1.
J Autoimmun ; 142: 103136, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37935063

RESUMO

K2P2.1 (TREK1), a two-pore domain potassium channel, has emerged as regulator of leukocyte transmigration into the central nervous system. In the context of skeletal muscle, immune cell infiltration constitutes the pathogenic hallmark of idiopathic inflammatory myopathies (IIMs). However, the underlying mechanisms remain to be elucidated. In this study, we investigated the role of K2P2.1 in the autoimmune response of IIMs. We detected K2P2.1 expression in primary skeletal muscle and endothelial cells of murine and human origin. We observed an increased pro-inflammatory cell response, adhesion and transmigration by pharmacological blockade or genetic deletion of K2P2.1 in vitro and in in vivo myositis mouse models. Of note, our findings were not restricted to endothelial cells as skeletal muscle cells with impaired K2P2.1 function also demonstrated a strong pro-inflammatory response. Conversely, these features were abrogated by activation of K2P2.1 and improved the disease course of a myositis mouse model. In humans, K2P2.1 expression was diminished in IIM patients compared to non-diseased controls arguing for the translatability of our findings. In summary, K2P2.1 may regulate the inflammatory response of skeletal muscle. Further research is required to understand whether K2P2.1 could serve as novel therapeutic target.


Assuntos
Células Endoteliais , Miosite , Humanos , Animais , Camundongos , Células Endoteliais/patologia , Miosite/genética , Músculo Esquelético/patologia , Leucócitos/patologia
2.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 864-871, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38454816

RESUMO

PURPOSE: To investigate the forces on a medial collateral ligament (MCL) reconstruction (MCLR) relative to the valgus alignment of the knee. METHODS: Eight fresh-frozen human cadaveric knees were subjected to dynamic valgus loading at 400 N using a custom-made kinematics rig. After resection of the superficial medial collateral ligament, a single-bundle MCLR with a hamstring tendon autograft was performed. A medial opening wedge distal femoral osteotomy was performed and fixed with an external fixator to gradually adjust the alignment in 5° increments from 0° to 10° valgus. For each degree of valgus deformity, the resulting forces acting on the MCLR were measured through a force sensor and captured in 15° increments from 0° to 60° of knee flexion. RESULTS: Irrespective of the degree of knee flexion, increasing valgus malalignment resulted in significantly increased forces acting on the MCLR compared to neutral alignment (p < 0.05). Dynamic loading at 5° valgus resulted in increased forces on the MCLR at all flexion angles ranging between 16.2 N and 18.5 N (p < 0.05 from 0° to 30°; p < 0.01 from 45° to 60°). A 10° valgus malalignment further increased the forces on the MCLR at all flexion angles ranging between 29.4 N and 40.0 N (p < 0.01 from 0° to 45°, p < 0.05 at 60°). CONCLUSION: Valgus malalignment of the knee caused increased forces acting on the reconstructed MCL. In cases of chronic medial instabilities accompanied by a valgus deformity ≥ 5°, a realigning osteotomy should be considered concomitantly to the MCLR to protect the graft and potentially reduce graft failures. LEVEL OF EVIDENCE: Level III.


Assuntos
Ligamentos Colaterais , Tendões dos Músculos Isquiotibiais , Humanos , Cadáver , Articulação do Joelho/cirurgia , Fenômenos Biomecânicos , Ligamentos Colaterais/cirurgia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38932622

RESUMO

PURPOSE: The purpose of this study was to analyse the influence of coronal lower limb alignment on collateral ligament strain. METHODS: Twelve fresh-frozen human cadaveric knees were used. Long-leg standing radiographs were obtained to assess lower limb alignment. Specimens were axially loaded in a custom-made kinematics rig with 200 and 400 N, and dynamic varus/valgus angulation was simulated in 0°, 30°, and 60° of knee flexion. The changes in varus/valgus angulation and strain within different fibre regions of the collateral ligaments were captured using a three-dimensional optical measuring system to examine the axis-dependent strain behaviour of the superficial medial collateral ligament (sMCL) and lateral collateral ligament (LCL) at intervals of 2°. RESULTS: The LCL and sMCL were exposed to the highest strain values at full extension (p < 0.001). Regardless of flexion angle and extent of axial loading, the ligament strain showed a strong and linear association with varus (all Pearson's r ≥ 0.98; p < 0.001) and valgus angulation (all Pearson's r ≥ -0.97; p < 0.01). At full extension and 400 N of axial loading, the anterior and posterior LCL fibres exceeded 4% ligament strain at 3.9° and 4.0° of varus, while the sMCL showed corresponding strain values of more than 4% at a valgus angle of 6.8°, 5.4° and 4.9° for its anterior, middle and posterior fibres, respectively. CONCLUSION: The strain within the native LCL and sMCL was linearly related to coronal lower limb alignment. Strain levels associated with potential ultrastructural damages to the ligaments of more than 4% were observed at 4° of varus and about 5° of valgus malalignment, respectively. When reconstructing the collateral ligaments, an additional realigning osteotomy should be considered in cases of chronic instability with a coronal malalignment exceeding 4°-5° to protect the graft and potentially reduce failures. LEVEL OF EVIDENCE: There is no level of evidence as this study was an experimental laboratory study.

4.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 978-986, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38431913

RESUMO

PURPOSE: This study aimed to investigate the length change patterns of the native deep medial collateral ligament (dMCL) and potential anteromedial reconstructions (AMs) that might be added to a reconstruction of the superficial MCL (sMCL) to better understand the control of anteromedial rotatory instability (AMRI). METHODS: Insertion points of the dMCL and potential AM reconstructions were marked with pins (tibial) and eyelets (femoral) in 11 cadaveric knee specimens. Length changes between the pins and eyelets were then tested using threads in a validated kinematics rig with muscle loading of the quadriceps and iliotibial tract. Between 0° and 100° knee flexion, length change pattern of the anterior, middle and posterior part of the dMCL and simulated AM reconstructions were analysed using a rotary encoder. Isometry was tested using the total strain range (TSR). RESULTS: The tibiofemoral distance of the anterior dMCL part lengthened with flexion (+12.7% at 100°), whereas the posterior part slackened with flexion (-12.9% at 100°). The middle part behaved almost isometrically (maximum length: +2.8% at 100°). Depending on the femoral position within the sMCL footprint, AM reconstructions resulted in an increase in length as the knee flexed when a more centred position was used, irrespective of the tibial attachment position. Femoral positioning in the posterior aspect of the sMCL footprint exhibited <4% length change and was slightly less tight in flexion (min TSR = 3.6 ± 1.5%), irrespective of the tibial attachment position. CONCLUSION: The length change behaviour of potential AM reconstructions in a functionally intact knee is mainly influenced by the position of the femoral attachment, with different tibial attachments having a minimal effect on length change. Surgeons performing AM reconstructions to control AMRI would be advised to choose a femoral graft position in the posterior part of the native sMCL attachment to optimise graft length change behaviour. Given the high frequency of MCL injuries, sufficient restoration of AMRI is essential in isolated and combined ligamentous knee injuries. LEVEL OF EVIDENCE: There is no level of evidence as this study was an experimental laboratory study.


Assuntos
Ligamentos Colaterais , Traumatismos do Joelho , Humanos , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Fêmur/cirurgia , Tíbia/cirurgia , Fenômenos Biomecânicos , Amplitude de Movimento Articular/fisiologia , Cadáver
5.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 881-888, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38469949

RESUMO

PURPOSE: The purpose of this study was to retrospectively analyse the pattern of injury to the medial knee structures in anterior cruciate ligament (ACL) injured patients. It was hypothesised that anteromedial injuries would be more common than posteromedial lesions. METHODS: One hundred and twenty subjects aged 18-25 years with a primary ACL injury were included. Patients were excluded if the time between injury and magnetic resonance imaging (MRI) was more than 28 days or if a knee dislocation or fracture was present. The MRIs were analysed with particular emphasis on injuries to the medial knee structures, menisci and bone bruise patterns. Injuries to the ligaments and anteromedial retinaculum (AMR) were graded according to severity, ranging from periligamentous oedema (grade I), partial fibre disruption of less or more than 50% (grade IIa or IIb) to complete tears (grade III). RESULTS: AMR injury was seen in 87 subjects (72.5%) on the coronal plane and in 88 (73.3%) on the axial plane, with grade III lesions observed in 27 (22.5%) and 29 knees (24.2%). Injuries to the superficial medial collateral ligament (sMCL), deep MCL (dMCL) and posterior oblique ligament (POL) were detected in 60 patients (50%), 93 patients (77.5%) and 38 patients (31.6%). However, grade III injuries to the POL were observed in only seven knees (5.8%). Medial meniscus injuries were associated with lesions of the sMCL and AMR (p < 0.05), while lateral meniscus injuries were significantly more common in patients with dMCL rupture (p < 0.05). CONCLUSION: Data from this study suggest that injuries to the AMR are much more common than posteromedial lesions in subjects with ACL injuries. LEVEL OF EVIDENCE: Level IV.


Assuntos
Lesões do Ligamento Cruzado Anterior , Traumatismos do Joelho , Adulto , Humanos , Adolescente , Adulto Jovem , Ligamento Cruzado Anterior , Estudos Retrospectivos , Traumatismos do Joelho/etiologia , Traumatismos do Joelho/complicações , Articulação do Joelho/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/complicações , Lesões do Ligamento Cruzado Anterior/epidemiologia , Ruptura/complicações
6.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 223-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38293720

RESUMO

PURPOSE: The aim of this consensus project was to give recommendations regarding surgical treatment of the anterior cruciate ligament (ACL) injured patient. METHODS: For this consensus process, an expert, steering and rating group was formed. In an initial online meeting, the steering group, together with the expert group, formed various key topic complexes for which multiple questions were formulated. For each key topic, a structured literature search was performed by the steering group. The results of the literature review were sent to the rating group with the option to give anonymous comments until a final consensus voting was performed. Sufficient consensus was defined as 80% agreement. RESULTS: During this consensus process, 30 topics regarding the surgical management and technique of ACL reconstruction were identified. The literature search for each key question resulted in 30 final statements. Of these 30 final statements, all achieved consensus. CONCLUSIONS: This consensus process has shown that surgical treatment of ACL injury is a complex process. Various surgical factors influence patient outcomes. The proposed treatment algorithm can be used as a decision aid for the surgeon. LEVEL OF EVIDENCE: Level V.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Algoritmos , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Consenso
7.
Acta Orthop ; 95: 290-297, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38874493

RESUMO

BACKGROUND AND PURPOSE: Recommendations regarding fragment-size-dependent screw fixation trajectory for coronal plane fractures of the posterior femoral condyles (Hoffa fractures) are lacking. The aim of this study was to compare the biomechanical properties of anteroposterior (AP) and crossed posteroanterior (PA) screw fixations across differently sized Hoffa fractures on human cadaveric femora. PATIENTS AND METHODS: 4 different sizes of lateral Hoffa fractures (n = 12 x 4) were created in 48 distal human femora according to the Letenneur classification: (i) type I, (ii) type IIa, (ii) type IIb, and (iv) type IIc. Based on bone mineral density (BMD), specimens were assigned to the 4 fracture clusters and each cluster was further assigned to fixation with either AP (n = 6) or crossed PA screws (n = 6) to ensure homogeneity of BMD values and comparability between the different test conditions. All specimens were biomechanically tested under progressively increasing cyclic loading until failure, capturing the interfragmentary movements via motion tracking. RESULTS: For Letenneur type I fractures, kilocycles to failure (mean difference [∆] 2.1, 95% confidence interval [CI] -1.3 to 5.5), failure load (∆ 105 N, CI -83 to 293), axial displacement (∆ 0.3 mm, CI -0.8 to 1.3), and fragment rotation (∆ 0.5°, CI -3.2 to 2.1) over 5.0 kilocycles did not differ significantly between the 2 screw trajectories. For each separate subtype of Letenneur type II fractures, fixation with crossed PA screws resulted in significantly higher kilocycles to failure (∆ 6.7, CI 3.3-10.1 to ∆ 8.9, CI 5.5-12.3) and failure load (∆ 275 N, CI 87-463 to ∆ 438, CI 250-626), as well as, less axial displacement from 3.0 kilocycles onwards (∆ 0.4°, CI 0.03-0.7 to ∆ 0.5°, CI 0.01-0.9) compared with AP screw fixation. CONCLUSION: Irrespective of the size of Letenneur type II fractures, crossed PA screw fixation provided greater biomechanical stability than AP-configured screws, whereas both screw fixation techniques demonstrated comparable biomechanical competence for Letenneur type I fractures. Fragment-size-dependent treatment strategies might be helpful to determine not only the screw configuration but also the surgical approach.


Assuntos
Parafusos Ósseos , Cadáver , Fraturas do Fêmur , Fixação Interna de Fraturas , Humanos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fenômenos Biomecânicos , Fraturas do Fêmur/cirurgia , Idoso , Feminino , Masculino , Densidade Óssea , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Estudos de Coortes
8.
Knee Surg Sports Traumatol Arthrosc ; 31(10): 4151-4161, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37154909

RESUMO

PURPOSE: The aim of this biomechanical cadaver study was to evaluate the effects of high-grade posterolateral tibia plateau fractures on the kinematics of anterior cruciate ligament (ACL)-deficient joints; it was hypothesized that, owing to the loss of the integrity of the osseous support of the posterior horn of the lateral meniscus (PHLM), these fractures would influence the biomechanical function of the lateral meniscus (LM) and consequently lead to an increase in anterior translational and anterolateral rotational (ALR) instability. METHODS: Eight fresh-frozen cadaveric knees were tested using a six-degree-of-freedom robotic setup (KR 125, KUKA Robotics, Germany) with an attached optical tracking system (Optotrack Certus Motion Capture, Northern Digital, Canada). After the passive path from 0 to 90° was established, a simulated Lachman test and pivot-shift test as well as external rotation (ER) and internal rotation (IR) were applied at 0°, 30°, 60° and 90° of flexion under constant 200 N axial loading. All of the parameters were initially tested in the intact and ACL-deficient states, followed by two different types of posterolateral impression fractures. The dislocation height was 10 mm, and the width was 15 mm in both groups. The intraarticular depth of the fracture corresponded to half of the width of the posterior horn of the lateral meniscus in the first group (Bankart 1) and 100% of the meniscus width in the second group (Bankart 2). RESULTS: There was a significant decrease in knee stability after both types of posterolateral tibial plateau fractures in the ACL-deficient specimens, with increased anterior translation in the simulated Lachman test at 0° and 30° of knee flexion (p = 0.012). The same effect was seen with regard to the simulated pivot-shift test and IR of the tibia (p = 0.0002). In the ER and posterior drawer tests, ACL deficiency and concomitant fractures did not influence knee kinematics (n.s.). CONCLUSION: This study demonstrates that high-grade impression fractures of the posterolateral aspect of the tibial plateau increase the instability of ACL-deficient knees and result in an increase in translational and anterolateral rotational instability.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Instabilidade Articular , Humanos , Ligamento Cruzado Anterior/cirurgia , Tíbia/cirurgia , Lesões do Ligamento Cruzado Anterior/complicações , Lesões do Ligamento Cruzado Anterior/cirurgia , Instabilidade Articular/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos
9.
Arthroscopy ; 38(3): 860-869, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34052378

RESUMO

PURPOSE: The goal of the present study was to evaluate a potential tunnel convergence in combined anterior cruciate ligament (ACL) reconstruction using the anteromedial portal technique and lateral extra-articular tenodesis (LET). METHODS: Ten fresh frozen femora were dissected and a K-wires were inserted into the middle of the ACL stump, according to an ACL reconstruction at 110° and 140° knee flexion. ACL reconstruction at 120° and 130° was simulated. Seven K-wires with different femoral insertion sites and angulations were drilled into the lateral femoral condyle relative to the lateral epicondyle (E3: 8 mm proximal and 4 mm posterior; E1: 5 mm proximal and 5 mm anterior and E2: over-the-top position). Tunnel conflict rate was evaluated using a measuring arm and a metrology software. RESULTS: Drilling the femoral ACL tunnel in low knee flexion (110°-120°) significantly (P < .001) reduced the tunnel conflict rate compared to the ACL drilled in high knee flexion (130°-140°). Changing the insertion point from proximal and posterior (E3) to proximal and anterior (E1) showed a reduced tunnel conflict rate from 40 ± 21.2% to 15 ± 26% and no tunnel conflict for an ACL drilled at 110°-130° knee flexion. CONCLUSION: A possible tunnel conflict in simultaneous ACL reconstruction using the AMP technique and LET was dependent on ACL knee flexion angle, LET insertion site, and angulation. This posed the dilemma that no generally applicable LET configuration could be recommended to avoid a tunnel conflict. However, it appears that an insertion point located proximal and anterior to the lateral epicondyle results in less tunnel conflicts than an insertion point located proximal and posterior. CLINICAL RELEVANCE: An insertion point located proximal and anterior to the lateral epicondyle with a 30° proximal and 30° anterior angulation could reliably avoid a tunnel conflict when the ACL was drilled between 110 and 130° using a low anteromedial portal.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Cadáver , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia
10.
Knee Surg Sports Traumatol Arthrosc ; 29(11): 3800-3808, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33454831

RESUMO

PURPOSE: The purpose of this study was to examine the length change patterns of the native medial structures of the knee and determine the effect on graft length change patterns for different tibial and femoral attachment points for previously described medial reconstructions. METHODS: Eight cadaveric knee specimens were prepared by removing the skin and subcutaneous fat. The sartorius fascia was divided to allow clear identification of the medial ligamentous structures. Knees were then mounted in a custom-made rig and the quadriceps muscle and the iliotibial tract were loaded, using cables and hanging weights. Threads were mounted between tibial and femoral pins positioned in the anterior, middle, and posterior parts of the attachment sites of the native superficial medial collateral ligament (sMCL) and posterior oblique ligament (POL). Pins were also placed at the attachment sites relating to two commonly used medial reconstructions (Bosworth/Lind and LaPrade). Length changes between the tibiofemoral pin combinations were measured using a rotary encoder as the knee was flexed through an arc of 0-120°. RESULTS: With knee flexion, the anterior fibres of the sMCL tightened (increased in length 7.4% ± 2.9%) whilst the posterior fibres slackened (decreased in length 8.3% ± 3.1%). All fibre regions of the POL displayed a uniform lengthening of approximately 25% between 0 and 120° knee flexion. The most isometric tibiofemoral combination was between pins placed representing the middle fibres of the sMCL (Length change = 5.4% ± 2.1% with knee flexion). The simulated sMCL reconstruction that produced the least length change was the Lind/Bosworth reconstruction with the tibial attachment at the insertion of the semitendinosus and the femoral attachment in the posterior part of the native sMCL attachment side (5.4 ± 2.2%). This appeared more isometric than using the attachment positions described for the LaPrade reconstruction (10.0 ± 4.8%). CONCLUSION: The complex behaviour of the native MCL could not be imitated by a single point-to-point combination and surgeons should be aware that small changes in the femoral MCL graft attachment position will significantly effect graft length change patterns. Reconstructing the sMCL with a semitendinosus autograft, left attached distally to its tibial insertion, would appear to have a minimal effect on length change compared to detaching it and using the native tibial attachment site. A POL graft must always be tensioned near extension to avoid capturing the knee or graft failure.


Assuntos
Ligamento Colateral Médio do Joelho , Fenômenos Biomecânicos , Cadáver , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Ligamentos Articulares , Ligamento Colateral Médio do Joelho/cirurgia , Tíbia/cirurgia
11.
Knee Surg Sports Traumatol Arthrosc ; 29(2): 405-416, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32277264

RESUMO

PURPOSE: The purpose of the present study was to determine how the medial structures and ACL contribute to restraining anteromedial instability of the knee. METHODS: Twenty-eight paired, fresh-frozen human cadaveric knees were tested in a six-degree of freedom robotic setup. After sequentially cutting the dMCL, sMCL, POL and ACL in four different cutting orders, the following simulated clinical laxity tests were applied at 0°, 30°, 60° and 90° of knee flexion: 4 Nm external tibial rotation (ER), 4 Nm internal tibial rotation (IR), 8 Nm valgus rotation (VR) and anteromedial rotation (AMR)-combined 89 N anterior tibial translation and 4 Nm ER. Knee kinematics were recorded in the intact state and after each cut using an optical tracking system. Differences in medial compartment translation (AMT) and tibial rotation (AMR, ER, IR, VR) from the intact state were then analyzed. RESULTS: The sMCL was the most important restraint to AMR, ER and VR at all flexion angles. Release of the proximal tibial attachment of the sMCL caused no significant increase in laxity if the distal sMCL attachment remained intact. The dMCL was a minor restraint to AMT and ER. The POL controlled IR and was a minor restraint to AMT and ER near extension. The ACL contributed with the sMCL in restraining AMT and was a secondary restraint to ER and VR in the MCL deficient knee. CONCLUSION: The sMCL appears to be the most important restraint to anteromedial instability; the dMCL and POL play more minor roles. Based on the present data a new classification of anteromedial instability is proposed, which may support clinical examination and treatment decision. In higher grades of anteromedial instability an injury to the sMCL should be suspected and addressed if treated surgically.


Assuntos
Ligamento Cruzado Anterior/fisiopatologia , Instabilidade Articular/fisiopatologia , Articulação do Joelho/fisiopatologia , Ligamento Colateral Médio do Joelho/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Lesões do Ligamento Cruzado Anterior , Fenômenos Biomecânicos , Cadáver , Ligamentos Colaterais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exame Físico , Amplitude de Movimento Articular , Robótica , Rotação , Tíbia/fisiopatologia
12.
Unfallchirurg ; 124(5): 407-411, 2021 May.
Artigo em Alemão | MEDLINE | ID: mdl-33067695

RESUMO

The case of a 56-year-old male patient with locking of the knee in extension without trauma is presented. Patient history, clinical examination and radiographs confirmed a superior dislocation of the patella. Closed reduction led to full weight bearing with free range of motion without further complaints. Knowledge of this uncommon cause of a locked knee joint leads to immediate treatment avoiding complex imaging modalities, such as computed tomography (CT) or magnetic resonance imaging (MRI). No further treatment was necessary in the majority of the cases published in the literature.


Assuntos
Artropatias , Luxações Articulares , Luxação Patelar , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Patela , Luxação Patelar/diagnóstico por imagem , Luxação Patelar/cirurgia , Amplitude de Movimento Articular
13.
Arthroscopy ; 35(11): 3069-3076, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31405619

RESUMO

PURPOSE: To evaluate the effects of different stitching methods and suture diameters on the graft fixation of soft tissue human quadriceps tendon grafts for anterior cruciate ligament (ACL) reconstruction. METHODS: The Krackow locking stitch (K), whipstitch (W), and baseball stitch (B) were combined with either a 2× no. 2 (#2) or a 1× no. 5 (#5) braided composite suture for graft fixation of 36 human quadriceps tendons in 6 groups. Biomechanical testing was performed using a cyclic protocol with loads between 0 and 100 N. The maximum load until failure, cyclic elongation, and failure mode were recorded. RESULTS: The highest mean maximum load to failure was observed in the 2 Krackow stitch groups. The K#2 group had significantly higher load to failure values compared with those of the W#2 and B#2 groups (K#2, 553 ± 82 N vs W#2, 392 ± 107 N, P = .0349; K#2 vs B#2 366 ± 118 N, P = .0129). The mean cyclic elongation was lowest in the Krackow groups (K#2, 10.59 ± 2.63 mm; K#5, 13.66 ± 2.3 mm). The regular failure mode was the rupture of the suture for the Krackow stitch (8 of 12) and suture pullout for the whipstitch (11 of 12) and baseball stitch groups (12 of 12). CONCLUSIONS: The double Krackow stitch with no. 2 braided composite suture exhibits a high maximum load to failure combined with a low amount of elongation in a biomechanical study for human quadriceps tendon soft tissue graft fixation. Unlike the whipstitch and the baseball stitch, it can solidly prevent suture pullout. CLINICAL RELEVANCE: A safe soft tissue graft fixation technique is especially important for quadriceps tendon grafts with their laminar anatomical structure and physiologically varying diameter. Unlike other grafts for ACL replacement, it fully relies on the soft tissue suture fixation to resist the pullout force.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Técnicas de Sutura/normas , Suturas , Tendões/fisiopatologia , Tendões/transplante , Fixação de Tecidos/normas , Idoso , Ligamento Cruzado Anterior/fisiopatologia , Fenômenos Biomecânicos , Humanos , Masculino , Guias de Prática Clínica como Assunto , Músculo Quadríceps , Técnicas de Sutura/instrumentação
14.
Unfallchirurg ; 122(12): 977-991, 2019 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-31728556

RESUMO

The clinical examination of the knee joint represents a great challenge as well as a great opportunity. In particular, ligamentous injuries are understood better despite their complexity and thus treated in a more differentiated way. A purely radiologically based diagnosis is only possible to a limited extent, especially for chronic injuries. Therefore, complex ligament injuries can be diagnosed with the aid of a differentiated clinical examination. This article gives an overview of the most important examination techniques of the knee joint, with which the decisive analysis of acute or chronic injuries and overuse syndromes of the knee can be carried out. Particularly in the field of ligament instability, this article provides a practical guide for the differentiated examination of complex rotational instability of the knee joint. In addition, the most important patellar and meniscal examination techniques are described.


Assuntos
Traumatismos do Joelho , Lesões do Menisco Tibial , Humanos , Traumatismos do Joelho/diagnóstico , Articulação do Joelho , Ligamentos Articulares , Exame Físico , Lesões do Menisco Tibial/diagnóstico
15.
Knee Surg Sports Traumatol Arthrosc ; 26(5): 1384-1391, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29063153

RESUMO

PURPOSE: Femoral tunnel placement is essential for good outcome in anterior cruciate ligament (ACL) reconstruction. In the past, several attempts have been made to optimize femoral tunnel placement. It was observed that the posterior horn of the lateral meniscus was always located directly below to the desired femoral ACL tunnel position, when the knee was brought to deep flexion (> 120°). The goal of the present study was to verify the hypothesis that the posterior horn of the lateral meniscus can be used as a landmark for femoral tunnel placement. METHODS: Out of a consecutive series of ACL reconstructions done by a single surgeon, 55 lateral radiographs were evaluated according to the quadrant method by Bernard and Hertel. Additionally, on anterior-posterior radiographs the femoral tunnel angle was determined. RESULTS: In the present case series the posterior horn of the lateral meniscus could be identified and used as a landmark for femoral tunnel placement in all cases. The mean tunnel depth was 24 ± 5.1% and the mean tunnel height was 31.3 ± 5.7%. The mean femoral tunnel angle was 41 ± 4.9° using the anatomical axis as a reference. Compared to previous cadaver studies the data of the present study were within their anatomical range of the native ACL insertion site. CONCLUSION: The suggested technique using the posterior horn of the lateral meniscus as a landmark for femoral tunnel placement showed reproducible results and matches the native ACL insertion site compared to previous cadaveric studies. In particular, non-experienced ACL surgeons will benefit from this apparent landmark and the corresponding easy-to-use ACL reconstruction method. LEVEL OF EVIDENCE: IV.


Assuntos
Pontos de Referência Anatômicos , Reconstrução do Ligamento Cruzado Anterior/métodos , Fêmur/cirurgia , Meniscos Tibiais/anatomia & histologia , Adolescente , Adulto , Feminino , Fêmur/diagnóstico por imagem , Humanos , Masculino , Meniscos Tibiais/diagnóstico por imagem , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
16.
Knee Surg Sports Traumatol Arthrosc ; 24(8): 2646-55, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26519188

RESUMO

PURPOSE: The aim of this study was to quantify the contributions of medial soft tissues to stability following cruciate-retaining (CR) or posterior-stabilised (PS) total knee arthroplasty (TKA). METHODS: Using a robotic system, eight cadaveric knees were subjected to ±90-N anterior-posterior force, ±5-Nm internal-external and ±8-Nm varus-valgus torques at various flexion angles. The knees were tested intact and then with CR and PS implants, and successive cuts of the deep and superficial medial collateral ligaments (dMCL, sMCL) and posteromedial capsule (PMC) quantified the percentage contributions of each structure to restraining the applied loads. RESULTS: In implanted knees, the sMCL restrained valgus rotation (62 % across flexion angles), anterior-posterior drawer (24 and 10 %, respectively) and internal-external rotation (22 and 37 %). Changing from CR TKA to PS TKA increased the load on the sMCL when resisting valgus loads. The dMCL restrained 11 % of external and 13 % of valgus rotations, and the PMC was significant at low flexion angles. CONCLUSIONS: This work has shown that medial release in the varus knee should be minimised, as it may inadvertently result in a combined laxity pattern. There is increasing interest in preserving constitutional varus in TKA, and this work argues for preservation of the sMCL to afford the surgeon consistent restraint and maintain a balanced knee for the patient.


Assuntos
Artroplastia do Joelho/efeitos adversos , Instabilidade Articular/fisiopatologia , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Ligamento Colateral Médio do Joelho/fisiopatologia , Ligamento Colateral Médio do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/instrumentação , Cadáver , Feminino , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Amplitude de Movimento Articular , Rotação , Torque
17.
Unfallchirurgie (Heidelb) ; 127(1): 18-26, 2024 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-37848564

RESUMO

Different medial structures are responsible for restraining valgus rotation, external rotation, and anteromedial rotation. When injured this can result in various degrees of isolated and combined instabilities. In contrast to earlier speculation, the posterior oblique ligament (POL) is no longer considered to be the main stabilizer of anteromedial rotatory instability (AMRI). Acute proximal medial ruptures are typically managed conservatively with very good clinical results. Conversely, acute distal ruptures usually require a surgical intervention. Chronic instabilities mostly occur in combination with instabilities of the anterior cruciate ligament (ACL). The clinical examination is a particularly important component in these cases to determine the indications for surgery for an additional medial reconstruction. In cases of severe medial and anteromedial instabilities, surgical treatment should be considered. Biomechanically, a combined medial and anteromedial reconstruction appears to be superior to other reconstruction methods; however, there is currently a lack of clinical studies to confirm this biomechanical advantage.


Assuntos
Lesões do Ligamento Cruzado Anterior , Instabilidade Articular , Humanos , Lesões do Ligamento Cruzado Anterior/cirurgia , Amplitude de Movimento Articular , Instabilidade Articular/etiologia , Fenômenos Biomecânicos , Articulação do Joelho/diagnóstico por imagem , Ruptura
18.
Orthop J Sports Med ; 12(4): 23259671241240375, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38576875

RESUMO

Background: Concerns regarding the primary stability of early adjustable loop button (ALB) devices for cortical fixation of tendon grafts in anterior cruciate ligament reconstruction (ACLR) have led to the development of new implant designs. Purpose: To evaluate biomechanical stability of recent ALB implants in comparison with a continuous loop button (CLB) device. Study Design: Controlled laboratory study. Methods: ACLR was performed in a porcine model (n = 40) using 2-strand porcine flexor tendons with a diameter of 8 mm. Three ALB devices (Infinity Button [ALB1 group]; Tightrope II RT [ALB2 group]; A-TACK [ALB3 group]) and 1 CLB device (FlippTack with polyethylene suture) were used for cortical tendon graft fixation. Cyclic loading (1000 cycles up to 250 N) with complete unloading were applied to the free end of the tendon graft using a uniaxial testing machine, followed by load to failure. Elongation, stiffness, yield load, and ultimate failure load were recorded and compared between the groups using a Kruskal-Wallis test with post hoc Dunn correction. Results: Elongation after 1000 cycles at 250 N was similar between groups (ALB1, 4.5 ± 0.7 mm; ALB2, 4.8 ± 0.8 mm; ALB3, 4.5 ± 0.6 mm; CLB, 4.5 ± 0.8 mm), as was load to failure (ALB1, 838 ± 109 N; ALB2, 930 ± 89 N; ALB3, 809 ± 103 N; CLB, 842 ± 80 N). Stiffness was significantly higher in the ALB1 group compared with the CLB group (262.3 ± 21.6 vs 229.3 ± 15.1 N/mm; P < .05). No significant difference was found between the 4 groups regarding yield load. Constructs failed either by rupture of the loop, breakage of the button, or rupture of the tendon. Conclusion: The tested third-generation ALB devices for cortical fixation in ACLR withstood cyclic loading with complete unloading without significant differences to a CLB device. Clinical Relevance: The third-generation ALB devices tested in the present study provided biomechanical stability comparable with that of a CLB device. Furthermore, ultimate failure loads of all tested implants exceeded the loads expected to occur in the postoperative period after ACLR.

19.
Am J Sports Med ; 52(4): 928-935, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38343294

RESUMO

BACKGROUND: Conflicting evidence has been reported regarding the biomechanical relevance of ramp lesions (RLs) on knee kinematics. Furthermore, the influence of the defect size of the RLs on anterior tibial translation (ATT) and external rotation (ER) is currently unknown. PURPOSE: To evaluate the influence of RL defect size on knee kinematics in anterior cruciate ligament (ACL) deficiency and after simulated ACL reconstruction (sACLR). STUDY DESIGN: Controlled laboratory study. METHODS: Eight cadaveric knee specimens were tested in a 6 degrees of freedom robotic test setup. Force-controlled clinical laxity tests were performed with 200 N of axial compression in 0°, 30°, 60°, and 90° of flexion: 5 N·m internal rotation (IR)/ER torque, 134 N ATT force, and an anteromedial drawer test consisting of 134 N ATT force under 5 N·m ER torque. After determining the native knee kinematics, the ACL was cut at the tibial insertion, followed by a transosseous refixation to simulate a surgical repair or reconstruction (simulated ACL reconstruction; sACLR). An RL was sequentially created with a length of 1, 2, and 3 cm. Each state of the RL was evaluated in the ACL-deficient state and after sACLR. RESULTS: In the ACL-deficient state, only an RL of 3 cm length resulted in a significant increase of ATT in 30° of flexion (mean difference 0.73 mm; 95% CI, 0.36-1.1 mm). After sACLR, an RL had no significant effect. When looking at ER, an RL significantly increased ER in full extension in the ACL-deficient state in 2 cm (mean difference 0.9°; 95% CI, 0.08°-1.74°) and 3 cm length (mean difference 1.9°; 95% CI, 0.57-3.25). Furthermore, a 3-cm RL significantly increased IR in 0° of flexion in the ACL-deficient state (mean difference 1.9°; 95% CI, 0.2°-3.6°). No effect of ramp lesions on rotation was found after sACLR. CONCLUSION: RLs result in a small increase in ATT, ER, and IR in ACL-deficient knees at early flexion angles, but not after sACLR. CLINICAL RELEVANCE: Small RLs did not change time-zero knee kinematics and may, therefore, be left untreated, especially when the ACL is reconstructed.


Assuntos
Lesões do Ligamento Cruzado Anterior , Instabilidade Articular , Procedimentos Cirúrgicos Robóticos , Humanos , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Cadáver , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos
20.
Orthop J Sports Med ; 12(3): 23259671241236783, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38532766

RESUMO

Background: Bone staples have been shown previously to be a viable modality for cortical tendon graft fixation in ligament knee surgery. However, soft tissue reactions have been reported, making implant removal necessary. Magnesium alloys are a promising material for biodegradable orthopaedic implants, with mechanical properties closely resembling those of human bone. Purpose: To compare the primary stability of a biodegradable bone staple prototype made from magnesium to bone staples made from metal in the cortical fixation of tendon grafts during knee surgery. Study Design: Controlled laboratory study. Methods: Primary stability of peripheral tendon graft fixation was assessed in a porcine model of medial collateral ligament reconstruction. Two commercially available metal bone staples (Richards fixation staple with spikes [Me1] and spiked ligament staple [Me2]) were compared with a magnesium bone staple prototype for soft tissue fixation. Primary stability was assessed using a uniaxial materials testing machine. Cyclic loading at 50 and 100 N was applied for 500 cycles each, followed by load-to-failure testing. Results: After 500 cycles at 50 N, elongation was 1.5 ± 0.5 mm in the Me1 group, 1.9 ± 0.5 mm in the Me2 group, and 1.8 ± 0.4 mm in the magnesium group. After 1000 cycles of loading (500 cycles at 50 N and 500 at 100 N), elongation was 3.6 ± 0.9 mm in the Me1 group, 3.5 ± 0.6 mm in the Me2 group, and 4.1 ± 1.0 mm in the magnesium group. No significant differences regarding elongation were found between the groups. Load to failure was 352 ± 115 N in the Me1 group, 373 ± 77 N in the Me2 group, and 449 ± 92 N in the magnesium group, with no significant difference between the groups. Conclusion: In this study, the magnesium bone staples provided appropriate time-zero biomechanical primary stability in comparison with metal bone staples and may therefore be a feasible alternative for cortical fixation of tendon grafts in knee surgery. Clinical Relevance: The biodegradability of magnesium bone staples would eliminate the need for later implant removal.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA