints (n = 20), arthritis (n = 16), peripheral (n = 15) and central bone infections (n = 14), soft tissue infection (n = 6), appendicitis (n = 4), pericarditis (n = 2), or vascular graft infection (n = 2) underwent imaging after injection of 555 to 925 MBq (15 to 25 mCi) Tc-99m-labeled antigranulocyte monoclonal antibody Fab' fragments (LeukoScan). RESULTS: True-positive results were found in 63 of 81 lesions. The overall sensitivity and specificity were 76% and 84%, respectively. In arthritis, seven of seven foci could be detected, whereas false-negative results were found in infections of the femoral bone in three of nine lesions and in periprosthetic infections of long bones in three of eight lesions. Good results were found in five of six soft-tissue infections, in four of six patients with endocarditis, in three of four atypical cases of appendicitis, in two of two infected vascular grafts, and in one of one patient with pericarditis. Subacute and chronic infections of the spine always showed photopenic areas in eight of eight patients. If photopenic lesions were included as diagnostic criteria, the sensitivity and specificity were 88% and 67%, respectively. CONCLUSIONS: Tc-99m-labeled antigranulocyte monoclonal antibody Fab' fragments can be used for imaging acute infections of peripheral bones and soft tissues. False-negative results are likely in patients with chronic infections. Sensitivity can be increased while decreasing specificity by including photopenic lesions in the spine as diagnostic criteria for localizing disease.


Assuntos
Anticorpos Monoclonais , Doenças Ósseas Infecciosas/diagnóstico por imagem , Endocardite/diagnóstico por imagem , Infecções dos Tecidos Moles/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais Murinos , Doenças Ósseas Infecciosas/complicações , Doenças Ósseas Infecciosas/diagnóstico , Endocardite/complicações , Endocardite/diagnóstico , Reações Falso-Negativas , Feminino , Febre de Causa Desconhecida/diagnóstico , Febre de Causa Desconhecida/diagnóstico por imagem , Febre de Causa Desconhecida/etiologia , Humanos , Infecções/diagnóstico , Infecções/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/complicações , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/diagnóstico por imagem , Cintilografia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Infecções dos Tecidos Moles/complicações , Infecções dos Tecidos Moles/diagnóstico
6.
Dtsch Med Wochenschr ; 133 Suppl 1: S15-8, 2008 May.
Artigo em Alemão | MEDLINE | ID: mdl-18437637

RESUMO

Magnetic resonance imaging (MRI) plays an important role in differentiating idiopathic Parkinson's disease (PD) from its atypical forms. Causes like chronic vascular disease and normal-pressure hydrocephalus are easily visualized. Furthermore, specific atrophy patterns can be found with multi-system atrophies, corticobasal degeneration and progressive supranuclear palsy. In addition the review also deals with specific imaging criteria of other neurodegenerative disorders, such as Wilson's disease, neurodegeneration with iron accumulation in the brain and Huntington's chorea. MRI is of minor importance for differentiating Alzheimer's disease from frontotemporal dementia or dementia with Lewy bodies. However, specific patterns are found in cerebral amyloid angiopathy and prion diseases..


Assuntos
Imageamento por Ressonância Magnética , Doenças Neurodegenerativas/diagnóstico , Gânglios da Base/irrigação sanguínea , Gânglios da Base/patologia , Infarto Encefálico/patologia , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/secundário , Cerebelo/patologia , Corpo Estriado/patologia , Demência/patologia , Diagnóstico Diferencial , Distúrbios Distônicos/patologia , Degeneração Hepatolenticular/patologia , Humanos , Doença de Huntington/patologia , Hidrocefalia de Pressão Normal/patologia , Doenças Neurodegenerativas/patologia , Doença de Parkinson/diagnóstico , Doença de Parkinson/patologia , Síndrome de Shy-Drager/patologia , Substância Negra/patologia , Paralisia Supranuclear Progressiva/patologia
7.
Dtsch Med Wochenschr ; 133 Suppl 1: S5-7, 2008 May.
Artigo em Alemão | MEDLINE | ID: mdl-18437639

RESUMO

Single photon emission computed tomography (SPECT) and positron emission tomography (PET) are important tools in the differential diagnosis and therapeutic monitoring of cognitive disorders. SPECT and PET are highly sensitive methods for the early diagnosis of underlying neurodegeneration and the functional changes in the basal ganglia. Early and reliable diagnosis will become even more relevant with the development of options in the causal treatment of dementias, which would exert their most beneficial effects well before the onset of clinical symptoms. This review provides a brief survey on currently available methods of nuclear imaging in cortical (Alzheimer's disease) and subcortical forms of neurodegenerative dementia (Parkinson's disease; dementia with Lewy bodies).


Assuntos
Doença de Alzheimer/diagnóstico , Doença por Corpos de Lewy/diagnóstico , Doença de Parkinson/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença de Alzheimer/fisiopatologia , Diagnóstico Diferencial , Humanos , Doença por Corpos de Lewy/fisiopatologia , Doença de Parkinson/fisiopatologia , Tomografia por Emissão de Pósitrons/tendências , Tomografia Computadorizada de Emissão de Fóton Único/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA