Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Blood Purif ; 47(1-3): 85-93, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30253381

RESUMO

The aim of this study was to primarily explore the relationship between free pentosidine and the fluorescence properties of spent dialysate, and also to develop a model to assess the levels of free pentosidine in spent dialysate based on the fluorescence measurements. First, 40 patients (20 females and 20 males) were examined during 40 dialysis sessions. High-pressure liquid chromatography (HPLC) was used to measure the free pentosidine concentrations from the spent dialysate. The full fluorescence spectra of the spent dialysates were recorded and single- and multi-wavelength (MW) models were developed. The average free pentosidine concentrations in the spent dialysate measured by HPLC at the start and end of the dialysis session were (mean ± SD) 4.25 ± 3.11 and 0.94 ± 0.69 µg/L respectively. The removal ratios (RRs) between RR_lab and RR_MW were statistically similar (p > 0.2). The concentration of free pentosidine and the RR can therefore be estimated from the spent dialysate when utilising fluorescence measurements.


Assuntos
Arginina/análogos & derivados , Soluções para Diálise/análise , Fluorescência , Lisina/análogos & derivados , Diálise Renal , Adulto , Idoso , Arginina/análise , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Lisina/análise , Masculino , Pessoa de Meia-Idade
2.
ASAIO J ; 66(6): 698-705, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31425267

RESUMO

In this study, simultaneous removal assessment of marker molecules from three uremic toxin groups was performed during different hemodialysis treatment modalities using optical characteristics of spent dialysate. Results from optical measurements were compared with the results from chemical laboratory. Ten chronic dialysis patients, mean age 59 ± 15 years, were included in the study during 40 hemodialysis sessions. Low-flux hemodialysis (HD), high-flux hemodialysis (HF), and postdilutional online hemodiafiltration (HDF) with different settings were used. The reduction ratio (RR) and total removed solute (TRS) of three uremic solutes were determined: small molecular weight urea, middle molecular ß2-microglobulin (B2M), and protein-bound indoxyl sulfate (IS). Concentrations of these solutes in the spent dialysate were measured by laboratory (lab) and optical (opt) methods, in the serum by laboratory methods, and calculated RR values in percentage were compared accordingly. Total removed solute was obtained from the total dialysate collection (TDC) using lab and opt methods. The highest RR values were found for urea and B2M, and the lowest for IS. The difference between RR of lab and opt results estimated as mean accuracy (BIAS) was ≤8.1% for all three solutes. Good correspondence between TRS lab vs. opt was achieved, resulting in strong linear correlation values R from 0.727 for urea to 0.971 for IS. Accuracy for TRS values as BIAS ± standard error (SE), comparing lab vs. opt, showed no statistical difference for any of the observed uremic solutes (P > 0.05). The accuracy of the optical method was not influenced by the dialysis modality (HD, HF, and HDF).


Assuntos
Soluções para Diálise/química , Indicã/análise , Diálise Renal , Análise Espectral/métodos , Ureia/análise , Microglobulina beta-2/análise , Adulto , Idoso , Feminino , Fluorescência , Humanos , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Diálise Renal/métodos
3.
PLoS One ; 11(9): e0162346, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27598005

RESUMO

AIM: In this work we estimated the contribution of the fluorescence of 4-pyridoxic acid (4-PA) to the total fluorescence of spent dialysate with the aim of evaluating the on-line monitoring of removal of this vitamin B-6 metabolite from the blood of patients with end-stage renal disease (ESRD). METHODS: Spectrofluorometric analysis of spent dialysate, collected from hemodialysis and hemodiafiltration sessions of 10 patients receiving regularly pyridoxine injections after dialysis treatment, was performed in the range of Ex/Em 220-500 nm. 4-PA in dialysate samples was identified and quantified using HPLC with fluorescent and MS/MS detection. RESULTS: Averaged HPLC chromatogram of spent dialysate had many peaks in the wavelength region of Ex320/Em430 nm where 4-PA was the highest peak with contribution of 42.2±17.0% at the beginning and 47.7±18.0% in the end of the dialysis. High correlation (R = 0.88-0.95) between 4-PA concentration and fluorescence intensity of spent dialysate was found in the region of Ex310-330/Em415-500 nm, respectively. CONCLUSION: 4-PA elimination from the blood of ESRD patients can be potentially followed using monitoring of the fluorescence of the spent dialysate during dialysis treatments.


Assuntos
Hemodiafiltração , Falência Renal Crônica/sangue , Ácido Piridóxico/sangue , Deficiência de Vitamina B 6/sangue , Vitamina B 6/sangue , Idoso , Biotransformação , Cromatografia Líquida de Alta Pressão , Soluções para Diálise , Feminino , Fluorescência , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Espectrometria de Fluorescência , Vitamina B 6/administração & dosagem , Vitamina B 6/farmacocinética , Deficiência de Vitamina B 6/complicações , Deficiência de Vitamina B 6/diagnóstico , Deficiência de Vitamina B 6/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA