Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Nutr ; 63(1): 323-335, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37874350

RESUMO

PURPOSE: The primary aim of this study was to examine whether a glycine-rich collagen peptides (CP) supplement could enhance sleep quality in physically active men with self-reported sleep complaints. METHODS: In a randomized, crossover design, 13 athletic males (age: 24 ± 4 years; training volume; 7 ± 3 h·wk1) with sleep complaints (Athens Insomnia Scale, 9 ± 2) consumed CP (15 g·day1) or a placebo control (CON) 1 h before bedtime for 7 nights. Sleep quality was measured with subjective sleep diaries and actigraphy for 7 nights; polysomnographic sleep and core temperature were recorded on night 7. Cognition, inflammation, and endocrine function were measured on night 7 and the following morning. Subjective sleepiness and fatigue were measured on all 7 nights. The intervention trials were separated by ≥ 7 days and preceded by a 7-night familiarisation trial. RESULTS: Polysomnography showed less awakenings with CP than CON (21.3 ± 9.7 vs. 29.3 ± 13.8 counts, respectively; P = 0.028). The 7-day average for subjective awakenings were less with CP vs. CON (1.3 ± 1.5 vs. 1.9 ± 0.6 counts, respectively; P = 0.023). The proportion of correct responses on the baseline Stroop cognitive test were higher with CP than CON (1.00 ± 0.00 vs. 0.97 ± 0.05 AU, respectively; P = 0.009) the morning after night 7. There were no trial differences in core temperature, endocrine function, inflammation, subjective sleepiness, fatigue and sleep quality, or other measures of cognitive function or sleep (P > 0.05). CONCLUSION: CP supplementation did not influence sleep quantity, latency, or efficiency, but reduced awakenings and improved cognitive function in physically active males with sleep complaints.


Assuntos
Privação do Sono , Sonolência , Adulto , Humanos , Masculino , Adulto Jovem , Cognição , Fadiga/tratamento farmacológico , Fadiga/psicologia , Inflamação , Sono/fisiologia , Privação do Sono/tratamento farmacológico , Estudos Cross-Over
5.
Arch Dis Child ; 109(4): 308-313, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38253431

RESUMO

BACKGROUND AND OBJECTIVE: Cardiorespiratory polygraphy (CRP) is the predominant technology used to diagnose obstructive sleep apnoea (OSA) in tertiary centres in the UK. Nocturnal pulse oximetry (NPO) is, however, cheaper and more accessible. This study evaluated the ability of NPO indices to predict OSA in typically developing (TD) children. METHODS: Indices from simultaneous NPO and CRP recordings were compared in TD children (aged 1-16 years) referred to evaluate OSA in three tertiary centres. OSA was defined as an obstructive apnoea-hypopnoea index (OAHI) ≥1 event/hour. Receiver operating characteristic curves assessed the diagnostic accuracy of NPO indices including ODI3 (3% Oxygen Desaturation Index, ODI4 (4% Oxygen Desaturation Index), delta 12 s index and minimum oxygen saturation. Two-by-two tables were generated to determine the sensitivities and specificities of whole number cut-off values for predicting OAHIs ≥1, 5 and 10 events/hour. RESULTS: Recordings from 322 TD children, 197 male (61.2%), median age 4.9 years (range 1.1-15.6), were reviewed. OAHI was ≥1/hour in 144 (44.7%), ≥5/hour in 61 (18.9%) and ≥10/hour in 28 (8.7%) cases. ODI3 and ODI4 had the best diagnostic accuracy. ODI3 ≥7/hour and ODI4 ≥4/hour predicted OSA in TD children with sensitivities/specificities of 57.6%/85.4% and 46.2%/91.6%, respectively. ODI3 ≥8/hour was the best predictor of OAHI ≥5/hour (sensitivity 82.0%, specificity 84.3%). CONCLUSION: Raised ODI3 and ODI4 predict OSA in TD children with high specificity but variable sensitivity. NPO may be an alternative to diagnose moderate-severe OSA if access to CRP is limited. Low sensitivities to detect mild OSA mean that confirmatory CRP is needed if NPO is normal.


Assuntos
Apneia Obstrutiva do Sono , Criança , Humanos , Masculino , Lactente , Pré-Escolar , Adolescente , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Oximetria , Oxigênio , Sensibilidade e Especificidade
6.
Arch Dis Child ; 107(1): 7-11, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33975822

RESUMO

Narcolepsy is a chronic disabling neurological sleep disorder that requires lifelong treatment. We have outlined the clinical features of narcolepsy, the assessment and diagnosis process and have summarised the existing treatment options for children and adolescents with narcolepsy. In the future, the approach to management of paediatric narcolepsy should ideally be in a multidisciplinary setting, involving specialists in sleep medicine, sleep physiology, neurologists and psychologists/psychiatrists. A multidisciplinary approach will help to manage the potential impact of narcolepsy on children and adolescents who are in a stage of their life that is critical to their physical, emotional and social development and their academic attainment.


Assuntos
Narcolepsia/diagnóstico , Narcolepsia/terapia , Actigrafia/métodos , Adolescente , Cataplexia/diagnóstico , Cataplexia/terapia , Estimulantes do Sistema Nervoso Central/uso terapêutico , Criança , Exercício Físico , Humanos , Equipe de Assistência ao Paciente , Polissonografia/métodos , Sono , Medicamentos Indutores do Sono/uso terapêutico , Promotores da Vigília/uso terapêutico
7.
Front Psychiatry ; 11: 285, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32425820

RESUMO

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) is common in children with Down syndrome (DS) and is associated with adverse health and cognitive outcomes. Daytime clinical assessment is poorly predictive of OSA, so regular screening with sleep studies is recommended. However, sleep studies are costly and not available to all children worldwide. We aimed to evaluate the psychometric properties and predictive value of a newly developed screening questionnaire for OSA in this population. METHODS: 202 children aged 6 months to 6th birthday with DS were recruited, of whom 188 completed cardio-respiratory sleep studies to generate an obstructive apnea hypopnea index (OAHI). Parents completed the 14-item Down syndrome OSA screening questionnaire. Responses were screened, a factor analysis undertaken, internal consistency calculated and receiver operator characteristic (ROC) curves drawn to generate an area under the curve (AUC) to assess criterion related validity. RESULTS: Of 188 children who completed cardiorespiratory sleep studies; parents completed the screening questionnaire for 186. Of this study population 15.4% had moderate to severe OSA defined by an OAHI of ≥5/h. Sixty-three (33.9%) participants were excluded due to "unsure" responses or where questions were not answered. Using the remaining 123 questionnaires a four-factor solution was found, with the 1st factor representing breathing related symptoms, explaining a high proportion of the variance. Internal consistency was acceptable with a Cronbach alpha of 0.87. ROC curves for the total score generated an AUC statistic of 0.497 and for the breathing subscale an AUC of 0.603 for moderate to severe OSA. CONCLUSION: A well designed questionnaire with good psychometric properties had limited predictive value to screen for moderate to severe OSA in young children with DS. The use of a screening questionnaire is not recommended. Screening for OSA in this population requires objective sleep study measures.

8.
BMJ Paediatr Open ; 3(1): e000551, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31799451

RESUMO

OBJECTIVE: Despite the success of behavioural sleep support interventions in the third sector, sleep support is not universally available for families in the UK. The aim of the study was to provide evidence of efficacy and to propose a delivery model for integrated sleep support for families of vulnerable children. DESIGN AND SETTING: A sleep support intervention was carried out in Sheffield Local Authority evaluated using a preintervention and postintervention study design by Sheffield Children's National Health Service (NHS) Trust. PARTICIPANTS: Fifty-six children aged 6-16 years with significant sleep problems were recruited; 39 completed the intervention and evaluation. INTERVENTIONS: Basic sleep education and an individualised programme was delivered by a sleep practitioner. Follow-on telephone support was provided to empower the parent (and/or young person) to carry out the sleep programme at home. An integrated NHS and Local Authority delivery model was designed and implemented. RESULTS: Parents' ratings of their child's ability to self-settle improved from 1.1/10 to 6.4/10 (p<0.05). Mean Warwick-Edinburgh Mental Well-being Scale scores improved significantly for parents/carers (MD 5.16, 95%CIs 2.62 to 7.69, p<0.05). Children who completed the intervention gained on average an extra 2.4 hours sleep a night. There was reduction in healthcare utilisation, illnesses and medication use. CONCLUSIONS: The behavioural approach to sleep support for these vulnerable groups of children is highly effective. Follow-on individual support to empower parents is key to achieving success. Sleep support can be implemented in NHS and Local Authority services by integration into the existing workforce using a cross-agency model.

9.
Sleep Med ; 63: 88-97, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31606654

RESUMO

AIMS: To compare sleep in infants and toddlers with Down syndrome (DS) to typically developing controls, including differences in snoring and sleep ecology (sleep setting and parent behaviors). METHODS: Parents of 104 children with DS and 489 controls aged 6-36 months completed the Brief Infant Sleep Questionnaire (BISQ). We explored group differences, controlling for demographic variables. RESULTS: Parents of children with DS reported more sleep problems (45% v 19%), snoring (19% vs 2%), room-sharing (37% vs 17%), as well as less night-time sleep (55 mins) and total sleep over 24 h (38 mins). They were more likely to be present when their child fell asleep (OR 4.40). Snoring increased night waking but did not limit night-time/24-hour sleep. However, parental presence was associated with 55 min less night-time and 64 min less 24-hour sleep. After controlling for snoring and parental presence, children with DS slept less at night (38 mins) but more during the day (21 mins) with no significant difference in 24-hour sleep. CONCLUSIONS: Overall, significant differences in sleep patterns, problems, and ecology were found between children with DS and controls. Parental presence at settling, not snoring, explained most differences, including over an hour's less 24-hour sleep. Early intervention programmes that promote self-soothing skills could prevent the burden of sleep loss in young children with DS.


Assuntos
Síndrome de Down/complicações , Síndromes da Apneia do Sono/epidemiologia , Distúrbios do Início e da Manutenção do Sono/epidemiologia , Sono/fisiologia , Ronco/complicações , Inquéritos e Questionários , Estudos de Casos e Controles , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pais
10.
Arch Dis Child ; 104(5): 476-481, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30455364

RESUMO

OBJECTIVE: To evaluate the success rates of home cardiorespiratory polygraphy in children under investigation for sleep-disordered breathing and parent perspectives on equipment use at home. DESIGN: Prospective observational study. SETTING: Sheffield, Evelina London and Southampton Children's Hospitals. PATIENTS: Data are reported for 194 research participants with Down syndrome, aged 0.5-5.9 years across the three centres and 61 clinical patients aged 0.4-19.5 years from one centre, all of whom had home cardiorespiratory polygraphy including respiratory movements, nasal pressure flow, pulse oximetry, body position and motion. MAIN OUTCOME MEASURES: Percentage of home cardiorespiratory studies successfully acquiring ≥4 hours of artefact-free data at the first attempt. Parental report of ease of use of equipment and preparedness to repeat home diagnostics in the future. RESULTS: 143/194 (74%; 95% CI 67% to 79%) of research participants and 50/61 (82%; 95% CI 71% to 90%) of clinical patients had successful home cardiorespiratory polygraphy at the first attempt. Some children required multiple attempts to achieve a successful study. Overall, this equated to 1.3 studies per research participant and 1.2 studies per clinical child. The median artefact-free sleep time for successful research studies was 515 min (range 261-673) and for clinical studies 442 min (range 291-583). 84% of research and 87% of clinical parents expressed willingness to repeat home cardiorespiratory polygraphy in the future. 67% of research parents found the equipment 'easy or okay' to use, while 64% of clinical parents reported it as 'easy' or 'very easy'. CONCLUSIONS: Home cardiorespiratory polygraphy offers an acceptable approach to the assessment of sleep-disordered breathing in children.


Assuntos
Serviços Hospitalares de Assistência Domiciliar , Polissonografia/métodos , Síndromes da Apneia do Sono/diagnóstico , Adolescente , Criança , Pré-Escolar , Síndrome de Down/complicações , Inglaterra , Humanos , Lactente , Monitorização Fisiológica/métodos , Oximetria , Aceitação pelo Paciente de Cuidados de Saúde , Estudos Prospectivos , Síndromes da Apneia do Sono/etiologia , Adulto Jovem
11.
Respirology ; 13(5): 708-15, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18713092

RESUMO

BACKGROUND AND OBJECTIVE: Avoidance of sleep in the supine position is recommended in the management of position-dependent OSA hypopnoea syndrome (OSAHS). Our aim was to evaluate the efficacy of a thoracic anti-supine band (TASB), designed to mimic the so-called 'tennis ball technique', compared with nasal CPAP (nCPAP). METHODS: Twenty adults with mild to moderately severe position-dependent OSAHS (mean AHI +/- SD) 22.7 +/- 12.0/H (range 6.0-51.2); AHI supine, 59.6 +/- 27.5/H, were included in a randomized cross-over trial. Portable sleep studies were undertaken at baseline and after 1 month on each treatment. A successful treatment outcome was defined as AHI

Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Equipamentos e Provisões , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Decúbito Dorsal/fisiologia , Adulto , Idoso , Estudos Cross-Over , Humanos , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Cooperação do Paciente , Qualidade de Vida , Resultado do Tratamento
12.
Arch Dis Child ; 103(10): 962-967, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29760010

RESUMO

OBJECTIVE: Children with Down syndrome are at high risk of obstructive sleep apnoea (OSA) and screening is recommended. Diagnosis of OSA should be confirmed with multichannel sleep studies. We aimed to determine whether home pulse oximetry (HPO) discriminates children at high risk of OSA, who need further diagnostic multichannel sleep studies. DESIGN: Cross-sectional prospective study in a training sample recruited through three UK centres. Validation sample used single-centre retrospective analysis of clinical data. PATIENTS: Children with Down syndrome aged 0.5-6 years. INTERVENTION: Diagnostic multichannel sleep study and HPO. MAIN OUTCOME MEASURES: Sensitivity and specificity of HPO to predict moderate-to-severe OSA. RESULTS: 161/202 children with Down syndrome met quality criteria for inclusion and 25 had OSA. In this training sample, the best HPO parameter predictors of OSA were the delta 12 s index >0.555 (sensitivity 92%, specificity 65%) and 3% oxyhaemoglobin (SpO2) desaturation index (3% ODI)>6.15 dips/hour (sensitivity 92%, specificity 63%). Combining variables (delta 12 s index, 3% ODI, mean and minimum SpO2) achieved sensitivity of 96% but reduced specificity to 52%. All predictors retained or improved sensitivity in a clinical validation sample of 50 children with variable loss of specificity, best overall was the delta 12 s index, a measure of baseline SpO2 variability (sensitivity 92%; specificity 63%). CONCLUSIONS: HPO screening could halve the number of children with Down syndrome needing multichannel sleep studies and reduce the burden on children, families and health services alike. This approach offers a practical universal screening approach for OSA in Down syndrome that is accessible to the non-specialist paediatrician.


Assuntos
Síndrome de Down/epidemiologia , Programas de Rastreamento/métodos , Oximetria/métodos , Apneia Obstrutiva do Sono , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Masculino , Polissonografia/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/prevenção & controle , Reino Unido/epidemiologia
13.
BMJ Paediatr Open ; 1(1): e000173, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29637169

RESUMO

OBJECTIVE: To determine the inter-observer agreement of a respiratory rate (RR) count on a child when assessed by three independent observers. DESIGN: The RR of 169 children (age range: 3 days to 15 years) was measured by three independent observers over a 3-month period. The first RR was taken by different healthcare professionals (HCPs) from within the hospital using their own preferred method of measurement. A further count of RR was then taken by two observers from the research team simultaneously within 30 min of the first measurement, using the WHO-recommended method of measurement. RESULTS: 507 RR measurements were taken on 169 children. Median RR showed a 4 beats per minute (bpm) difference between the HCP (median RR 32 bpm) and the researchers (median RR 28 bpm). The 95% limits of agreement between the first measurement and second and third measurements were -10.2 to 17.7 bpm and -11.4 to 18.7 bpm, respectively. For simultaneous measurements, the 95% limits of agreement were -7.1 to 7.0 bpm. 81 children had a RR > 95th centile for their age and an even poorer level of agreement was seen in these children than in those whose RR was within normal range. In only 27 of these 81 children (33%) did all three observers agree on the presence of a raised RR. CONCLUSIONS: Inter-observer agreement for the measurement of RR in children is poor. The effect that this variation has on the clinical assessment and subsequent management of a child may be significant. These findings highlight the need for a robust review of our current measurement methods and interpretation of an important vital sign.

15.
Sleep ; 26(6): 721-6, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14572126

RESUMO

STUDY OBJECTIVES: To determine the therapeutic efficacy and viability of a novel oral interface for continuous positive airway pressure (CPAP) compared with conventional nasal interfaces. DESIGN: A randomized single-blind crossover study. SETTING: Hospital-based sleep laboratory. PATIENTS OR PARTICIPANTS: 21 CPAP-naïve patients with obstructive sleep apnea (baseline apnea-hypopnea index, 85 +/- 36) INTERVENTIONS: Nasal CPAP and oral CPAP MEASUREMENTS AND RESULTS: Patients were each treated for two 4-week periods using nasal CPAP and oral CPAP. The CPAP titrations were undertaken at the start of each treatment arm. Outcome measures were recorded at baseline and at the end of each treatment arm. These included polysomnography variables, CPAP compliance, subjective sleepiness, obstructive sleep apnea symptom ratings, and adverse effects. There were no significant differences between oral and nasal interfaces for the on-CPAP frequency of apneas and hypopneas (mean difference, nasal-oral [95%CI] = -4.6[-10.1-1.0]/h; P = 0.06) or arousals (-3.0 [-7.8-1.8]/h; P = 0.23). There were also no statistically significant differences between interfaces for scores on the Epworth Sleepiness Scale (-0.7 [-3.1-1.7]; P = 0.20), obstructive sleep apnea symptoms (-7.7 [-17.7-2.4]; P = 0.052), CPAP compliance (0.3 [-0.5-1.1] h/night; P = 0.50), CPAP pressure (0.05 [-0.66-0.76] cmH20; P = 0.73), CPAP side effects scores (-2.0 [-5.3-1.4]; P = 0.23), or mask preference (P = 0.407). In addition, both nasal and oral interfaces significantly improved polysomnographic variables, Epworth Sleepiness Scale scores, obstructive sleep apnea symptoms, and CPAP compliance from baseline (all P < 0.05). CONCLUSIONS: This preliminary study indicates that oral CPAP has similar efficacy to traditionally applied nasal CPAP in treating obstructive sleep apnea. Additional large studies are required to determine the range of clinical situations where oral CPAP is indicated.


Assuntos
Respiração com Pressão Positiva/métodos , Apneia Obstrutiva do Sono/terapia , Administração Oral , Estudos Cross-Over , Humanos , Polissonografia , Estudos Prospectivos , Índice de Gravidade de Doença , Método Simples-Cego , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/diagnóstico , Fases do Sono/fisiologia , Inquéritos e Questionários , Vigília/fisiologia
16.
Chest ; 125(1): 118-26, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14718430

RESUMO

STUDY OBJECTIVES: The effect of therapy using a cervicomandibular support collar (CMSC) to manage obstructive sleep apnea (OSA) was compared with standard therapy, nasal continuous positive airway pressure (nCPAP). DESIGN: Subjects received treatment with CMSC or nCPAP each for 1 month in random order. The study was analyzed on an intention-to-treat basis. SETTING: Tom McKendrick Sleep Laboratory, Dunedin Hospital. PARTICIPANTS: Ten adult subjects with mild-to-moderate OSA (apnea-hypopnea index [AHI], 24 +/- 13/h slept [mean +/- SD]) completed the study. INTERVENTIONS: The CMSC was designed to prevent mandibular movement and hold the head in slight extension, thus preventing the postural changes that might contribute to OSA. Positioning of the CMSC was confirmed by an externally applied cervical range of motion (CROM) instrument and by cephalometry. Subjects were carefully instructed in the use of each device and completed a symptom diary. After 1 month, subjects underwent polysomnography with each of the allocated devices in situ, and symptom questionnaires were administered. MEASUREMENTS AND RESULTS: Treatment success (AHI 10/h to

Assuntos
Pescoço , Aparelhos Ortopédicos , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Cefalometria , Pressão Positiva Contínua nas Vias Aéreas , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Resultado do Tratamento
17.
Sleep Breath ; 6(2): 69-76, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12075481

RESUMO

The polysomnographic efficacy of a novel tongue-stabilizing device (TSD) in the treatment of snoring and sleep-disordered breathing (SDB) was evaluated in this pilot study. Six current users of the TSD with SDB underwent polysomnography with and without the TSD in situ in a randomized crossover design. The TSD significantly lowered the frequency of snores per hour slept (61- to 70-dB range) (no TSD: mean = 41/h slept +/- 52 SD; TSD: 8/h slept +/- 16 SD; P = 0.046) but did not alter snoring in the other decibel ranges (all Ps > 0.1). Trends were found for reductions in the frequency of apneas plus hypopneas (no TSD: 26/h slept +/- 17/h slept; TSD: 15/h slept +/- 13; P = 0.06) and oxygen desaturations of 4% or more (no TSD: 10/h slept +/- 10; TSD: 5/h slept +/- 5; P = 0.09). Significant improvements in microarousal frequency with the TSD were found (no TSD: 34/h slept +/- 16; TSD: 22/h slept +/- 14; P = 0.004). Significant reductions in percentage of Stage 1 sleep with the TSD were also demonstrated (no TSD: 10 +/- 3%; TSD: 8 +/- 2%; P = 0.03). The results of this small pilot study indicate that the TSD may be effective in reducing snoring severity and microarousals, with favorable trends for reducing SDB severity in selected individuals. Additional larger prospective studies are required to identify suitable candidates for TSD use in the treatment of snoring and SDB.


Assuntos
Contenções Ortodônticas , Polissonografia/métodos , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia , Língua/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Índice de Gravidade de Doença
18.
Sleep Breath ; 8(4): 193-200, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15611894

RESUMO

This study aimed to evaluate the effectiveness of elevated posture in the management of obstructive sleep apnea (OSA). Fourteen subjects presenting with mild-moderate OSA, (apnea-hypopnea index [AHI] 10 to 60/h), were included in a randomized crossover investigation. A shoulder-head elevation pillow (SHEP) was compared with nasal continuous positive airway pressure (nCPAP) therapy. Treatment success was defined as AHI10<16/h. Four subjects achieved treatment success with the SHEP and three achieved partial success. The remaining seven subjects were treatment failures. In contrast, success was achieved with nCPAP in 12 subjects. One subject achieved partial success and one was a treatment failure. With the SHEP, the mean AHI decreased from 27+/-12/h to 21+/-17/h. With nCPAP, the mean AHI was 5+/-3/h; (p=0.008 for the difference between treatments). Although somewhat variable, these data provide evidence that elevated posture during sleep is helpful in the management of OSA in some individuals. Results support the use of elevated posture as second-line therapy in the management of OSA. However, no relationships could be identified between baseline data, including the identification of positional OSA, and objective outcomes that might predict patients who are likely to benefit from treatment in an elevated position.


Assuntos
Postura , Apneia Obstrutiva do Sono/prevenção & controle , Índice de Massa Corporal , Pressão Positiva Contínua nas Vias Aéreas/métodos , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/instrumentação , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia
19.
Sleep Breath ; 6(3): 115-24, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12244491

RESUMO

The efficacy of a titratable mandibular advancement splint (MAS) for the management of obstructive sleep apnea (OSA) was investigated in relation to supine cephalometric variables. Fourteen adults with diagnosed OSA were recruited following an initial polysomnogram. Supine cephalographic radiographs were taken at baseline and subjects wore the MAS nightly for 6 to 8 weeks. The polysomnogram and cephalogram were repeated with the MAS at maximal titration. The MAS resulted in complete or partial treatment response in all subjects as measured by the improvement in mean apnea/hypopnea index (AHI) (baseline AHI 34 +/- 22/hr, with MAS 10 +/- 5/hr; p = 0.001). The perpendicular distance between the hyoid bone and the mandibular plane (HYML) measured in awake subjects decreased with the MAS (baseline HYML 25.3 +/- 7.8 mm, with MAS 16.5 +/- 9.6 mm; p = 0.002). Baseline HYML was the only cephalometric variable associated with a successful clinical outcome. It was strongly linked to improvements in AHI (adjusted R(2) = 0.37, p = 0.012) and arousals (adjusted R(2) = 0.455, p = 0.005). We conclude that the MAS is an effective therapy for OSA and baseline HYML is an important predictor of improvement. Improvements in AHI may be explained by the MAS maintaining the new or existing relationship of the hyoid and its surrounding structures, thus preventing obstruction in the upper airway during sleep.


Assuntos
Cefalometria , Avanço Mandibular/instrumentação , Contenções Periodontais , Apneia Obstrutiva do Sono/terapia , Adulto , Eletroencefalografia , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Sono REM/fisiologia , Resultado do Tratamento
20.
Sleep Breath ; 8(2): 61-72, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15211390

RESUMO

STUDY OBJECTIVE: To examine levels of sleep-disordered breathing, daytime sleepiness, and impaired performance in 60 motor vehicle crash drivers and 60 controls matched for age, gender, and body mass index. MEASUREMENTS AND RESULTS: All participants underwent polysomnography and daytime function assessments. Cases reported significantly higher levels of driver sleepiness (% sleepiness: mean +/- SD; cases: 26 +/- 17%; controls: 16 +/- 12%; p = 0.003) and demonstrated slower reaction times on a sustained attention task ( p = 0.02). There was a trend for more objective sleepiness in cases (maintenance of wakefulness test: cases: 17 +/- 4 minutes; controls: 18 +/- 3 minutes, p = 0.06) despite no differences in general subjective sleepiness (Epworth score: cases: 8 +/- 4; controls: 8 +/- 4; p = 0.93). There were no significant differences in polysomnography measures between groups (apneas + hypopneas per hour slept: cases: 8 +/- 9; controls: 9 +/- 16; p = 0.89; arousals per hour slept: cases: 18 +/- 8; controls: 21 +/- 12; p = 0.11). CONCLUSION: Crash drivers demonstrated significantly more driver sleepiness, slower reaction times and a trend for greater objective sleepiness compared with well-matched controls. However, the findings in crash drivers were independent of medical causes of sleep fragmentation, with both cases and controls showing moderate levels of unrecognized mild sleep-disordered breathing. Crash prevention strategies should focus on increasing personal awareness of the risks of sleepiness behind the wheel in all individuals.


Assuntos
Acidentes de Trânsito/estatística & dados numéricos , Condução de Veículo/estatística & dados numéricos , Ritmo Circadiano , Distúrbios do Sono por Sonolência Excessiva/epidemiologia , Síndromes da Apneia do Sono/epidemiologia , Adulto , Índice de Massa Corporal , Estudos de Casos e Controles , Distúrbios do Sono por Sonolência Excessiva/diagnóstico , Eletroencefalografia , Fadiga/epidemiologia , Feminino , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Tempo de Reação , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/diagnóstico , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA