Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 74(5): 1447-1455, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33940076

RESUMO

BACKGROUND: Thoracic endovascular aortic repair with a scallop design (scallop-TEVAR) is a useful treatment strategy to extend the proximal landing zone (PLZ), while maintaining perfusion to one or more of the supra-aortic trunks (SATs) when treating aortic pathology with an unfavorable PLZ. The durability of this approach with the Bolton Relay scallop endograft (Terumo Aortic, Sunrise, Fla) has not been established. METHODS: A retrospective review of prospectively collected data on consecutive patients that received scallop-TEVAR in zones 0 to 2 at a tertiary aortic unit was undertaken. The main outcome was durability, characterized by survival estimates, freedom from reintervention to the thoracic aorta and PLZ, migration and aneurysm sac regression. RESULTS: Between 2009 and 2019, 38 patients (71% male; median age, 70 years) underwent scallop-TEVAR for thoracic aortic pathology (n = 28, 74%) or as a part of thoracoabdominal aneurysm repair (n = 10 [26%]). The use of scallop-TEVAR significantly extended the PLZ (median, 5 mm preoperative PLZ vs 26 mm extended PLZ; P = .0001). A total of 41 SATs were perfused with a scallop, including the left subclavian artery (n = 25), left common carotid artery (n = 6), neo/innominate artery (n = 4), left subclavian artery, and vertebral artery (n = 1), innominate artery, and left common carotid artery (n = 2) in conjunction with 15 extra-anatomical bypasses. The PLZ was at Ishimaru zone 0 and 1 in 6 cases (16%), respectively, and zone 2 in 26 cases (68%). Technical success was 98%. The 30-day mortality was 5% (2/38; 1 death from myocardial infarction and 1 from multiorgan failure). A minor stroke occurred in three patients (8%) and temporary spinal cord ischemia in two patients (5%). The median follow-up was 4.5 years (range, 0-10.53 years) during which two patients (5%) developed type Ia endoleak and required intervention to the PLZ (one from device-related migration and one from disease progression). All-cause and aorta-related survival were 72% and 85% and freedom from thoracic and PLZ reintervention was 92% and 97%, respectively. There were no cases of early or late thoracic aortic rupture, retrograde type A aortic dissection or SAT occlusion. CONCLUSIONS: Scallop-TEVAR offers a less invasive treatment option to extend the seal zone in selected patients with an unfavorable PLZ, allowing for a durable repair in terms of overall survival and reintervention. Periprocedural stroke remains a principle concern.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Londres , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
J Vasc Surg ; 60(2): 330-6, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24767711

RESUMO

OBJECTIVE: Late thoracic aneurysms develop in 5% to 12% of patients having undergone open repair for coarctation of the aorta (CoA). We report our early results for thoracic endovascular aortic repair for pseudoaneurysms after CoA repair. METHODS: From 2008 to 2013, data regarding demographics, aneurysm morphology, procedure, and follow-up were collected prospectively on all patients treated for pseudoaneurysms after CoA repair. Retrospective analysis of identified patients was then performed. RESULTS: Thirteen patients (six men, seven women) were treated. Patients were a median age, 45 years (interquartile range (IQR), 39-56; range, 27-66 years, and the median time after CoA repair to aneurysm treatment was 34 years (IQR, 24-40 years). All patients had saccular pseudoaneurysms of the aortic arch, with a median aneurysm size of 4.1 cm (IQR, 3.4-5.1 cm). The left subclavian artery (LSCA) was involved in 10 patients and was occluded at presentation in three. Four patients had concurrent LSCA revascularization with carotid-subclavian bypass, one had aortic arch hybrid repair, and the LSCA was intentionally covered in two patients. Patients underwent thoracic endovascular aortic repair using the conformable TAG (6 of 13; W. L. Gore & Associates, Flagstaff, Ariz), Valiant device (4 of 13; Medtronic, Minneapolis, Minn), and a custom-made Relay endograft with LSCA scallop (4 of 13; Bolton Medical, Barcelona, Spain). Technical success was 100%, with satisfactory deployment of the stent grafts in all patients. There was no 30-day mortality, stroke, or paraplegia. Median follow-up was 15 months (IQR, 9-19 months; range, 1-67 months). Two type II endoleaks from an intercostal artery were managed conservatively, and one type Ib endoleak was treated successfully with distal stent extension. CONCLUSIONS: In this cohort, new-generation stent grafts have good early clinical and radiologic outcomes, avoiding the need for redo open surgery. Management of the LSCA can be tailored to individual patients with new stent graft technology. Long-term follow-up of these patients is crucial to understanding whether endovascular management of this cohort is acceptable.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Coartação Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Adulto , Falso Aneurisma/diagnóstico , Falso Aneurisma/etiologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/etiologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
J Vasc Surg ; 60(6): 1499-506, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25264365

RESUMO

BACKGROUND: The suitability of the proximal landing zone remains one of the main limitations to thoracic endovascular aortic repair (TEVAR). The advent of custom-made scalloped stent grafts widens the endovascular options for patients with challenging anatomy. The objective of this study was to present our early and midterm results of custom-made scalloped thoracic stent grafts. METHODS: Prospectively acquired data relating to patient demographics, procedure details, clinical outcome, and complications were analyzed. In addition, we analyzed preoperative and postoperative computed tomography scans to evaluate aneurysm morphology, graft placement, side-vessel patency, and endoleaks. RESULTS: Twenty-one patients with a median age of 71 years (range, 35-81 years) underwent custom-made scalloped TEVAR, eight of whom had a concomitant hybrid repair. Procedural success was achieved in all cases. Proximal seal was achieved in all cases, with no type I endoleaks. There were no cases of retrograde dissection and no conversions to open repair. The median follow-up period was 36 weeks (range, 3-183 weeks). Two patients died in the hospital. Three patients suffered a stroke. Three patients had a type II endoleak, one of whom had significant sac enlargement requiring reintervention. One patient had a type III endoleak requiring reintervention. There were no cases of graft migration. CONCLUSIONS: Our midterm results show that custom-made scalloped TEVAR is an acceptable treatment of thoracic aortic aneurysms with a short proximal landing zone. Longer term outcome data are required to establish wider use of scalloped thoracic endografts.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
Ann Vasc Surg ; 28(4): 1031.e7-1031.e10, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24184462

RESUMO

Primary mycotic aneurysms of the aorta are a rare but life-threatening condition. A 59-year-old woman developed a back abscess secondary to an insect bite. A computed tomography scan revealed 3 concomitant mycotic aneurysms, including a rupture. Staged repair was undertaken: immediate open repair for contained rupture of a type IV thoracoabdominal aortic aneurysm, followed by endovascular repair of a descending thoracic aneurysm 3 weeks later and finally an aortic arch hybrid repair of a left subclavian artery aneurysm 16 months later. She remains well postoperatively. There is currently no consensus on the timing of repair or modality of treatment of mycotic aneurysms. Each patient should be treated individually based on aneurysm location, rupture, and comorbidities, as shown by this case.


Assuntos
Aneurisma Infectado/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/cirurgia , Infecções por Bacteroidaceae/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Mordeduras e Picadas de Insetos/complicações , Infecções Pneumocócicas/cirurgia , Prevotella/isolamento & purificação , Streptococcus pneumoniae/isolamento & purificação , Aneurisma Infectado/diagnóstico , Aneurisma Infectado/microbiologia , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/microbiologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/microbiologia , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/microbiologia , Aortografia/métodos , Infecções por Bacteroidaceae/diagnóstico , Infecções por Bacteroidaceae/microbiologia , Feminino , Humanos , Pessoa de Meia-Idade , Infecções Pneumocócicas/diagnóstico , Infecções Pneumocócicas/microbiologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Cardiovasc Intervent Radiol ; 47(1): 26-35, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38030849

RESUMO

BACKGROUND: Endovascular treatment of visceral and renal artery aneurysms and pseudoaneurysms is an effective, minimally invasive treatment that has been successfully used since the early 1990s, with refined and expanded techniques and tools currently offering excellent outcomes. Due to increased detection of such lesions in recent years, many of which are asymptomatic, revision of the indications for intervention and the correct endovascular treatment approaches has become essential. PURPOSE: This document will presume that the indication for treatment is clear and approved by the multidisciplinary team and will define the standards required for the performance of each intervention, as well as their relative advantages and limitations. CIRSE Standards of Practice documents are not intended to impose a standard of clinical patient care, but recommend a reasonable approach to, and best practices for, the performance of the endovascular treatment of visceral and renal artery aneurysms and pseudoaneurysms. METHODS: The writing group was established by the CIRSE Standards of Practice Committee and consisted of five clinicians with internationally recognised expertise in endovascular treatments. The writing group reviewed the existing literature on visceral and renal artery aneurysms and pseudoaneurysms, performing an evidence search using PubMed to identify publications in English and relating to human subjects from 1990 to 2022. The final recommendations were formulated through consensus. RESULTS: Endovascular treatment has an established role in the successful management of visceral and renal artery aneurysms and pseudoaneurysms, and this Standards of Practice document provides up-to-date recommendations for its safe performance.


Assuntos
Falso Aneurisma , Aneurisma , Embolização Terapêutica , Procedimentos Endovasculares , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Artéria Renal/diagnóstico por imagem , Artéria Renal/cirurgia , Procedimentos Endovasculares/métodos , Embolização Terapêutica/métodos , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Resultado do Tratamento
7.
Injury ; : 111760, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39138029

RESUMO

OBJECTIVE: The primary objective of this study is to assess common sites of injury and the associated imaging findings in penetrating injuries. We pay particular attention to gluteal, anterior abdominal wall and junctional zone injuries. The aim is to highlight areas of diagnostic uncertainty and discrepancy between imaging and surgical findings, to improve review areas in trauma reporting. METHODS: A retrospective, observational study reviewing all paediatric admissions to the emergency department of a major trauma Centre with a penetrating injury, from 2015 to 2019. RESULTS: Gluteal penetrating injuries are by far the most commonly sustained injury in the adolescent population, making up over 1/3 of cases. The vast majority of these cases sustained superficial injuries or shallow intramuscular haematomas, however in a small group (15%), serious vascular or rectal injuries were demonstrated on dual phase CT, requiring emergent surgical or endovascular treatment. Penetrating injuries to the anterior abdominal wall and junctional zone are less common but are associated with higher morbidity, with 43% of cases demonstrating solid organ or bowel injury. These cases also lead to an increased degree of diagnostic uncertainty. CONCLUSION: Gluteal injuries are common and although the overall morbidity of these cases is low, these patients are at risk of serious and life threatening consequences such as vascular and rectal injury and it is imperative that these complications are considered and ruled out via dual phase CT or direct visualization. Anterior abdominal wall and junctional zone injuries are less common, but lead to greater morbidity and also greater diagnostic uncertainty. The use of other salient findings as described in this report can aid diagnostic accuracy and reduce discrepancies.

8.
CVIR Endovasc ; 6(1): 25, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37076700

RESUMO

Pelvic venous congestion syndrome (PVCS) is a common, but underdiagnosed, cause of chronic pelvic pain (CPP) in women.PVCS occurs usually, but not exclusively, in multiparous women. It is characterized by chronic pelvic pain of more than six months duration with no evidence of inflammatory disease.The patients present to general practitioners, gynaecologists, vascular specialists, pain specialists, gastroenterologists and psychiatrists. Pain of variable intensity occurs at any time but is worse in the pre-menstrual period, and is exacerbated by walking, standing, and fatigue. Post coital ache, dysmenorrhea, dyspareunia, bladder irritability and rectal discomfort are also common. Under-diagnosis of this condition can lead to anxiety and depression.A multidisciplinary approach in the investigation and management of these women is vital.Non-invasive imaging (US, CT, MRI) are essential in the diagnosis and exclusion of other conditions that cause CPP as well in the definitive diagnosis of PVCS. Trans-catheter venography remains the gold standard modality for the definitive diagnosis and is undertaken as an immediate precursor to ovarian vein embolization (OVE). Conservative, medical and surgical management strategies have been reported but have been superseded by OVE, which has a reported technical success rates of 96-100%, low complication rates and long-term symptomatic relief in between 70-90% of cases.The condition, described in this paper as PVCS, is referred to by a wide variety of other terms in the literature, a cause of confusion.There is a significant body of literature describing the syndrome and the excellent outcomes following OVE however the lack of prospective, multicentre randomized controlled trials for both investigation and management of PVCS is a significant barrier to the complete acceptance of both the existence, investigation and management of the condition.

9.
Cardiovasc Intervent Radiol ; 46(3): 302-309, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36705706

RESUMO

This CIRSE Standards of Practice document is aimed at healthcare professionals (including interventional radiologists) performing endovascular procedures to provide best practices for performing arterial access for interventions. It has been developed by an expert writing group under the guidance of the CIRSE Standards of Practice Committee. This paper encompasses up-to-date clinical and technical aspects in performing safe and appropriate arterial access for interventions.


Assuntos
Artérias , Procedimentos Endovasculares , Humanos
10.
Radiology ; 264(2): 473-83, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22668564

RESUMO

PURPOSE: To determine the type and frequency of errors during vascular interventional radiology (VIR) and design and implement an intervention to reduce error and improve efficiency in this setting. MATERIALS AND METHODS: Ethical guidance was sought from the Research Services Department at Imperial College London. Informed consent was not obtained. Field notes were recorded during 55 VIR procedures by a single observer. Two blinded assessors identified failures from field notes and categorized them into one or more errors by using a 22-part classification system. The potential to cause harm, disruption to procedural flow, and preventability of each failure was determined. A preprocedural team rehearsal (PPTR) was then designed and implemented to target frequent preventable potential failures. Thirty-three procedures were observed subsequently to determine the efficacy of the PPTR. Nonparametric statistical analysis was used to determine the effect of intervention on potential failure rates, potential to cause harm and procedural flow disruption scores (Mann-Whitney U test), and number of preventable failures (Fisher exact test). RESULTS: Before intervention, 1197 potential failures were recorded, of which 54.6% were preventable. A total of 2040 errors were deemed to have occurred to produce these failures. Planning error (19.7%), staff absence (16.2%), equipment unavailability (12.2%), communication error (11.2%), and lack of safety consciousness (6.1%) were the most frequent errors, accounting for 65.4% of the total. After intervention, 352 potential failures were recorded. Classification resulted in 477 errors. Preventable failures decreased from 54.6% to 27.3% (P < .001) with implementation of PPTR. Potential failure rates per hour decreased from 18.8 to 9.2 (P < .001), with no increase in potential to cause harm or procedural flow disruption per failure. CONCLUSION: Failures during VIR procedures are largely because of ineffective planning, communication error, and equipment difficulties, rather than a result of technical or patient-related issues. Many of these potential failures are preventable. A PPTR is an effective means of targeting frequent preventable failures, reducing procedural delays and improving patient safety.


Assuntos
Erros Médicos/prevenção & controle , Equipe de Assistência ao Paciente/organização & administração , Radiografia Intervencionista/métodos , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/terapia , Eficiência , Feminino , Humanos , Masculino , Segurança do Paciente , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento
11.
J Vasc Surg ; 56(6): 1731-3, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23089303

RESUMO

A 73-year-old man developed type I and III endoleaks from a fractured right renal stent with downward migration of a fenestrated endograft, 6 years after endovascular repair of a juxtarenal aneurysm. Endovascular treatment attempts were unsuccessful. He underwent aortic debranching and antegrade visceral artery revascularization via a left thoracolaparotomy incision and an extraperitoneal approach to the visceral aorta. An antegrade aortic stent covered the endoleak, with technical and clinical success at 9 months. Failure of complex endografts presents particular problems, potentially not amenable to totally endovascular repair. Continued surveillance is mandated as late, asymptomatic sac expansion can occur.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Stents/efeitos adversos , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico , Endoleak/diagnóstico , Endoleak/etiologia , Humanos , Masculino , Falha de Prótese/efeitos adversos
12.
J Endovasc Ther ; 18(2): 243-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21521066

RESUMO

PURPOSE: To evaluate the feasibility and safety of a redesigned remotely operated vascular catheter versus manual catheter manipulation in a porcine model. METHODS: Following femoral artery puncture and wire insertion, 4 pigs had either a robotically steered catheter (3 animals) or standard manual catheter manipulation to cannulate the contralateral iliac artery, bilateral renal arteries, and the superior mesenteric artery. After harvesting, the vessels were evaluated histologically by an independent laboratory using hematoxylin and eosin staining. Each cannulated artery was assessed for disruption of the intimal surface, intimal thrombus, damage to the tunica muscularis (dissection), mural hemorrhage, and inflammation by a pathologist who was blinded to the technique utilized for cannulation. RESULTS: No histological evidence of intimal thrombus, disruption, inflammation, or hemorrhage was demonstrated in any vessel section from the robotic cases. In the SMA, 1 of 61 sections from the robotic cases demonstrated mild focal dissection, while 1 of 9 slices from the manual control showed intimal thrombus. Of 129 slices from the renal arteries catheterized by the robotic system, 4 sections demonstrated mild focal dissection, while 2 of 23 sections from the manual control showed grade 1 intimal thrombus. In the iliofemoral arteries, 3 of 91 sections showed mild focal dissection in the robotic cases; in the manual control, 1 of 9 slices demonstrated extensive dissection and another showed mild intimal thrombus. CONCLUSION: The robotically operated catheter was at least as safe as manual manipulation. More extensive injury was actually observed with the manual technique. This newly designed robotic catheter has the potential to offer many advantages in terms of flexibility and range of motion.


Assuntos
Catéteres , Procedimentos Endovasculares/instrumentação , Robótica , Cirurgia Assistida por Computador/instrumentação , Angiografia Digital , Animais , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Artéria Ilíaca/lesões , Artéria Mesentérica Superior/lesões , Modelos Animais , Artéria Renal/lesões , Medição de Risco , Cirurgia Assistida por Computador/efeitos adversos , Suínos , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/patologia , Lesões do Sistema Vascular/prevenção & controle
13.
CVIR Endovasc ; 4(1): 81, 2021 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-34854997

RESUMO

INTRODUCTION: During subintimal angioplasty (SIA), it is not always possible to re-enter the vessel lumen due to a variety of factors. Recanalization using hydrophilic wires and catheters alone, apart from its potential technical failure, is also limited by minimal control over the re-entry point. This is frequently well beyond the point of occlusion, thus often compromising important collaterals. In order to bypass the obstruction and attain controlled re-entry into the lumen of the diseased vessel, a re-entry device (RED) may be required. This paper assesses our centre's experience with the safety and efficacy of the Pioneer re-entry system and systematically reviews the pertinent literature. METHOD: A single centre retrospective study of subintimal angioplasty involving the use of the Pioneer Plus intravascular guided reentry catheter was performed. Patient demographics including age, gender, risk factors, comorbidities clinical indication and complications were recorded. Lesion characteristics, including location and severity of calcification were also assessed. A systematic literature review of all reported studies where the Pioneer RED was used for iliac and lower limb revascularization was conducted by 2 of the authors using the PubMed (MEDLINE) and EMBASE databases. RESULTS: The study comprised 30 cases. Technical success was 97%. A small, quickly resolved extravasation was the only device related complication. These results are in line with the systematic review which identified 16 studies using the Pioneer RED, reporting a technical success rate of 87.4-100% (median = 100%) and complication rate of 0-25.8% (median = 0%). However, due to heterogeneity in definitions of technical success, data was not pooled.

14.
Br J Radiol ; 94(1119): 20200530, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33095656

RESUMO

A variety of different external and internal medical devices are used in the acute setting to maintain life support and manage severely injured and unstable trauma or emergency patients. These devices are inserted into the acutely ill patient with the specific purpose of improving outcome, but misplacement can cause additional morbidity and mortality. Consequently, meaningful interpretation of the position of devices can affect acute management. Some devices such as nasopharyngeal, nasogastric and endotracheal tubes and chest and surgical drains are well known to most clinicians, however, little formal training exists for radiologists in composing their report on the imaging of these devices. The novice radiologist often relies on tips and phrases handed down in an aural tradition or resorts to phrases such as: "position as shown". Furthermore, radiologists with limited experience in trauma might not be familiar with the radiological appearance of other more specific devices. This review will focus on the most common medical devices used in acute trauma patients, indications, radiological appearance and their correct and suboptimal positioning.


Assuntos
Serviços Médicos de Emergência/métodos , Serviço Hospitalar de Emergência , Equipamentos e Provisões , Radiologia/métodos , Ferimentos e Lesões/terapia , Humanos , Radiologistas , Equipamentos Cirúrgicos
15.
Trauma Surg Acute Care Open ; 6(1): e000727, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34395917

RESUMO

BACKGROUND: Penetrating gluteal injuries (PGIs) are an increasingly common presentation to major trauma centers (MTCs) in the UK and especially in London. PGIs can be associated with mortality and significant morbidity. There is a paucity of consistent guidance on how best to investigate and manage these patients. METHODS: A retrospective cohort study was performed by interrogating prospectively collected patient records for PGI presenting to a level 1 MTC in London between 2017 and 2019. RESULTS: There were 125 presentations with PGI, accounting for 6.86% of all penetrating injuries. Of these, 95.2% (119) were male, with a median age of 21 (IQR 18-29), and 20.80% (26) were under 18. Compared with the 3 years prior to this study, the number of PGI increased by 87%. The absolute risk (AR) of injury to a significant structure was 27.20%; the most frequently injured structure was a blood vessel (17.60%), followed by the rectum (4.80%) and the urethra (1.60%). The AR by anatomic quadrant of injury was highest in the lower inner quadrant (56%) and lowest in the upper outer quadrant (14%). CT scanning had an overall sensitivity of 50% and specificity of 92.38% in identifying rectal injury. DISCUSSION: The anatomic quadrant of injury can be helpful in stratifying risk of rectal and urethral injuries when assessing a patient in the emergency department. Given the low sensitivity in identifying rectal injury on initial CT, this data supports assesing any patients considered at high risk of rectal injury with an examination under general anesthetic with or without rigid sigmoidoscopy. The pathway has created a clear tool that optimizes investigation and treatment, minimizing the likelihood of missed injury or unnecessary use of resources. It therefore represents a potential pathway other centers receiving a similar trauma burden could consider adopting. LEVEL OF EVIDENCE: 2b.

16.
CVIR Endovasc ; 6(1): 30, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37193940
17.
Br J Radiol ; 91(1089): 20180130, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29644869

RESUMO

Blunt thoracic aortic injury (TAI) occurs most frequently as a sequelae of high impact deceleration such as high-velocity road traffic accidents and falls from height. The burden of mortality and morbidity is high, however advances in pre-hospital care, diagnostic imaging and endovascular therapies have improved outcomes in this group of patients. Emergent treatment depends on accurate, early diagnosis by the radiologist. It is therefore of paramount importance that radiologists are familiar with both the direct (intimal flap, pseudoaneurysm, aortic contour irregularity and contrast extravasation) and indirect (periaortic haematoma) imaging findings of TAI. Furthermore, it is critical that technical (breathing artefact and cardiac motion artefact) as well as anatomical (ductus diverticulum, aortic spindle and mediastinal structures which imitate periaortic haematoma) pitfalls are recognised to avoid misdiagnosis. This pictorial review will help the diagnostic radiologist to recognise the patterns of injury and imaging features associated with TAI, as well as highlighting potential mimics when interrogating CTangiography (CTA) in major trauma.


Assuntos
Aorta Torácica/lesões , Lesões do Sistema Vascular/diagnóstico por imagem , Ferimentos não Penetrantes/diagnóstico por imagem , Adulto , Idoso , Falso Aneurisma/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Lesões do Sistema Vascular/classificação
18.
Br J Radiol ; 91(1087): 20170739, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29509505

RESUMO

Major Trauma Centres and Emergency Departments are treating an increasing number of elderly trauma patients in the UK. Elderly patients, defined as those over the age of 65 years, are more susceptible to injury from lesser mechanisms of trauma than younger adults. The number of elderly trauma cases is rising yearly, accounting for >25% of all major trauma nationally. The elderly have different physiological reserves and a different response to trauma due to premorbid frailty, co-existing conditions and prescribed medication. These factors need to be appreciated in trauma triaging, radiological assessment and clinical management. A lower threshold for trauma-call activation is recommended, including a lower threshold for advanced imaging. We will review general principles of trauma in the elderly, outline injury patterns in this age group and illustrate the radiological features per anatomical site, from head to pelvis and the extremities. We advocate using contrast-enhanced computed tomography as the primary diagnostic imaging modality as concern about intravenous contrast agent-induced nephropathy is relatively minor. Prompt investigation and diagnosis leads to timely appropriate treatment, therefore the radiologist can discerningly improve morbidity and mortality in this vulnerable group.


Assuntos
Tomografia Computadorizada por Raios X , Centros de Traumatologia/organização & administração , Ferimentos e Lesões/diagnóstico por imagem , Idoso , Meios de Contraste , Humanos , Triagem
19.
Br J Radiol ; 89(1061): 20150819, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26693970

RESUMO

25 years ago, on a Friday evening at 9 pm, the emergency department (ED) was full of patients with a wide range of clinical problems. Their investigations included plain radiographs, but no other imaging was included until the next working day. At present, many patients are receiving advanced imaging such as ultrasound, CT and MRI, often delivered out of hours--an obvious advance for patients or sometimes an unnecessary development? In this article, we will consider how to assess patient benefits and whether increased use of advanced imaging is an overall advance for patients. We will address the general implications for healthcare services which come with greater use of advanced imaging. We will then address the effect of advanced imaging on individual fictional ED patients with a variety of complaints.


Assuntos
Diagnóstico por Imagem/economia , Diagnóstico por Imagem/estatística & dados numéricos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Pesquisas sobre Atenção à Saúde/estatística & dados numéricos , Diagnóstico por Imagem/métodos , Serviço Hospitalar de Emergência/economia , Humanos , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/estatística & dados numéricos , Risco , Tomografia Computadorizada por Raios X/economia , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Ultrassonografia/economia , Ultrassonografia/estatística & dados numéricos
20.
Br J Radiol ; 89(1063): 20160160, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27187601

RESUMO

OBJECTIVE: To compare the image quality of conventional arterial and portal venous (PV) phase multidetector CT (MDCT) with two biphasic injection protocols in polytrauma patients. METHODS: 60 consecutive patients with polytrauma underwent body 256-slice MDCT with a conventional protocol or 1 of 2 single-pass biphasic protocols: Group A, arterial (30 s) and PV (60 s) phase acquisitions; Group B, "biphasic" contrast injection with a single acquisition at 60 s; and Group C, "modified biphasic" injection with a single acquisition at a 70-s delay. Images were analyzed for arterial, venous and parenchymal attenuation profiles with regions of interest in the major arteries, veins and solid abdominal organs. A 5-point scoring system was used to assess the image quality, with 5 representing excellent arterial, venous and parenchymal opacification and <3 representing non-diagnostic opacification. In addition, the effective dose (millisieverts) was compared between the groups. RESULTS: In 93% of patients, image quality was scored as good or excellent (≥4). All studies were of satisfactory diagnostic quality. Overall, venous and arterial attenuation profiles were comparable. Attenuation profiles in the solid abdominal viscera were significantly higher (p < 0.01) using both biphasic protocols than with arterial or PV phase of conventional protocols. Effective doses were higher in Group A. CONCLUSION: Comparable image quality can be achieved using a biphasic i.v. contrast injection protocol with single MDCT acquisition with less radiation and reduction in acquisition time. ADVANCES IN KNOWLEDGE: For these particular biphasic injection protocols, we have shown that image quality is comparable with a conventional protocol. This has been achieved by comparing enhanced densities of specific structures, as well as gestalt scoring by assessors, on a 256-slice MDCT.


Assuntos
Meios de Contraste/administração & dosagem , Tomografia Computadorizada Multidetectores/métodos , Traumatismo Múltiplo/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Imagem Corporal Total/métodos , Adulto , Feminino , Humanos , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA