Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Part Fibre Toxicol ; 13(1): 34, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27328692

RESUMO

BACKGROUND: Graphene, a monolayer of carbon, is an engineered nanomaterial (ENM) with physical and chemical properties that may offer application advantages over other carbonaceous ENMs, such as carbon nanotubes (CNT). The goal of this study was to comparatively assess pulmonary and systemic toxicity of graphite nanoplates, a member of the graphene-based nanomaterial family, with respect to nanoplate size. METHODS: Three sizes of graphite nanoplates [20 µm lateral (Gr20), 5 µm lateral (Gr5), and <2 µm lateral (Gr1)] ranging from 8-25 nm in thickness were characterized for difference in surface area, structure,, zeta potential, and agglomeration in dispersion medium, the vehicle for in vivo studies. Mice were exposed by pharyngeal aspiration to these 3 sizes of graphite nanoplates at doses of 4 or 40 µg/mouse, or to carbon black (CB) as a carbonaceous control material. At 4 h, 1 day, 7 days, 1 month, and 2 months post-exposure, bronchoalveolar lavage was performed to collect fluid and cells for analysis of lung injury and inflammation. Particle clearance, histopathology and gene expression in lung tissue were evaluated. In addition, protein levels and gene expression were measured in blood, heart, aorta and liver to assess systemic responses. RESULTS: All Gr samples were found to be similarly composed of two graphite structures and agglomerated to varying degrees in DM in proportion to the lateral dimension. Surface area for Gr1 was approximately 7-fold greater than Gr5 and Gr20, but was less reactive reactive per m(2). At the low dose, none of the Gr materials induced toxicity. At the high dose, Gr20 and Gr5 exposure increased indices of lung inflammation and injury in lavage fluid and tissue gene expression to a greater degree and duration than Gr1 and CB. Gr5 and Gr20 showed no or minimal lung epithelial hypertrophy and hyperplasia, and no development of fibrosis by 2 months post-exposure. In addition, the aorta and liver inflammatory and acute phase genes were transiently elevated in Gr5 and Gr20, relative to Gr1. CONCLUSIONS: Pulmonary and systemic toxicity of graphite nanoplates may be dependent on lateral size and/or surface reactivity, with the graphite nanoplates > 5 µm laterally inducing greater toxicity which peaked at the early time points post-exposure relative to the 1-2 µm graphite nanoplate.


Assuntos
Grafite/toxicidade , Pulmão/efeitos dos fármacos , Nanopartículas , Nanoestruturas/toxicidade , Animais , Líquido da Lavagem Broncoalveolar , Pulmão/metabolismo , Camundongos , Microscopia Eletrônica de Varredura , RNA Mensageiro/metabolismo
2.
J Toxicol Environ Health A ; 76(11): 651-68, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23941635

RESUMO

Exposure to wet aerosols generated during use of spray products containing silver (Ag) has not been evaluated. The goal was to assess the potential for cardiopulmonary toxicity following an acute inhalation of wet silver colloid. Rats were exposed by inhalation to a low concentration (100 µg/m(3) ) using an undiluted commercial antimicrobial product (20 mg/L total silver; approximately 33 nm mean aerodynamic diameter [MAD]) or to a higher concentration (1000 µg/m(3)) using a suspension (200 mg/L total silver; approximately 39 nm MAD) synthesized to possess a similar size distribution of Ag nanoparticles for 5 h. Estimated lung burdens from deposition models were 0, 1.4, or 14 µg Ag/rat after exposure to control aerosol, low, and high doses, respectively. At 1 and 7 d postexposure, the following parameters were monitored: pulmonary inflammation, lung cell toxicity, alveolar air/blood barrier damage, alveolar macrophage activity, blood cell differentials, responsiveness of tail artery to vasoconstrictor or vasodilatory agents, and heart rate and blood pressure in response to isoproterenol or norepinephrine, respectively. Changes in pulmonary or cardiovascular parameters were absent or nonsignificant at 1 or 7 d postexposure with the exceptions of increased blood monocytes 1 d after high-dose Ag exposure and decreased dilation of tail artery after stimulation, as well as elevated heart rate in response to isoproterenol 1 d after low-dose Ag exposure, possibly due to bioavailable ionic Ag in the commercial product. In summary, short-term inhalation of nano-Ag did not produce apparent marked acute toxicity in this animal model.


Assuntos
Lesão Pulmonar Aguda/induzido quimicamente , Anti-Infecciosos/toxicidade , Sistema Cardiovascular/efeitos dos fármacos , Pulmão/efeitos dos fármacos , Nanopartículas Metálicas/toxicidade , Compostos de Prata/toxicidade , Lesão Pulmonar Aguda/metabolismo , Administração por Inalação , Aerossóis , Animais , Anti-Infecciosos/farmacocinética , Artérias/efeitos dos fármacos , Artérias/fisiopatologia , Cardiotônicos/farmacologia , Coloides , Hemodinâmica , Isoproterenol , Pulmão/metabolismo , Masculino , Norepinefrina , Tamanho da Partícula , Ratos , Ratos Sprague-Dawley , Compostos de Prata/farmacocinética , Vasoconstritores
3.
Xenobiotica ; 42(12): 1170-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22725664

RESUMO

The Phase 2 drug metabolism of busulfan yields a glutathione conjugate that undergoes a ß-elimination reaction. The elimination product is an electrophilic metabolite that is a dehydroalanine-containing tripeptide, γ-glutamyldehydroalanylglycine (EdAG). In the process, glutathione lacks thiol-related redox properties and gains a radical scavenging dehydroalanine group. EdAG scavenged hydroxyl radical generated in the Fenton reaction in a concentration-dependent manner was monitored by electron paramagnetic resonance (EPR) spectroscopy. The apparent rate of hydroxyl radical scavenging was in the same range as published values for known antioxidants, including N-acyl dehydroalanines. A captodatively stabilized carbon-centered radical intermediate was spin trapped in the reaction of EdAG with hydroxyl radical. The proposed structure of a stable product in the Fenton reaction with EdAG was consistent with that of a γ-glutamylserylglycyl dimer. Observation of the hydroxyl trapping properties of EdAG suggests that the busulfan metabolite EdAG may contribute to or mitigate redox-related cytotoxicity associated with the therapeutic use of busulfan, and reaffirms indicators that support a role in free radical biology for dehydroalanine-containing peptides and proteins.


Assuntos
Alanina/análogos & derivados , Bussulfano/metabolismo , Glutationa/metabolismo , Radical Hidroxila/metabolismo , Alanina/metabolismo , Antioxidantes/metabolismo , Biocatálise , Bussulfano/química , Cromatografia Líquida , Óxidos N-Cíclicos/metabolismo , Espectroscopia de Ressonância de Spin Eletrônica , Glutationa Transferase/metabolismo , Peróxido de Hidrogênio/química , Radical Hidroxila/química , Ferro/química , Cinética , Oxirredução , Piridinas/metabolismo , Espectrometria de Massas em Tandem
4.
J Toxicol Environ Health A ; 74(21): 1381-96, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21916744

RESUMO

COREXIT EC9500A (COREXIT) was used to disperse crude oil during the 2010 Deepwater Horizon oil spill. While the environmental impact of COREXIT has been examined, the pulmonary effects are unknown. Investigations were undertaken to determine whether inhaled COREXIT elicits airway inflammation, alters pulmonary function or airway reactivity, or exerts pharmacological effects. Male rats were exposed to COREXIT (mean 27 mg/m(3), 5 h). Bronchoalveolar lavage was performed on d 1 and 7 postexposure. Lactate dehydrogenase (LDH) and albumin were measured as indices of lung injury; macrophages, neutrophils, lymphocytes, and eosinophils were quantified to evaluate inflammation; and oxidant production by macrophages and neutrophils was measured. There were no significant effects of COREXIT on LDH, albumin, inflammatory cell levels or oxidant production at either time point. In conscious animals, neither breathing frequency nor specific airway resistance were altered at 1 hr, 1 d and 7 d postexposure. Airway resistance responses to methacholine (MCh) aerosol in anesthetized animals were unaffected at 1 and 7 d postexposure, while dynamic compliance responses were decreased after 1 d but not 7 d. In tracheal strips, in the presence or absence of MCh, low concentrations of COREXIT (0.001% v/v) elicited relaxation; contraction occurred at 0.003-0.1% v/v. In isolated, perfused trachea, intraluminally applied COREXIT produced similar effects but at higher concentrations. COREXIT inhibited neurogenic contractile responses of strips to electrical field stimulation. Our findings suggest that COREXIT inhalation did not initiate lung inflammation, but may transiently increase the difficulty of breathing.


Assuntos
Emulsificantes/toxicidade , Recuperação e Remediação Ambiental/efeitos adversos , Exposição por Inalação/efeitos adversos , Lipídeos/toxicidade , Pneumonia/induzido quimicamente , Resistência das Vias Respiratórias/efeitos dos fármacos , Albuminas/metabolismo , Animais , Lavagem Broncoalveolar , Líquido da Lavagem Broncoalveolar/química , Líquido da Lavagem Broncoalveolar/citologia , Líquido da Lavagem Broncoalveolar/imunologia , Citocinas/metabolismo , Lactato Desidrogenases/metabolismo , Medições Luminescentes , Masculino , Poluição por Petróleo , Pneumonia/metabolismo , Ratos , Ratos Sprague-Dawley , Espécies Reativas de Oxigênio/metabolismo , Testes de Função Respiratória , Testes de Toxicidade Aguda , Traqueia/efeitos dos fármacos
5.
Part Fibre Toxicol ; 7: 32, 2010 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-21047424

RESUMO

BACKGROUND: Welding fumes consist of a wide range of complex metal oxide particles which can be deposited in all regions of the respiratory tract. The welding aerosol is not homogeneous and is generated mostly from the electrode/wire. Over 390,000 welders were reported in the U.S. in 2008 while over 1 million full-time welders were working worldwide. Many health effects are presently under investigation from exposure to welding fumes. Welding fume pulmonary effects have been associated with bronchitis, metal fume fever, cancer and functional changes in the lung. Our investigation focused on the generation of free radicals and reactive oxygen species from stainless and mild steel welding fumes generated by a gas metal arc robotic welder. An inhalation exposure chamber located at NIOSH was used to collect the welding fume particles. RESULTS: Our results show that hydroxyl radicals (.OH) were generated from reactions with H2O2 and after exposure to cells. Catalase reduced the generation of .OH from exposed cells indicating the involvement of H2O2. The welding fume suspension also showed the ability to cause lipid peroxidation, effect O2 consumption, induce H2O2 generation in cells, and cause DNA damage. CONCLUSION: Increase in oxidative damage observed in the cellular exposures correlated well with .OH generation in size and type of welding fumes, indicating the influence of metal type and transition state on radical production as well as associated damage. Our results demonstrate that both types of welding fumes are able to generate ROS and ROS-related damage over a range of particle sizes; however, the stainless steel fumes consistently showed a significantly higher reactivity and radical generation capacity. The chemical composition of the steel had a significant impact on the ROS generation capacity with the stainless steel containing Cr and Ni causing more damage than the mild steel. Our results suggest that welding fumes may cause acute lung injury. Since type of fume generated, particle size, and elapsed time after generation of the welding exposure are significant factors in radical generation and particle deposition these factors should be considered when developing protective strategies.


Assuntos
Poluentes Ocupacionais do Ar/toxicidade , Espécies Reativas de Oxigênio/metabolismo , Fumaça , Aço , Soldagem , Poluentes Ocupacionais do Ar/química , Animais , Linhagem Celular , Dano ao DNA/efeitos dos fármacos , Exposição por Inalação , Peroxidação de Lipídeos/efeitos dos fármacos , Pulmão/efeitos dos fármacos , Pulmão/patologia , Camundongos , Consumo de Oxigênio/efeitos dos fármacos , Tamanho da Partícula , Espécies Reativas de Oxigênio/química , Aço Inoxidável , Fatores de Tempo
6.
Environ Health Insights ; 8(Suppl 1): 21-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25452695

RESUMO

Processing and synthesis of purified nanomaterials of diverse composition, size, and properties is an evolving process. Studies have demonstrated that some nanomaterials have potential toxic effects and have led to toxicity research focusing on nanotoxicology. About two million workers will be employed in the field of nanotechnology over the next 10 years. The unknown effects of nanomaterials create a need for research and development of techniques to identify possible toxicity. Through a cooperative effort between National Institute for Occupational Safety and Health and IBM to address possible occupational exposures, silicon-based nanowires (SiNWs) were obtained for our study. These SiNWs are anisotropic filamentary crystals of silicon, synthesized by the vapor-liquid-solid method and used in bio-sensors, gas sensors, and field effect transistors. Reactive oxygen species (ROS) can be generated when organisms are exposed to a material causing cellular responses, such as lipid peroxidation, H2O2 production, and DNA damage. SiNWs were assessed using three different in vitro environments (H2O2, RAW 264.7 cells, and rat alveolar macrophages) for ROS generation and possible toxicity identification. We used electron spin resonance, analysis of lipid peroxidation, measurement of H2O2 production, and the comet assay to assess generation of ROS from SiNW and define possible mechanisms. Our results demonstrate that SiNWs do not appear to be significant generators of free radicals.

7.
Environ Health Insights ; 8(Suppl 1): 63-74, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25861220

RESUMO

INTRODUCTION: Oil spill cleanup workers come into contact with numerous potentially hazardous chemicals derived from the oil spills, as well as chemicals applied for mitigation of the spill, including oil dispersants. In response to the Deepwater Horizon Macondo well oil spill in the Gulf of Mexico in 2010, a record volume of the oil dispersant, COREXIT EC9500A, was delivered via aerial applications, raising concern regarding potential health effects that may result from pulmonary exposure to the dispersant. METHODS: The current study examined the effects on pulmonary functions, cardiovascular functions, and systemic immune responses in rats to acute repeated inhalation exposure of COREXIT EC9500A at 25 mg/m(3), five hours per day, over nine work days, or filtered air (control). At one and seven days following the last exposure, a battery of parameters was measured to evaluate lung function, injury, and inflammation; cardiovascular function; peripheral vascular responses; and systemic immune responses. RESULTS: No significant alterations in airway reactivity were observed at one or seven days after exposure either in baseline values or following methacholine (MCh) inhalation challenge. Although there was a trend for an increase in lung neutrophils and phagocyte oxidant production at one-day post exposure, there were no significant differences in parameters of lung inflammation. In addition, increased blood monocytes and neutrophils, and decreased lymphocyte numbers at one-day post exposure also did not differ significantly from air controls, and no alterations in splenocyte populations, or serum or spleen immunoglobulin M (IgM) to antigen were observed. There were no significant differences in peripheral vascular responsiveness to vasoconstrictor and vasodilator agonists or in blood pressure (BP) responses to these agents; however, the baseline heart rate (HR) and HR responses to isoproterenol (ISO) were significantly elevated at one-day post exposure, with resolution by day 7. CONCLUSIONS: In summary, acute repeated exposure to COREXIT EC9500A did not alter pulmonary function, lung injury/inflammation, systemic immune responses, or vascular tone, but did cause transient chronotropic effects on cardiac function.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA