Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(18)2021 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-34577492

RESUMO

The relationship between the robustness of HRV derived by linear and nonlinear methods to the required minimum data lengths has yet to be well understood. The normal electrocardiography (ECG) data of 14 healthy volunteers were applied to 34 HRV measures using various data lengths, and compared with the most prolonged (2000 R peaks or 750 s) by using the Mann-Whitney U test, to determine the 0.05 level of significance. We found that SDNN, RMSSD, pNN50, normalized LF, the ratio of LF and HF, and SD1 of the Poincaré plot could be adequately computed by small data size (60-100 R peaks). In addition, parameters of RQA did not show any significant differences among 60 and 750 s. However, longer data length (1000 R peaks) is recommended to calculate most other measures. The DFA and Lyapunov exponent might require an even longer data length to show robust results. Conclusions: Our work suggests the optimal minimum data sizes for different HRV measures which can potentially improve the efficiency and save the time and effort for both patients and medical care providers.


Assuntos
Eletrocardiografia , Adulto , Voluntários Saudáveis , Frequência Cardíaca , Humanos , Estatísticas não Paramétricas
2.
Methods ; 133: 81-90, 2018 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-29050826

RESUMO

Neural stem cell (NSC) cultures have been considered technically challenging for time-lapse analysis due to high motility, photosensitivity, and growth at confluent densities. We have tested feasibility of long-term live-cell time-lapse analysis for NSC migration and differentiation studies. Here, we describe a method to study the dynamics of cell cycle, migration, and lineage selection in cultured multipotent mouse or human NSCs using single-cell tracking during a long-term, 7-14 day live-cell time-lapse analysis. We used in-house made PDMS inserts with five microwells on a glass coverslip petri-dish to constrain NSC into the area of acquisition during long-term live-cell imaging. In parallel, we have defined image acquisition settings for single-cell tracking of cell cycle dynamics using Fucci-reporter mouse NSC for 7 days as well as lineage selection and migration using human NSC for 14 days. Overall, we show that adjustments of live-cell analysis settings can extend the time period of single-cell tracking in mouse or human NSC from 24-72 h up to 7-14 days and potentially longer. However, we emphasize that experimental use of repeated fluorescence imaging will require careful consideration of controls during acquisition and analysis.


Assuntos
Técnicas de Cultura de Células/métodos , Células-Tronco Neurais/citologia , Análise de Célula Única/métodos , Imagem com Lapso de Tempo/métodos , Linhagem da Célula/fisiologia , Movimento Celular/fisiologia , Rastreamento de Células/métodos , Humanos , Células-Tronco Neurais/fisiologia
3.
Analyst ; 141(13): 4181-8, 2016 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-27163263

RESUMO

Silica (SiO2) micro- and nanostructures fabricated with pre-stressed thermoplastic shrink wrap film have been shown to yield far-field fluorescence signal enhancements over their planar or wrinkled counterparts. The SiO2 structures have previously been used for improved detection of fluorescently labelled proteins and DNA. In this work, we probe the mechanism responsible for the dramatic increases in fluorescence signal intensity. Optical characterization studies attribute the fluorescence signal enhancements to increased surface density and light scattering from the rough SiO2 structures. Using this information, we come up with a theoretical approximation for the enhancement factor based off the scattering effects alone. We show that increased deposition thickness of SiO2 yields improved fluorescence signal enhancements, with an optimal SiO2 thin layer achieved at 20 nm. Finally, we show that the SiO2 substrates serve as a suitable platform for disease diagnostics, and show improved limits of detection (LOD) for the human immunodeficiency virus type 1 (HIV-1) p24 antigen.


Assuntos
Capsídeo/química , Proteína do Núcleo p24 do HIV/análise , HIV-1 , Nanoestruturas , Dióxido de Silício , Limite de Detecção
4.
Langmuir ; 30(37): 10979-83, 2014 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-25191785

RESUMO

We describe a manufacturable and scalable method for fabrication of multiscale wrinkled silica (SiO2) structures on shrink-wrap film to enhance fluorescence signals in DNA fluorescence microarrays. We are able to enhance the fluorescence signal of hybridized DNA by more than 120 fold relative to a planar glass slide. Notably, our substrate has improved detection sensitivity (280 pM) relative to planar glass slide (11 nM). Furthermore, this is accompanied by a 30-45 times improvement in the signal-to-noise ratio (SNR). Unlike metal enhanced fluorescence (MEF) based enhancements, this is a far-field and uniform effect based on surface concentration and photophysical effects from the nano- to microscale SiO2 structures. Notably, the photophysical effects contribute an almost 2.5 fold enhancement over the concentration effects alone. Therefore, this simple and robust method offers an efficient technique to enhance the detection capabilities of fluorescence based DNA microarrays.


Assuntos
Fluorescência , Análise de Sequência com Séries de Oligonucleotídeos , Dióxido de Silício/química , Estrutura Molecular , Tamanho da Partícula , Propriedades de Superfície
5.
Laryngoscope Investig Otolaryngol ; 9(3): e1272, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38803458

RESUMO

Objective: Currently, diagnosis of cerebrospinal fluid (CSF) rhinorrhea relies on a multimodal approach, increasing costs and ultimately delaying diagnosis. In the United States and internationally, the crux of such a diagnosis relies on confirmation testing (via biomarkers) and localization (e.g., imaging). Biomarker testing may require analysis at an outside facility, resulting in delays diagnosis and treatment. In addition, specialized imaging may be nonspecific and often requires an active leak for diagnosis. There remains a clear need for innovative new technology. Methods: A comprehensive review was conducted on both foundational and innovative scholarly articles regarding current and emerging diagnosis modalities for CSF. Results: Current modalities in CSF rhinorrhea diagnosis and localization include laboratory tests (namely, B2T immunofixation), imaging (CT and/or MRI) with or without intrathecal administration, and surgical exploration. Each of these modalities carry flaws, risks, and benefits, ultimately contributing to delays in diagnosis and morbidity. Promising emerging technologies include lateral flow immunoassays (LFI) and biologically functionalized field-effect transistors (BioFET). Nevertheless, these carry some drawbacks of their own, and require further validation. Conclusion: CSF rhinorrhea remains a challenging diagnosis, requiring a multimodal approach to differentiate from nonpathologic causes of rhinorrhea. Current methods in diagnosis are imperfect, as the ideal test would be a readily accessible, inexpensive, rapid, highly accurate point-of-care test without the need for excess fluid or specialized processing. Critical work is being done to develop promising, new, improved tests, though a clear successor has not yet emerged. Level of Evidence: N/A.

6.
Sci Rep ; 13(1): 19245, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37935766

RESUMO

Associations between cerebrovascular disease and impaired autonomic function and cerebrovascular reactivity have led to increased interest in variability of heart rate (HRV) and blood pressure (BPV) following stroke. In this study, beat-to-beat pulse rate variability (PRV) and BPV were measured in clinically stable stroke patients (6 ischemic, 2 hemorrhagic) at least one year after their last cerebrovascular event. Beat-to-beat blood pressure (BP) measurements were collected from subjects while resting in the sitting position for one hour. Compared with healthy controls, stroke patients exhibited significantly greater time-domain (standard deviation, coefficient of variation, average real variability) and normalized high-frequency BPV (all p < 0.05). Stroke patients also exhibited lower LF:HF ratios than control subjects (p = 0.003). No significant differences were observed in PRV between the two groups, suggesting that BPV may be a more sensitive biomarker of cerebrovascular function in long-term post-stroke patients. Given a paucity of existing literature investigating beat-to-beat BPV in clinically stable post-stroke patients long (> 1 year) after their cerebrovascular events, this pilot study can help inform future studies investigating the mechanisms and effects of BPV in stroke. Elucidating this physiology may facilitate long-term patient monitoring and pharmacological management to mitigate the risk for recurrent stroke.


Assuntos
Acidente Vascular Cerebral , Humanos , Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Projetos Piloto , Monitorização Fisiológica
7.
Nat Commun ; 14(1): 7522, 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37980425

RESUMO

The human body exhibits complex, spatially distributed chemo-electro-mechanical processes that must be properly captured for emerging applications in virtual/augmented reality, precision health, activity monitoring, bionics, and more. A key factor in enabling such applications involves the seamless integration of multipurpose wearable sensors across the human body in different environments, spanning from indoor settings to outdoor landscapes. Here, we report a versatile epidermal body area network ecosystem that enables wireless power and data transmission to and from battery-free wearable sensors with continuous functionality from dry to underwater settings. This is achieved through an artificial near field propagation across the chain of biocompatible, magneto-inductive metamaterials in the form of stretchable waterborne skin patches-these are fully compatible with pre-existing consumer electronics. Our approach offers uninterrupted, self-powered communication for human status monitoring in harsh environments where traditional wireless solutions (such as Bluetooth, Wi-Fi or cellular) are unable to communicate reliably.


Assuntos
Ecossistema , Realidade Virtual , Humanos , Tecnologia sem Fio , Epiderme , Monitorização Fisiológica
8.
Sci Rep ; 12(1): 16772, 2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36202815

RESUMO

Accurate continuous non-invasive blood pressure (CNIBP) monitoring is the holy grail of digital medicine but remains elusive largely due to significant drifts in signal and motion artifacts that necessitate frequent device recalibration. To address these challenges, we developed a unique approach by creating a novel intra-beat biomarker (Diastolic Transit Time, DTT) to achieve highly accurate blood pressure (BP) estimations. We demonstrated our approach's superior performance, compared to other common signal processing techniques, in eliminating stochastic baseline wander, while maintaining signal integrity and measurement accuracy, even during significant hemodynamic changes. We applied this new algorithm to BP data collected using non-invasive sensors from a diverse cohort of high acuity patients and demonstrated that we could achieve close agreement with the gold standard invasive arterial line BP measurements, for up to 20 min without recalibration. We established our approach's generalizability by successfully applying it to pulse waveforms obtained from various sensors, including photoplethysmography and capacitive-based pressure sensors. Our algorithm also maintained signal integrity, enabling reliable assessments of BP variability. Moreover, our algorithm demonstrated tolerance to both low- and high-frequency motion artifacts during abrupt hand movements and prolonged periods of walking. Thus, our approach shows promise in constituting a necessary advance and can be applied to a wide range of wearable sensors for CNIBP monitoring in the ambulatory and inpatient settings.


Assuntos
Determinação da Pressão Arterial , Fotopletismografia , Biomarcadores , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Frequência Cardíaca/fisiologia , Humanos , Fotopletismografia/métodos
9.
Sci Rep ; 12(1): 14873, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050339

RESUMO

A rising number of authors are drawing evidence on the diagnostic capacity of specific volatile organic compounds (VOCs) resulting from some body fluids. While cancer incidence in society is on the rise, it becomes clear that the analysis of these VOCs can yield new strategies to mitigate advanced cancer incidence rates. This paper presents the methodology implemented to test whether a device consisting of an electronic nose inspired by a dog's olfactory system and olfactory neurons is significantly informative to detect breast cancer (BC). To test this device, 90 human urine samples were collected from control subjects and BC patients at a hospital. To test this system, an artificial intelligence-based classification algorithm was developed. The algorithm was firstly trained and tested with data resulting from gas chromatography-mass spectrometry (GC-MS) urine readings, leading to a classification rate of 92.31%, sensitivity of 100.00%, and specificity of 85.71% (N = 90). Secondly, the same algorithm was trained and tested with data obtained with our eNose prototype hardware, and class prediction was achieved with a classification rate of 75%, sensitivity of 100%, and specificity of 50%.


Assuntos
Neoplasias da Mama , Compostos Orgânicos Voláteis , Animais , Inteligência Artificial , Neoplasias da Mama/diagnóstico , Cães , Nariz Eletrônico , Feminino , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Compostos Orgânicos Voláteis/análise
10.
Materials (Basel) ; 14(2)2021 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-33450998

RESUMO

Practical wearable applications of soft strain sensors require sensors capable of not only detecting subtle physiological signals, but also of withstanding large scale deformation from body movement. Encapsulation is one technique to protect sensors from both environmental and mechanical stressors. We introduced an encapsulation layer to crack-based wrinkled metallic thin film soft strain sensors as an avenue to improve sensor stretchability, linear response, and robustness. We demonstrate that encapsulated sensors have increased mechanical robustness and stability, displaying a significantly larger linear dynamic range (~50%) and increased stretchability (260% elongation). Furthermore, we discovered that these sensors have post-fracture signal recovery. They maintained conductivity to the 50% strain with stable signal and demonstrated increased sensitivity. We studied the crack formation behind this phenomenon and found encapsulation to lead to higher crack density as the source for greater stretchability. As crack formation plays an important role in subsequent electrical resistance, understanding the crack evolution in our sensors will help us better address the trade-off between high stretchability and high sensitivity.

11.
Front Digit Health ; 3: 696606, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34713172

RESUMO

We test a new wireless soft capacitance sensor (CAP) based on applanation tonometry at the radial and dorsalis pedis arteries against the gold standard, invasive arterial line (A-Line), for continuous beat to beat blood pressure (BP) measurements in the Operating Room during surgical procedures under anesthesia in 17 subjects with the mean age and body mass index (BMI) of 57. 35 ± 18.72 years and 27.36 ± 4.20 kg/m2, respectively. We have identified several parameters to monitor in order to compare how well the CAP sensor tracks the entire hemodynamic waveform as compared to the A-Line. This includes waveform similarity, heart rate (HR), absolute systolic BP (SBP), diastolic BP (DBP), and temporal response to a vasopressor. Overall, the CAP sensor shows good correlations with A-Line with respect to hemodynamic shape (r > 0.89), HR (mean bias = 0.0006; SD = 0.17), absolute SBP, and DBP in a line of best fit (slope = 0.98 in SBP; 1.08 in DBP) and the mean bias derived from Bland-Altman method to be 1.92 (SD = 12.55) in SBP and 2.38 (SD = 12.19) in DBP across body habitus and age in OR patients under general anesthesia. While we do observe drifts in the system, we still obtain decent correlations with respect to the A-Line as evidenced by excellent linear fit and low mean bias across patients. When we post-process using a different calibration method to account for the drift, the mean bias and SD improve dramatically to -1.85 and 7.19 DBP as well as 1.43 and 7.43 SBP, respectively, indicating a promising potential for improvement when we integrate strategies to account for movement identified by our integrated accelerometer data.

12.
Lab Chip ; 21(1): 83-92, 2021 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-33300516

RESUMO

Microfluidic devices are traditionally monitored by bulky and expensive off-chip sensors. We have developed a soft piezoresistive sensor capable of measuring micron-level strains that can be easily integrated into devices via soft lithography. We apply this sensor to achieve fast and localized monitoring of pressure, flow, and valve actuation.


Assuntos
Dispositivos Lab-On-A-Chip , Microfluídica
13.
Anal Methods ; 13(7): 874-883, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33576354

RESUMO

Using the children's toy, Shrinky-Dink©, we present an aptamer-based electrochemical (E-AB) assay that recognizes the spike protein of SARS-CoV-2 in saliva for viral infection detection. The low-cost electrodes are implementable at population scale and demonstrate detection down to 1 ag mL-1 of the S1 subunit of the spike protein.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Poliestirenos/química , SARS-CoV-2/química , Saliva/química , Glicoproteína da Espícula de Coronavírus/análise , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/instrumentação , Eletrodos , Ouro/química , Humanos , Limite de Detecção , Domínios Proteicos , Glicoproteína da Espícula de Coronavírus/química
14.
Lab Chip ; 10(18): 2472-5, 2010 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-20680207

RESUMO

This paper presents a rapid, ultra-low-cost approach to fabricate microfluidic devices using a polyolefin shrink film and a digital craft cutter. The shrinking process (with a 95% reduction in area) results in relatively uniform and consistent microfluidic channels with smooth surfaces, vertical sidewalls, and high aspect ratio channels with lateral resolutions well beyond the tool used to cut them. The thermal bonding of the layers results in strongly bonded devices. Complex microfluidic designs are easily designed on the fly and protein assays are also readily integrated into the device. Full device characterization including channel consistency, optical properties, and bonding strength are assessed in this technical note.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Microtecnologia/métodos , Plásticos/química , Animais , Imunoensaio , Dispositivos Ópticos , Sistemas Automatizados de Assistência Junto ao Leito , Polienos/química , Propriedades de Superfície
15.
Lab Chip ; 10(12): 1623-6, 2010 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-20517559

RESUMO

Polyolefins are finding increased popularity in microfluidic applications due to their attractive mechanical, processing, and optical properties. While intricate features are typically realized in these thermoplastics by hot embossing and injection molding, such fabrication approaches are expensive and slow. Here, we apply our shrink-induced approach-first demonstrated with polystyrene 'Shrinky-Dink' sheets-to create micro- and nanostructures with cross-linked polyolefin thin films. These multi-layered films shrink by 95% and with greater uniformity than the Shrinky-Dinks. With such significant reduction in size, along with attractive material properties, such commodity films could find important applications in low cost microfluidic prototyping as well as in point-of-care diagnostics. In this technical note, we demonstrate the ability to rapidly and easily create unique microstructures, increase microarray feature density, and even induce self-assembled integrated metallic nanostructures with these shrink wrap films.


Assuntos
Polienos/química , Metais/química , Técnicas Analíticas Microfluídicas , Poliestirenos/química , Impressão , Análise Serial de Proteínas , Temperatura
16.
J Opt Soc Am A Opt Image Sci Vis ; 27(5): 1002-11, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20448766

RESUMO

We present a theory for the multiple scattering of light by obstacles situated over a rough surface. This problem is important for applications in biological and chemical sensors. To keep the formulation of this theory simple, we study scalar waves. This theory requires knowledge of the scattering operator (t-matrix) for each of the obstacles as well as the reflection operator for the rough surface. The scattering operator gives the field scattered by the obstacle due to an exciting field incident on the scatterer. The reflection operator gives the field reflected by the rough surface due to an exciting field incident on the rough surface. We apply this general theory for the special case of point scatterers and a slightly rough surface with homogeneous Dirichlet and Neumann boundary conditions. We show examples that demonstrate the utility of this theory.


Assuntos
Luz , Espalhamento de Radiação , Propriedades de Superfície
17.
Polymers (Basel) ; 12(7)2020 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-32610500

RESUMO

Soft stretchable sensors rely on polymers that not only withstand large deformations while retaining functionality but also allow for ease of application to couple with the body to capture subtle physiological signals. They have been applied towards motion detection and healthcare monitoring and can be integrated into multifunctional sensing platforms for enhanced human machine interface. Most advances in sensor development, however, have been aimed towards active materials where nearly all approaches rely on a silicone-based substrate for mechanical stability and stretchability. While silicone use has been advantageous in academic settings, conventional silicones cannot offer self-healing capability and can suffer from manufacturing limitations. This review aims to cover recent advances made in polymer materials for soft stretchable conductors. New developments in substrate materials that are compliant and stretchable but also contain self-healing properties and self-adhesive capabilities are desirable for the mechanical improvement of stretchable electronics. We focus on materials for stretchable conductors and explore how mechanical deformation impacts their performance, summarizing active and substrate materials, sensor performance criteria, and applications.

18.
RSC Adv ; 11(2): 671-677, 2020 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35423693

RESUMO

Electrochemical aptamer-based (E-AB) sensors provide a great opportunity towards the goal of point-of-care and wearable sensing technologies due to their good sensitivity and selectivity. Nevertheless, the output signals from this sensor class remain low when sensors are interrogated via square-wave voltammetry. This low signaling limits the sensor's precision for its capability to detect small changes in target concentrations. To circumvent this, we proposed here the use of a readily shrink-induced, wrinkled Au-coating polyolefin film to immobilize a greater number of DNA probes and thus improve the signaling. Specifically, wrinkled gold film exhibits a 5.5-fold increase of surface area in comparison to the unwrinkled ones. Using these substrates we fabricated a set of E-AB sensors of three biological molecules, including kanamycin, doxorubicin and ATP. We achieved up to 10-fold increase in its current and also good accuracies within ±20% error in the target concentration range across 2 orders of magnitude.

19.
medRxiv ; 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-33236028

RESUMO

Using the children's toy, Shrinky-Dink ©, we present an aptamer-based electrochemical (E-AB) assay that recognizes the spike protein of SARS-CoV-2 in saliva for viral infection detection. The low-cost electrodes are implementable at population scale and demonstrate detection down to 0.1 fg mL -1 of the S1 subunit of the spike protein.

20.
Front Physiol ; 11: 165, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32226389

RESUMO

Although biomimetic stimuli, such as microgroove-induced alignment (µ), triiodothyronine (T3) induction, and electrical conditioning (EC), have been reported to promote maturation of human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs), a systematic examination of their combinatorial effects on engineered cardiac tissue constructs and the underlying molecular pathways has not been reported. Herein, human embryonic stem cell-derived ventricular cardiomyocytes (hESC-VCMs) were used to generate a micro-patterned human ventricular cardiac anisotropic sheets (hvCAS) for studying the physiological effects of combinatorial treatments by a range of functional, calcium (Ca2+)-handling, and molecular analyses. High-resolution optical mapping showed that combined µ-T3-EC treatment of hvCAS increased the conduction velocity, anisotropic ratio, and proportion of mature quiescent-yet-excitable preparations by 2. 3-, 1. 8-, and 5-fold (>70%), respectively. Such electrophysiological changes could be attributed to an increase in inward sodium current density and a decrease in funny current densities, which is consistent with the observed up- and downregulated SCN1B and HCN2/4 transcripts, respectively. Furthermore, Ca2+-handling transcripts encoding for phospholamban (PLN) and sarco/endoplasmic reticulum Ca2+-ATPase (SERCA) were upregulated, and this led to faster upstroke and decay kinetics of Ca2+-transients. RNA-sequencing and pathway mapping of T3-EC-treated hvCAS revealed that the TGF-ß signaling was downregulated; the TGF-ß receptor agonist and antagonist TGF-ß1 and SB431542 partially reversed T3-EC induced quiescence and reduced spontaneous contractions, respectively. Taken together, we concluded that topographical cues alone primed cardiac tissue constructs for augmented electrophysiological and calcium handling by T3-EC. Not only do these studies improve our understanding of hPSC-CM biology, but the orchestration of these pro-maturational factors also improves the use of engineered cardiac tissues for in vitro drug screening and disease modeling.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA