Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 33(1): 156-163, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37659704

RESUMO

BACKGROUND: The purpose of this study was to create a model to simulate treatment of unreconstructable distal humerus fractures with hemiarthroplasty. Stability was restored with a latest plate-system that simultaneously tensions medial and lateral collateral ligament grafts. MATERIALS AND METHODS: Static varus and valgus elbow stability was tested in 11 cadaver elbows with intact ligaments and capsule at 5 flexion angles (0°, 30°, 60°, 90°, 120°). The elbows were then destabilized via release of all ligaments and capsular attachments. The distal humerus articular cartilage was excised and replaced with an uncemented hemiarthroplasty. Ligament reconstruction was subsequently performed, and elbow stability was measured and compared to the native state. Dimensions of the hemiarthroplasty component were compared to native elbow dimensions to assess and quantify any existing relationship to elbow stability. RESULTS: A hemiarthroplasty was implanted in all specimens. A size mismatch occurred between the distal humerus trochlea and the olecranon fossa in all specimens and averaged 6.3 mm. Following ligament reconstruction, specimens reproduced the flexion angle-dependent stability of native elbows to both varus and valgus stress. On the medial side, elbow joint stability in mid-flexion was approximately 7% tighter after hemiarthroplasty. Laterally, the elbow was approximately 15% tighter after hemiarthroplasty and demonstrated peak stability in full flexion. The 3 assessed hemiarthroplasty components and bony dimensions did not exhibit any relationship between implant-bone mismatch and elbow stability after ligamentous reconstruction. CONCLUSION: Cadaveric elbow specimens underwent uncemented hemiarthroplasty with soft tissue stabilization with a novel technique for ligament reconstruction. Following hemiarthroplasty and ligament reconstruction, these specimens maintained secure fixation between ligament and bone. Static stability was maintained at varying degrees of elbow flexion regardless of variable mismatch between the hemiarthroplasty component and the native olecranon fossa.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Hemiartroplastia , Instabilidade Articular , Procedimentos de Cirurgia Plástica , Humanos , Cotovelo/cirurgia , Articulação do Cotovelo/cirurgia , Ligamentos Colaterais/cirurgia , Cadáver , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Instabilidade Articular/cirurgia
2.
J Hand Surg Am ; 48(10): 1065.e1-1065.e4, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36914454

RESUMO

Flexor tendon repair in zone II benefits from early finger motion to prevent stiffness. This article presents a technique that serves to augment a zone II flexor tendon repair with an externalized detensioning suture that can be used following any commonly employed repair method. This simple technique enables early active motion and is suited for patients who are less likely to be compliant after surgery or when the soft-tissue injury to the finger and hand is substantial. Although this technique substantially strengthens the repair, a possible drawback is that the tendon excursion distal to the repair is limited until the externalized suture is removed, which may lead to less motion of the distal interphalangeal than what may have occurred without the detensioning suture.


Assuntos
Traumatismos dos Dedos , Traumatismos dos Tendões , Humanos , Traumatismos dos Tendões/cirurgia , Traumatismos dos Dedos/cirurgia , Tendões/cirurgia , Dedos/cirurgia , Suturas , Técnicas de Sutura
3.
J Hand Surg Am ; 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36966046

RESUMO

PURPOSE: A ligament reconstruction method that simultaneously tensions the medial and lateral sides of the elbow and maintains tension with compression plates on the proximal ulna is proposed for the treatment of bidirectional elbow ligament instability. Graft slippage, catastrophic failure, and excessive displacement were evaluated. Biomechanical stability without graft slippage was hypothesized. METHODS: Eight cadaveric ligament reconstruction simulations were created through the dissection of three cadaver arms. Each reconstruction was statically tested with 160 N in a manner where it was first augmented with an absorbable suture and then without. Then, 3 more ligament reconstruction simulations were created for dynamic testing with each undergoing testing at 80 N for 2,000 cycles at 2 Hz. Construct displacement and graft slippage were recorded for each load application. RESULTS: No grafts failed catastrophically and no graft slippage was observed with either static or dynamic loading. Under static loading, the mean change in displacement between augmented and nonaugmented ligament reconstruction simulations was 28.7% ± 21% (augmented 3.95 ± 1.81 mm vs nonaugmented 4.89 ± 2.22 mm). The mean stiffness was 66.6 ± 26.6 N/mm for augmented and 64.6 ± 23.2 N/mm for nonaugmented simulations. With dynamic loading, the mean displacement for augmented graft ligament reconstruction simulations was 1.55 ± 0.16 mm compared with 2.18 ± 0.77 mm for nonaugmented reconstruction simulations. CONCLUSIONS: This method of fixation to the proximal ulna for the simultaneous reconstruction of medial and lateral elbow ligaments successfully prevented graft slippage without excessive construct displacement during static and dynamic testing. Ligament augmentation with absorbable sutures decreased the construct displacement. CLINICAL RELEVANCE: This ligament fixation method may be a viable alternative for the treatment of concomitant medial and lateral elbow instability.

4.
J Hand Surg Am ; 48(3): 312.e1-312.e10, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34916115

RESUMO

PURPOSE: The goal of this study was to test a novel uncemented and unconstrained total elbow arthroplasty (Kaufmann total elbow) design that is stabilized through a ligament reconstruction. METHODS: We quantified the implant stability after 25,000 cycles, which represents the time between implantation and when ligament and bone healing has occurred. We used an active motion experimental setup that applies tendon loads via pneumatic cylinders and reproduces the forearm-originating dynamic stabilizers of the elbow. The novel total elbow arthroplasty was actuated for 5,000 full flexion-extension cycles at 5 different shoulder positions. Four Sawbones and 4 cadaver elbows were employed. Angular laxity and implant stability were recorded prior to testing and after each 5,000-loading cycle. RESULTS: Four Sawbones and 4 cadaver elbows were implanted with the uncemented total elbow arthroplasty and did not demonstrate fixation failure or substantial laxity after 25,000 cycles of loading imparted at different shoulder positions. CONCLUSIONS: Our findings demonstrate that the Kaufmann total elbow replacement implanted into cadaver and Sawbones specimens did not exhibit fixation failure or excessive laxity after 25,000 cycles. CLINICAL RELEVANCE: An uncemented, nonmechanically linked total elbow arthroplasty that gains component fixation using intramedullary screws and employs a ligament reconstruction to stabilize the elbow has the potential to be a valuable management option, particularly in younger patients.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Prótese de Cotovelo , Humanos , Fenômenos Biomecânicos , Antebraço , Articulação do Cotovelo/cirurgia , Ligamentos Colaterais/cirurgia , Cadáver , Amplitude de Movimento Articular
5.
J Hand Surg Am ; 2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37589618

RESUMO

PURPOSE: This study aimed to examine the effect of flexion on valgus carrying angle in the human elbow using a dynamic elbow testing apparatus. METHODS: Active elbow motion was simulated in seven cadaveric upper extremities. Six electromechanical actuators simulated muscle action, while 6 degrees-of-freedom joint motion was measured with an optical tracking system to quantify the kinematics of the ulna with respect to the humerus as the elbow was flexed at the side position. Repeatability of the testing apparatus was assessed in a single elbow over five flexion-extension cycles. The varus angle change of each elbow was compared at different flexion angles with the arm at 0° of humerothoracic abduction or dependent arm position. RESULTS: The testing apparatus achieved excellent kinematic repeatability (intraclass correlation coefficient, >0.95) throughout flexion and extension. All elbows decreased their valgus carrying angle during flexion from 0° to 90° when the arm was maintained at 0° of humerothoracic abduction. Elbows underwent significant total varus angle change from full extension of 3.9° ± 3.4° (P = .007), 7.3° ± 5.2° (P = .01), and 8.9° ± 7.1° (P = .02) at 60°, 90°, and 120° of flexion, respectively. No significant varus angle change was observed between 0° and 30° of flexion (P = .66), 60° and 120° of flexion (P = .06), and 90° and 120° of flexion (P = .19). CONCLUSIONS: The dynamic elbow testing apparatus characterized a decrease of valgus carrying angle during elbow flexion and found that most varus angle changes occurred between 30° and 90° of flexion. All specimens underwent varus angle change until at least 90° of flexion. CLINICAL RELEVANCE: Our model establishes the anatomic decrease in valgus angle by flexion angle in vitro and can serve as a baseline for testing motion profiles of arthroplasty designs and ligamentous reconstruction in the dependent arm position. Future investigations should focus on characterizing motion profile change as the arm is abducted away from the body.

6.
J Hand Surg Am ; 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37552143

RESUMO

PURPOSE: The objective of this study was to determine the structural properties of the cadaver bone-screw interface for cementless intramedullary screw fixation in the context of total elbow arthroplasty. METHODS: The intramedullary canals of seven humerus and seven ulna specimens from fresh-frozen cadavers were drilled using custom drill bits until the inner cortex was reached and then hand tapped for the corresponding thread size. Titanium screws were advanced into the tapped holes until securely seated. The bones were potted and then mounted on a uniaxial material testing machine. A tensile load was applied, and end-of-test elongation, failure load, energy absorbed, and stiffness were determined. End-of-test load and elongation were defined as the elongation and load experienced by the structure at 3,000 N or failure. Each specimen was inspected for evidence of pullout, loosening, or visible fractures. RESULTS: The end-of-test load and elongation for the humerus specimens were 2721 ± 738 N and 3.0 ± 0.9 mm, respectively. The ulna specimens reached 92% of the humerus specimens' end-of-test load at 2,514 ± 678 N and 120% of their end-of-test elongation (3.6 ± 0.6 mm). The stiffness of the humerus specimens was 1,077 ± 336 N/mm, which was 1.3 times greater than the stiffness of the ulna specimens (790 ± 211 N/mm). Lastly, the energy absorbed by the humerus samples was 3.6 ± 1.6 J, which was 92% of the energy absorbed by the ulna samples at 3.9 ± 1.1 J. One humerus and three ulnas failed before the end-of-test load of 3,000 N. Two failures were caused by screw pullout and two by bone fracture. CONCLUSIONS: Our findings demonstrate that intramedullary screw fixation is successful in withstanding forces that are greater than required for osseointegration. CLINICAL RELEVANCE: Uncemented fixation may be beneficial in elbow arthroplasty.

7.
J Hand Surg Am ; 47(10): 1014.e1-1014.e8, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34579980

RESUMO

PURPOSE: The goal of this study was to test the pullout strength of intramedullary (IM) screws from within the humerus to establish their ability to seat an uncemented elbow arthroplasty. METHODS: Six humerus and 6 ulna Sawbones specimens were drilled with a drill bit diameter of 5/16 inches, and the inner cortex was hand tapped for a ⅜-16 thread. A ⅜-16 custom-made titanium screw with an outer bolt diameter of 3/8 inches and 16 threads per inch was inserted by hand into the tapped holes. The specimens were then axially tensile loaded at a rate of 5 mm per minute until either the screw began to pull out from the bone or a fracture was noted. RESULTS: Intramedullary screw fixation in the humerus achieved an average pullout strength of 1,439 pound-force (6,401 N), and IM screw fixation in the ulna achieved an average pullout strength of 882 pound-force (3,923 N). A fracture was noted in 3 humeral specimens, with 3 screws pulling out. In the ulna, the IM axial load caused a fracture in 5 specimens, and in 1 specimen, the screw pulled out. CONCLUSIONS: Our findings demonstrate that IM screw fixation can create a tensile force within the screw that is greater than that required to generate the calculated level of compression between the implant and bone. CLINICAL RELEVANCE: This may be beneficial in ensuring fixation between arthroplasty components and bone.


Assuntos
Fraturas Ósseas , Titânio , Fenômenos Biomecânicos , Parafusos Ósseos , Humanos , Úmero/cirurgia , Ulna/cirurgia
8.
J Hand Surg Am ; 47(1): 79-83, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34561136

RESUMO

Corticosteroid injection (CSI) is a commonly used tool in hand surgery that is often given little consideration as a potential detriment to vaccination efficacy. The authors reviewed guidelines issued by relevant societies for the timing of CSI around the severe acute respiratory syndrome coronavirus 2 vaccination period and the evidence used to support them. Ultimately, providers and patients should be adequately educated on the theoretical risks and benefits before proceeding with CSI immediately before, during, or immediately after coronavirus disease 2019 vaccination.


Assuntos
COVID-19 , SARS-CoV-2 , Corticosteroides , Humanos , Injeções , Vacinação
9.
J Hand Surg Am ; 47(3): 275-278, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34716057

RESUMO

Nonabsorbable suture augmentation of ligament reconstruction has seen an increase in use over the past several years with the goal of protecting the newly reconstructed ligament while allowing early rehabilitation for a potential earlier return to activity and sport. By spanning the joint with a durable nonabsorbable suture, this construct shares the stress and load seen by the reconstructed ligament, thereby protecting it from forces that could result in an early failure during the early ligamentization phase of the tendon graft. However, stress shielding of the ligament via nonabsorbable suture augmentation is also a double-edged sword, as a reduction in the stress and load seen by the ligament during this healing phase may ultimately have an impact on the final strength and composition of the reconstructed ligament. Although the long-term effects of this stress shielding have yet to be studied or reported in human subjects, multiple biomechanical and animal studies have demonstrated overall changes in architecture, tensile strength, and mechanical properties of a stress-shielded autograft ligament reconstruction.


Assuntos
Procedimentos Ortopédicos , Suturas , Animais , Biologia , Fenômenos Biomecânicos , Humanos , Ligamentos/cirurgia
10.
J Hand Surg Am ; 45(6): 528-535, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32299691

RESUMO

The elbow positions the hand in a stable manner relative to the trunk while allowing flexion and extension as well as forearm rotation at varying shoulder positions. Its ability to perform this task without joint subluxation is accomplished through a combination of bony congruency, ligamentous restraint, and dynamic stabilization. This article reviews the bony and dynamic contributors to elbow stability and kinematics. Bony stability is conferred through the morphology of the humeroulnar, humeroradial, and radioulnar joints. Depending on the arm position relative to the trunk and the degree of elbow flexion, the bony contribution will vary. Dynamic elbow stabilizers confer stability through the activation of various muscles that cross the elbow. These forces help resist valgus and varus forces and may also increase bony stability by generating compressive forces. The goal of this article is to review the literature surrounding the biomechanics of bony and dynamic stabilizers of the elbow while drawing clinically relevant biomechanical observations.


Assuntos
Articulação do Cotovelo , Cotovelo , Fenômenos Biomecânicos , Antebraço , Humanos , Amplitude de Movimento Articular
11.
J Hand Surg Am ; 45(2): 140-147, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31870564

RESUMO

The elbow positions the hand in a stable manner relative to the trunk while allowing flexion and extension as well as forearm rotation at varying shoulder positions. Its ability to perform this task without joint subluxation is accomplished through a combination of bony congruency, ligamentous restraint, and dynamic stabilization. Elbow stability is challenged repeatedly during everyday activities, particularly when the arm is abducted. Traumatic injuries that lead to an elbow dislocation or the microtrauma associated with pitching are frequent situations that destabilize the elbow. This article reviews the soft tissue stabilizers that contribute to elbow kinematics and stability.


Assuntos
Articulação do Cotovelo , Cotovelo , Fenômenos Biomecânicos , Humanos , Amplitude de Movimento Articular , Ombro
12.
J Hand Surg Am ; 44(8): 687-692, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30770149

RESUMO

Total elbow arthroplasty (TEA) has lower revision-free survivorship than other major joint replacement. Despite this, elbow replacement has remained popular. Surgical technique for TEA destabilizes the elbow by removing the medial and lateral collateral ligaments and, frequently, the radiocapitellar articulation. Current semiconstrained implants aim to allow for physiological varus and valgus motion by employing a sloppy hinge; however, over time, these designs fail owing to nonanatomic force transmission. Nonanatomic force transmission results from ligament release, force transmission primarily to the humeral and ulnar shafts, and radial head resection. These altered biomechanics may be the source of complications seen in semiconstrained arthroplasty. These complications perpetuate the cycle of failure and ultimately have poor salvage options.


Assuntos
Artroplastia de Substituição do Cotovelo/métodos , Artroplastia de Substituição do Cotovelo/instrumentação , Fenômenos Biomecânicos , Ligamentos Colaterais/cirurgia , Humanos , Prótese Articular , Desenho de Prótese , Falha de Prótese
13.
Muscle Nerve ; 52(6): 1117-21, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26206065

RESUMO

INTRODUCTION: Posterior interosseous nerve (PIN) syndrome is a rare compression neuropathy. Electrodiagnostic studies (EDx) combined with neuromuscular ultrasound (US) enable precise lesion localization and may improve patient outcome. METHODS: In 4 patients with finger extension weakness, US was used to accurately localize concentric electromyographic (EMG) needle placement in PIN muscles and to visualize the lesion site. RESULTS: EMG with US guidance showed decreased recruitment with abnormal configuration in PIN muscles. Active denervation was not always observed. US scanning demonstrated larger PIN diameter in the affected arm. All patients had surgical intervention to confirm EDx and US findings and had improved outcome on follow-up. CONCLUSION: These cases demonstrate the benefits of augmenting EDx with US by guiding accurate electrode localization and providing diagnostic information about lesion location.


Assuntos
Eletromiografia , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Doenças do Sistema Nervoso Periférico/diagnóstico , Ultrassonografia Doppler , Idoso , Humanos , Masculino , Pessoa de Meia-Idade
14.
Plast Reconstr Surg ; 153(3): 584e-596e, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37257128

RESUMO

BACKGROUND: The Boston Carpal Tunnel Questionnaire (BCTQ) is a validated measurement tool to assess the severity of carpal tunnel syndrome, and improvements in the BCTQ after carpal tunnel release (CTR) have been demonstrated to influence patient satisfaction. The authors hypothesized that patient-related factors influence response in BCTQ subscales, including the Symptom Severity Scale and the Functional Status Scale, after CTR. METHODS: Patients who underwent surgery with follow-up BCTQ were identified from a prospectively maintained database. Paired t tests were used to compare BCTQ subscales at each follow-up time point. Minimal clinically important differences were set. Patients below these thresholds were deemed as having failure to improve after CTR. Univariate analysis was used to identify risk factors for failure to improve after CTR. Multivariate logistic regression was used to identify independent predictors for failure to improve after CTR. RESULTS: A total of 106 patients met inclusion criteria. Patients demonstrated significant improvements at all follow-up time points. The factor most associated with improvement beyond the minimal clinically important differences was a more severe score in the respective domain assessed. Other independent factors that influenced outcome after CTR included race, concomitant cubital tunnel release, sex, and age. CONCLUSIONS: CTR results in significant improvements in BCTQ and its subscales, with improvements stabilizing after 6 weeks. In a select cohort of patients, failure to improve after CTR occurs with factors independently associated with a lower degree of improvement. Identification of patients with these risk factors will provide a basis for counseling and increased monitoring of patients at risk for a guarded prognosis. CLINICAL QUESTION/LEVEL OF EVIDENCE: Risk, III.


Assuntos
Síndrome do Túnel Carpal , Humanos , Síndrome do Túnel Carpal/cirurgia , Síndrome do Túnel Carpal/complicações , Modelos Logísticos , Satisfação do Paciente , Punho , Inquéritos e Questionários
15.
Orthopedics ; 47(2): 113-117, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37561106

RESUMO

Flexor tendon injuries of the hand, especially in zone II, pose a challenge for hand surgeons because of the region's intricate pulley mechanism and local avascularity, and post-surgical complications such as repair failure are not uncommon. One proposed predictor of outcomes following flexor tendon repair has been timing of surgery from initial injury. However, the effect of the timing of flexor tendon repair on failure rates remains controversial and understudied. The purpose of this study was to compare the failure rates of zone II flexor tendon repairs in patients at various time intervals from onset of injury. A retrospective chart review was conducted using data from hand surgery specialists at our level 1 trauma center from January 1, 2010, through May 31, 2020. This retrospective review included 407 zone II flexor tendon repairs. The primary outcome was failure of repair. Among 407 flexor tendon repairs, there were 12 reported repair failures. The failure rate was 2.9%. In the non-failure group, the mean number of days between the date of injury and the date of surgery was 7±13 days. For the failure group, this value was 14±17 days. Repairs occurring within 14 days had a failure rate of 2.3%, while repairs occurring beyond 14 days had a failure rate of 7.7%. This study demonstrates that there is a benefit to repairing the tendon within a 14-day window, as evidenced by a lower failure rate. More research is required to determine if other complications and overall health of the hand are also improved when a repair is performed in a more expedient manner. [Orthopedics. 2024;47(2):113-117.].


Assuntos
Traumatismos dos Dedos , Ortopedia , Traumatismos dos Tendões , Humanos , Estudos Retrospectivos , Tendões , Mãos/cirurgia , Traumatismos dos Tendões/cirurgia , Traumatismos dos Dedos/cirurgia
16.
J Hand Surg Glob Online ; 6(1): 21-26, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38313614

RESUMO

Purpose: The goal of this study was to develop a dynamic elbow testing apparatus that reproduces active joint motion at different shoulder positions to quantify the capabilities of total elbow arthroplasty designs. Methods: We designed a testing apparatus to create active cyclic elbow joint motion in human cadaveric and sawbones composite upper extremities. Two pneumatic actuators recreated humerus-originating muscles while rubber bands simulated forearm muscle action. Arthroplasty durability was quantified through laxity assessment at predetermined cyclic loading intervals. Results: Humeral forces were recorded in three specimens to generate active elbow motion at different degrees of shoulder abduction. The laxity in varus and valgus was measured as deflection between two fixed markers. Conclusions: In vitro simulation of elbow biomechanics through active cyclic elbow motion at different degrees of shoulder abduction may characterize in vivo performance of total elbow arthroplasty. Clinical relevance: Quantifying total elbow arthroplasty stability after cyclic loading in different shoulder positions may assist preclinical evaluation of arthroplasty designs.

17.
J Hand Surg Glob Online ; 6(2): 233-235, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38903837

RESUMO

Polymethyl methacrylate remains the only US Food and Drug Administration-approved method of total elbow arthroplasty fixation and exhibits high aseptic loosening rates that result in challenging revision surgeries and potential morbidity secondary to bone-cement implantation syndrome. In this policy paper, the authors aim to explore the historical background of polymethyl methacrylate and the complications that arise in association with its use. We will review arthroplasty trends in the elbow and lower extremities and the challenges with the US Food and Drug Administration-approval process.

18.
Hand (N Y) ; : 15589447241235343, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38516828

RESUMO

BACKGROUND: Thumb metacarpophalangeal (MP) fusion is generally successful; however, complications have been reported to occur in 0% to 30% of cases, whereas nonunion rates vary by method but, overall, are reported to occur in 0% to 15% of cases. Many fixation techniques have been described, but there is no consensus on the optimal fusion technique. Our goal was to compare complication and union rates of different thumb MP arthrodesis techniques. METHODS: We performed a retrospective review of patients who underwent primary thumb MP fusion between 2000 and 2022. Patients who underwent revision fusion, fusion for infection, or amputation were excluded. Fusions of MP joints of other fingers were also excluded. Data collection consisted of demographic data, complications, time to fusion, rate of delayed union and rate of nonunion. Five different fusion constructs were evaluated during our study period: staples, Kirschner wires (K-wires), cerclage, K-wires with cerclage, and intramedullary screw. RESULTS: Forty-seven patients underwent fusion with staples, 16 with K-wires, 14 with cerclage, 9 with K-wires and cerclage, and 6 with an intramedullary screw. The individual complication and nonunion rates differed significantly among the groups with the intramedullary screw group having a statistically higher rate of nonunion (P = .004). Furthermore, smoking, diabetes, and being overweight were associated with nonunions. CONCLUSION: Union rates were significantly lower in patients treated with an intramedullary screw and those who are smokers, diabetics, and/or overweight. Caution should be exercised when using intramedullary screw fixation for MP fusion, especially in patients with these comorbidities.

19.
J Hand Surg Glob Online ; 6(1): 91-97, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38313617

RESUMO

Management of elbow arthritis in younger and higher demand patients is challenging and may benefit from a distal humerus hemiarthroplasty that employs a noncemented method of implant fixation and stabilizes the elbow through ligament reconstruction. By not replacing both articulating surfaces, hardware longevity may be improved. We describe a novel system that may be indicated for the treatment of posttraumatic or primary osteoarthritis of the distal humerus. The step-by-step technique for surgical implantation of this uncemented distal humerus hemiarthroplasty is described and illustrated.

20.
Hand (N Y) ; 18(4): 589-597, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-34933586

RESUMO

BACKGROUND: Scaphoid excision 4-corner fusion is a motion-sparing procedure in patients with advanced radioscaphoid arthritis. This study introduces an alternate technique for scaphoid excision 4-corner fusion using a parallel Kirschner wire (K-wire) construct across the midcarpal joints that leads to reliable fusion rates, and good patient outcomes. METHODS: This is a single-surgeon, retrospective study of patients who underwent scaphoid excision 4-corner fusion, using a parallel K-wire construct across the midcarpal joints. Once fusion was achieved, K-wires were removed. Radiographic union rate, time to union, capitolunate angle, capitolunate coverage, and amount of midcarpal settling are measured. Patient-reported outcome measures and descriptive statistics are presented. RESULTS: Sixty-five wrists were included in this study with a mean age of 50.1 years. One patient was lost to follow-up. All 64 wrists (100%) fused at an average of 2.6 months. The mean capitolunate angle was 7°, and capitolunate coverage was 99.2%. Fifty-two patients (81%) had adequate radiographs for measurement. Average midcarpal settling was 1.1 mm. Thirty-two patients (51%) were available for long-term follow-up at an average of 5.3 years (0.7-10.2 years), and participated in patient reported outcomes (PRO) surveys. The mean Quick Disabilities of the Arm, Shoulder, and Hand score was 16.6, and numeric pain rating scale score was 1.8. CONCLUSIONS: Parallel K-wire placement across the midcarpal joints with scaphoid leads to a high rate of fusion with good patient outcomes long term. Midcarpal settling that occurs through dynamic compression around the K-wires may have contributed to bony fusion. This technique may provide an alternative approach to achieving reliable fusion across the midcarpal joints.


Assuntos
Fios Ortopédicos , Osso Escafoide , Humanos , Pessoa de Meia-Idade , Articulação do Punho/cirurgia , Estudos Retrospectivos , Artrodese/métodos , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA