Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 103(6): 833-842, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38639137

RESUMO

BACKGROUND: Stent underexpansion, typically related to lesion calcification, is the strongest predictor of adverse events after percutaneous coronary intervention (PCI). Although uncommon, underexpansion may also occur in non-severely calcified lesions. AIM: We sought to identify the prevalence and anatomical characteristics of underexpansion in non-severely calcified lesions. METHODS: We included 993 patients who underwent optical coherence tomography-guided PCI of 1051 de novo lesions with maximum calcium arc <180°. Negative remodeling (NR) was the smallest lesion site external elastic lamina diameter that was also smaller than the distal reference. Stent expansion was evaluated using a linear regression model accounting for vessel tapering; underexpansion required both stent expansion <70% and stent area <4.5mm2. RESULTS: Underexpansion was observed in 3.6% of non-heavily calcified lesions (38/1051). Pre-stent maximum calcium arc and thickness were greater in lesions with versus without underexpansion (median 119° vs. 85°, p = 0.002; median 0.95 mm vs. 0.78 mm, p = 0.008). NR was also more common in lesions with underexpansion (44.7% vs. 24.5%, p = 0.007). In the multivariable logistic regression model, larger and thicker eccentric calcium, mid left anterior descending artery (LAD) location, and NR were associated with underexpansion in non-severely calcified lesions. The rate of underexpansion was especially high (30.7%) in lesions exhibiting all three morphologies. Two-year TLF tended to be higher in underexpanded versus non-underexpanded stents (9.7% vs. 3.7%, unadjusted hazard ratio [95% confidence interval] = 3.02 [0.92, 9.58], p = 0.06). CONCLUSION: Although underexpansion in the absence of severe calcium (<180°) is uncommon, mid-LAD lesions with NR and large and thick eccentric calcium were associated with underexpansion.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Intervenção Coronária Percutânea , Stents , Tomografia de Coerência Óptica , Calcificação Vascular , Humanos , Masculino , Feminino , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Prevalência , Fatores de Risco , Vasos Coronários/diagnóstico por imagem , Resultado do Tratamento , Estudos Retrospectivos , Índice de Gravidade de Doença , Desenho de Prótese , Valor Preditivo dos Testes , Fatores de Tempo , Angiografia Coronária , Remodelação Vascular
3.
Eur Heart J ; 44(43): 4508-4532, 2023 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-37793121

RESUMO

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Índice de Gravidade de Doença
4.
Catheter Cardiovasc Interv ; 99(4): 1268-1276, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35084803

RESUMO

OBJECTIVES: The purpose of this study was to characterize the anatomic relationship between the inferior vena cava (IVC) and tricuspid annulus (TA) and its potential impact on the performance of transcatheter TV interventions. BACKGROUND: Transcatheter tricuspid valve (TV) interventions are emerging as a therapeutic alternative for the treatment of severe, symptomatic tricuspid regurgitation (TR). Progression of TR is associated with right heart dilatation. These anatomic changes may distort the IVC-TA relationship and impact successful implantation of transcatheter devices. METHODS: Fifty patients who presented with symptomatic TR for consideration of transcatheter TV therapy with an available CT were included in the study. Comprehensive transesophageal echocardiogram and CT analyses were performed to assess the right-sided cardiac chambers, TA and IVC-TA relationship. RESULTS: The mean age of the study cohort was 78.4 ± 8.9 years. Torrential TR was present in 54% (n = 27). There was considerable variation in the short axis mid-IVC to mid-TA offset (SAXMID 18.2 ± 7.9 mm, range 4.7-42.1 mm). CONCLUSIONS: The IVC-to-TA relationship exhibits significant variability in patients with symptomatic TR. CT analysis of the tricuspid anatomy, including the relationship to the surrounding structures and the IVC, is essential for planning transcatheter TV interventions. Further studies are needed to define whether the IVC-to-TA relationship is a predictor of technical success in the context of specific transcatheter delivery systems.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Humanos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Veia Cava Inferior/diagnóstico por imagem
5.
J Cardiovasc Magn Reson ; 24(1): 38, 2022 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-35725565

RESUMO

The 25th Society for Cardiovascular Magnetic Resonance (SCMR) Annual Scientific Sessions saw 1524 registered participants from more than 50 countries attending the meeting virtually. Supporting the theme "CMR: Improving Cardiovascular Care Around the World", the meeting included 179 invited talks, 52 sessions including 3 plenary sessions, 2 keynote talks, and a total of 93 cases and 416 posters. The sessions were designed so as to showcase the multifaceted role of cardiovascular magnetic resonance (CMR) in identifying and prognosticating various myocardial pathologies. Additionally, various social networking sessions as well as fun activities were organized. The major areas of focus for the future are likely to be rapid efficient and high value CMR exams, automated and quantitative acquisition and post-processing using artificial intelligence and machine learning, multi-contrast imaging and advanced vascular imaging including 4D flow.


Assuntos
Inteligência Artificial , Sistema Cardiovascular , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
6.
Rev Cardiovasc Med ; 22(4): 1513-1521, 2021 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-34957790

RESUMO

Transthoracic echocardiography (TTE) and Cardiac Magnetic Resonance (CMR) have complementary roles in the severity grading of mitral regurgitation (MR). Our objective was to systematically review the correlation of MR severity as assessed by TTE and CMR. We searched MEDLINE and Cochrane Library for original series published between January 1st, 2000 and March 23rd, 2020. We used Cohen's kappa coefficient to measure agreement between modalities. We plotted a hierarchical summary receiver operator characteristic (HSROC) curve and estimated the area under the curve (AUC) to assess the concordance between the two imaging modalities for the detection of severe MR. We identified 858 studies, of which 65 underwent full-text assessment and 8 were included in the meta-analysis. A total of 718 patients were included (425 males, 59%) in the final analysis. There was significant heterogeneity in the methods used and considerable variation in kappa coefficient, ranging from 0.10 to 0.48. Seven out of eight studies provided the necessary data to plot HSROC curves and calculate the AUC. The AUC for detecting severe MR was 0.83 (95% CI 0.80 to 0.86), whereas the AUC for detecting moderate to severe MR was 0.83 (95% CI 0.79 to 0.86). The agreement between TTE and CMR in MR severity evaluation is modest across the entire spectrum of severity grading. However, when focusing on patients with at least moderate MR the concordance between TTE and CMR is very good. Further prospective studies comparing hard clinical endpoints based on the CMR and TTE assessment of MR severity are needed.


Assuntos
Insuficiência da Valva Mitral , Ecocardiografia/métodos , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
7.
J Card Surg ; 36(7): 2410-2418, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33797788

RESUMO

BACKGROUND AND AIM OF THE STUDY: A systematic approach to quantify mitral annular calcification (MAC) in all-comers by multidetector computed tomography (MDCT) is essential to guide treatment, but lacking. METHODS: From September 2015 to July 2019, 82 patients with MAC underwent MDCT at two institutions to evaluate for surgical mitral valve replacement (SMVR), transcatheter mitral valve replacement (TMVR), or medical management. Type 1 MAC was defined as <270° annular calcium and Type 2 as ≥270°. Absence/presence of predicted left ventricular outflow tract (LVOT) obstruction with virtual valve placement was used to further define Type 2 MAC into 2A/B for our treatment algorithm. RESULTS: Type 1 MAC was present in 51.2%, Type 2A in 18.3%, and Type 2B in 30.5%. Operable Type 1 patients (50.0%) underwent hybrid transatrial TMVR or SMVR. Type 2A underwent a variety of treatments, and Type 2B surgical candidates (40.0%) underwent hybrid transatrial TMVR secondary to difficult suture anchoring with significant MAC and predicted LVOT obstruction. At a follow-up of 29.6 ± 12.0 months, mortality was 42.7% with 46.3% in the intervention group and 39.0% in the medical group (p = 0.47). All percutaneous TMVR patients expired. This translated to a disproportionate number of Type 2A deaths (80.0% with intervention), but all were high/extreme surgical risk. The hybrid TMVR group consisted of 95.0% Type 1/2B patients and had a lower Society of Thoracic Surgeons predicted risk of operative mortality (7.4% vs. 9.2%, p = 0.43)/mortality. CONCLUSIONS: The highest mortality was seen in percutaneous TMVR Type 2A MAC patients, but they were at the greatest risk. Here we provide an objective MAC treatment algorithm for all-comers based on operability/anatomy.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Obstrução do Fluxo Ventricular Externo , Cateterismo Cardíaco , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 95(6): 1178-1183, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31452322

RESUMO

OBJECTIVES: To describe outcomes after suprasternal (SS) transcatheter aortic valve replacement (TAVR) as a new alternative access approach. BACKGROUND: There still remains a cohort of the TAVR population who are not suitable for a transfemoral (TF) approach. SS-TAVR is a safe and effective alternative to TF-TAVR and has now become our preferred alternative access route. METHODS: We retrospectively reviewed all patients from New York Presbyterian Hospital, Columbia University Medical Center and Princeton Baptist Medical Center who underwent SS-TAVR from 2015 to July 2018. A total of 84 patients were included in the study. RESULTS: Technical success was achieved in all cases. Thirty-day survival was 98.8% (n = 83). There were minimal complications. Most notably, there were no transient ischemic attacks or strokes (0%, n = 0). Reexploration for bleeding was 3.6% (n = 3), and major bleeding was 1.7% (n = 1). We also achieved satisfactory results with a mean aortic valve gradient of 6.07 ± 3.79 mmHg and an aortic valve area of 2.21 ± 0.51 cm2 . No patients had anything more than mild paravalvular leak. The mean length of stay (LOS) in the intensive care unit was 1.42 ± 1.23 days, and hospital LOS was 4.20 ± 3.29 days. CONCLUSIONS: SS access for TAVR is an extremely important technique to have in any valve team's alternative access armamentarium. This technique can be safely and reliably reproduced with any standard hybrid operating room setup and no additional equipment, and it can be used with any commercially available valve system. In the current experience, minimal complications and excellent early term results were obtained.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Alabama , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Cidade de Nova Iorque , Complicações Pós-Operatórias/etiologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 93(6): 1152-1160, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30790417

RESUMO

OBJECTIVES: To assess impact of left ventricular (LV) chamber remodeling on MitraClip (MClp) response. BACKGROUND: MitraClip is the sole percutaneous therapy approved for mitral regurgitation (MR) but response varies. LV dilation affects mitral coaptation; determinants of MClp response are uncertain. METHODS: LV and mitral geometry were quantified on pre- and post-procedure two-dimensional (2D) transthoracic echocardiography (TTE) and intra-procedural three-dimensional (3D) transesophageal echocardiography (TEE). Optimal MClp response was defined as ≤mild MR at early (1-6 month) follow-up. RESULTS: Sixty-seven degenerative MR patients underwent MClp: Whereas MR decreased ≥1 grade in 94%, 39% of patients had optimal response (≤mild MR). Responders had smaller pre-procedural LV end-diastolic volume (94 ± 24 vs. 109 ± 25 mL/m2 , p = 0.02), paralleling smaller annular diameter (3.1 ± 0.4 vs. 3.5 ± 0.5 cm, p = 0.002), and inter-papillary distance (2.2 ± 0.7 vs. 2.5 ± 0.6 cm, p = 0.04). 3D TEE-derived annular area correlated with 2D TTE (r = 0.59, p < 0.001) and was smaller among optimal responders (12.8 ± 2.1 cm2 vs. 16.8 ± 4.4 cm2 , p = 0.001). Both 2D and 3D mitral annular size yielded good diagnostic performance for optimal MClp response (AUC 0.73-0.84, p < 0.01). In multivariate analysis, sub-optimal MClp response was associated with LV end-diastolic diameter (OR 3.10 per-cm [1.26-7.62], p = 0.01) independent of LA size (1.10 per-cm2 [1.02-1.19], p = 0.01); substitution of mitral annular diameter for LV size yielded an independent association with MClp response (4.06 per-cm2 [1.03-15.96], p = 0.045). CONCLUSIONS: Among degenerative MR patients undergoing MClp, LV and mitral annular dilation augment risk for residual or recurrent MR, supporting the concept that MClp therapeutic response is linked to sub-valvular remodeling.


Assuntos
Cateterismo Cardíaco/instrumentação , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Cardiovasc Ultrasound ; 17(1): 31, 2019 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-31878931

RESUMO

BACKGROUND: Echocardiography (echo) is widely used to guide therapeutic decision-making for patients being considered for MitraClip. Relative utility of two- (2D) and three-dimensional (3D) echo predictors of MitraClip response, and impact of MitraClip on mitral annular geometry, are uncertain. METHODS: The study population comprised patients with advanced (> moderate) MR undergoing MitraClip. Mitral annular geometry was quantified on pre-procedural 2D transthoracic echocardiography (TTE) and intra-procedural 3D transesophageal echocardiography (TEE); 3D TEE was used to measure MitraClip induced changes in annular geometry. Optimal MitraClip response was defined as ≤mild MR on follow-up (mean 2.7 ± 2.5 months) post-procedure TTE. RESULTS: Eighty patients with advanced MR underwent MitraClip; 41% had optimal response (≤mild MR). Responders had smaller pre-procedural global left ventricular (LV) end-diastolic size and mitral annular diameter on 2D TTE (both p ≤ 0.01), paralleling smaller annular area and circumference on 3D TEE (both p = 0.001). Mitral annular size yielded good diagnostic performance for optimal MitraClip response (AUC 0.72, p < 0.01). In multivariate analysis, sub-optimal MitraClip response was independently associated with larger pre-procedural mitral annular area on 3D TEE (OR 1.93 per cm2/m2 [CI 1.19-3.13], p = 0.007) and global LV end-diastolic volume on 2D TTE (OR 1.29 per 10 ml/m2 [CI 1.02-1.63], p = 0.03). Substitution of 2D TTE derived mitral annular diameter for 3D TEE data demonstrated a lesser association between pre-procedural annular size (OR 5.36 per cm/m2 [CI 0.95-30.19], p = 0.06) and sub-optimal MitraClip response. Matched pre- and post-procedural TEE analyses demonstrated MitraClip to acutely decrease mitral annular area and circumference (all p < 0.001) as well as mitral tenting height, area, and volume (all p < 0.05): Magnitude of MitraClip induced reductions in mitral annular circumference on intra-procedural 3D TEE was greater among patients with, compared to those without, sub-optimal MitraClip response (>mild MR) on followup TTE (p = 0.017); greater magnitude of device-induced annular reduction remained associated with sub-optimal MitraClip response even when normalized for pre-procedure annular circumference (p = 0.028). CONCLUSIONS: MitraClip alters mitral annular geometry as quantified by intra-procedural 3D TEE. Pre-procedural mitral annular dilation and magnitude of device-induced reduction in mitral annular size on 3D TEE are each associated with sub-optimal therapeutic response to MitraClip.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino
11.
Catheter Cardiovasc Interv ; 91(4): 765-773, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28470996

RESUMO

OBJECTIVES: Determine the comparative impact of small prosthesis size on transcatheter and surgical aortic valve replacement (SAVR) outcomes. BACKGROUND: Patients with small aortic annuli tend to have worse postoperative outcomes and hemodynamics. We sought to describe surgical outcomes in patients with very small aortic annuli and then compare early hemodynamic and clinical outcomes in patients undergoing surgical or transcatheter aortic valve replacement (TAVR) with the smallest available valves to assist in optimal prosthesis selection for this challenging patient population. METHODS: A retrospective single-center study comparing patient data from 2143 patients undergoing SAVR with valves having a true internal diameter (ID) of ≥19 mm with 130 patients receiving surgical valves with true ID's <19 mm (SmSAVR). Outcomes of SmSAVR patients were then compared with 40 patients undergoing TAVR receiving small valves (SmTAVR). A representative SmSAVR cohort was then compared with the SmTAVR patients for post-operative hemodynamics. RESULTS: Receiving a small surgical valve may significantly increase 1-year mortality compared with standard-sized surgical valves (HR 1.93; 95% confidence interval 1.03-3.61). SmTAVR patients had significantly shorter lengths of stay than SmSAVR (median 5 vs. 9 days), and significantly better postoperative hemodynamic profiles (mean gradient 13.4 ± 7.8 vs. 18.1 ± 8.4 mm Hg, P = 0.006, peak velocity of 2.5 ± 0.6 vs. 2.9 ± 0.6 m/s, P = 0.003). CONCLUSIONS: TAVR is a safe and reasonable option for patients with small aortic annuli and is associated with shorter hospital stays and more favorable postoperative hemodynamic outcomes compared with SAVR. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Tomada de Decisão Clínica , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Xenoenxertos , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
J Interv Cardiol ; 31(5): 543-552, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30225907

RESUMO

This article is a continuation of our previously published annual reviews of transcatheter aortic valve replacement (TAVR). In 2017, TAVR further established a foothold in the management of intermediate risk patients with the publication of SURTAVI trial. Randomized trials also addressed the use of cerebral protection during TAVR and single versus dual antiplatelet therapy after TAVR. Newer generation valve systems continued to be studied for their efficacy and safety. This paper summarizes the major studies published in 2017.


Assuntos
Estenose da Valva Aórtica , Complicações Pós-Operatórias/prevenção & controle , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Prognóstico , Risco Ajustado , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
13.
Eur Heart J ; 38(38): 2879-2887, 2017 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-29019612

RESUMO

AIMS: Transthyretin cardiac amyloidosis (ATTR-CA) has been reported in patients with aortic stenosis (AS) but its prevalence and phenotype are not known. We examine elderly patients with severe symptomatic AS undergoing transcatheter aortic valve replacement (TAVR) and determine the prevalence and phenotype of ATTR-CA non-invasively. METHODS AND RESULTS: We performed technetium-99m pyrophosphate (99mTc-PYP) cardiac scintigraphy prospectively on patients who underwent TAVR, to screen for ATTR-CA. Transthoracic echocardiography and speckle-strain imaging were performed. We assessed the association of several parameters with ATTR-CA using multivariable logistic regression and constructed receiver operating curves to evaluate the best predictors of ATTR-CA. Among 151 patients (mean age 84 ± 6 years, 68% men), 16% (n = 24) screened positive for ATTR-CA with 99mTc-PYP scintigraphy. Compared with patients without ATTR-CA, ATTR-CA patients had a thicker interventricular septum (1.3 vs. 1.1 cm, P = 0.007), higher left ventricular (LV) mass index (130 vs. 98 g/m2, P = 0.002), and lower stroke volume index (30 vs. 36 mL/m2, P = 0.009). ATTR-CA patients had advanced diastolic dysfunction with higher E/A ratio (2.3 vs. 0.9, P = 0.001) and lower deceleration time (176 vs. 257 ms, P < 0.0001); impairment in systolic function with lower ejection fraction (48% vs. 56%, P = 0.011), myocardial contraction fraction (26 vs. 41, P < 0.0001), and average of lateral and septal mitral annular tissue Doppler S' (4.0 vs. 6.6 cm/s, P < 0.0001). While ATTR-CA patients had more impaired global longitudinal strain (-12 vs. -16%, P = 0.007), relative apical longitudinal strain was the same regardless of ATTR-CA diagnosis (0.98 vs. 0.98, P = 0.991). Average S' best predicted ATTR-CA in multivariable logistic regression (odds ratio 16.67 per 1 cm/s decrease with AUC 0.96, 95% confidence interval 0.90-0.99, P = 0.002) with a value ≤6 conferring 100% sensitivity for predicting a positive 99mTc-PYP amyloid scan. CONCLUSIONS: Transthyretin cardiac amyloidosis is prevalent in 16% of patients with severe calcific AS undergoing TAVR and is associated with a severe AS phenotype of low-flow low-gradient with mildly reduced ejection fraction. Average tissue Doppler mitral annular S' of < 6 cm/s may be a sensitive measure that should prompt a confirmatory 99mTc-PYP scan and subsequent testing for ATTR-CA. Prospective assessment of outcomes after TAVR is needed in patients with and without ATTR-CA.


Assuntos
Neuropatias Amiloides Familiares/complicações , Estenose da Valva Aórtica/complicações , Cardiomiopatias/complicações , Calcificação Vascular/complicações , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Fenótipo , Estudos Prospectivos , Cintilografia , Compostos Radiofarmacêuticos , Volume Sistólico/fisiologia , Pirofosfato de Tecnécio Tc 99m , Substituição da Valva Aórtica Transcateter , Calcificação Vascular/cirurgia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
14.
Curr Cardiol Rep ; 19(12): 128, 2017 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-29075913

RESUMO

PURPOSE OF REVIEW: Transcatheter valvular interventions have increased in importance and utility for surgical valve repair and replacement. Cardiac imaging is the most crucial aspect of procedural planning and guidance. Echocardiography is a widely used, portable, and dynamic imaging modality used for many of these interventions. This review will summarize the role echocardiography in structural heart valvular interventions. RECENT FINDINGS: Intraprocedural echocardiographic guidance has been a mainstay of structural heart interventions. Over the years, the use of 3-dimensional echocardiography has increased, and studies have shown utility in paravalvular leak prediction in the setting of transcatheter aortic valve replacement, procedural guidance in MitraClip repair, and in mitral and tricuspid valve therapies. Intraprocedural echocardiography is of paramount important for procedural success during all structural heart valvular interventions. Continued use of 2 and 3-dimensional echocardiography will be a major factor in driving the innovative field of structural heart interventions forward.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cuidados Intraoperatórios/métodos , Anuloplastia da Valva Mitral/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
16.
JCO Oncol Pract ; : OP2300816, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662969

RESUMO

This review critically analyzes the incidence of trastuzumab-induced left ventricular systolic dysfunction and congestive heart failure (CHF), distinguishing between cases with and without prior anthracycline exposure. It highlights the fact that the elevated risk of trastuzumab-induced cardiotoxicity is closely associated with prior anthracycline exposure. In the absence of prior anthracycline exposure, the incidence rates of trastuzumab-induced cardiotoxicity, particularly CHF (ranging from 0% to 0.5%), are largely comparable with those reported in the general population, especially when reversibility is taken into account. Current cardiac surveillance recommendations during trastuzumab treatment have not yet adapted to the increasing adoption of nonanthracycline treatment strategies and the associated low risk of cardiotoxicity. We propose a refined monitoring protocol to reduce the frequency of cardiac evaluations for low-risk to moderate-risk patients, especially those receiving nonanthracycline treatments. By focusing on patients at high risk or those with prior anthracycline exposure, this strategy seeks to optimize the cost-effectiveness of cardiac care in oncology.

17.
Front Cardiovasc Med ; 11: 1382418, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38903970

RESUMO

Introduction: The evaluation of left ventricular diastolic dysfunction (LVDD) by clinical cardiac magnetic resonance (CMR) remains a challenge. We aimed to train and evaluate a machine-learning (ML) algorithm for the assessment of LVDD by clinical CMR variables and to investigate its prognostic value for predicting hospitalized heart failure and all-cause mortality. Methods: LVDD was characterized by echocardiography following the ASE guidelines. Eight demographic and nineteen common clinical CMR variables including delayed enhancement were used to train Random Forest models with a Bayesian optimizer. The model was evaluated using bootstrap and five-fold cross-validation. Area under the ROC curve (AUC) was utilized to evaluate the model performance. An ML risk score was used to stratify the risk of heart failure hospitalization and all-cause mortality. Results: A total of 606 consecutive patients underwent CMR and echocardiography within 7 days for cardiovascular disease evaluation. LVDD was present in 303 subjects by echocardiography. The performance of the ML algorithm was good using the CMR variables alone with an AUC of 0.868 (95% CI: 0.811-0.917), which was improved by combining with demographic data yielding an AUC 0.895 (95% CI: 0.845-0.939). The algorithm performed well in an independent validation cohort with AUC 0.810 (0.731-0.874). Subjects with higher ML scores (>0.4121) were associated with increased adjusted hazard ratio for a composite outcome than subjects with lower ML scores (1.72, 95% confidence interval 1.09-2.71). Discussion: An ML algorithm using variables derived from clinical CMR is effective in identifying patients with LVDD and providing prognostication for adverse clinical outcomes.

18.
Am J Cardiol ; 218: 102-112, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432332

RESUMO

There are various devices under clinical investigation for transcatheter mitral valve intervention and transcatheter tricuspid valve intervention (TTVI); however, the exclusion rates remain high. We aimed to investigate the exclusion rates for transcatheter mitral valve repair (TMVr), transcatheter mitral valve replacement (TMVR), transcatheter tricuspid valve repair (TTVr), and transcatheter tricuspid valve replacement (TTVR). There were 129 patients who were referred to St. Francis Hospital & Heart Center valve clinic and completed screening between January 2021 and July 2022. The causes for exclusion were classified into 4 categories: patient withdrawal, anatomic unsuitability, clinical criteria, and medical futility. In 129 patients, the exclusion rates for TMVr, TMVR, TTVr, and TTVR were 81%, 85%, 91%, and 87%, respectively. Patient withdrawal and medical futility were leading etiologies for exclusion, followed by anatomic unsuitability. TMVr had the highest rate of patient withdrawal (64%) and the lowest anatomic unsuitability (5%) because of short posterior leaflet length. Replacement interventions have a higher anatomic unsuitability (33%) than repair interventions (17%) (p = 0.04). Most exclusions of anatomic unsuitability were because of mitral stenosis or small annulus size for TMVR and large annulus size for TTVR. A total of 50% of exclusions from TTVr were because of the presence of pacemaker/defibrillator leads. In patients excluded from their respective trials, patients being referred for TMVr had the highest recurrent hospitalization and repair group had a higher mortality (p <0.01 and p = 0.01, respectively). In conclusion, the exclusion rates for transcatheter mitral valve intervention and TTVI trials remain high because of various reasons, limiting patient enrollment and treatment. This supports the need for further device improvement or exploring alternative means of therapy.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Tricúspide/cirurgia , Cateterismo Cardíaco , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia , Hospitais
19.
Int J Cardiovasc Imaging ; 40(6): 1363-1376, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38676848

RESUMO

Contrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using .15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52-0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR.


Assuntos
Meios de Contraste , Interpretação de Imagem Assistida por Computador , Angiografia por Ressonância Magnética , Variações Dependentes do Observador , Compostos Organometálicos , Valor Preditivo dos Testes , Veias Pulmonares , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Meios de Contraste/administração & dosagem , Compostos Organometálicos/administração & dosagem , Idoso , Técnicas de Imagem de Sincronização Cardíaca , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter , Eletrocardiografia
20.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38316377

RESUMO

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Humanos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Idoso de 80 Anos ou mais , Resultado do Tratamento , Ajuste de Prótese
SELEÇÃO DE REFERÊNCIAS