1.
Eur Radiol ; 33(2): 1229-1242, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36029346

RESUMO

OBJECTIVES: Cardiac implantable electronic device (CIED)-induced metal artefacts possibly significantly diminish the diagnostic value of magnetic resonance imaging (MRI), particularly cardiac MR (CMR). Right-sided generator implantation, wideband late-gadolinium enhancement (LGE) technique and raising the ipsilateral arm to the generator during CMR scanning may reduce the CIED-induced image artefacts. We assessed the impact of generator location and the arm-raised imaging position on the CIED-induced artefacts in CMR. METHODS: We included all clinically indicated CMRs performed on patients with normal cardiac anatomy and a permanent CIED with endocardial pacing leads between November 2011 and October 2019 in our institution (n = 171). We analysed cine and LGE sequences using the American Heart Association 17-segment model for the presence of artefacts. RESULTS: Right-sided generator implantation and arm-raised imaging associated with a significantly increased number of artefact-free segments. In patients with a right-sided pacemaker, the median percentage of artefact-free segments in short-axis balanced steady-state free precession LGE was 93.8% (IQR 9.4%, n = 53) compared with 78.1% (IQR 20.3%, n = 58) for left-sided pacemaker (p < 0.001). In patients with a left-sided implantable cardioverter-defibrillator, the median percentage of artefact-free segments reached 87.5% (IQR 6.3%, n = 9) using arm-raised imaging, which fell to 62.5% (IQR 34.4%, n = 9) using arm-down imaging in spoiled gradient echo short-axis cine (p = 0.02). CONCLUSIONS: Arm-raised imaging represents a straightforward method to reduce CMR artefacts in patients with left-sided generators and can be used alongside other image quality improvement methods. Right-sided generator implantation could be considered in CIED patients requiring subsequent CMR imaging to ensure sufficient image quality. KEY POINTS: • Cardiac implantable electronic device (CIED)-induced metal artefacts may significantly diminish the diagnostic value of an MRI, particularly in cardiac MRIs. • Raising the ipsilateral arm relative to the CIED generator is a cost-free, straightforward method to significantly reduce CIED-induced artefacts on cardiac MRIs in patients with a left-sided generator. • Right-sided generator implantation reduces artefacts compared with left-sided implantation and could be considered in CIED patients requiring subsequent cardiac MRIs to ensure adequate image quality in the future.


Assuntos
Desfibriladores Implantáveis , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética/métodos
2.
Pacing Clin Electrophysiol ; 46(2): 125-131, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36402455

RESUMO

BACKGROUND: Many algorithms have been developed to ensure the safety and accuracy of cardiac implantable electric devices (CIED). A specific algorithm designed to prevent pacemaker induced tachycardia (PMT) after a premature ventricular complex (PVC response) is available in all Abbott (former St. Jude Medical) CIED. However, a few case reports suggest that this algorithm may be proarrhythmic when programmed to Atrial Pace (A-Pace on PVC). METHODS: We analyzed the data of all (n = 333) Abbot implantable cardioverter defibrillator (ICD) and cardiac resynchronization defibrillator (CRT-D) devices followed remote using the Merlin.net Patient Care Network in our institute in 2020. Status of the PVC response algorithm A-Pace on PVC or Off was collected, and all atrial mode switch (AMS) episodes longer than 30 s were thoroughly evaluated. Data on clinical characteristics of the patients was collect from the electronic patient records. RESULTS: A total of 173 patients had A-Pace on PVC and twenty-five of them (14%) had at least one atrial high rate episode (AHRE) >30 s (AHRE) triggered by the action of this algorithm. The median PVC count was higher in patients who had algorithm triggered AHRE than in those with no algorithm-triggered AHRE (1.7% [IQR 0-3.2] vs. 0% [IQR 0-1.1], p < .0001). The major clinical characteristics were comparable in the two groups. CONCLUSION: The A-Pace on PVC setting was frequently used in our patients. Our study shows that a considerable number of patients had at least one AHRE triggered by the algorithm. The use of this algorithm should be carefully reconsidered.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Átrios do Coração , Dispositivos de Terapia de Ressincronização Cardíaca
3.
Eur Radiol ; 32(6): 3830-3838, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34989847

RESUMO

OBJECTIVES: The European Society of Cardiology Guidelines on cardiac pacing from 2021 allow magnetic resonance imaging (MRI) in patients with cardiac implantable electronic devices (CIEDs) but do not recommend MRI in patients with epicardial pacing leads. The clinical dilemma remains whether performing an MRI in patients with CIED and epicardial leads is safe. We aimed to evaluate the safety of performing an MRI in patients with CIED and abandoned or functioning epicardial pacing leads. METHODS: We included all adult patients who underwent clinically indicated MRIs with CIED and functioning or abandoned epicardial leads in a single tertiary hospital between November 2011 and October 2019. The data were retrospectively collected. RESULTS: Twenty-six MRIs were performed on 17 patients with functioning or abandoned epicardial pacing leads. Sixty-nine percent of the MRI scans (18/26) were conducted on patients with functioning epicardial pacing leads. A definite adverse event occurred in one MRI scan. This was a transient elevation of the pacing threshold in a patient with a functioning epicardial ventricular pacing lead implanted 29 years previously. An irreversible atrial pacing lead impedance elevation was detected 6 months after the MRI in another patient; the association with the previous MRI remained unclear. No adverse events were detected in MRIs performed on patients with modern (implanted in 2000 or later) functioning epicardial leads. CONCLUSIONS: MRIs in patients with CIED and modern functioning epicardial pacing leads were performed without detectable adverse events. Further large-scale studies are necessary to confirm MRI safety in patients with epicardial pacing leads. KEY POINTS: • Currently, MRI in patients with cardiac implantable electronic devices (CIEDs) and functioning or abandoned epicardial pacing leads is not recommended. • MRIs in patients with CIED and modern functioning epicardial leads (implanted in 2000 or later) were performed without detectable adverse events in our patient cohort. • Allowing MRI in patients with epicardial pacing leads may significantly improve the diagnostic work-up, especially in specific patient groups, such as patients with congenital heart disease.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
4.
Ann Noninvasive Electrocardiol ; 20(5): 481-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25589197

RESUMO

BACKGROUND: Patients with diabetes mellitus (DM) have a higher risk of sudden cardiac death. Factors associated with the risk profiles of coronary artery disease (CAD) patients with DM are not well established. Heart rate turbulence (HRT) and T-wave alternans (TWA) are often used to predict arrhythmia events. METHODS AND RESULTS: HRT and TWA were measured in two independent groups: the ARTEMIS cohort study and the REFINE-ICD randomized trial. ARTEMIS assesses risk 3-12 months after coronary angiography in patients with CAD. The initial 1001 patients in ARTEMIS, 526 with and 475 without DM, are included in this analysis. REFINE-ICD compares usual care versus usual care plus ICD therapy in patients with left ventricular (LV) ejection fraction (EF) values of 36-50% assessed 2-15 months after myocardial infarction. The initial 275 patients screened in REFINE ICD are included in this analysis. Abnormal HRT plus TWA was more common in patients with versus without DM in ARTEMIS (125/526, 24% vs 63/475, 13%; P < 0.001) and REFINE-ICD (43/55, 78% vs 55/220, 25%; P < 0.001), respectively. Abnormal HRT plus TWA was also more common in patients with LVEF values < 50% (28%) vs ≥ 50% (18%; P < 0.001) in ARTEMIS and LVEF values below the population median of 42% (60/138, 43%) versus above the median (38/137, 28%; P < 0.01) in REFINE-ICD. CONCLUSIONS: Abnormal HRT plus TWA is more common in CAD patients with DM compared with the patients without DM and is related to the severity of LV dysfunction. CLINICAL TRIAL REGISTRATION INFORMATION: http://www.clinicaltrials.gov, NCT01426685; http://www.clinicaltrials.gov, NCT00673842.


Assuntos
Arritmias Cardíacas/fisiopatologia , Doença da Artéria Coronariana/fisiopatologia , Diabetes Mellitus Tipo 2/fisiopatologia , Eletrocardiografia Ambulatorial , Frequência Cardíaca/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Estudos de Coortes , Doença da Artéria Coronariana/etiologia , Diabetes Mellitus Tipo 2/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Disfunção Ventricular Esquerda/etiologia
5.
Artigo em Inglês | MEDLINE | ID: mdl-38914900

RESUMO

BACKGROUND: Chronotropic incompetence (CI) is common among elderly cardiac resynchronization therapy pacemaker (CRT-P) patients on optimal medical therapy. This study aimed to evaluate the impact of optimized rate-adaptive pacing utilizing the minute ventilation (MV) sensor on exercise tolerance. METHODS: In a prospective, multicenter study, older patients (median age 76 years) with a guideline-based indication for CRT were evaluated following CRT-P implantation. If there was no documented CI, requiring clinically rate-responsive pacing, the device was programmed DDD at pre-discharge. At 1 month, a 6-min walk test (6MWT) was conducted. If the maximum heart rate was < 100 bpm or < 80% of the age-predicted maximum, the response was considered CI. Patients with CI were programmed with DDDR. At 3 months post-implant, the 6MWT was repeated in the correct respective programming mode. In addition, heart rate score (HRSc, defined as the percentage of all sensed and paced atrial events in the single tallest 10 bpm histogram bin) was assessed at 1 and 3 months. RESULTS: CI was identified in 46/61 (75%) of patients without prior indication at enrollment. MV sensor-based DDDR mode increased heart rate in CI patients similarly to non-CI patients with intrinsically driven heart rates during 6MWT. Walking distance increased substantially with DDDR (349 ± 132 m vs. 376 ± 128 m at 1 and 3 months, respectively, p < 0.05). Furthermore, DDDR reduced HRSc by 14% (absolute reduction, p < 0.001) in those with more severe CI, i.e., HRSc ≥ 70%. CONCLUSION: Exercise tolerance in older CRT-P patients can be further improved by the utilization of an MV sensor.

6.
Eur Heart J Case Rep ; 7(11): ytad494, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37954565

RESUMO

Background: Edge-to-edge intervention is the most common trans-catheter procedure performed for isolated severe tricuspid regurgitation in high-surgical-risk patients. However, it creates an obstacle for future right ventricular (RV) procedures such as implantation of cardiac implantable electronic devices (CIEDs). Reports of the management of CIED implantation after tricuspid edge-to-edge therapy are scarce. Case summary: A 76-year-old woman suffered from severe tricuspid regurgitation with New York Heart Association three symptoms despite optimal medical therapy. After a thorough evaluation, the heart team recommended the TriClip procedure as the treatment of choice. However, 12 months after a successful TriClip procedure, rapid atrial fibrillation needed to be addressed with CIED implantation and atrioventricular (AV) node ablation. Pre-procedural planning included the intended posterior location of the CIED to avoid interference with the implanted clip and future AV node ablation. With an additional left ventricular lead positioned anteriorly to the RV lead, the posterior position of the RV lead was secured. Under peri-procedural trans-oesophageal echocardiography (TEE), the planned procedures were performed successfully. Discussion: A blind manoeuvring of the RV lead may damage the edge-to-edge tricuspid device. In addition, friction due to an overly close contract between the RV lead and the edge-to-edge device may damage the RV lead. A successful and safe CIED implantation and atrioventricular node ablation can be performed after tricuspid edge-to-edge therapy with careful planning and its precise execution under TEE surveillance.

10.
Circulation ; 108(17): 2107-12, 2003 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-14530200

RESUMO

BACKGROUND: Lipoprotein oxidation plays an important part in atherogenesis. Autoantibodies to oxidation-specific epitopes of LDL occur in plasma and atherosclerotic lesions of humans and animals. The potential role of these autoantibodies in atherogenesis still remains unsolved. We studied the relationship between different isotypes of autoantibodies to copper-oxidized LDL and malondialdehyde-modified LDL (MDA-LDL) and carotid artery intima-media thickness (IMT) in a population-based cohort of 1022 middle-aged men and women. In addition, we studied the relation of C-reactive protein (CRP) to IMT. METHODS AND RESULTS: The levels of IgM, IgG, and IgG2 autoantibodies binding to MDA-LDL and copper-oxidized LDL were determined in plasma samples by chemiluminescence-based ELISA. IMT and the number of plaques were measured ultrasonographically. The subjects were divided into tertiles for antibody titers. We found an inverse association between IMT and IgM autoantibody titers to MDA-LDL that remained statistically significant after adjusting for age, gender, LDL cholesterol, systolic blood pressure, CRP, and smoking. CRP was not independently associated with IMT. CONCLUSIONS: These results show that IgM autoantibodies to MDA-LDL have an inverse association with carotid atherosclerosis. The possible implications of this finding are discussed.


Assuntos
Autoanticorpos/sangue , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/imunologia , Imunoglobulina M/sangue , Lipoproteínas LDL/imunologia , Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/sangue , Doenças das Artérias Carótidas/epidemiologia , Feminino , Finlândia/epidemiologia , Humanos , Lipoproteínas LDL/sangue , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Túnica Íntima/diagnóstico por imagem , Túnica Média/diagnóstico por imagem , Ultrassonografia
11.
J Hypertens ; 20(12): 2371-8, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12473860

RESUMO

OBJECTIVE: Smoking is a risk factor for increased carotid artery intima-media thickness (IMT). The apolipoprotein E (apoE) 4 allele has been associated with cardiovascular diseases, but the role of apoE in regard to intima-media thickness (IMT) has remained controversial. The objective was to investigate whether there is some gene-environment interaction between smoking and apoE polymorphism. DESIGN Cross-sectional case-control study. METHODS: IMTs of 511 hypertensive and control men were measured ultrasonographically and the apoE genotypes were determined. Genotypes with the 4 allele were pooled into one group and the genotypes without it into another. RESULTS: A significant interaction between the 4 allele and smoking affecting IMT was observed among the hypertensive smokers, as assessed by analysis of covariance. The mean carotid IMT was significantly greater (1.01 versus 0.90 mm, P = 0.003) in the 4 carriers than in the subjects without 4 among the hypertensive smokers. The number of plaques was also significantly higher. No differences were found in the other subjects (hypertensive non-smokers or controls). Linear regression analysis indicated that the 4 allele was an independent determinant of IMT in the hypertensive smokers but not in the other subjects. The estimated average effect of the 4 allele on the mean IMT in the hypertensive smokers was 0.088 mm (P < 0.001). In the oldest age group, the interaction of smoking and 4 was also seen in the control subjects. CONCLUSION: The findings suggest that the 4 carriers are particularly susceptible to the atherogenic effects of smoking. This interaction is particularly clear in hypertensive subjects.


Assuntos
Apolipoproteínas E/genética , Doenças das Artérias Carótidas/etiologia , Hipertensão/genética , Arteriosclerose Intracraniana/etiologia , Polimorfismo Genético , Fumar/efeitos adversos , Adulto , Apolipoproteína E4 , Estudos de Casos e Controles , Estudos Transversais , Predisposição Genética para Doença , Heterozigoto , Humanos , Hipertensão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Túnica Íntima/diagnóstico por imagem , Túnica Média/diagnóstico por imagem , Ultrassonografia
12.
Eur J Cardiovasc Prev Rehabil ; 11(6): 511-2, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15580063

RESUMO

BACKGROUND: Paraoxonase-1 (PON1) is an enzyme that prevents low-density lipoprotein (LDL) oxidation. The role of polymorphisms of PON1 determining early atherosclerotic changes is currently unclear. DESIGN: Cross sectional cohort study. METHODS: Nine hundred and ninety-nine subjects from a population-based cohort were screened. Intima-media thickness (IMT) was measured by ultrasonography. Leu-Met55 and Gln-Arg192 polymorphism were determined. RESULTS: No association between PON1 genotypes and IMT was found. This finding remained after adjusting for confounding factors. CONCLUSIONS: The PON1 Leu-Met55 and Gln-Arg192 polymorphisms are not major risk factors for atherosclerosis in the general Caucasian population.


Assuntos
Arteriosclerose/genética , Arildialquilfosfatase/genética , Artéria Carótida Primitiva/patologia , Polimorfismo de Fragmento de Restrição , Arginina/genética , Arteriosclerose/patologia , Estudos de Casos e Controles , Estudos de Coortes , Estudos Transversais , Dipeptídeos/genética , Finlândia , Frequência do Gene , Genótipo , Glutamina/genética , Humanos , Hipertensão/epidemiologia , Reação em Cadeia da Polimerase , Sistema de Registros , Túnica Íntima/patologia , Túnica Média/patologia , População Branca/genética