Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 199
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Breast Cancer Res ; 23(1): 88, 2021 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-34425871

RESUMO

PURPOSE: This study evaluated the ability of 18F-Fluorodeoxyglucose (FDG) and 18F-Fluorothymidine (FLT) imaging with positron emission tomography (PET) to measure early response to endocrine therapy from baseline to just prior to surgical resection in estrogen receptor positive (ER+) breast tumors. METHODS: In two separate studies, women with early stage ER+ breast cancer underwent either paired FDG-PET (n = 22) or FLT-PET (n = 27) scans prior to endocrine therapy and again in the pre-operative setting. Tissue samples for Ki-67 were taken for all patients both prior to treatment and at the time of surgery. RESULTS: FDG maximum standardized uptake value (SUVmax) declined in 19 of 22 lesions (mean 17% (range -45 to 28%)). FLT SUVmax declined in 24 of 27 lesions (mean 26% (range -77 to 7%)). The Ki-67 index declined in both studies, from pre-therapy (mean 23% (range 1 to 73%)) to surgery [mean 8% (range < 1 to 41%)]. Pre- and post-therapy PET measures showed strong rank-order agreement with Ki-67 percentages for both tracers; however, the percent change in FDG or FLT SUVmax did not demonstrate a strong correlation with Ki-67 index change or Ki-67 at time of surgery. CONCLUSIONS: A window-of-opportunity approach using PET imaging to assess early response of breast cancer therapy is feasible. FDG and FLT-PET imaging following a short course of neoadjuvant endocrine therapy demonstrated measurable changes in SUVmax in early stage ER+ positive breast cancers. The percentage change in FDG and FLT-PET uptake did not correlate with changes in Ki-67; post-therapy SUVmax for both tracers was significantly associated with post-therapy Ki-67, an established predictor of endocrine therapy response.


Assuntos
Inibidores da Aromatase/uso terapêutico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Didesoxinucleosídeos/uso terapêutico , Fluordesoxiglucose F18/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/metabolismo , Neoplasias da Mama/cirurgia , Feminino , Humanos , Antígeno Ki-67/metabolismo , Mastectomia , Pessoa de Meia-Idade , Terapia Neoadjuvante , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/uso terapêutico , Receptores de Estrogênio/metabolismo , Resultado do Tratamento
2.
Radiology ; 294(3): 647-657, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31909700

RESUMO

The Quantitative Imaging Biomarkers Alliance (QIBA) Profile for fluorodeoxyglucose (FDG) PET/CT imaging was created by QIBA to both characterize and reduce the variability of standardized uptake values (SUVs). The Profile provides two complementary claims on the precision of SUV measurements. First, tumor glycolytic activity as reflected by the maximum SUV (SUVmax) is measurable from FDG PET/CT with a within-subject coefficient of variation of 10%-12%. Second, a measured increase in SUVmax of 39% or more, or a decrease of 28% or more, indicates that a true change has occurred with 95% confidence. Two applicable use cases are clinical trials and following individual patients in clinical practice. Other components of the Profile address the protocols and conformance standards considered necessary to achieve the performance claim. The Profile is intended for use by a broad audience; applications can range from discovery science through clinical trials to clinical practice. The goal of this report is to provide a rationale and overview of the FDG PET/CT Profile claims as well as its context, and to outline future needs and potential developments.


Assuntos
Fluordesoxiglucose F18/uso terapêutico , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Biomarcadores Tumorais/análise , Humanos , Interpretação de Imagem Assistida por Computador , Estadiamento de Neoplasias , Neoplasias/patologia , Neoplasias/terapia , Resultado do Tratamento
3.
J Med Virol ; 92(10): 2205-2208, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32470156

RESUMO

Acute respiratory distress syndrome and coagulopathy played an important role in morbidity and mortality of severe COVID-19 patients. A higher frequency of pulmonary embolism (PE) than expected in COVID-19 patients was recently reported. The presenting symptoms for PE were untypical including dyspnea, which is one of the major symptoms in severe COVID-19, especially in those patients with acute respiratory distress syndrome (ARDS). We reported two COVID-19 cases with coexisting complications of PE and ARDS, aiming to consolidate the emerging knowledge of this global health emergency and raise the awareness that the hypoxemia or severe dyspnea in COVID-19 may be related to PE and not necessarily always due to the parenchymal disease.


Assuntos
COVID-19/complicações , Embolia Pulmonar/complicações , Síndrome do Desconforto Respiratório/complicações , SARS-CoV-2/patogenicidade , Doença Aguda , Idoso , Biomarcadores/sangue , Plaquetas/efeitos dos fármacos , Plaquetas/patologia , Plaquetas/virologia , COVID-19/diagnóstico por imagem , COVID-19/virologia , Ceftazidima/uso terapêutico , Dispneia/fisiopatologia , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Heparina/uso terapêutico , Humanos , Hipóxia/fisiopatologia , Pulmão/irrigação sanguínea , Pulmão/efeitos dos fármacos , Pulmão/patologia , Pulmão/virologia , Masculino , Metilprednisolona/uso terapêutico , Pessoa de Meia-Idade , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/tratamento farmacológico , Embolia Pulmonar/virologia , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/tratamento farmacológico , Síndrome do Desconforto Respiratório/virologia , Ribavirina/uso terapêutico , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Tratamento Farmacológico da COVID-19
4.
Am J Respir Crit Care Med ; 199(10): 1257-1266, 2019 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-30422669

RESUMO

Rationale: Screening for non-small cell lung cancer is associated with earlier diagnosis and reduced mortality but also increased harm caused by invasive follow-up of benign pulmonary nodules. Lung tumorigenesis activates the immune system, components of which could serve as tumor-specific biomarkers. Objectives: To profile tumor-derived autoantibodies as peripheral biomarkers of malignant pulmonary nodules. Methods: High-density protein arrays were used to define the specificity of autoantibodies isolated from B cells of 10 resected lung tumors. These tumor-derived autoantibodies were also examined as free or complexed to antigen in the plasma of the same 10 patients and matched benign nodule control subjects. Promising autoantibodies were further analyzed in an independent cohort of 250 nodule-positive patients. Measurements and Main Results: Thirteen tumor B-cell-derived autoantibodies isolated ex vivo showed greater than or equal to 50% sensitivity and greater than or equal to 70% specificity for lung cancer. In plasma, 11 of 13 autoantibodies were present both complexed to and free from antigen. In the larger validation cohort, 5 of 13 tumor-derived autoantibodies remained significantly elevated in cancers. A combination of four of these autoantibodies could detect malignant nodules with an area under the curve of 0.74 and had an area under the curve of 0.78 in a subcohort of indeterminate (8-20 mm in the longest diameter) pulmonary nodules. Conclusions: Our novel pipeline identifies tumor-derived autoantibodies that could effectively serve as blood biomarkers for malignant pulmonary nodule diagnosis. This approach has future implications for both a cost-effective and noninvasive approach to determine nodule malignancy for widespread low-dose computed tomography screening.


Assuntos
Autoanticorpos/imunologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/imunologia , Detecção Precoce de Câncer/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/imunologia , Nódulos Pulmonares Múltiplos/imunologia , Idoso , Biomarcadores Tumorais/imunologia , Carcinoma Pulmonar de Células não Pequenas/fisiopatologia , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Pulmonares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
5.
Eur Radiol ; 29(11): 6100-6108, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31115618

RESUMO

PURPOSE: To compare the ability of radiological semantic and quantitative texture features in lung cancer diagnosis of pulmonary nodules. MATERIALS AND METHODS: A total of N = 121 subjects with confirmed non-small-cell lung cancer were matched with 117 controls based on age and gender. Radiological semantic and quantitative texture features were extracted from CT images with or without contrast enhancement. Three different models were compared using LASSO logistic regression: "CS" using clinical and semantic variables, "T" using texture features, and "CST" using clinical, semantic, and texture variables. For each model, we performed 100 trials of fivefold cross-validation and the average receiver operating curve was accessed. The AUC of the cross-validation study (AUCCV) was calculated together with its 95% confidence interval. RESULTS: The AUCCV (and 95% confidence interval) for models T, CS, and CST was 0.85 (0.71-0.96), 0.88 (0.77-0.96), and 0.88 (0.77-0.97), respectively. After separating the data into two groups with or without contrast enhancement, the AUC (without cross-validation) of the model T was 0.86 both for images with and without contrast enhancement, suggesting that contrast enhancement did not impact the utility of texture analysis. CONCLUSIONS: The models with semantic and texture features provided cross-validated AUCs of 0.85-0.88 for classification of benign versus cancerous nodules, showing potential in aiding the management of patients. KEY POINTS: • Pretest probability of cancer can aid and direct the physician in the diagnosis and management of pulmonary nodules in a cost-effective way. • Semantic features (qualitative features reported by radiologists to characterize lung lesions) and radiomic (e.g., texture) features can be extracted from CT images. • Input of these variables into a model can generate a pretest likelihood of cancer to aid clinical decision and management of pulmonary nodules.


Assuntos
Algoritmos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Neoplasias Pulmonares/diagnóstico , Pulmão/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico , Semântica , Tomografia Computadorizada por Raios X/métodos , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
6.
J Magn Reson Imaging ; 47(5): 1388-1396, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29044908

RESUMO

BACKGROUND: Robust approaches to quantify tumor heterogeneity are needed to provide early decision support for precise individualized therapy. PURPOSE: To conduct a technical exploration of longitudinal changes in tumor heterogeneity patterns on dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI), diffusion-weighted imaging (DWI) and FDG positron emission tomography / computed tomography (PET/CT), and their association to radiation therapy (RT) response in cervical cancer. STUDY TYPE: Prospective observational study with longitudinal MRI and PET/CT pre-RT, early-RT (2 weeks), and mid-RT (5 weeks). POPULATION: Twenty-one FIGO IB2 -IVA cervical cancer patients receiving definitive external beam RT and brachytherapy. FIELD STRENGTH/SEQUENCE: 1.5T, precontrast axial T1 -weighted, axial and sagittal T2 -weighted, sagittal DWI (multi-b values), sagittal DCE MRI (<10 sec temporal resolution), postcontrast axial T1 -weighted. ASSESSMENT: Response assessment 1 month after completion of treatment by a board-certified radiation oncologist from manually delineated tumor volume changes. STATISTICAL TESTS: Intensity histogram (IH) quantiles (DCE SI10% and DWI ADC10% , FDG-PET SUVmax ) and distribution moments (mean, variance, skewness, kurtosis) were extracted. Differences in IH features between timepoints and modalities were evaluated by Skillings-Mack tests with Holm's correction. Area under receiver-operating characteristic curve (AUC) and Mann-Whitney testing was performed to discriminate treatment response using IH features. RESULTS: Tumor IH means and quantiles varied significantly during RT (SUVmean : ↓28-47%, SUVmax : ↓30-59%, SImean : ↑8-30%, SI10% : ↑8-19%, ADCmean : ↑16%, P < 0.02 for each). Among IH heterogeneity features, FDG-PET SUVCoV (↓16-30%, P = 0.011) and DW-MRI ADCskewness decreased (P = 0.001). FDG-PET SUVCoV was higher than DCE-MRI SICoV and DW-MRI ADCCoV at baseline (P < 0.001) and 2 weeks (P = 0.010). FDG-PET SUVkurtosis was lower than DCE-MRI SIkurtosis and DW-MRI ADCkurtosis at baseline (P = 0.001). Some IH features appeared to associate with favorable tumor response, including large early RT changes in DW-MRI ADCskewness (AUC = 0.86). DATA CONCLUSION: Preliminary findings show tumor heterogeneity was variable between patients, modalities, and timepoints. Radiomic assessment of changing tumor heterogeneity has the potential to personalize treatment and power outcome prediction. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1388-1396.


Assuntos
Braquiterapia/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos , Resultado do Tratamento , Carga Tumoral
7.
Strahlenther Onkol ; 193(5): 410-418, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28255667

RESUMO

PURPOSE: To design and apply a framework for predicting symptomatic radiation pneumonitis in patients undergoing thoracic radiation, using both pretreatment anatomic and perfused lung dose-volume parameters. MATERIALS AND METHODS: Radiation treatment planning CT scans were coregistered with pretreatment [99mTc]MAA perfusion SPECT/CT scans of 20 patients who underwent definitive thoracic radiation. Clinical radiation pneumonitis was defined as grade ≥ 2 (CTCAE v4 grading system). Anatomic lung dose-volume parameters were collected from the treatment planning scans. Perfusion dose-volume parameters were calculated from pretreatment SPECT/CT scans. Equivalent doses in 2 Gy per fraction were calculated in the lung to account for differences in treatment regimens and spatial variations in lung dose (EQD2lung). RESULTS: Anatomic lung dosimetric parameters (MLD) and functional lung dosimetric parameters (pMLD70%) were identified as candidate predictors of grade ≥ 2 radiation pneumonitis (AUC > 0.93, p < 0.01). Pairing of an anatomic and functional dosimetric parameter (e. g., MLD and pMLD70%) may further improve prediction accuracy. Not all individuals with high anatomic lung dose (MLD > 13.6 GyEQD2lung, 19.3 Gy for patients receiving 60 Gy in 30 fractions) developed radiation pneumonitis, but all individuals who also had high mean dose to perfused lung (pMLD70% > 13.3 GyEQD2) developed radiation pneumonitis. CONCLUSIONS: The preliminary application of this framework revealed differences between anatomic and perfused lung dosimetry in this limited patient cohort. The addition of perfused lung parameters may help risk stratify patients for radiation pneumonitis, especially in treatment plans with high anatomic mean lung dose. Further investigations are warranted.


Assuntos
Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/radioterapia , Pneumonite por Radiação/diagnóstico , Pneumonite por Radiação/etiologia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonite por Radiação/prevenção & controle , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Resultado do Tratamento
8.
Eur J Nucl Med Mol Imaging ; 44(1): 151-165, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27271051

RESUMO

After seminal papers over the period 2009 - 2011, the use of texture analysis of PET/CT images for quantification of intratumour uptake heterogeneity has received increasing attention in the last 4 years. Results are difficult to compare due to the heterogeneity of studies and lack of standardization. There are also numerous challenges to address. In this review we provide critical insights into the recent development of texture analysis for quantifying the heterogeneity in PET/CT images, identify issues and challenges, and offer recommendations for the use of texture analysis in clinical research. Numerous potentially confounding issues have been identified, related to the complex workflow for the calculation of textural features, and the dependency of features on various factors such as acquisition, image reconstruction, preprocessing, functional volume segmentation, and methods of establishing and quantifying correspondences with genomic and clinical metrics of interest. A lack of understanding of what the features may represent in terms of the underlying pathophysiological processes and the variability of technical implementation practices makes comparing results in the literature challenging, if not impossible. Since progress as a field requires pooling results, there is an urgent need for standardization and recommendations/guidelines to enable the field to move forward. We provide a list of correct formulae for usual features and recommendations regarding implementation. Studies on larger cohorts with robust statistical analysis and machine learning approaches are promising directions to evaluate the potential of this approach.


Assuntos
Previsões , Aumento da Imagem/métodos , Imageamento Tridimensional/tendências , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/tendências , Animais , Medicina Baseada em Evidências , Humanos
9.
IEEE Trans Nucl Sci ; 64(3): 959-968, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30337765

RESUMO

Extremely low-dose CT acquisitions used for PET attenuation correction have high levels of noise and potential bias artifacts due to photon starvation. This work explores the use of a priori knowledge for iterative image reconstruction of the CT-based attenuation map. We investigate a maximum a posteriori framework with cluster-based multinomial penalty for direct iterative coordinate decent (dICD) reconstruction of the PET attenuation map. The objective function for direct iterative attenuation map reconstruction used a Poisson log-likelihood data fit term and evaluated two image penalty terms of spatial and mixture distributions. The spatial regularization is based on a quadratic penalty. For the mixture penalty, we assumed that the attenuation map may consist of four material clusters: air+background, lung, soft tissue, and bone. Using simulated noisy sinogram data, dICD reconstruction was performed with different strengths of the spatial and mixture penalties. The combined spatial and mixture penalties reduced the RMSE by roughly 2 times compared to a weighted least square and filtered backprojection reconstruction of CT images. The combined spatial and mixture penalties resulted in only slightly lower RMSE compared to a spatial quadratic penalty alone. For direct PET attenuation map reconstruction from ultra-low dose CT acquisitions, the combination of spatial and mixture penalties offers regularization of both variance and bias and is a potential method to reconstruct attenuation maps with negligible patient dose. The presented results, using a best-case histogram suggest that the mixture penalty does not offer a substantive benefit over conventional quadratic regularization and diminishes enthusiasm for exploring future application of the mixture penalty.

10.
Radiology ; 278(2): 563-77, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26579733

RESUMO

In the past decade, the field of medical image analysis has grown exponentially, with an increased number of pattern recognition tools and an increase in data set sizes. These advances have facilitated the development of processes for high-throughput extraction of quantitative features that result in the conversion of images into mineable data and the subsequent analysis of these data for decision support; this practice is termed radiomics. This is in contrast to the traditional practice of treating medical images as pictures intended solely for visual interpretation. Radiomic data contain first-, second-, and higher-order statistics. These data are combined with other patient data and are mined with sophisticated bioinformatics tools to develop models that may potentially improve diagnostic, prognostic, and predictive accuracy. Because radiomics analyses are intended to be conducted with standard of care images, it is conceivable that conversion of digital images to mineable data will eventually become routine practice. This report describes the process of radiomics, its challenges, and its potential power to facilitate better clinical decision making, particularly in the care of patients with cancer.


Assuntos
Diagnóstico por Computador/métodos , Diagnóstico por Imagem , Interpretação de Imagem Assistida por Computador/métodos , Informática Médica , Neoplasias/diagnóstico , Algoritmos , Biópsia , Mineração de Dados , Tomada de Decisões , Genômica , Humanos , Neoplasias/patologia , Prognóstico , Sistemas de Informação em Radiologia
11.
Annu Rev Biomed Eng ; 17: 385-414, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26643024

RESUMO

Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Animais , Engenharia Biomédica , Fenômenos Biofísicos , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/tendências , Espalhamento de Radiação , Tomografia Computadorizada por Raios X
12.
Q J Nucl Med Mol Imaging ; 60(1): 25-39, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26576737

RESUMO

Both SPECT, and in particular PET, are unique in medical imaging for their high sensitivity and direct link to a physical quantity, i.e. radiotracer concentration. This gives PET and SPECT imaging unique capabilities for accurately monitoring disease activity for the purposes of clinical management or therapy development. However, to achieve a direct quantitative connection between the underlying radiotracer concentration and the reconstructed image values several confounding physical effects have to be estimated, notably photon attenuation and scatter. With the advent of dual-modality SPECT/CT, PET/CT, and PET/MR scanners, the complementary CT or MR image data can enable these corrections, although there are unique challenges for each combination. This review covers the basic physics underlying photon attenuation and scatter and summarizes technical considerations for multimodal imaging with regard to PET and SPECT quantification and methods to address the challenges for each multimodal combination.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Humanos , Processamento de Imagem Assistida por Computador , Movimento
13.
J Appl Clin Med Phys ; 17(1): 440­456, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894356

RESUMO

Drawing regions of interest (ROIs) in positron emission tomography/computed tomography (PET/CT) scans of the National Electrical Manufacturers Association (NEMA) NU-2 Image Quality (IQ) phantom is a time-consuming process that allows for interuser variability in the measurements. In order to reduce operator effort and allow batch processing of IQ phantom images, we propose a fast, robust, automated algorithm for performing IQ phantom sphere localization and analysis. The algorithm is easily altered to accommodate different configurations of the IQ phantom. The proposed algorithm uses information from both the PET and CT image volumes in order to overcome the challenges of detecting the smallest spheres in the PET volume. This algorithm has been released as an open-source plug-in to the Osirix medical image viewing software package. We test the algorithm under various noise conditions, positions within the scanner, air bubbles in the phantom spheres, and scanner misalignment conditions. The proposed algorithm shows run-times between 3 and 4 min and has proven to be robust under all tested conditions, with expected sphere localization deviations of less than 0.2 mm and variations of PET ROI mean and maximum values on the order of 0.5% and 2%, respectively, over multiple PET acquisitions. We conclude that the proposed algorithm is stable when challenged with a variety of physical and imaging anomalies, and that the algorithm can be a valuable tool for those who use the NEMA NU-2 IQ phantom for PET/CT scanner acceptance testing and QA/QC.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Imagem Multimodal/métodos , Imagens de Fantasmas , Água/química , Humanos , Reconhecimento Automatizado de Padrão , Tomografia por Emissão de Pósitrons/métodos , Controle de Qualidade , Tomografia Computadorizada por Raios X/métodos
14.
Radiology ; 277(2): 538-45, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25989387

RESUMO

PURPOSE: To determine the extent of variations in computing standardized uptake value (SUV) by body weight (SUV(BW)) among different software packages and to propose a Digital Imaging and Communications in Medicine (DICOM) reference test object to ensure the standardization of SUV computation between medical image viewing workstations. MATERIALS AND METHODS: Research ethics board approval was not necessary because this study only evaluated images of a phantom. A synthetic set of positron emission tomographic (PET)/computed tomographic (CT) image data, called a digital reference object (DRO), with known SUV was created. The DRO was sent to 16 sites and evaluated on 21 different PET/CT display software packages. Users were asked to draw various regions of interest (ROIs) on specific features and report the maximum, minimum, mean, and standard deviation of the SUVs for each ROI. Numerical tolerances were defined for each metric, and the fraction of reported values within the tolerance was recorded, as was the mean, standard deviation, and range of the metrics. RESULTS: The errors in reported maximum SUV ranged from -37.8% to 0% for an isolated voxel with 4.11:1 target-to-background activity level, and errors in the reported mean SUV ranged from -1.6% to 100% for a region with controlled noise. There was also a range of errors in the less commonly used metrics of minimum SUV and standard deviation SUV. CONCLUSION: The variability of computed SUV(BW) between different software packages is substantial enough to warrant the introduction of a reference standard for medical image viewing workstations.


Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/normas , Radioisótopos/farmacocinética , Simulação por Computador , Humanos , Aumento da Imagem/normas , Interpretação de Imagem Assistida por Computador/normas , Imagens de Fantasmas , Valores de Referência , Software
15.
J Appl Clin Med Phys ; 16(5): 3-13, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699325

RESUMO

The American Association of Physicists in Medicine (AAPM) and the Society of Nuclear Medicine and Molecular Imaging (SNMMI) recognized the need for a review of the current state of nuclear  medicine physics training and the need to explore pathways for improving nuclear medicine physics training opportunities. For these reasons, the two organizations formed a joint AAPM/SNMMI Ad Hoc Task Force on Nuclear Medicine Physics  Training. The mission of this task force was to assemble a representative group of stakeholders to:• Estimate the demand for board-certified nuclear medicine physicists in the next 5-10 years,• Identify the critical issues related to supplying an adequate number of physicists who have received the appropriate level of training in nuclear medicine physics, and• Identify approaches that may be considered to facilitate the training of nuclear medicine physicists.As a result, a task force was appointed and chaired by an active member of both organizations that included representation from the AAPM, SNMMI, the American Board of Radiology (ABR), the American Board of Science in Nuclear Medicine (ABSNM), and the Commission for the Accreditation of Medical Physics Educational Programs (CAMPEP). The Task Force first met at the AAPM Annual Meeting in Charlotte in July 2012 and has met regularly face-to-face, online, and by conference calls. This manuscript reports the findings of the Task Force, as well as recommendations to achieve the stated mission.


Assuntos
Diagnóstico por Imagem/normas , Educação Médica/normas , Física Médica/educação , Internato e Residência/normas , Medicina Nuclear/educação , Radioterapia (Especialidade)/educação , Competência Clínica , Currículo , Humanos , Relatório de Pesquisa
16.
ArXiv ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38764588

RESUMO

This submission comprises the proceedings of the 1st Virtual Imaging Trials in Medicine conference, organized by Duke University on April 22-24, 2024. The listed authors serve as the program directors for this conference. The VITM conference is a pioneering summit uniting experts from academia, industry and government in the fields of medical imaging and therapy to explore the transformative potential of in silico virtual trials and digital twins in revolutionizing healthcare. The proceedings are categorized by the respective days of the conference: Monday presentations, Tuesday presentations, Wednesday presentations, followed by the abstracts for the posters presented on Monday and Tuesday.

17.
EJNMMI Res ; 14(1): 32, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38536511

RESUMO

BACKGROUND: Standard measures of response such as Response Evaluation Criteria in Solid Tumors are ineffective for bone lesions, often making breast cancer patients that have bone-dominant metastases ineligible for clinical trials with potentially helpful therapies. In this study we prospectively evaluated the test-retest uptake variability of 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG) in a cohort of breast cancer patients with bone-dominant metastases to determine response criteria. The thresholds for 95% specificity of change versus no-change were then applied to a second cohort of breast cancer patients with bone-dominant metastases. METHODS: For this study, nine patients with 38 bone lesions were imaged with 18F-FDG in the same calibrated scanner twice within 14 days. Tumor uptake was quantified by the most commonly used PET parameter, the maximum tumor voxel normalized by dose and body weight (SUVmax) and also by the mean of a 1-cc maximal uptake volume normalized by dose and lean-body-mass (SULpeak). The asymmetric repeatability coefficients with confidence intervals for SUVmax and SULpeak were used to determine the limits of 18F-FDG uptake variability. A second cohort of 28 breast cancer patients with bone-dominant metastases that had 146 metastatic bone lesions was imaged with 18F-FDG before and after standard-of-care therapy for response assessment. RESULTS: The mean relative difference of SUVmax and SULpeak in 38 bone tumors of the first cohort were 4.3% and 6.7%. The upper and lower asymmetric limits of the repeatability coefficient were 19.4% and - 16.3% for SUVmax, and 21.2% and - 17.5% for SULpeak. 18F-FDG repeatability coefficient confidence intervals resulted in the following patient stratification using SULpeak for the second patient cohort: 11-progressive disease, 5-stable disease, 7-partial response, and 1-complete response with three inevaluable patients. The asymmetric repeatability coefficients response criteria for SULpeak changed the status of 3 patients compared to the standard Positron Emission Tomography Response Criteria in Solid Tumors of ± 30% SULpeak. CONCLUSION: In evaluating bone tumor response for breast cancer patients with bone-dominant metastases using 18F-FDG SUVmax, the repeatability coefficients from test-retest studies show that reductions of more than 17% and increases of more than 20% are unlikely to be due to measurement variability. Serial 18F-FDG imaging in clinical trials investigating bone lesions in these patients, such as the ECOG-ACRIN EA1183 trial, benefit from confidence limits that allow interpretation of response.

18.
Med Phys ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39008812

RESUMO

BACKGROUND: Lesion detection is one of the most important clinical tasks in positron emission tomography (PET) for oncology. An anthropomorphic model observer (MO) designed to replicate human observers (HOs) in a detection task is an important tool for assessing task-based image quality. The channelized Hotelling observer (CHO) has been the most popular anthropomorphic MO. Recently, deep learning MOs (DLMOs), mostly based on convolutional neural networks (CNNs), have been investigated for various imaging modalities. However, there have been few studies on DLMOs for PET. PURPOSE: The goal of the study is to investigate whether DLMOs can predict HOs better than conventional MOs such as CHO in a two-alternative forced-choice (2AFC) detection task using PET images with real anatomical variability. METHODS: Two types of DLMOs were implemented: (1) CNN DLMO, and (2) CNN-SwinT DLMO that combines CNN and Swin Transformer (SwinT) encoders. Lesion-absent PET images were reconstructed from clinical data, and lesion-present images were reconstructed with adding simulated lesion sinogram data. Lesion-present and lesion-absent PET image pairs were labeled by eight HOs consisting of four radiologists and four image scientists in a 2AFC detection task. In total, 2268 pairs of lesion-present and lesion-absent images were used for training, 324 pairs for validation, and 324 pairs for test. CNN DLMO, CNN-SwinT DLMO, CHO with internal noise, and non-prewhitening matched filter (NPWMF) were compared in the same train-test paradigm. For comparison, six quantitative metrics including prediction accuracy, mean squared errors (MSEs) and correlation coefficients, which measure how well a MO predicts HOs, were calculated in a 9-fold cross-validation experiment. RESULTS: In terms of the accuracy and MSE metrics, CNN DLMO and CNN-SwinT DLMO showed better performance than CHO and NPWMF, and CNN-SwinT DLMO showed the best performance among the MOs evaluated. CONCLUSIONS: DLMO can predict HOs more accurately than conventional MOs such as CHO in PET lesion detection. Combining SwinT and CNN encoders can improve the DLMO prediction performance compared to using CNN only.

19.
Res Sq ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38313279

RESUMO

BACKGROUND: Standard measures of response such as Response Evaluation Criteria in Solid Tumors are ineffective for bone lesions, often making breast cancer patients with bone-dominant metastases ineligible for clinical trials with potentially helpful therapies. In this study we prospectively evaluated the test-retest uptake variability of 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG) in a cohort of breast cancer patients with bone-dominant metastases to determine response criteria. The thresholds for 95% specificity of change versus no-change were then applied to a second cohort of breast cancer patients with bone-dominant metastases.In this study, nine patients with 38 bone lesions were imaged with 18F-FDG in the same calibrated scanner twice within 14 days. Tumor uptake was quantified as the maximum tumor voxel normalized by dose and body weight (SUVmax) and the mean of a 1-cc maximal uptake volume normalized by dose and lean-body-mass (SULpeak). The asymmetric repeatability coefficients with confidence intervals of SUVmax and SULpeak were used to determine limits of 18F-FDG uptake variability. A second cohort of 28 breast cancer patients with bone-dominant metastases that had 146 metastatic bone lesions was imaged with 18F-FDG before and after standard-of-care therapy for response assessment. RESULTS: The mean relative difference of SUVmax in 38 bone tumors of the first cohort was 4.3%. The upper and lower asymmetric limits of the repeatability coefficient were 19.4% and -16.3%, respectively. The 18F-FDG repeatability coefficient confidence intervals resulted in the following patient stratification for the second patient cohort: 11-progressive disease, 5-stable disease, 7-partial response, and 1-complete response with three inevaluable patients. The asymmetric repeatability coefficients response criteria changed the status of 3 patients compared to standard the standard Positron Emission Tomography Response Criteria in Solid Tumors of ±30% SULpeak. CONCLUSIONS: In evaluating bone tumor response for breast cancer patients with bone-dominant metastases using 18F-FDG uptake, the repeatability coefficients from test-retest studies show that reductions of more than 17% and increases of more than 20% are unlikely to be due to measurement variability. Serial 18F-FDG imaging in clinical trials investigating bone lesions from these patients, such as the ECOG-ACRIN EA1183 trial, benefit from confidence limits that allow interpretation of response.

20.
JCO Precis Oncol ; 8: e2300687, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635935

RESUMO

Radiomics, the science of extracting quantifiable data from routine medical images, is a powerful tool that has many potential applications in oncology. The Response Evaluation Criteria in Solid Tumors Working Group (RWG) held a workshop in May 2022, which brought together various stakeholders to discuss the potential role of radiomics in oncology drug development and clinical trials, particularly with respect to response assessment. This article summarizes the results of that workshop, reviewing radiomics for the practicing oncologist and highlighting the work that needs to be done to move forward the incorporation of radiomics into clinical trials.


Assuntos
Neoplasias , Medicina de Precisão , Humanos , Medicina de Precisão/métodos , Critérios de Avaliação de Resposta em Tumores Sólidos , Radiômica , Oncologia , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA