Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 205: 114300, 2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34365191

RESUMO

4'-(azidomethyl)-[1,1'-biphenyl]-2-carbonitrile (GTI-azide-1) and 5-(4'-(azidomethyl)-[1,1'-biphenyl]-2-yl)-1H-tetrazole (GTI-azide-2) are potentially genotoxic impurities that can be present at trace levels in the active pharmaceutical ingredients and drug products of sartans containing a tetrazole group. A method of high-performance liquid chromatography coupled with mass spectrometry, that allows the determination of those genotoxic impurities at sub-ppm level relative to the active pharmaceutical ingredient, was developed. The method utilises a very efficient liquid chromatograph Waters Acquity I-Class coupled with a highly sensitive tandem mass spectrometer Xevo TQ-XS. The separation was achieved on a column Acquity UPLC BEH Shield RP18 1.7 µm employing a linear elution gradient. The mass spectrometer was used with a heated electrospray ionization. The method was found to be sufficient in terms of sensitivity, linearity, precision, accuracy, selectivity and robustness and is easily applicable in the pharmaceutical quality control environment. The method allows for accurate quantification of both impurities GTI-azide-1 and GTI-azide-2 at levels below 1/10th of the specification limit, which is crucial in the context of pharmaceutical analysis. The limit of quantification was determined to be 0.033 ppm and 0.025 ppm for GTI-azide-1 and GTI-azide-2, respectively.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II , Preparações Farmacêuticas , Compostos de Bifenilo , Cromatografia Líquida de Alta Pressão , Dano ao DNA , Limite de Detecção , Reprodutibilidade dos Testes , Tetrazóis
2.
J Pharm Biomed Anal ; 195: 113877, 2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33422831

RESUMO

An effective analytical method for the quantification of N-nitrosodimethylamine (NDMA) using a liquid chromatography coupled with tandem mass spectrometry was developed and applied to a process optimization study of the production of metformin film coated tablets in order to identify the key factors behind the NDMA formation in metformin products. The method uses a linear gradient elution with mobile phases 0.1 % formic acid in water for chromatography and methanol for chromatography and a column Acquity UPLC HSS T3 1.8 µm. The use of the tandem mass spectrometry in a positive ion mode with an atmospheric pressure chemical ionization allows for the use of an isotopically labelled internal standard and an external calibration standard. The method was validated according to the guidelines of International Council for Harmonization in terms of limit of detection and quantification, linearity, precision, accuracy and method selectivity. To further justify the effectiveness of the method, a comparison between two laboratories was performed using a linear regression testing. Both methods give comparable results. 469 samples of both metformin active pharmaceutical ingredient and film coated tablets were analysed and the key factors behind NDMA formation were identified. Hypotheses explaining the mechanism were formulated and confronted with measurements and scientific literature. Protective measures to prevent NDMA contamination in metformin products were drawn.


Assuntos
Dimetilnitrosamina , Metformina , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Contaminação de Medicamentos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
3.
J Pharm Biomed Anal ; 162: 112-116, 2019 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-30236818

RESUMO

New unknown impurity at m/z 421.15 was observed during the accelerated stability analysis (40 °C/75% relative humidity) in the multi-component tablets of amlodipine besylate by reversed-phase ultra-high performance liquid chromatography-mass spectrometry (UHPLC-MS). UHPLC-MS and nuclear magnetic resonance (NMR) techniques were employed to identify and fully characterize the degradation compound. The degradation product was unambiguously identified as 3-ethyl 5-methyl 4-(2-chlorophenyl)-6-methyl-2-(morpholin-2-yl)-1,4-dihydropyridine-3,5-dicarboxylate and mechanism of its formation was proposed. It was confirmed that the degradation product was formed by the reaction of amlodipine with formaldehyde originating from the excipients present in the dosage form.


Assuntos
Anlodipino/química , Contaminação de Medicamentos , Química Farmacêutica/métodos , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Combinação de Medicamentos , Estabilidade de Medicamentos , Excipientes/química , Formaldeído/química , Hidroclorotiazida/química , Espectroscopia de Ressonância Magnética , Estrutura Molecular , Espectrometria de Massas por Ionização por Electrospray , Fatores de Tempo , Valsartana/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA