Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Breast Cancer Res Treat ; 202(1): 33-43, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37490172

RESUMO

PURPOSE: The key problem raised in the paper is the change in the position of the breast tumor due to magnetic resonance imaging examinations in the abdominal position relative to the supine position during the surgical procedure. Changing the position of the patient leads to significant deformation of the breast, which leads to the inability to indicate the location of the neoplastic lesion correctly. METHODS: This study outlines a methodological process for treating cancer patients. Pre-qualification assessments are conducted for magnetic resonance imaging (MRI), and 3D scans are taken in three positions: supine with arms raised, supine surgical position (SS), and standing. MRI and standard ultrasonography (USG) imaging are performed, and breast and cancer tissue are segmented from the MRI images. Finite element analysis is used to simulate tissue behavior in different positions, and an artificial neural network is trained to predict tumor dislocation. Based on the model, a 3D-printed breast with a highlighted tumor is manufactured. This computer-aided analysis is used to create a detailed surgical plan, and lumpectomy surgery is performed in the SS. In addition, the geometry of the tumor is presented to the medical staff as a 3D-printed element. RESULTS: By utilizing a comprehensive range of techniques, including pre-qualification assessment, 3D scanning, MRI and USG imaging, segmentation of breast and cancer tissue, model analysis, image fusion, finite element analysis, artificial neural network training, and additive manufacturing, a detailed surgical plan can be created for performing lumpectomy surgery in the supine surgical position. CONCLUSION: The new approach developed for the pre-operative assessment and surgical planning of breast cancer patients has demonstrated significant potential for improving the accuracy and efficacy of surgical procedures. This procedure may also help the pathomorphological justification. Moreover, transparent 3D-printed breast models can benefit breast cancer operation assistance. The physical and computational models can help surgeons visualize the breast and the tumor more accurately and detailedly, allowing them to plan the surgery with greater precision and accuracy.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Inteligência Artificial , Mama/patologia , Mastectomia Segmentar , Ultrassonografia , Imageamento por Ressonância Magnética/métodos
2.
J Endovasc Ther ; : 15266028231180350, 2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37309126

RESUMO

PURPOSE: The covered endovascular reconstruction of the aortic bifurcation (CERAB) technique offers an alternative for Trans-Atlantic Inter-Society Consensus (TASC) C/D lesions involving the aortic bifurcation. The study aims to evaluate the outcomes of the CERAB technique for extensive aortoiliac occlusive disease (AIOD) using the BeGraft balloon-expandable covered stent (BECS). MATERIALS AND METHODS: This is a physician-initiated, multicenter, retrospective, observational study. Between June 2017 and June 2021, all consecutive patients who underwent the CERAB procedure using the BeGraft stent (Bentley InnoMed, Hechingen, Germany) in 3 clinics were enrolled. Patients' demographics, lesion characteristics, and procedural results were collected and retrospectively analyzed. Follow-up was done at 1, 6, and 12 months and then annually with clinical examination, ankle-brachial index (ABI), and duplex ultrasound. The primary endpoint was the patency at 12 months. Secondary endpoints included procedural-related complications, secondary patency, freedom from target lesion revascularization (TLR), and clinical improvement. RESULTS: In all, 120 patients (64 men) with a median age of 65 years (range: 34-84 years) were analyzed. Most patients had extensive AIOD classified as TASC II C (n=32; 26.7%) or TASC II D (n=81; 67.5%). The median duration of the procedure was 120 minutes (interquartile range [IQR]: 80-180 minutes). All 454 BeGraft stents (137 aortic and 317 peripheral) were successfully delivered and deployed. The overall procedural complication rate was 14 (11.7%). The median hospital length of stay was 5 days (IQR: 3-6 days). All patients improved clinically, and the ABI increased significantly (p<0.05). The median follow-up was 19 months (range: 6-56 months). The primary patency rate, secondary patency rate, and freedom from TLR at 12 months were 94.5%, 97.3%, and 93.5%, respectively. CONCLUSIONS: The CERAB procedure with BeGraft BECSs has a high technical success rate, favorable patency outcomes, and low morbidity, even in relatively ill patients with extensive AIOD. Prospective randomized studies on the CERAB technique are definitely recommended. CLINICAL IMPACT: This study evaluates the outcomes of BeGraft stents used during the covered endovascular reconstruction of the aortic bifurcation (CERAB) procedure. To date, several balloon-expandable covered stents have been used for this technique with satisfactory results. This study showed the safety and excellent patency of the CERAB technique in extensive AIOD using BeGraft balloon-expandable covered stents.

3.
Zentralbl Chir ; 2023 May 30.
Artigo em Alemão | MEDLINE | ID: mdl-37253376

RESUMO

There are many publications dealing with treatment options for uncomplicated type B aortic dissection (TBAD). Early TEVAR (Thoracic Endovascular Aortic Repair) may improve aortic-specific survival and delay disease progression in the long-term. Especially in patients with uncomplicated TBAD and additional high-risk features, preemptive TEVAR may improve late outcomes.We conducted a retrospective analysis of all patients treated for TBAD in our hospital between February 2017 and September 2021. Comorbidities, intraoperative data, 30-day mortality and postprocedural complications were analysed.During the above-mentioned period, 61 patients (38 males, median age 63 years) with TBAD were treated. Six patients received best medical treatment (BMT). 55 patients were treated by TEVAR and BMT. 11 patients (20%) had complicated TBAD, 12 patients (22%) had uncomplicated TBAD with high-risk features and 32 patients (58%) had uncomplicated TBAD. Technical success was 100%. No patient with uncomplicated TBAD died within the first 30 postoperative days. One patient with uncomplicated TBAD had a stroke after TEVAR. Two reinterventions were performed on day 7 and day 9 after TEVAR.Patients with uncomplicated TBAD could be treated by early TEVAR, with a low rate of perioperative complications. In patients with uncomplicated TEVAR and high-risk features, early TEVAR with BMT should be considered as the treatment of choice.

4.
J Endovasc Ther ; : 15266028221127839, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36214450

RESUMO

PURPOSE: To analyze sac evolution patterns in matched patients with hostile neck anatomy (HNA) treated with standard endovascular aneurysm repair (sEVAR) and endosutured aneurysm repair (ESAR). METHODS: Observational retrospective study using prospectively collected data between June 2010 and December 2019. ESAR group data were extracted from the primary arm of the PERU registry with an assigned identifier (NCT04100499) at 8 centers and those from the sEVAR came from 4 centers. Suitability for inclusion required: no proximal endograft adjuncts (besides EndoAnchor use), ≤15 mm neck length and minimum of 12-months follow-up imaging. Bubble-shaped neck (noncylindrical short neck with discontinuous seal) aspect was analyzed. Both groups were analyzed using propensity score matching (PSM) for aortic neck length, width, angulation, and device fixation type. Main outcome assessed was sac evolution patterns (sac expansion and regression were defined as >5mm increase or decrease, of the maximum sac diameter respectively; all AAAs within this ±5 mm range in diameter change were considered stable) and secondary outcomes were type-Ia endoleaks; other endoleaks and mortality. A power analysis calculation >80% was confirmed for sac regression evaluation. RESULTS: After exclusions, PSM resulted in 96 ESAR and 96 sEVAR patients. Mean imaging follow-up (months) was 44.4±21.3 versus 43.0±19.6 (p=0.643), respectively. The overall number of patients achieving sac regression was higher in the ESAR group (n=57, 59.4% vs n=31, 32.3%; p<0.001) and the cumulative sac regression achieved at 5 years was 65% versus 38% (p=0.003) in favor of the ESAR group. There were no statistically significant differences in type-Ia endoleak and/or other endoleaks. Univariate analysis for sac regression patients in the sEVAR and ESAR group individually showed the bubble-shape neck as a predictor of sac regression failure. There were no statistical differences in overall and aneurysm-related mortality. CONCLUSION: Endosutured aneurysm repair provided improved rates of sac regression for patients with AAA and HNA when compared with sEVAR at midterm and up to 5 years, despite similar rates of type-Ia endoleaks, and the need to consider some important limitations. The presence of bubble-shaped neck was a predictor of sac regression failure for both groups equally. CLINICAL IMPACT: The use of EndoAnchors aids and improves EVAR treatment in hostile neck anatomies by an increased rate of sac regression when compared to EVAR treatment alone in up to 5 year analysis. Moreover, a trend to reduced number of type Ia endoleaks is also achieved, although not significant in the present study. This data, adds to current and growing evidence on the usefulness of EndoAnchors for AAA endovascular treatment.

5.
Ann Surg ; 273(5): 997-1003, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30973389

RESUMO

OBJECTIVE: The objective of this study was to evaluate the outcome of endovascular aortic arch repair for chronic dissection with a custom-made branched endograft. BACKGROUND: Acute type A aortic dissections are often treated with prosthetic replacement of the ascending aorta. During follow-up, repair of an aneurysmal evolution of the false lumen distal to the ascending prosthesis can be a challenge both for the surgeon and the patient. METHODS: We conducted a multicenter, retrospective study of consecutive patients from 14 vascular units treated with a custom-made, inner-branched device (Cook Medical, Bloomington, IN) for chronic aortic arch dissection. Rates of in-hospital mortality and stroke, technical success, early and late complications, reinterventions, and mortality during follow-up were evaluated. RESULTS: Seventy consecutive patients were treated between 2011 and 2018. All patients were considered unfit for conventional surgery. In-hospital combined mortality and stroke rate was 4% (n = 3), including 1 minor stroke, 1 major stroke causing death, and 1 death following multiorgan failure. Technical success rate was 94.3%. Twelve (17.1%) patients required early reinterventions: 8 for vascular access complication, 2 for endoleak correction, and 2 for pericardial effusion drainage. Median follow-up was 301 (138-642) days. During follow-up, 20 (29%) patients underwent secondary interventions: 9 endoleak corrections, 1 open repair for prosthetic kink, and 10 distal extensions of the graft to the thoracic or thoracoabdominal aorta. Eight patients (11%) died during follow-up because of nonaortic-related cause in 7 cases. CONCLUSIONS: Endovascular treatment of aortic arch chronic dissections with a branched endograft is associated with low mortality and stroke rates but has a high reintervention rate. Further follow-up is required to confirm the benefits of this novel approach.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Doença Crônica , Angiografia por Tomografia Computadorizada , Feminino , Seguimentos , Saúde Global , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
J Vasc Surg ; 74(2): 547-555, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33600932

RESUMO

OBJECTIVE: To evaluate short term outcomes related to the use of the Zenith TX2 Dissection Endovascular Graft (ZDEG) and the Zenith Dissection Bare stent (ZDES) for the treatment of Stanford type B aortic dissections. METHODS: This retrospective multicenter case cohort study collated data from 10 European institutions for patients with both complicated and uncomplicated type B aortic dissection treated with ZDEG and ZDES between 2011 and 2018. The primary end point was mortality at 30 and 90 days. Secondary end points included complications related to TEVAR, such as, type Ia endoleak, stroke, paraparesis, paraplegia, and retrograde type A dissection (RTAD). Statistical analysis was carried out using the t test, or one-way analysis of variance and the χ2 or Fisher exact tests. RESULTS: We treated 120 patients (87 male; mean age, 62.7 ± 12.2years) either in the acute 76 (63.3%), subacute 16 (13.3%), or chronic 28 (23.3%) phase. Seven patients (5.8%) died within 30 days after the index procedure and two (1.7%) between 30 and 90 days. There was one instance of postoperative RTAD in a patient treated for rupture. Stroke and paraplegia occurred in three (2.5%) and five (4.2%), patients, respectively. Eight patients (6.7%) had a type Ia endoleak in the perioperative period. There were no instances of paraplegia, no permanent dialysis, and no requirement for adjunctive superior mesenteric or celiac artery stenting in the 33 patients (27.5%) who were treated by concurrent placement of ZDES distal to the ZDEG. The length and distal oversizing of ZDEG components used was less in this group. CONCLUSIONS: The present series demonstrates a low (<1%) RTAD rate and favorable morbidity and mortality. The lower rate of paraplegia, dialysis, and visceral artery stenting in the cohort that had adjunctive use of ZDES is compelling and merits further assessment.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
J Endovasc Ther ; 28(4): 519-523, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33899573

RESUMO

PURPOSE: Open surgical repair of type Ia endoleak after endovascular aortic aneurysm repair/sealing (EVAR/EVAS) is associated with significant perioperative mortality and morbidity. Current endovascular redo techniques face limitations, especially when the infrarenal landing zone is inadequate and the previous endograft is rigid and features a short or no main body. We present a novel concept for the treatment of type Ia endoleak using a custom-made branched device. TECHNIQUE: The 5-branch-device (Cook Medical, Bloomington, IN, USA) consists of a nitinol skeleton with branches, covered with a low-profile polyester fabric loaded in an 18F sheath. The device features a minimum of 2 proximal sealing stents and includes branches for renovisceral vessels as well as an additional 8 mm branch for the contralateral iliac limb. Implantation and sealing in the renovisceral vessels is carried out in standard fashion, using transfemoral and transaxillary access. Distal sealing is achieved by tapering the branched component into the ipsilateral iliac limb and using a bridging balloon-expandable or self-expandable stent-graft through the additional branch to the preexisting contralateral iliac limb. CONCLUSION: Treatment of type Ia endoleak with a new custom-made device enables sufficient proximal seal while minimizing suprarenal aortic coverage and facilitates adequate component overlap. The low profile branched design accommodates implantation through the preexisting endograft and catheterization of target vessels.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Humanos , Desenho de Prótese , Stents , Resultado do Tratamento
8.
Ann Vasc Surg ; 73: 280-289, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33359692

RESUMO

BACKGROUND: Arterioureteral fistula refers to the anomalous fistulous connection between the iliac artery and the ureter. It is often associated with pelvic malignancy, abdominal surgery, and radiation. As it is a potentially life-threatening condition, prompt diagnosis and management is essential. METHODS: We performed a retrospective analysis of patients treated for arterioureteral fistula in a single-vascular institution from January 2013 to March 2019. Preoperative assessment included physical and laboratory examinations and medical history, with diagnosis established through computed tomography angiography, digital subtraction angiography, or ureteroscopy. Parameters analyzed included perioperative mortality and morbidity as well as treatment durability during midterm follow-up. RESULTS: Nine patients with ten arterioureteral fistulas were included in the study. Macroscopic hematuria was the main presenting symptom, with 2 patients admitted due to hemorrhagic shock. Endovascular treatment was carried out in 6 patients. In 4 cases, single stent-graft deployment inside the common iliac artery was performed, in one case in combination with plugging of the internal iliac artery. One patient underwent implantation of an iliac-branched device, whereas in another patient coiling of the internal iliac artery sufficed for management of the fistula. Open surgical repair was carried out in three cases. Perioperative mortality was zero; one patient had prolonged hospital stay due to superficial wound infection. Recurrent hematuria and stent-graft infection were observed during follow-up in three patients after endovascular repair, all of them treated through open surgery with no further complications. One patient developed an enterocutaneous fistula after open repair during follow-up and required redo surgery. DISCUSSION: Arterioureteral fistula is a challenging clinical scenario demanding prompt diagnosis and management. Open surgery remains the treatment of choice in cases of preexisting vascular reconstruction or manifest infection. Endovascular techniques offer a viable solution in significantly comorbid patients or in patients presenting with acute, life-threatening bleeding. Rigorous follow-up is required regardless of treatment modality due to the considerable rate of reinterventions.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Artéria Ilíaca/cirurgia , Doenças Ureterais/cirurgia , Fístula Urinária/cirurgia , Fístula Vascular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Doenças Ureterais/diagnóstico por imagem , Doenças Ureterais/mortalidade , Fístula Urinária/diagnóstico por imagem , Fístula Urinária/mortalidade , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/mortalidade
9.
J Vasc Surg ; 71(4): 1119-1127, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31791742

RESUMO

OBJECTIVE: The aim of this study was to investigate the incidence and impact of acute and chronic kidney dysfunction after branched endovascular aortic aneurysm repair (BEVAR) perioperatively and during follow-up. METHODS: Patients with a thoracoabdominal aortic aneurysm were treated with BEVAR. Serum creatinine; estimated glomerular filtration rate at baseline, after 48 hours, at discharge, and after 1 and two years; perioperative results; and outcome during follow-up were evaluated. RESULTS: Treatment of thoracoabdominal aortic aneurysm using BEVAR was performed in 113 patients (mean age, 71 years; 79 male) with 434 side branches and two additional fenestrations (0.46%) for renovisceral perfusion. Sixty patients (53%) underwent staged procedures with temporary aneurysm sac perfusion and secondary side branch completion. Perioperative mortality was 9 of 113 (8%). Postoperative acute kidney injury (AKI) was observed in 41 of 113 patients (36%) with recovery of renal function after 2 years in most patients. However, chronic kidney disease (CKD) stage progression after 1 and 2 years was observed in 25 of 104 patients (24%) and 17 of 52 patients (32.7%), respectively. Seven patients (6.7%) required permanent dialysis during 2 years of follow-up. Risk factors for AKI were nonstaged procedures (P = .02) and multiorgan failure (P = .01). CKD progression was related to renal branch reinterventions (P = .047), all branch reinterventions (P = .03), and postoperative AKI (P = .001). During follow-up, survival was decreased in patients with AKI, especially in those with nonmalignant diseases (P = .01). CONCLUSIONS: Postoperative AKI after BEVAR was observed in about one-third of patients associated with increased CKD stages after 2 years. Preoperative CKD was not a risk factor for postoperative AKI or perioperative outcome. The prevention of AKI by staged procedures, early interventions for renal side branch complications, and regular surveillance is recommended to improve outcomes.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/epidemiologia , Insuficiência Renal/epidemiologia , Idoso , Progressão da Doença , Feminino , Humanos , Testes de Função Renal , Masculino , Fatores de Risco
10.
Int J Mol Sci ; 21(14)2020 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-32698545

RESUMO

This review synthesizes knowledge on epigenetic regulation of leaf senescence and discusses the possibility of using this knowledge to improve crop quality. This control level is implemented by different but interacting epigenetic mechanisms, including DNA methylation, covalent histone modifications, and non-covalent chromatin remodeling. The genetic and epigenetic changes may act alone or together and regulate the gene expression, which may result in heritable (stress memory) changes and may lead to crop survival. In the review, the question also arises whether the mitotically stable epigenetic information can be used for crop improvement. The barley crop model for early and late events of dark-induced leaf senescence (DILS), where the point of no return was defined, revealed differences in DNA and RNA modifications active in DILS compared to developmental leaf senescence. This suggests the possibility of a yet-to-be-discovered epigenetic-based switch between cell survival and cell death. Conclusions from the analyzed research contributed to the hypothesis that chromatin-remodeling mechanisms play a role in the control of induced leaf senescence. Understanding this mechanism in crops might provide a tool for further exploitation toward sustainable agriculture: so-called epibreeding.


Assuntos
Produtos Agrícolas/genética , Epigênese Genética , Regulação da Expressão Gênica de Plantas , Hordeum/genética , Folhas de Planta/genética , Senescência Celular , Produção Agrícola , Produtos Agrícolas/citologia , Produtos Agrícolas/crescimento & desenvolvimento , Metilação de DNA , Código das Histonas , Hordeum/crescimento & desenvolvimento , Folhas de Planta/citologia , Folhas de Planta/crescimento & desenvolvimento
11.
Eur J Vasc Endovasc Surg ; 57(1): 102-109, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30181064

RESUMO

OBJECTIVES: Patients surviving acute aortic dissection are at risk of developing a post-dissection thoraco-abdominal aortic aneurysm (PD-TAAA) during follow up, regardless of the type of treatment in the acute setting. Fenestrated and branched stent grafting (F/B-TEVAR) has been used with success to treat PD-TAAA, albeit reported only with short-term results. The aim of this study was to report mid-term results in a cohort of 71 patients. METHODS: This was a retrospective analysis of a prospectively maintained database including all patients with PD-TAAAs who underwent F/B-TEVAR within the period January 2010 - April 2017 at two vascular institutions experienced in endovascular techniques. RESULTS: A total of 71 consecutive patients (56 male, mean age 63.8 ± 10.6 years) were treated. Technical success was achieved in 68/71 (95.8%) patients. In hospital mortality was four (5.6%) patients. Peri-operative morbidity was 19.6%. Three (4.2%) patients developed severe spinal cord ischaemia, one of these patients 12 months post-operatively. Mean follow up was 25.3 months (1-77 months). Cumulative survival rates at 12, 24, and 36 months were 84.7 ± 4.5%, 80.7 ± 5.1%, and 70.0 ± 6.7%, respectively. Estimated freedom from re-intervention at 12, 24, and 36 months was 80.7 ± 5.3%, 63.0 ± 6.9%, and 52.6 ± 8.0%, respectively. The main reasons for re-intervention were endoleak from visceral/renal arteries and iliac endoleak requiring extension. Target vessel occlusion occurred in 8/261 (3.1%) vessels (renal artery n = 4; superior mesenteric artery n = 2; coeliac artery n = 2). Mean aneurysm sac regression during follow up was 9.2 ± 8.8 mm, with a false lumen thrombosis rate of 85.4% for patients with a follow up longer than 12 months. No ruptures occurred during follow up. CONCLUSION: F/B-TEVAR for post-dissection TAAA is feasible and associated with low peri-operative mortality and peri-operative morbidity. Mid-term results demonstrate a high rate of aneurysm sac regression. Rigorous follow up is required because of the significant re-intervention rate. Longer bridging covered stents for target vessels are advised.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/complicações , Implante de Prótese Vascular , Stents , Idoso , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Reoperação , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Grau de Desobstrução Vascular
12.
Ann Vasc Surg ; 59: 36-47, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31009715

RESUMO

BACKGROUND: In situ fenestration of aortic stent grafts for treatment of aortic arch aneurysms is a new option for endovascular aortic arch repair. So far, only few reports have shown perioperative and short-term results of in situ fenestrations for aortic arch diseases. We present the multicenter experience with the aortic arch in situ fenestration technique documented in the AARCHIF registry for treatment of aortic arch aneurysms or localized type A aortic dissections and analyzed perioperative outcome and midterm follow-up. METHODS: Patients with aortic arch pathologies treated by aortic arch in situ fenestration with proximal stent graft landing in aortic arch Ishimura zones 0 and 1 were included in the registry. Stent-graft in situ fenestrations were created using needles or radiofrequency or laser catheters and completed by implantation of covered connecting stent grafts. Single in situ fenestrations for the left subclavian artery (LSA) were excluded. RESULTS: Between 06/2009 and 03/2017, twenty-five patients were treated by in situ stent-graft fenestrations for aortic arch pathologies at 9 institutions in 7 different countries, 3 of them as bailout procedures for stent-graft malplacement. In situ fenestrations were performed for the brachiocephalic trunk (n = 20), the left common carotid artery (n = 21) and the LSA (n = 9). Technical success for intended in situ fenestrations was 94.0% (47/50), with additional supraaortic bypass procedures performed in 14 patients. Perioperative mortality occurred in 1 (4.0%) patient, treated as a bailout procedure and 3 (12.0%) perioperative strokes were observed. One proximal aortic stent-graft nonalignment and 4 type III endoleaks, 2 early and 2 late, required reeintervention. During follow-up (1-118 months), the diameter of aortic arch aneurysms decreased from 61.5 ± 4.1 mm to 48.4 ± 3.2 mm (P = 0.02) and, so far, 6 patients died from diseases unrelated to their aortic arch pathologies with a mean survival time of 79.5 months and 3 endovascular reinterventions for distal aortic expansion were performed. Cerebrovascular event (n = 4) was the most relevant prognostic factor for mortality during midterm follow-up (P = 0.003). CONCLUSIONS: The aortic arch in situ fenestration technique for endovascular aortic arch repair seems to be valuable treatment option for selected patients, although initial consideration of other treatment options is mandatory. Data about long-term durability are required.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
Crit Care ; 22(1): 168, 2018 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-29973233

RESUMO

BACKGROUND: Basic science data suggest that acute kidney injury (AKI) induced by ischemia-reperfusion injury (IRI) is an inflammatory process involving the adaptive immune response. Little is known about the T-cell contribution in the very early phase, so we investigated if tubular cellular stress expressed by elevated cell cycle biomarkers is associated with early changes in circulating T-cell subsets, applying a bedside-to-bench approach. METHODS: Our observational pilot study included 20 consecutive patients undergoing endovascular aortic repair for aortic aneurysms affecting the renal arteries, thereby requiring brief kidney hypoperfusion and reperfusion. Clinical-grade flow cytometry-based immune monitoring of peripheral immune cell populations was conducted perioperatively and linked to tubular cell stress biomarkers ([TIMP-2]•[IGFBP7]) immediately after surgery. To confirm clinical results and prove T-cell infiltration in the kidney, we simulated tubular cellular injury in an established mouse model of mild renal IRI. RESULTS: A significant correlation between tubular cell injury and a peripheral decline of γδ T cells, but no other T-cell subpopulation, was discovered within the first 24 hours (r = 0.53; p = 0.022). Turning to a mouse model of kidney warm IRI, a similar decrease in circulating γδ T cells was found and concomitantly was associated with a 6.65-fold increase in γδ T cells (p = 0.002) in the kidney tissue without alterations in other T-cell subsets, consistent with our human data. In search of a mechanistic driver of IRI, we found that the damage-associated molecule high-mobility group box 1 protein HMGB1 was significantly elevated in the peripheral blood of clinical study subjects after tubular cell injury (p = 0.019). Correspondingly, HMGB1 RNA content was significantly elevated in the murine kidney. CONCLUSIONS: Our investigation supports a hypothesis that γδ T cells are important in the very early phase of human AKI and should be considered when designing clinical trials aimed at preventing kidney damage. TRIAL REGISTRATION: ClinicalTrials.gov, NCT01915446 . Registered on 5 Aug 2013.


Assuntos
Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/sangue , Animais , Aneurisma Aórtico/sangue , Aneurisma Aórtico/cirurgia , Biomarcadores/análise , Biomarcadores/sangue , Modelos Animais de Doenças , Proteína HMGB1/análise , Proteína HMGB1/sangue , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/análise , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/sangue , Rim/lesões , Rim/fisiopatologia , Camundongos Endogâmicos C57BL/sangue , Camundongos Endogâmicos C57BL/lesões , Projetos Piloto , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/diagnóstico , Traumatismo por Reperfusão/sangue , Traumatismo por Reperfusão/diagnóstico , Estatísticas não Paramétricas , Estresse Fisiológico/imunologia , Linfócitos T/imunologia , Linfócitos T/patologia , Inibidor Tecidual de Metaloproteinase-2/análise , Inibidor Tecidual de Metaloproteinase-2/sangue
14.
Int J Mol Sci ; 19(12)2018 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-30544617

RESUMO

Epithelial-mesenchymal transitions (EMTs) have been recently implicated in the process of cancer progression. The aim of this study was to assess how the preoperative expression patterns of EMT biomarkers correlate with the risk of postoperative invasion in ductal carcinoma in situ (DCIS) found on stereotactic breast biopsies. N-cadherin, Snail1, and secreted protein acidic and rich in cysteine (SPARC) immunoreactivity was observed in 8%, 62%, and 38% of tumors, respectively. Snail1 and SPARC expressions were significantly related to N-cadherin expression and to each other. The postoperative upgrading rate was associated with a positive preoperative expression of all biomarkers. Significance of Snail1 and SPARC persisted in multivariate analysis, but the impact of SPARC on invasion was more significant. When these two EMT triggers were considered together, the risk of invasion did not significantly differ between the subtypes of DCIS with single positive expression (SPARC-/Snail1+ vs. SPARC+/Snail1-). However, it was significantly lower in single-positive DCIS when compared to lesions of a double-positive profile (SPARC+/Snail1+). Moreover, there were no cases in the double-negative DCIS (SPARC-/Snail1-), with foci of infiltrating cancer found postoperatively in residual postbiopsy lesions. In contrast, DCIS with a combined high SPARC and Snail1 expression (intermediate or strong) had an invasive component in 66⁻100% of tumors.


Assuntos
Carcinoma Intraductal não Infiltrante/patologia , Transição Epitelial-Mesenquimal/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/metabolismo , Caderinas/metabolismo , Carcinoma Intraductal não Infiltrante/metabolismo , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Fatores de Transcrição da Família Snail/metabolismo
15.
Zentralbl Chir ; 143(5): 503-509, 2018 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-30357794

RESUMO

Complications during follow-up - including loss of seal and graft migration with endoleakage - are the Achilles heel of endovascular abdominal and thoracic aneurysm repair (EVAR and TEVAR, respectively). At the level of the proximal and distal landing zones, the characteristics of aortic anatomy include length and shape, thrombus, calcification, kinking and progressive dilatation, and these may impact the long-term durability of endovascular repair. Endoanchors have been shown to mimic the stability of a hand sewn aortic anastomosis. This report gives an overview of current literature on the use of endoanchors in EVAR and TEVAR. Indications for use include primary implantation to secure the proximal or distal landing zone, in case of unfavourable anatomy or intraoperative type I endoleak/suboptimal apposition to the aortic wall, as well as secondary use for the treatment of type I endoleaks and stent-graft migration often in conjunction with a proximal or distal extension of the stent-graft. To conclude the report, we analysed perioperative results of the first 100 patients treated with TEVAR/EVAR and endoanchors - primarily or secondarily - during re-interventions in our department. From March 2011 to November 2015, 100 patients (85 men, 15 women; mean age 70 ± 9.7 years) were treated. 82 applications were carried out in the abdominal and 18 in the thoracic aorta. The implantation was performed during the primary EVAR/TEVAR procedure in 80 cases (group A); 20 patients were treated secondarily (group B). Technical success was 100%. Clinical success was 98%. No endoanchors were lost. Perioperative mortality was 4% and morbidity 7%. During 30-day follow-up, endoleaks were found in 8/96 surviving patients. 7/8 patients had type II endoleaks, and one patient with secondary proximal extension of the thoracic stent-graft had a persistent type I endoleak.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aortografia , Prótese Vascular , Endoleak , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Stents , Fatores de Tempo , Resultado do Tratamento
16.
Zentralbl Chir ; 143(5): 516-525, 2018 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-30357795

RESUMO

BACKGROUND: Visceral artery aneurysms (VAA) are rare and often incidental findings. Indications for treatment are symptomatic patients, pseudoaneurysms and a true aneurysm of diameter of ≥ 2.5 cm for mesenteric arteries and ≥ 3 cm for renal artery aneurysms. Pregnancy and liver transplantation play an important role in aneurysm rupture. Technical success after open or endovascular procedure and maintenance of organ perfusion are crucial. The aim of this review is to evaluate our data and experience of more than 20 years and to develop a strategy to deal with visceral artery aneurysm in elective and emergency cases. PATIENTS: Between 1995 and 2018, 179 patients (84 males, 95 females, median age 62 [18 - 87] years) were diagnosed with VAA at the Regensburg University Hospital. The site of aneurysm was the splenic artery in 113 (63%) patients (pts), hepatic and renal arteries in 22 and 21 pts (12% each), and gastropancreaticoduodenal artery in 14 (8%) and superior/inferior mesenteric artery in 9 (5%) cases. Surveillance without intervention occurred in 110 (62%) pts, and 34 (19%) pts underwent open and 35 (19%) endovascular repair. In all patients, preoperative imaging was performed, preferably by computed tomography angiography (CTA). RESULTS: A total of 69 patients underwent open or endovascular repair. 51 (74%) pts were treated electively, 18 (26%) pts presented urgently with acute bleeding. 16 emergency pts received endovascular treatment, and in 2 pts open surgery was performed. After emergency treatment, two pts exhibited segmental liver malperfusion without consequences. In one case, segmental bowel resection was necessary. 32/51 (63%) patients were treated electively by open surgery, 19/51 (37%) by endovascular procedures. There were no liver or bowel infarctions. Four splenectomies and one unilateral nephrectomy were necessary in patients with splenic or renal artery aneurysms. Moreover, three partial renal infarctions were noticed postoperatively (overall 8/21 [38%]). After endovascular repair of splenic or renal artery aneurysms, two cases of splenic and three cases of renal segmental infarction were observed. Splenectomy had to be performed twice (overall 7/14 [50%]). Organ perfusion was monitored by CTA, and preferentially by contrast enhanced ultrasound. CONCLUSION: The endovascular approach is the preferred option in an emergency to control bleeding in pseudoaneurysms. Patients for elective splenic or renal artery aneurysm repair have to be evaluated very carefully to achieve technical success with occlusion of the aneurysm and excellent organ perfusion. Imaging techniques such as ultrasound, especially CEUS, are strongly recommended in postoperative follow-up. Partial or complete splenic infarction leads to vaccination.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Vísceras , Adulto Jovem
17.
J Vasc Surg ; 65(2): 538-541, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27471177

RESUMO

We report successful endovascular repair of a 61-year-old man treated for a 7.1-cm excentric aortic arch aneurysm by in situ stent graft fenestration for the brachiocephalic trunk and the left common carotid artery. Cerebral perfusion during the intervention was maintained by pump-driven extracorporal bypass to the right common carotid artery and to the left axillary artery provided with a left carotid-subclavian bypass. After 5 years of follow-up, the aortic arch in situ revascularization is still patent, the aneurysm excluded, and no endoleak detectable, although endovascular reintervention with distal aortic stent graft extension due to dilatation of the descending aorta was required.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Fatores de Tempo , Resultado do Tratamento
18.
J Vasc Surg ; 65(6): 1577-1583, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28216346

RESUMO

OBJECTIVE: The aim of this study was to evaluate the impact of intercostal and lumbar segmental arteries (SAs) detectable on computed tomography angiography (CTA) on the risk of spinal cord ischemia (SCI) in patients undergoing single-step or two-staged branched endovascular aneurysm repair (BEVAR). METHODS: A retrospective analysis of patients treated with branched stent grafts for thoracoabdominal aortic aneurysm at a single institution from January 2009 to June 2015 was performed. Data including preoperative comorbidities, perioperative and aneurysm-related parameters, presence and type of endoleak, and rate of severe SCI at discharge or 30 days after the procedure were collected. Preoperative and postoperative contrast-enhanced CTA images were semiquantitatively analyzed by two independent investigators, and the number of visible SAs in the stented aorta before and after BEVAR was evaluated to find a possible correlation with severe SCI. RESULTS: Seventy-seven patients were treated for thoracoabdominal aortic aneurysm with BEVAR (47 men; mean age, 71.0 years), 40 (51.9%) of them with temporary aneurysm sac perfusion (TASP; open branch/TASP group) and 37 without (single-step group). The groups were comparable regarding parameters related to the patient, aneurysm type, and endovascular procedure. Severe SCI or paraplegia was observed in 10 patients (12.3%), and SCI was lower in the open branch/TASP group (2/40) compared with the single-step group (8/37; P = .032). The number of visible SAs in the intentionally overstented aortic segment was significantly reduced on postoperative CTA (10.0 vs 15.57 SAs; P < .001) in comparison to preoperative CTA imaging, with similar results in the open branch/TASP group (9.48 vs 15.83 SAs) and the single-step group (10.57 vs 15.30 SAs; P < .001 for both groups). Within the open branch/TASP group, more visible SAs were detected during the TASP interval in comparison to postoperative CTA after side branch completion (12.93 vs 9.48 SAs; P < .001). Receiver operating characteristic curve analysis in the single-step group revealed a cutoff point of 15 SAs on preoperative CTA with correlation to severe SCI (P = .006). In the high-risk subgroup of patients with 15 or more overstented SAs during BEVAR, staged open branch/TASP procedures again reduced the risk of SCI in comparison to the single-step patients (1/20 vs 8/22; P = .008). CONCLUSIONS: More spinal arteries are visible during the TASP interval, supporting the open branch and TASP concept with a reduction of severe SCI during BEVAR. An intentional coverage of more than 15 SAs is related to an increased risk of SCI, and the rate of paraplegia was reduced after staged BEVAR with open branch/TASP in these high-risk patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Artérias/diagnóstico por imagem , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Coluna Vertebral/irrigação sanguínea , Lesões do Sistema Vascular/prevenção & controle , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Alemanha , Humanos , Masculino , Paraplegia/etiologia , Paraplegia/prevenção & controle , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Proteção , Estudos Retrospectivos , Fatores de Risco , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/prevenção & controle , Stents , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia
19.
J Endovasc Ther ; 24(2): 230-236, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28205454

RESUMO

PURPOSE: To report the outcomes of fenestrated endovascular aneurysm repair (FEVAR) and compare early and midterm results in relation to stent-graft complexity. METHODS: Between August 2006 and December 2014, 141 consecutive patients (mean age 72±7.6 years, range 50-89; 120 men) were treated electively with FEVAR for short-neck, juxtarenal, or suprarenal aortic aneurysms. Forty-five patients treated with stent-grafts featuring renal-only fenestrations were assigned to group A, while 96 patients receiving additional fenestrations for the superior mesenteric and/or celiac arteries were assigned to group B. Technical success, operative mortality and morbidity, target vessel patency, endoleak, reintervention, and survival were compared between the groups. Survival, target vessel stent patency, and reintervention during follow-up were estimated by Kaplan-Meier analysis; the estimates are presented with the 95% confidence interval (CI). RESULTS: Technical success was achieved in 135 (95.7%) patients. Overall 30-day operative mortality was 3.5% (5/141). Perioperative complications occurred in 16 (12.1%) patients. Mean follow-up was 33±23 months. Overall estimated survival was 85.1% (95% CI 79.1% to 91.1%) at 1 year and 75.8% (95% CI 68.2% to 83.5%) at 3 years. Freedom from reintervention was 90.6% (95% CI 85.6% to 95.6%) at 1 year and 79.2% (95% CI 71% to 87.5%) at 3 years. There was no statistically significant difference between the groups in terms of perioperative mortality or morbidity, endoleak, survival, target vessel patency, or reintervention. CONCLUSION: The use of FEVAR for juxta- and suprarenal aneurysms is associated with low 30-day mortality/morbidity and high midterm efficacy. So far, perioperative and midterm results are not affected by the use of more complex fenestrated designs.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Intervalo Livre de Doença , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Surg Oncol ; 116(6): 696-705, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28570750

RESUMO

BACKGROUND AND OBJECTIVES: Transcription factor Snail1 is a key inducer of epithelial-mesenchymal transition (EMT), a biological process implicated in the cancer progression and metastasis. The aim of the study was to investigate Snail1 expression in DCIS found on breast biopsy and assess its predictive value for the final invasion. METHODS: A total of 209 patients with histologically diagnosed pure DCIS entered the study. Snail1 reactivity was evaluated with immunohistochemistry in tumor tissue from stereotactic vacuum-assisted biopsy of suspicious microcalcifications. RESULTS: Snail1 staining was observed in 62% of tumors: weak, intermediate, and strong in 27%, 21%, and 14% of lesions, respectively. Positive Snail1 expression was significantly rarer in DCIS presenting as powdery microcalcifications, when compared with crushed stone-like and casting-type and was more common in DCIS with comedonecrosis. Correlation with other features was not significant. None of standard parameters significantly influenced the upgrading rate. In contrast, in uni- and multivariate analysis the risk of postoperative invasion was significantly associated with positive Snail1 immunoreactivity. Moreover, there was a significant stepwise increase of upgrading rate according to Snail1 expression in DCIS cells: weak 9%, intermediate 26%, and strong 55%, respectively. CONCLUSIONS: Snail1 can reflect the invasive potential of DCIS and help identify its more aggressive subtypes.


Assuntos
Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/metabolismo , Carcinoma Ductal de Mama/patologia , Fatores de Transcrição da Família Snail/biossíntese , Adulto , Idoso , Idoso de 80 Anos ou mais , Calcinose , Transição Epitelial-Mesenquimal , Feminino , Humanos , Biópsia Guiada por Imagem , Imuno-Histoquímica , Pessoa de Meia-Idade , Invasividade Neoplásica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA