Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 7(9): 1079-1083, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34454876

RESUMO

Cardiac resynchronization therapy (CRT) can improve heart function and decrease arrhythmic events. We tested whether CRT altered circulating markers of calcium handling and sudden death risk. Circulating cardiac sodium channel messenger RNA (mRNA) splicing variants indicate arrhythmic risk, and a reduction in sarco/endoplasmic reticulum calcium adenosine triphosphatase 2a (SERCA2a) is thought to diminish contractility in heart failure. CRT was associated with a decreased proportion of circulating, nonfunctional sodium channels and improved SERCA2a mRNA expression. Patients without CRT did not have improvement in the biomarkers. These changes might explain the lower arrhythmic risk and improved contractility associated with CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Biomarcadores , Cálcio , Morte Súbita , Humanos , Retículo Sarcoplasmático
2.
J Cardiovasc Electrophysiol ; 18(2): 192-5, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17239139

RESUMO

BACKGROUND: Dual-coil implantable defibrillator (ICD) leads with true bipolar pacing and sensing (quadripolar leads) have been introduced to provide improved sensing characteristics without sacrificing defibrillation efficacy. Electrode configuration has been shown to have little effect on the amplitude or slew rate of the intracardiac electrogram, but does have an effect on the duration of the sensed electrogram. Closer spacing of the electrodes and smaller surface area of the anode may, therefore, result in a different latency of sensing relative to the onset of the QRS complex. METHODS: We tested the difference in ventricular sensing latency between integrated bipolar and true bipolar electrode configurations in 40 patients undergoing ICD implantation for standard indications (Medtronic Sprint Quattro lead in 26 and St. Jude Riata in 16). In addition, we compared R wave amplitude, pacing threshold, impedance, and slew rate. RESULTS: Sensing latency was significantly longer in the true bipolar configuration (Medtronic Sprint Quattro 45.2 +/- 14.7 msec in the true bipolar configuration, vs 37.4 +/- 18.2 msec in the integrated bipolar configuration, and St. Jude Riata, 43.5 +/- 9.8 msec true bipolar, vs 33.8 +/- 10.1 msec integrated bipolar, P < 0.01). There was no difference in R wave amplitude or slew rate. Pacing threshold and impedance were also greater in the true bipolar configuration than in the integrated bipolar configuration. CONCLUSION: The true bipolar configuration has a longer sensing latency than the integrated bipolar configuration. In some patients, this may require a longer programmed AV delay to avoid ventricular pseudofusion.


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas/terapia , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese
3.
J Cardiovasc Electrophysiol ; 18(3): 310-7, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17257123

RESUMO

BACKGROUND: Interatrial conduction occurs via discrete pathways along the coronary sinus musculature, fossa ovalis region, and Bachman's bundle. We assessed the feasibility of altering interatrial conduction by selectively ablating two of these conduction pathways using a novel mesh electrode ablation catheter. METHODS: Circular radiofrequency energy catheter ablation lesions were created in the proximal coronary sinus in four dogs and in both the fossa ovalis and the proximal coronary sinus regions in seven pigs. Interatrial conduction was assessed by analyzing intracardiac electrogram and noncontact isopotential mapping data. Inducibility of atrial fibrillation was assessed before and after ablation (in six pigs). RESULTS: Ablation lesions in the proximal coronary sinus eliminated interatrial conduction along the coronary sinus musculature in four dogs and five of seven pigs. Ablation lesions in the fossa ovalis region eliminated interatrial conduction via midseptal pathways in six of seven pigs. Atrial fibrillation, inducible in five of seven pigs at baseline, was rendered noninducible in all five. There was no adverse effect on AV nodal conduction. CONCLUSIONS: (1) Using a novel mesh electrode ablation catheter, we were able to ablate interatrial conduction pathways along the proximal coronary sinus and fossa ovalis regions. (2) This altered interatrial conduction and altered atrial fibrillation inducibility and maintenance. (3) Catheter ablation of interatrial conduction pathways may be useful in the therapy of atrial fibrillation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Animais , Fibrilação Atrial/fisiopatologia , Nó Atrioventricular/fisiopatologia , Ablação por Cateter/efeitos adversos , Modelos Animais de Doenças , Cães , Desenho de Equipamento , Estudos de Viabilidade , Sistema de Condução Cardíaco/fisiopatologia , Nó Sinoatrial/patologia , Suínos , Fibrilação Ventricular/etiologia
4.
J Interv Card Electrophysiol ; 9(2): 203-6, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14574032

RESUMO

Over the past decade, four randomized, controlled trials have evaluated therapies for prevention of sudden cardiac death in patients with coronary disease. Three of the four trials have shown significant reductions in mortality with implanted defibrillators. Two studies failed to demonstrate any benefit from pharmacologic antiarrhythmic therapy. The results of these studies in similar patient populations have erased any doubt regarding the ability of implanted defibrillators to reduce the risk of sudden death in patients with coronary disease. Our major challenge at this time is understanding how best to utilize this therapy in order to bring the benefit to the maximum number of patients while minimizing expense.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Prevenção Primária , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis , Parada Cardíaca/mortalidade , Parada Cardíaca/fisiopatologia , Parada Cardíaca/terapia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Volume Sistólico/fisiologia , Estados Unidos/epidemiologia
6.
J Am Coll Cardiol ; 53(6): 471-9, 2009 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-19195603

RESUMO

OBJECTIVES: Because risk stratification with electrophysiological study (EPS) improves efficiency but is invasive, we sought to determine whether noninvasive microvolt T-wave alternans (MTWA) testing could identify patients who benefit from implantable cardioverter-defibrillators (ICDs) as well as EPS. BACKGROUND: Prevention of sudden cardiac death on the basis of left ventricular ejection fraction (LVEF) alone is inefficient, because most ICDs never deliver therapy. METHODS: The ABCD (Alternans Before Cardioverter Defibrillator) trial is a multicenter prospective study that enrolled patients with ischemic cardiomyopathy (LVEF < or =0.40) and nonsustained ventricular tachycardia. All patients underwent MTWA and EPS. ICDs were mandated if either test was positive. RESULTS: Of 566 patients followed for a median of 1.9 years, 39 (7.5%) met the primary end point of appropriate ICD discharge or sudden death at 1 year. As hypothesized, primary analysis showed that MTWA achieved 1-year positive (9%) and negative (95%) predictive values that were comparable to EPS (11% and 95%, respectively). In addition, secondary analysis showed that at the pre-specified 1-year end point, event rates were significantly higher in patients with both a positive MTWA-directed strategy (hazard ratio: 2.1, p = 0.03) and a positive EPS-directed strategy (hazard ratio: 2.4, p = 0.007). Moreover, the event rate in patients with both negative MTWA test and EPS was lower than in those with 2 positive tests (2% vs. 12%; p = 0.017). CONCLUSIONS: The ABCD study is the first trial to use MTWA to guide prophylactic ICD insertion. Risk stratification strategies using noninvasive MTWA versus invasive EPS are comparable at 1 year and complementary when applied in combination. Strategies employing MTWA, EPS, or both might identify subsets of patients least likely to benefit from ICD insertion. (Study to Compare TWA Test and EPS Test for Predicting Patients at Risk for Life-Threatening Heart Rhythms [ABCD Study]; NCT00187291).


Assuntos
Eletrofisiologia Cardíaca , Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Isquemia Miocárdica/terapia , Taquicardia Ventricular/terapia , Idoso , Desfibriladores Implantáveis , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 17(6): 617-20, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16836709

RESUMO

INTRODUCTION: Many patients with implantable cardioverter defibrillators (ICDs) have older lead systems, which are usually not replaced at the time of pulse generator replacement unless a malfunction is noted. Therefore, optimization of defibrillation with these lead systems is clinically important. The objective of this prospective study was to determine if an active abdominal pulse generator (Can) affects chronic defibrillation thresholds (DFTs) with a dual-coil, transvenous ICD lead system. METHODS AND RESULTS: The study population consisted of 39 patients who presented for routine abdominal pulse generator replacement. Each patient underwent two assessments of DFT using a step-down protocol, with the order of testing randomized. The distal right ventricular (RV) coil was the anode for the first phase of the biphasic shocks. The proximal superior vena cava (SVC) coil was the cathode for the Lead Alone configuration (RV --> SVC). For the Active Can configuration, the SVC coil and Can were connected electrically as the cathode (RV --> SVC + Can). The Active Can configuration was associated with a significant decrease in shock impedance (39.5 +/- 5.8 Omega vs. 50.0 +/- 7.6 Omega, P < 0.01) and a significant increase in peak current (8.3 +/- 2.6 A vs. 7.2 +/- 2.4 A, P < 0.01). There was no significant difference in DFT energy (9.0 +/- 4.6 J vs. 9.8 +/- 5.2 J) or leading edge voltage (319 +/- 86 V vs. 315 +/- 83 V). An adequate safety margin for defibrillation (> or =10 J) was present in all patients with both shocking configurations. CONCLUSION: DFTs are similar with the Active Can and Lead Alone configurations when a dual-coil, transvenous lead is used with a left abdominal pulse generator. Since most commercially available ICDs are only available with an active can, our data support the use of an active can device with this lead system for patients who present for routine pulse generator replacement.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Síncope/terapia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Músculos Abdominais , Idoso , Limiar Diferencial , Cardioversão Elétrica/métodos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Estudos Prospectivos
8.
Card Electrophysiol Rev ; 6(4): 466-71, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12438830

RESUMO

Management of the patient without inducible arrhythmias is dictated by the clinical setting in which the arrhythmias occur. Decisions must be based on whether the patient is being treated for symptomatic arrhythmias, or is undergoing evaluation of risk for potentially lethal arrhythmias. The management is influenced by the anatomic substrate, as well as the clinical presentation. As with all diagnostic tests, the significance of the electrophysiology study depends on the clinical context, and this type of test reflects but one mechanism for tachycardia. Finally, it is critical to remember that the results of published clinical trials can be used to guide management decisions, only when the same stimulation protocol utilized in the trials is employed, and the patient has the same characteristics as those enrolled in the trial.


Assuntos
Antiarrítmicos/uso terapêutico , Doença das Coronárias/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Parada Cardíaca/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Doença das Coronárias/mortalidade , Doença das Coronárias/terapia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia Ambulatorial , Feminino , Parada Cardíaca/tratamento farmacológico , Parada Cardíaca/prevenção & controle , Humanos , Masculino , Medição de Risco , Sensibilidade e Especificidade , Análise de Sobrevida , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/tratamento farmacológico , Taquicardia Supraventricular/mortalidade , Taquicardia Ventricular/mortalidade , Resultado do Tratamento
9.
J Physiol ; 547(Pt 2): 441-51, 2003 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12562899

RESUMO

Cardiac atrial cells lack a regular system of transverse tubules like that in cardiac ventricular cells. Nevertheless, many atrial cells do possess an irregular internal transverse-axial tubular system (TATS). To investigate the possible role of the TATS in excitation-contraction coupling in atrial myocytes, we visualized the TATS (labelled with the fluorescent indicator, Di-8-ANEPPS) simultaneously with Ca2+ transients and/or Ca2+ sparks (fluo-4). In confocal transverse linescan images of field-stimulated cells, whole-cell Ca2+ transients had two morphologies: 'U-shaped' transients and irregular or 'W-shaped' transients with a varying number of points of origin of the Ca2+ transient. About half (54 %, n =289 cells, 13 animals) of the cells had a TATS. Cells with TATS had a larger mean diameter (13.2 +/- 2.8 microm) than cells without TATS (11.7 +/- 2.0 microm) and were more common in the left atrium (n = 206 cells; left atrium: 76 with TATS, 30 without TATS; right atrium: 42 with TATS, 58 without TATS). Simultaneous measurement of Ca2+ sparks and sarcolemmal structures showed that cells without TATS had U-shaped transients that started at the cell periphery, and cells with TATS had W-shaped transients that began simultaneously at the cell periphery and the TATS. Most (82 out of 102 from 31 cells) 'spontaneous' (non-depolarized) Ca2+ sparks occurred within 1 microm of a sarcolemmal structure (cell periphery or TATS), and 33 % occurred within 1 pixel (0.125 microm). We conclude that the presence of a sarcolemmal membrane either at the cell periphery or in the TATS in close apposition to the sarcoplasmic reticulum is required for the initiation of an evoked Ca2+ transient and for spontaneous Ca2+ sparks.


Assuntos
Cálcio/metabolismo , Miócitos Cardíacos/metabolismo , Retículo Sarcoplasmático/metabolismo , Animais , Tamanho Celular , Corantes Fluorescentes , Átrios do Coração , Miócitos Cardíacos/citologia , Miócitos Cardíacos/ultraestrutura , Compostos de Piridínio , Ratos , Ratos Sprague-Dawley , Sarcolema/fisiologia , Sarcolema/ultraestrutura , Retículo Sarcoplasmático/ultraestrutura
10.
J Cardiovasc Electrophysiol ; 15(2): 170-6, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15028046

RESUMO

INTRODUCTION: In previous studies, the prognostic value of T wave alternans (TWA) was similar to that of programmed ventricular stimulation (PVS). However, presently it is unclear if TWA and PVS identify the same patients or provide complementary risk stratification information. In addition, the effects of left ventricular ejection fraction (LVEF) on the prognostic value of TWA are unknown. The aim of this study was to determine if combined assessment of TWA, LVEF, and PVS improves arrhythmia risk stratification. METHODS AND RESULTS: This was a prospective study of 144 patients with coronary artery disease and LVEF < or =40% who were referred for PVS for standard clinical indications. The endpoint was the combined incidence of death, sustained ventricular arrhythmias, and appropriate implantable cardioverter defibrillator (ICD) therapy. TWA (hazard ratio 2.2, P = 0.03) and PVS (hazard ratio 1.9, P = 0.05) both were significant predictors of endpoint events, and TWA was the only independent predictor. LVEF markedly influenced the prognostic value of TWA, which was a potent predictor of events in subjects with LVEF between 30% and 40% (event rates: TWA+ 36%, TWA- 0%, P = 0.001) but did not predict events in subjects with LVEF <30% (hazard ratio 1.1, P > 0.5). PVS successfully identified additional low-risk patients within the cohort with negative or indeterminate TWA results (hazard ratio 4.7, P = 0.015) but did not provide incremental prognostic information for TWA+ patients (hazard ratio 0.9, P > 0.5). CONCLUSION: The combined use of TWA, LVEF, and PVS is a promising new approach to arrhythmia risk stratification that permits identification of high-risk and very-low-risk patients.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Frequência Cardíaca/fisiologia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Doença Crônica , Desfibriladores Implantáveis , Intervalo Livre de Doença , Técnicas Eletrofisiológicas Cardíacas , Determinação de Ponto Final , Feminino , Seguimentos , Humanos , Masculino , Maryland , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/epidemiologia , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/terapia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 13(9): 845-50, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12380918

RESUMO

INTRODUCTION: T wave alternans (TWA) is a heart rate-dependent marker of vulnerability to ventricular arrhythmias. Atrial pacing and exercise both are used as provocative stimuli to elicit TWA. However, the prognostic value of the two testing methods has not been compared. The aim of this prospective study was to compare the prognostic value of TWA measured during bicycle exercise and atrial pacing in a large cohort of high-risk patients with ischemic heart disease and left ventricular dysfunction. METHODS AND RESULTS: This was a prospective study of 251 patients with coronary artery disease and left ventricular dysfunction who were referred for electrophysiologic studies (EPS) for standard clinical indications. Patients underwent TWA testing using bicycle ergometry (exercise TWA, n = 144) and/or atrial pacing (pacing TWA, n = 178). The primary endpoint was the combined incidence of death, sustained ventricular arrhythmias, and appropriate implantable cardioverter defibrillator therapy. The predictive value of exercise and pacing TWA for EPS results and for endpoint events was determined. Exercise and pacing TWA both were significant predictors of EPS results (odds ratios 3.0 and 2.9 respectively, P < 0.02). Kaplan-Meier survival analysis of the primary endpoint revealed that exercise TWA was a significant predictor of events (hazard ratio 2.2, P = 0.03). In contrast, pacing TWA had no prognostic value for endpoint events (hazard ratio 1.1, P = 0.8). CONCLUSION: TWA should be measured during exercise when it is used for clinical risk stratification. EPS results may not be an adequate surrogate for spontaneous events when evaluating new risk stratification tests.


Assuntos
Estimulação Cardíaca Artificial , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Eletrocardiografia , Exercício Físico/fisiologia , Síndrome do QT Longo/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Idoso , Doença Crônica , Doença da Artéria Coronariana/epidemiologia , Intervalo Livre de Doença , Técnicas Eletrofisiológicas Cardíacas , Determinação de Ponto Final , Teste de Esforço , Feminino , Seguimentos , Frequência Cardíaca/fisiologia , Humanos , Síndrome do QT Longo/fisiopatologia , Masculino , Maryland/epidemiologia , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade , Volume Sistólico/fisiologia , Resultado do Tratamento , Disfunção Ventricular Esquerda/epidemiologia
12.
J Cardiovasc Electrophysiol ; 13(8): 770-5, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12212695

RESUMO

INTRODUCTION: T wave alternans (TWA) is a promising new noninvasive marker of arrhythmia vulnerability that quantifies beat-to-beat changes in ventricular repolarization. Secondary repolarization abnormalities are common in subjects with wide QRS complexes. However, the relationship between TWA and QRS prolongation has not been evaluated. The goal of this study was to determine if QRS prolongation influences the prevalence or prognostic value of TWA. METHODS AND RESULTS: The study consisted of 108 consecutive patients with coronary artery disease and left ventricular ejection fraction < or = 40% who were referred for electrophysiologic studies. Patients underwent TWA testing using bicycle ergometry in the absence of beta-blockers or antiarrhythmic drugs. The primary endpoint was the combined incidence of death, sustained ventricular arrhythmias, and appropriate implantable cardioverter defibrillator therapy. The prognostic value of TWA was assessed in the entire cohort and in two subgroups: QRS < 120 msec (normal, n = 62) and QRS > or = 120 msec (prolonged, n = 46). TWA (hazard ratio 2.2, P = 0.03) and QRS prolongation (hazard ratio 2.2, P = 0.01) were both significant and independent predictors of arrhythmic events. QRS prolongation had no effect on the prevalence of positive TWA tests (QRS < 120 msec: 48%, QRS > or = 120 msec: 50%, P = NS). TWA was a highly significant predictor of events in patients with a normal QRS (hazard ratio 5.8, P = 0.02). In contrast, TWA was not useful for risk stratification in subjects with QRS prolongation (hazard ratio 1.1, P = 0.8). CONCLUSION: TWA is useful only for risk stratification in the absence of QRS prolongation. The presence of QRS prolongation and left ventricular ejection fraction < or = 40% may be sufficient evidence of an adverse prognosis that additional risk stratification is not useful or necessary.


Assuntos
Eletrocardiografia , Síndrome do QT Longo/diagnóstico , Adulto , Idoso , Estudos de Coortes , Ponte de Artéria Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Determinação de Ponto Final , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Síndrome do QT Longo/etiologia , Masculino , Maryland/epidemiologia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Prognóstico , Sensibilidade e Especificidade , Volume Sistólico/fisiologia , Fatores de Tempo , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA