Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Cardiovasc Electrophysiol ; 30(12): 2668-2677, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31552703

RESUMO

BACKGROUND: Mapping and ablation of localized reentry atrial tachycardia (AT) can be challenging, especially in those with varying cycle length (CL). OBJECTIVE: We attempted to use the traditional maneuver of overdrive pacing to facilitate AT mapping. METHODS: Data were collected from 12 patients with localized ATs. All patients had prior cardiac surgery or prior atrial fibrillation ablation. Overdrive pacing mapping (ODPM) was performed to find independent local activity (ILA) and compared with conventional activation mapping (CAM) during ongoing AT to determine its accuracy and efficacy. Patients with macro-reentry AT around the tricuspid or mitral annulus were excluded. RESULTS: Twelve patients with 14 localized ATs were included. All 14 ATs including 4 (29%) with varying CL successfully completed ODPM and had the ILA, although two ATs terminated during ODP and required repeated mapping. Radiofrequency ablation focused on critical sites with ILA was successful in all 12 patients. Using CAM, however, 6 of 14 ATs (43%) mapping attempts were aborted due to AT termination (2 ATs) or varying CL (4 ATs), and only 5 of 8 (63%) located "critical sites" were ultimately confirmed by entrainment and ablation results. After 25 ± 9 months of follow-up, no patient had AT recurrence. CONCLUSION: Our preliminary results demonstrated that ODPM is superior to CAM in ATs that were poorly sustained or with varying CL and is a useful supplement to CAM.


Assuntos
Potenciais de Ação , Remodelamento Atrial , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Taquicardia Supraventricular/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Dados Preliminares , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento
2.
Heart Rhythm ; 3(2): 148-54, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16443528

RESUMO

BACKGROUND: Atrioventricular (AV) delay optimization can be an important determinant of the response to cardiac resynchronization therapy (CRT) in patients with medically refractory heart failure and a ventricular conduction delay. OBJECTIVES: The purpose of this study was to compare two Doppler echocardiographic methods of AV delay optimization after CRT. METHODS: Forty consecutive patients (age 59 +/- 12 years) with severe heart failure, New York Heart Association class 3.1 +/- 0.4, QRS duration 177 +/- 23 ms, and left ventricular ejection fraction 26% +/- 6% referred for CRT were studied using two-dimensional Doppler echocardiography. In each patient, the acute improvement in stroke volume with CRT in response to two methods of AV delay optimization was compared. In the first method, the AV delay that produced the largest increase in the aortic velocity time integral (VTI) derived from continuous-wave Doppler (aortic VTI method) was measured. In the second method, the AV delay that optimized the timing of mitral valve closure to occur simultaneously with the onset of left ventricular systole was calculated from pulsed Doppler mitral waveforms at a short and long AV delay interval (mitral inflow method). RESULTS: The optimized AV delay determined by the aortic VTI method resulted in an increase in aortic VTI of 19% +/- 13% compared with an increase of 12% +/- 12% by the mitral inflow method (P <.001). The optimized AV delay by the aortic VTI method was significantly longer than the optimized AV delay calculated from the mitral inflow method (119 +/- 34 ms vs 95 +/- 24 ms, P <.001). There was no correlation in the AV delay determined by the two methods (r = 0.03). CONCLUSION: AV delay optimization by Doppler echocardiography for patients with severe heart failure treated with a CRT device yields a greater systolic improvement when guided by the aortic VTI method compared with the mitral inflow method.


Assuntos
Nó Atrioventricular/diagnóstico por imagem , Nó Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial , Ecocardiografia Doppler , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA