Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pulm Pharmacol Ther ; 53: 27-32, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30201410

RESUMO

BACKGROUND: Delivery of inhaled respiratory medications have been associated with variable delivery of drug due to errors in device operations and have not been designed to monitor true delivery of medication. A fully digital breath-activated inhaled (DBAI) delivery platform has been developed with integrated firmware and software to address these limitations. METHODS: the device was designed to produce similar aerosol particle output to a marketed albuterol MDI and to the albuterol/ipratropium combination in a soft mist inhaler (SMI). Cascade impactor studies were conducted to demonstrate comparable aerodynamic particle size distribution (APSD) metrics. Efficacy was evaluated by pharmacodynamic studies involving spirometry in two separate protocols with adult subjects having COPD (albuterol DBAI vs. albuterol MDI - Study A, albuterol/ipratropium DBAI single arm - Study B). RESULTS: The total emitted doses (TED) were 81.9 ±â€¯10.3, 109.3 ±â€¯15.0 and 121.9 ±â€¯7.0 µg/actuation for the DBAI, SMI and MDI respectively, and the fine (respirable) particle doses (FPD) were 56.2 ±â€¯6.0, 61.7 ±â€¯5.5 and 79.4 ±â€¯2.7 µg/actuation. MMADs for albuterol sulfate were 1.93 ±â€¯0.11, 1.75 ±â€¯0.19, and 2.65 ±â€¯0.05 µm for the DBAI, Respimat soft mist inhaler (SMI) and MDI respectively. The corresponding GSDs were 1.96 ±â€¯0.16, 2.79 ±â€¯0.25, and 1.48 ±â€¯0.02 µm. The corresponding respirable fractions were 68.7 ±â€¯3.2%, 57.3 ±â€¯10.5%, and 65.2 ±â€¯2.4%. Spirometric study A enrolled 23 subjects (age 64 ±â€¯7.3 years, 39% male, FEV1 45 ±â€¯14% predicted). Study B enrolled 23 subjects (age 65 ±â€¯8.6 years, 43% male, FEV1 47 ±â€¯10% predicted). For Study A, FEV1 at 20 min post-dose improved by 120 (167) mL (p = 0.002) for the DBAI device and 109 (183) mL (p = 0.008) for the MDI device (p = 0.86 for between group differences). For Study B, FEV1 (20 min post-dose) improved by 216 (126) mL (p < 0.001). CONCLUSION: The DBAI generated highly respirable aerosols containing albuterol sulfate that were similar to the MDI and SMI in respirable fraction but lower in dose. Subsequent pharmacodynamic studies delivering albuterol sulfate alone and in combination with ipratropium bromide confirmed similar responses for the DBAI compared with the other inhalers, which could possibly be related to a response ceiling. The DBAI breath-activated capability combined with the ability to monitor actual delivery of medication may improve effectiveness by overcoming patient miscoordination.


Assuntos
Albuterol/administração & dosagem , Sistemas de Liberação de Medicamentos , Ipratrópio/administração & dosagem , Inaladores Dosimetrados , Administração por Inalação , Aerossóis , Idoso , Broncodilatadores/administração & dosagem , Combinação de Medicamentos , Desenho de Equipamento , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho da Partícula , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Espirometria , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 89(2): 169-177, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27148802

RESUMO

OBJECTIVE: To assess safety and feasibility of autologous adipose-derived regenerative cells (ADRCs), for treatment of chronic ischemic cardiomyopathy patients. BACKGROUND: Preclinical and early clinical trials suggest ADRCs have excellent potential for ischemic conditions. METHODS: The Athena program consisted of two parallel, prospective, randomized (2:1, active: placebo), double-blind trials assessing intramyocardial (IM) ADRC delivery [40-million, n = 28 (ATHENA) and 80-million (ATHENA II) cells, n = 3]). Patients with an EF ≥20% but ≤45%, multivessel coronary artery disease (CAD) not amenable to revascularization, inducible ischemia, and symptoms of either angina (CCS II-IV) or heart failure (NYHA Class II-III) on maximal medical therapy were enrolled. All patients underwent fat harvest procedure (≤450 mL adipose), on-site cell processing (Celution® System, Cytori Therapeutics), electromechanical mapping, and IM delivery of ADRCs or placebo. RESULTS: Enrollment was terminated prematurely due to non-ADRC-related adverse events and subsequent prolonged enrollment time. Thirty-one patients (17-ADRCs, 14-placebo) mean age 65 ± 8 years, baseline LVEF(%) 31.1 ± 8.7 (ADRC), 31.8 ± 7.7 (placebo) were enrolled. Change in V02 max favored ADRCs (+45.4 ± 222 vs. -9.5 ± 137 mL/min) but there was no difference in left ventricular function or volumes. At 12-months, heart failure hospitalizations occurred in 2/17 (11.7%) [ADRC] and 3/14 (21.4%) [placebo]. Differences in NYHA and CCS classes favored ADRCs at 12-months with significant improvement in MLHFQ (-21.6 + 13.9 vs. -5.5 + 23.8, P = 0.038). CONCLUSIONS: A small volume fat harvest, automated local processing, and IM delivery of autologous ADRCs is feasible with suggestion of benefit in "no option" CAD patients. Although the sample size is limited, the findings support feasibility and scalability for treatment of ischemic cardiomyopathy with ADRCs. © 2016 Wiley Periodicals, Inc.


Assuntos
Tecido Adiposo/citologia , Isquemia Miocárdica/cirurgia , Miocárdio/patologia , Regeneração , Transplante de Células-Tronco , Disfunção Ventricular Esquerda/cirurgia , Função Ventricular Esquerda , Idoso , Doença Crônica , Progressão da Doença , Método Duplo-Cego , Término Precoce de Ensaios Clínicos , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/patologia , Isquemia Miocárdica/fisiopatologia , Readmissão do Paciente , Estudos Prospectivos , Recuperação de Função Fisiológica , Transplante de Células-Tronco/efeitos adversos , Volume Sistólico , Fatores de Tempo , Transplante Autólogo , Resultado do Tratamento , Estados Unidos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia
3.
Surg Technol Int ; 29: 38-44, 2016 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-27466873

RESUMO

Adipose derived regenerative cells (ADRCs) are a heterogeneous population of cells including multipotent adipose derived stems cells, other progenitor cells, fibroblasts, T-regulatory cells, and macrophages. Preclinical data exist supporting benefits that are predominantly through angiogenesis, modulation of inflammation, and wound remodeling. Such effects are likely paracrine in nature. The application of autologous ADRCs has been investigated across multiple therapeutic areas. While there are numerous publications, there is a relative lack of double-blind, well-controlled, randomized clinical trials in the literature. Nevertheless, a consistency in outcomes and a consistency with preclinical and laboratory studies suggests a true positive effect. The therapeutic areas reported include orthopedics, autoimmune disease, wounds and reconstruction, cardiology, peripheral vascular disease, genitourinary disorders, gastrointestinal fistulas, and neurology. Case reports have documented wound healing in otherwise intractable wounds such as ischemic- and radiation-related cutaneous ulcers and enterocutaneous fistulas. An open label, 12-patient-study indicated substantial improvement in hand manifestations of scleroderma across multiple endpoints. Post-radical prostatectomy urinary incontinence improved in a study of 11 patients with local delivery of ADRCs. Small studies of intramyocardial delivery have been associated with trends towards benefit. The studies also indicate that same day fat harvest through liposuction, cell processing, and cell delivery is feasible and can be performed with an acceptable safety profile. The objective of this review is to highlight the interest, potential, and trends that support the need to continue evaluation and exploration for the role of ADRCs as a therapeutic agent.


Assuntos
Tecido Adiposo/citologia , Transplante de Células-Tronco , Humanos , Masculino , Ensaios Clínicos Controlados Aleatórios como Assunto , Cicatrização
4.
Respiration ; 85(6): 493-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23549057

RESUMO

BACKGROUND: A method of achieving endoscopic lung volume reduction for emphysema has been developed that utilizes precise amounts of thermal energy in the form of water vapor to ablate lung tissue. OBJECTIVE: This study evaluates the energy output and implications of the commercial InterVapor system and compares it to the clinical trial system. METHODS: Two methods of evaluating the energy output of the vapor systems were used, a direct energy measurement and a quantification of resultant thermal profile in a lung model. Direct measurement of total energy and the component attributable to gas (vapor energy) was performed by condensing vapor in a water bath and measuring the temperature and mass changes. Infrared images of a lung model were taken after vapor delivery. The images were quantified to characterize the thermal profile. RESULTS: The total energy and vapor energy of the InterVapor system was measured at various dose levels and compared to the clinical trial system at a dose of 10.0 cal/g. An InterVapor dose of 8.5 cal/g was found to have the most similar vapor energy output with the smallest associated reduction in total energy. This was supported by characterization of the thermal profile in the lung model that demonstrated the profile of InterVapor at 8.5 cal/g to not exceed the profile of the clinical trial system. CONCLUSIONS: Considering both total energy and vapor energy is important during the development of clinical vapor applications. For InterVapor, a closer study of both energy types justified a reduced target vapor-dosing range for lung volume reduction. The clinical implication is a potential improvement for benefiting the risk profile.


Assuntos
Técnicas de Ablação/instrumentação , Enfisema/cirurgia , Modelos Químicos , Pneumonectomia/métodos , Vapor , Ensaios Clínicos como Assunto , Temperatura Alta , Humanos
5.
Respiration ; 86(4): 324-31, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23988888

RESUMO

BACKGROUND: Bronchoscopic thermal vapor ablation (BTVA) reduces lung volumes in emphysema patients by inducing a localized inflammatory response (LIR) leading to a healing process of fibrosis, but may also increase symptoms. OBJECTIVES: We sought to evaluate whether the clinical manifestation of LIR correlated with patient outcome. METHODS: Respiratory adverse events and inflammatory markers were analyzed from a multicenter trial of BTVA in patients with upper-lobe-predominant emphysema. End points including changes in forced expiratory flow (FEV1), lobar volume, St. George's Respiratory Questionnaire (SGRQ), modified Medical Research Council (mMRC) and 6-minute-walk distance (6-MWD) were analyzed according to the presence or absence of a respiratory adverse event requiring treatment with an antibiotic or steroid. RESULTS: Forty-four patients received BTVA. Increases of inflammatory markers were observed with a peak between the second and fourth week. Eighteen respiratory adverse events occurred in 16 patients within 30 days of BTVA, requiring antibiotics and/or steroids. These patients had significantly greater lobar volume reduction (65.3 vs. 33.4%, p = 0.007) and a change in residual volume at 12 months (-933 vs. 13 ml, p < 0.001) associated with a greater improvement of exercise capacity and health-related quality of life than patients without respiratory adverse events. CONCLUSION: Patients with more prominent respiratory symptoms in the first 30 days following BTVA experience greater efficacy. The clinical manifestations of the LIR are predictive of long-term clinical benefits.


Assuntos
Técnicas de Ablação/efeitos adversos , Broncoscopia/efeitos adversos , Enfisema/cirurgia , Pneumonia/etiologia , Ensaios Clínicos como Assunto , Humanos , Pulmão/patologia , Tamanho do Órgão , Resultado do Tratamento
6.
Eur Respir J ; 39(6): 1326-33, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22075481

RESUMO

The need for a less invasive procedure than surgical lung volume reduction that can produce consistent improvements with reduced morbidity remains a medical goal in patients with emphysema. We sought to determine the effect of bronchoscopic thermal vapour ablation (BTVA) on lung volumes and outcomes in patients with emphysema. 44 patients with upper lobe-predominant emphysema were treated unilaterally with BTVA. Entry criteria included: age 40-75 yrs, forced expiratory volume in 1 s (FEV(1)) 15-45% predicted, previous pulmonary rehabilitation and a heterogeneity index (tissue/air ratio of lower lobe/upper lobe) from high-resolution computed tomography (HRCT) ≥ 1.2. Changes in FEV(1), St George's Respiratory Questionnaire (SGRQ), 6-min walk distance (6 MWD), modified Medical Research Council (mMRC) dyspnoea score, and hyperinflation were measured at baseline, and 3 and 6 months post-BTVA. At 6 months, mean ± SE FEV(1) improved by 141 ± 26 mL (p<0.001) and residual volume was reduced by 406 ± 113 mL (p<0.0001). SGRQ total score improved by 14.0 ± 2.4 points (p<0.001), with 73% improving by ≥ 4 points. Improvements were observed in 6 MWD (46.5 ± 10.6 m) and mMRC dyspnoea score (0.9 ± 0.2) (p<0.001 for both). Lower respiratory events (n=11) were the most common adverse event and occurred most often during the initial 30 days. BTVA therapy results in clinically relevant improvements in lung function, quality of life and exercise tolerance in upper lobe predominant emphysema.


Assuntos
Técnicas de Ablação/métodos , Broncoscopia/métodos , Pneumonectomia/métodos , Enfisema Pulmonar/cirurgia , Adulto , Idoso , Broncoscopia/efeitos adversos , Dispneia/cirurgia , Tolerância ao Exercício/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonectomia/efeitos adversos , Qualidade de Vida , Testes de Função Respiratória , Inquéritos e Questionários , Resultado do Tratamento
7.
Respir Res ; 13: 66, 2012 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-22866681

RESUMO

BACKGROUND: The changes in inspiratory capacity (IC) over time in chronic obstructive pulmonary disease (COPD) patients are unknown. The Understanding Potential Long-term Impacts on Function with Tiotropium (UPLIFT®) trial included IC measurements. METHODS: IC analysis from UPLIFT® (N = 5992) was performed at 1 and 6 months, and every 6 months through 4 years. Annualized rate of decline in pre- and post-bronchodilator IC and mean differences at each time point were analyzed by mixed-effects models. The relationships between baseline IC and exacerbation rate and mortality were explored using Cox regression analysis. RESULTS: Baseline characteristics: age, 65 years; 75% men; post-bronchodilator forced expiratory volume in 1 second, 1.32 L (48% predicted); pre- and post-bronchodilator IC, 2.03 and 2.33 L. Mean IC rate of decline (mL/year) was 34 ± 2 (1.7% of baseline) and 50 ± 3 (2.1% of baseline) pre- and post-bronchodilator, respectively, without significant between-group differences. Morning pre-bronchodilator (trough) IC improved with tiotropium versus placebo: 124 mL (1 month), 103 mL (1 year), 107 mL (2 years), 98 mL (3 years), and 97 mL (4 years) (all p < 0.001). Post-bronchodilator improvements were similar between treatment groups. Lower baseline IC values were associated with reduced time to first exacerbation. For the lowest quartile (n = 1413) the values in months were 14.3 (11.7-17.0) for tiotropium and 10.3 (8.8-11.7) for controls (p < 0.01). CONCLUSION: IC declines from approximately 34 to 50 mL/year in patients with stage II to IV COPD. Tiotropium treatment does not change the IC decline rate but provides 24-hour improvements in IC sustained over the long term. Trough IC differences suggest that tiotropium provides sustained decrease in end-expiratory lung volume.


Assuntos
Progressão da Doença , Capacidade Inspiratória/fisiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Idoso , Broncodilatadores/farmacologia , Broncodilatadores/uso terapêutico , Feminino , Volume Expiratório Forçado/efeitos dos fármacos , Volume Expiratório Forçado/fisiologia , Humanos , Capacidade Inspiratória/efeitos dos fármacos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/mortalidade , Análise de Regressão , Derivados da Escopolamina/farmacologia , Derivados da Escopolamina/uso terapêutico , Índice de Gravidade de Doença , Brometo de Tiotrópio
8.
Int J Hyperthermia ; 28(5): 466-72, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22690896

RESUMO

PURPOSE: An investigation of the thermal effect and the potential for injury at the lung surface following thermal vapour ablation (InterVapor), an energy-based method of achieving endoscopic lung volume reduction. METHODS: Heated water vapour was delivered to fifteen ex vivo human lungs using standard clinical procedure, and the thermal effect at the visceral pleura was monitored with an infrared camera. The time-temperature response was analysed mathematically to determine a cumulative injury quotient, which was compared to published thresholds. RESULTS: The cumulative injury quotients for all 71 treatments of ex vivo tissue were found to be below the threshold for first degree burn and no other markers of tissue injury at the lung surface were observed. CONCLUSION: The safety profile for thermal vapour ablation is further supported by the demonstration that the thermal effect in a worst-case model is not expected to cause injury at the lung surface.


Assuntos
Técnicas de Ablação/efeitos adversos , Hipertermia Induzida/efeitos adversos , Lesão Pulmonar/etiologia , Técnicas de Ablação/métodos , Temperatura Corporal , Endoscopia , Temperatura Alta , Humanos , Hipertermia Induzida/métodos
9.
Respiration ; 83(5): 400-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22377613

RESUMO

BACKGROUND: Bronchoscopic thermal vapor ablation (BTVA) ablates emphysematous tissue through a localized inflammatory response followed by contractive fibrosis and tissue shrinkage leading to lung volume reduction that should not be influenced by collateral ventilation. OBJECTIVES: To determine the correlation of clinical data from a trial of BTVA with fissure integrity visually assessed by computed tomography (CT). METHODS: We conducted a single-arm study of patients with upper lobe-predominant emphysema (n = 44). Patients received BTVA either to the right upper lobe or left upper lobe, excluding the lingula. Primary efficacy outcomes were forced expiratory volume in 1 s (FEV(1)) and St. George's Respiratory Questionnaire (SGRQ) at 6 months. Lobar volume reduction from CT was another efficacy outcome measurement. The fissure of the treated lobe was analyzed visually on preinterventional CT. Incompleteness of the small fissure, the upper half of the right large fissure and the whole left large fissure were estimated visually in 5% increments, and the relative amount of fissure incompleteness was calculated. Pearson correlation coefficients were calculated for the association between fissure incompleteness and change in efficacy outcomes (baseline to 6 months) of BTVA. RESULTS: A total of 38 out of 44 patients (86%) had incompleteness in the relevant fissure. Calculated relevant fissure incompleteness was a mean of 13% of fissure integrity (range 0-63). Correlation coefficients for the association of incompleteness with outcomes were as follows: FEV(1) = 0.17; lung volume reduction = -0.27; SGRQ score = -0.10; 6-min walk distance = 0.0; residual volume (RV) = -0.18, and RV/total lung capacity = -0.14. CONCLUSIONS: Lobar fissure integrity has no or minimal influence on BTVA-induced lung volume reduction and improvements in clinical outcomes.


Assuntos
Técnicas de Ablação/métodos , Broncoscopia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Enfisema Pulmonar/cirurgia , Ensaios Clínicos como Assunto , Tolerância ao Exercício , Volume Expiratório Forçado , Humanos , Tomografia Computadorizada Multidetectores , Volume Residual , Estudos Retrospectivos , Capacidade Pulmonar Total
10.
BMC Pulm Med ; 12: 18, 2012 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-22584018

RESUMO

BACKGROUND: Quantification of lung tissue via analysis of computed tomography (CT) scans is increasingly common for monitoring disease progression and for planning of therapeutic interventions. The current study evaluates the quantification of human lung tissue mass by software analysis of a CT to physical tissue mass measurements. METHODS: Twenty-two ex vivo lungs were scanned by CT and analyzed by commercially available software. The lungs were then dissected into lobes and sublobar segments and weighed. Because sublobar boundaries are not visually apparent, a novel technique of defining sublobar segments in ex vivo tissue was developed. The tissue masses were then compared to measurements by the software analysis. RESULTS: Both emphysematous (n = 14) and non-emphysematous (n = 8) bilateral lungs were evaluated. Masses (Mean ± SD) as measured by dissection were 651 ± 171 g for en bloc lungs, 126 ± 60 g for lobar segments, and 46 ± 23 g for sublobar segments. Masses as measured by software analysis were 598 ± 159 g for en bloc lungs, 120 ± 58 g for lobar segments, and 45 ± 23 g for sublobar segments. Correlations between measurement methods was above 0.9 for each segmentation level. The Bland-Altman analysis found limits of agreement at the lung, lobe and sublobar levels to be -13.11% to -4.22%, -13.59% to 4.24%, and -45.85% to 44.56%. CONCLUSION: The degree of concordance between the software mass quantification to physical mass measurements provides substantial evidence that the software method represents an appropriate non-invasive means to determine lung tissue mass.


Assuntos
Pulmão/anatomia & histologia , Pulmão/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/patologia , Software , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Algoritmos , Feminino , Humanos , Pulmão/cirurgia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Validação de Programas de Computador , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA