Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 185
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(4): 785-793, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383981

RESUMO

INTRODUCTION: Wearable cardioverter defibrillator (WCD) is utilized in patients with assumed but not yet confirmed risk for sudden cardiac death (SCD). Many of these patients also present with atrial fibrillation (AF). However, the rate of WCD-detected ventricular or atrial arrhythmia events in this specific high-risk cohort is not well understood. METHODS: In WEARIT-II, the cumulative probability of any sustained or nonsustained VT/VF (WCD-treated and nontreated), and atrial/supraventricular arrhythmias during WCD use was assessed using the Kaplan-Meier method by prior AF, with comparisons by the log-rank test. The incidence of ventricular and atrial arrhythmia events were expressed as events per 100 patient-years, and were analyzed by prior AF using negative binomial regression. RESULTS: WEARIT-II enrolled 2000 patients, 557 (28%) of whom had AF before enrollment. Cumulative probability of any sustained or nonsustained WCD-detected VT/VF during WCD use was significantly higher among patients with a history of AF than without AF (6% vs. 3%, p = .001). Similarly, the recurrent rate of any sustained or nonsustained VT/VF was significantly higher in patients with prior AF versus no prior AF (131.5 events per 100 patient-years vs. 22.7 events per 100 patient-years, p = .001). Patients with prior AF also had a significantly higher burden of any WCD-detected atrial arrhythmias/SVT/inappropriate arrhythmias therapy (183.2 events per 100 patient-years vs. 74.8 events per 100 patient-years, p < .001). CONCLUSION: Our results demonstrate that patients with a history of AF wearing the WCD for risk assessment have a higher incidence of ventricular arrhythmias that may facilitate the decision making for ICD implantation.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cardioversão Elétrica/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Medição de Risco , Sistema de Registros , Desfibriladores Implantáveis/efeitos adversos
2.
Eur Heart J ; 44(40): 4259-4269, 2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37632437

RESUMO

BACKGROUND AND AIMS: De novo implanted cardiac resynchronization therapy with defibrillator (CRT-D) reduces the risk of morbidity and mortality in patients with left bundle branch block, heart failure and reduced ejection fraction (HFrEF). However, among HFrEF patients with right ventricular pacing (RVP), the efficacy of CRT-D upgrade is uncertain. METHODS: In this multicentre, randomized, controlled trial, 360 symptomatic (New York Heart Association Classes II-IVa) HFrEF patients with a pacemaker or implantable cardioverter defibrillator (ICD), high RVP burden ≥ 20%, and a wide paced QRS complex duration ≥ 150 ms were randomly assigned to receive CRT-D upgrade (n = 215) or ICD (n = 145) in a 3:2 ratio. The primary outcome was the composite of all-cause mortality, heart failure hospitalization, or <15% reduction of left ventricular end-systolic volume assessed at 12 months. Secondary outcomes included all-cause mortality or heart failure hospitalization. RESULTS: Over a median follow-up of 12.4 months, the primary outcome occurred in 58/179 (32.4%) in the CRT-D arm vs. 101/128 (78.9%) in the ICD arm (odds ratio 0.11; 95% confidence interval 0.06-0.19; P < .001). All-cause mortality or heart failure hospitalization occurred in 22/215 (10%) in the CRT-D arm vs. 46/145 (32%) in the ICD arm (hazard ratio 0.27; 95% confidence interval 0.16-0.47; P < .001). The incidence of procedure- or device-related complications was similar between the two arms [CRT-D group 25/211 (12.3%) vs. ICD group 11/142 (7.8%)]. CONCLUSIONS: In pacemaker or ICD patients with significant RVP burden and reduced ejection fraction, upgrade to CRT-D compared with ICD therapy reduced the combined risk of all-cause mortality, heart failure hospitalization, or absence of reverse remodelling.

3.
Eur Heart J ; 42(17): 1676-1684, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33417692

RESUMO

AIMS: The benefit of prophylactic implantable cardioverter-defibrillator (ICD) is not uniform due to differences in the risk of life-threatening ventricular tachycardia (VT)/ventricular fibrillation (VF) and non-arrhythmic mortality. We aimed to develop an ICD benefit prediction score that integrates the competing risks. METHODS AND RESULTS: The study population comprised all 4531 patients enrolled in the MADIT trials. Best-subsets Fine and Gray regression analysis was used to develop prognostic models for VT (≥200 b.p.m.)/VF vs. non-arrhythmic mortality (defined as death without prior sustained VT/VF). Eight predictors of VT/VF (male, age < 75 years, prior non-sustained VT, heart rate > 75 b.p.m., systolic blood pressure < 140 mmHg, ejection fraction ≤ 25%, myocardial infarction, and atrialarrhythmia) and 7 predictors of non-arrhythmic mortality (age ≥ 75 years, diabetes mellitus, body mass index < 23 kg/m2, ejection fraction ≤ 25%, New York Heart Association ≥II, ICD vs. cardiac resynchronization therapy with defibrillator, and atrial arrhythmia) were identified. The two scores were combined to create three MADIT-ICD benefit groups. In the highest benefit group, the 3-year predicted risk of VT/VF was three-fold higher than the risk of non-arrhythmic mortality (20% vs. 7%, P < 0.001). In the intermediate benefit group, the difference in the corresponding predicted risks was attenuated (15% vs. 9%, P < 0.01). In the lowest benefit group, the 3-year predicted risk of VT/VF was similar to the risk of non-arrhythmic mortality (11% vs. 12%, P = 0.41). A personalized ICD benefit score was developed based on the distribution of the two competing risks scores in the study population (https://is.gd/madit). Internal and external validation confirmed model stability. CONCLUSIONS: We propose the novel MADIT-ICD benefit score that predicts the likelihood of prophylactic ICD benefit through personalized assessment of the risk of VT/VF weighed against the risk of non-arrhythmic mortality.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Taquicardia Ventricular , Idoso , Arritmias Cardíacas/terapia , Humanos , Masculino , Fatores de Risco , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia
4.
Europace ; 21(12): 1843-1850, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31647531

RESUMO

AIMS: There are limited data regarding factors that identify implantable cardioverter-defibrillator (ICD) patients who will experience either ventricular tachyarrhythmic (VTA) or non-arrhythmic (NA) mortality, and the commonly used clinical classification of sudden cardiac death (SCD) vs. non-sudden cardiac death (NSCD) may not be accurate enough. We aimed to correlate clinical adjudication of mortality events to device interrogation data and to identify risk factors for VTA mortality in Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II). METHODS AND RESULTS: Of the 746 patients who received an ICD in MADIT-II, 44 died from cardiac causes and had available interrogation data at the time of death. Sudden cardiac death vs. NSCD was defined by an adjudication committee. Ventricular tachyarrhythmic and NA arrhythmic deaths were categorized by the presence or absence of ventricular tachycardia or fibrillation (VT/VF) during the terminal event. Mode of death was found to be inaccurate when validated by device interrogation for VTA events: 50% patients adjudicated as SCD did not have a VTA event at the time of death; and 25% of adjudicated NSCD were found to have VT/VF during the mortality event. Multivariate analysis showed that factors independently associated with VTA mortality included: VT/VF >72 h prior to the mortality event [hazard ratio (HR) 8.0; P < 0.001], hospitalization for heart failure (HR 6.7; P = 0.001), and a history of hypertension (HR 4; P = 0.04). CONCLUSION: Current classification of SCD vs. NSCD fails to identify VTA events at the time of death in a significant proportion of patients, and simple clinical parameters can be used to identify ICD recipients with increased risk for VTA mortality.


Assuntos
Bradicardia/mortalidade , Desfibriladores Implantáveis , Parada Cardíaca/mortalidade , Taquicardia Ventricular/mortalidade , Fibrilação Ventricular/mortalidade , Idoso , Causas de Morte , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/estatística & dados numéricos , Feminino , Humanos , Masculino , Mortalidade , Modelos de Riscos Proporcionais
5.
Europace ; 20(FI2): f225-f232, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29905788

RESUMO

Aims: Data on outcomes in patients using the wearable cardioverter-defibrillator (WCD) > 90 days are limited. We aimed to analyse the clinical course of patients with WCD use ≤90 days vs. WCD use >90 days. Methods and results: We assessed arrhythmia events during WCD use, and ejection fraction (EF) improvement/implantable cardioverter-defibrillator (ICD) implantation at the end of WCD use in patients with WCD use ≤90 days vs. WCD use >90 days enrolled in the WEARIT-II registry, further assessed by disease aetiology (ischaemic vs. non-ischaemic vs. congenital/inherited heart disease). There were 981 (49%) patients with WCD use >90 days, and 1019 patients with WCD use ≤90 days (median 120 vs. 55 days). There was a lower incidence of sustained ventricular tachycardia/ventricular fibrillation (VT/VF) events (11 vs. 50 events per 100 patient-years, P < 0.001), WCD treated VT/VF events (1 vs. 8 events per 100 patient-years, P < 0.001), and non-sustained VT events (21 vs. 51 events per 100 patient-years, P = 0.008) with WCD use >90 vs. WCD use ≤90 days. Non-ischaemic cardiomyopathy patients presented with similar rates of sustained VT/VF events during WCD use >90 vs. ≤90 days (13.4 vs. 13.7 events per 100 patient-years, P = 0.314), while most of these events terminated spontaneously. One-third of the patients with extended WCD use further improved their EF and they were not implanted with an ICD, with similar rates among ischaemic and non-ischaemic patients. Conclusions: In WEARIT-II, patients with extended WCD use >90 days remain at risk for ventricular arrhythmia events. One-third of the patients with WCD use >90 days further improved their EF, avoiding the need to consider ICD implantation.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Dispositivos Eletrônicos Vestíveis , Idoso , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/complicações , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade
6.
Pacing Clin Electrophysiol ; 41(10): 1307-1313, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29992590

RESUMO

BACKGROUND: The WEARIT-II Registry demonstrated efficacy and safety of the wearable cardioverter defibrillator (WCD) for at-risk cardiac patients. However, 1-year outcomes in this population have not been reported. METHODS: The WEARIT-II Registry enrolled 2,000 U.S. patients prescribed the WCD. One-year mortality data from start of WCD use were prospectively collected for 1,846 patients (93%). Outcome data were analyzed by disease etiology and implantable cardioverter defibrillator (ICD) implantation following WCD use. RESULTS: During 12 months of follow-up, 73 patients died (4%). Kaplan-Meier survival analysis showed differences in all-cause mortality from WCD prescription between patients with ischemic versus nonischemic cardiomyopathy versus congenital/inherited heart disease (4% vs 3% vs 7%, P = 0.013). Patients with ventricular arrhythmia events during WCD use had a higher 1-year mortality (10% vs 3%, P = 0.042). Renal disease, increasing age, prior syncope, and nonbeta-blocker use predicted mortality. One-year mortality was similar in patients who did versus did not receive an ICD following WCD use in ischemic (3% vs 4%, P = 0.470) and nonischemic cardiomyopathy (3% vs 3%, P = 0.892). Patients with congenital/inherited heart disease with no implanted ICD had a trend toward a higher rate of mortality than those who received an ICD (8% vs 3%, P = 0.082). Multivariate models confirmed these findings. CONCLUSION: One-year follow-up from the WEARIT-II Registry shows an overall good survival in patients prescribed the WCD. Short-term use of WCD allows appropriate risk stratification for decision on an ICD implantation in at-risk ischemic and nonischemic cardiomyopathy patients. Congenital/inherited heart disease patients had a higher risk of 1-year mortality even without an implanted ICD post-WCD.


Assuntos
Doenças Cardiovasculares/terapia , Cardioversão Elétrica/instrumentação , Dispositivos Eletrônicos Vestíveis , Idoso , Doenças Cardiovasculares/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Análise de Sobrevida , Resultado do Tratamento , Estados Unidos
7.
N Engl J Med ; 370(18): 1694-701, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24678999

RESUMO

BACKGROUND: The Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT) showed that early intervention with cardiac-resynchronization therapy with a defibrillator (CRT-D) in patients with an electrocardiographic pattern showing left bundle-branch block was associated with a significant reduction in heart-failure events over a median follow-up of 2.4 years, as compared with defibrillator therapy alone. METHODS: We evaluated the effect of CRT-D on long-term survival in the MADIT-CRT population. Post-trial follow-up over a median period of 5.6 years was assessed among all 1691 surviving patients (phase 1) and subsequently among 854 patients who were enrolled in post-trial registries (phase 2). All reported analyses were performed on an intention-to-treat basis. RESULTS: At 7 years of follow-up after initial enrollment, the cumulative rate of death from any cause among patients with left bundle-branch block was 18% among patients randomly assigned to CRT-D, as compared with 29% among those randomly assigned to defibrillator therapy alone (adjusted hazard ratio in the CRT-D group, 0.59; 95% confidence interval [CI], 0.43 to 0.80; P<0.001). The long-term survival benefit of CRT-D in patients with left bundle-branch block did not differ significantly according to sex, cause of cardiomyopathy, or QRS duration. In contrast, CRT-D was not associated with any clinical benefit and possibly with harm in patients without left bundle-branch block (adjusted hazard ratio for death from any cause, 1.57; 95% CI, 1.03 to 2.39; P=0.04; P<0.001 for interaction of treatment with QRS morphologic findings). CONCLUSIONS: Our findings indicate that in patients with mild heart-failure symptoms, left ventricular dysfunction, and left bundle-branch block, early intervention with CRT-D was associated with a significant long-term survival benefit. (Funded by Boston Scientific; ClinicalTrials.gov numbers, NCT00180271, NCT01294449, and NCT02060110.).


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Idoso , Bloqueio de Ramo/complicações , Terapia Combinada , Desfibriladores Implantáveis , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Índice de Gravidade de Doença , Volume Sistólico , Disfunção Ventricular Esquerda/complicações
8.
Am Heart J ; 186: 111-117, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28454824

RESUMO

BACKGROUND: The impact of body mass index (BMI) on the shock efficacy and patient adherence among patients using a wearable cardioverter defibrillator (WCD) is unknown. METHODS: Patients prescribed the WCD between January 1, 2008 and June 1, 2013, who experienced at least one episode of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and who received appropriate WCD therapy, were identified within a registry maintained by the manufacturer for regulatory, reimbursement, and administrative purposes. The registry contained patients' Body Mass Index (BMI) which was categorized as normal (18.0

Assuntos
Índice de Massa Corporal , Desfibriladores , Cooperação do Paciente , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Sobrepeso/complicações , Estudos Retrospectivos , Taquicardia Ventricular/complicações , Fatores de Tempo
9.
Am Heart J ; 189: 158-166, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28625372

RESUMO

Patients with diabetes mellitus, prior myocardial infarction, older age, and a relatively preserved left ventricular ejection fraction remain at risk for sudden cardiac death that is potentially amenable by the subcutaneous implantable cardioverter defibrillator with a good risk-benefit profile. The launched MADIT S-ICD study is designed to test the hypothesis that post-myocardial infarction diabetes patients with relatively preserved ejection fraction of 36%-50% will have a survival benefit from a subcutaneous implantable cardioverter defibrillator.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Infarto do Miocárdio/complicações , Idoso , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Estudos Prospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
10.
Europace ; 19(9): 1549-1555, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339581

RESUMO

AIMS: There is lack of conclusive evidence from randomized clinical trials on the efficacy and safety of upgrade to cardiac resynchronization therapy (CRT) in patients with implanted pacemakers (PM) or defibrillators (ICD) with reduced left ventricular ejection fraction (LVEF) and chronic heart failure (HF). The BUDAPEST-CRT Upgrade Study was designed to compare the efficacy and safety of CRT upgrade from conventional PM or ICD therapy in patients with intermittent or permanent right ventricular (RV) septal/apical pacing, reduced LVEF, and symptomatic HF. METHODS AND RESULTS: The BUDAPEST-CRT study is a prospective, randomized, multicentre, investigator-sponsored clinical trial. A total of 360 subjects will be enrolled with LVEF ≤ 35%, NYHA functional classes II-IVa, paced QRS ≥ 150 ms, and a RV pacing ≥ 20%. Patients will be followed for 12 months. Randomization is performed in a 3:2 ratio (CRT-D vs. ICD). The primary composite endpoint is all-cause mortality, a first HF event, or less than 15% reduction in left ventricular (LV) end-systolic volume at 12 months. Secondary endpoints are all-cause mortality, all-cause mortality or HF event, and LV volume reduction at 12 months. Tertiary endpoints include changes in quality of life, NYHA functional class, 6 min walk test, natriuretic peptides, and safety outcomes. CONCLUSION: The results of our prospective, randomized, multicentre clinical trial will provide important information on the role of cardiac resynchronization therapy with defibrillator (CRT-D) upgrade in patients with symptomatic HF, reduced LVEF, and wide-paced QRS with intermittent or permanent RV pacing. CLINICAL TRIALS.GOV IDENTIFIER: NCT02270840.


Assuntos
Estimulação Cardíaca Artificial , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Volume Sistólico , Função Ventricular Esquerda , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Doença Crônica , Protocolos Clínicos , Remoção de Dispositivo , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Europa (Continente) , Tolerância ao Exercício , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Israel , Estudos Prospectivos , Recuperação de Função Fisiológica , Projetos de Pesquisa , Fatores de Tempo , Resultado do Tratamento , Teste de Caminhada
11.
Europace ; 19(3): 335-345, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702851

RESUMO

The wearable cardioverter-defibrillator has been available for over a decade and now is frequently prescribed for patients deemed at high arrhythmic risk in whom the underlying pathology is potentially reversible or who are awaiting an implantable cardioverter-defibrillator. The use of the wearable cardioverter-defibrillator is included in the new 2015 ESC guidelines for the management of ventricular arrhythmias and prevention of sudden cardiac death. The present review provides insight into the current technology and an overview of this approach.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Arritmias Cardíacas/economia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Análise Custo-Benefício , Desfibriladores/economia , Difusão de Inovações , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/economia , Cardioversão Elétrica/mortalidade , Desenho de Equipamento , Custos de Cuidados de Saúde , Humanos , Cooperação do Paciente , Satisfação do Paciente , Fatores de Risco , Resultado do Tratamento
12.
Anal Bioanal Chem ; 409(3): 841-857, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27544522

RESUMO

During the production process of beer, it is of utmost importance to guarantee a high consistency of the beer quality. For instance, the bitterness is an essential quality parameter which has to be controlled within the specifications at the beginning of the production process in the unfermented beer (wort) as well as in final products such as beer and beer mix beverages. Nowadays, analytical techniques for quality control in beer production are mainly based on manual supervision, i.e., samples are taken from the process and analyzed in the laboratory. This typically requires significant lab technicians efforts for only a small fraction of samples to be analyzed, which leads to significant costs for beer breweries and companies. Fourier transform mid-infrared (FT-MIR) spectroscopy was used in combination with nonlinear multivariate calibration techniques to overcome (i) the time consuming off-line analyses in beer production and (ii) already known limitations of standard linear chemometric methods, like partial least squares (PLS), for important quality parameters Speers et al. (J I Brewing. 2003;109(3):229-235), Zhang et al. (J I Brewing. 2012;118(4):361-367) such as bitterness, citric acid, total acids, free amino nitrogen, final attenuation, or foam stability. The calibration models are established with enhanced nonlinear techniques based (i) on a new piece-wise linear version of PLS by employing fuzzy rules for local partitioning the latent variable space and (ii) on extensions of support vector regression variants (𝜖-PLSSVR and ν-PLSSVR), for overcoming high computation times in high-dimensional problems and time-intensive and inappropriate settings of the kernel parameters. Furthermore, we introduce a new model selection scheme based on bagged ensembles in order to improve robustness and thus predictive quality of the final models. The approaches are tested on real-world calibration data sets for wort and beer mix beverages, and successfully compared to linear methods, showing a clear out-performance in most cases and being able to meet the model quality requirements defined by the experts at the beer company. Figure Workflow for calibration of non-Linear model ensembles from FT-MIR spectra in beer production .


Assuntos
Cerveja/análise , Cerveja/normas , Análise de Alimentos/métodos , Espectroscopia de Infravermelho com Transformada de Fourier , Calibragem
13.
Pacing Clin Electrophysiol ; 40(3): 271-277, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27943296

RESUMO

BACKGROUND: The wearable cardioverter defibrillator (WCD) is an important approach for better risk stratification, applied to patients considered to be at high risk of sudden arrhythmic death. Patients with implanted pacemakers may also become candidates for use of the WCD. However, there is a potential risk that pacemaker signals may mislead the WCD detection algorithm and cause inappropriate WCD shock delivery. The aim of the study was to test the impact of different types of pacing, various right ventricular (RV) lead positions, and pacing modes for potential misleading of the WCD detection algorithm. METHODS: Sixty patients with implanted pacemakers received the WCD for a short time and each pacing mode (AAI, VVI, and DDD) was tested for at least 30 seconds in unipolar and bipolar pacing configuration. In case of triggering the WCD detection algorithm and starting the sequence of arrhythmia alarms, shock delivery was prevented by pushing of the response buttons. RESULTS: In six of 60 patients (10%), continuous unipolar pacing in DDD mode triggered the WCD detection algorithm. In no patient, triggering occurred with bipolar DDD pacing, unipolar and bipolar AAI, and VVI pacing. Triggering was independent of pacing amplitude, RV pacing lead position, and pulse generator implantation site. CONCLUSION: Unipolar DDD pacing bears a high risk of false triggering of the WCD detection algorithm. Other types of unipolar pacing and all bipolar pacing modes do not seem to mislead the WCD detection algorithm. Therefore, patients with no reprogrammable unipolar DDD pacing should not become candidates for the WCD.


Assuntos
Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Desfibriladores/efeitos adversos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/prevenção & controle , Marca-Passo Artificial , Próteses e Implantes , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Pacing Clin Electrophysiol ; 40(1): 9-16, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27808410

RESUMO

BACKGROUND: Weight loss has been associated with adverse outcomes among heart failure (HF) patients, including those receiving cardiac resynchronization therapy with defibrillator (CRT-D). The effect of significant weight change on inappropriate implantable cardioverter-defibrillator (ICD) therapy among CRT-D patients is not well understood. METHODS: We evaluated the impact of significant weight change at 1 year on subsequent inappropriate ICD therapy during follow-up among 993 CRT-D patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy. Patients were divided into three subgroups based on weight change at 1 year after enrollment: weight loss (weight loss ≥ 5%), weight gain (weight gain ≥ 5%), and stable weight (weight loss and weight gain < 5%). The primary end point was inappropriate ICD therapy. Secondary end point included inappropriate ICD therapy related to supraventricular arrhythmias (SVAs). RESULTS: There were 102 (10.3%) patients who experienced weight loss, 689 (69.4%) whose weight was stable, and 202 (20.3%) who gained weight at 1 year. Patients with weight loss had increased risk of subsequent inappropriate ICD therapy relative to patients with stable weight (hazard ratio [HR] = 2.35, 95% confidence interval [CI]: 1.39-3.98, P = 0.001) or weight gain (HR = 2.27, 95% CI: 1.18-4.38, P = 0.014). Furthermore, patients losing weight were at greater risk of subsequent inappropriate ICD therapy related to SVAs when compared to patients with stable weight (HR = 2.16, 95% CI: 1.18-3.95, P = 0.013) or weight gain (HR = 2.02, 95% CI: 0.95-4.29, P = 0.068). CONCLUSION: In mild HF patients receiving CRT-D, significant weight loss at 1 year is associated with increased risk of subsequent inappropriate ICD therapy, including risk related to SVAs.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Traumatismos por Eletricidade/epidemiologia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/prevenção & controle , Obesidade/epidemiologia , Magreza/epidemiologia , Idoso , Causalidade , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Resultado do Tratamento , Estados Unidos/epidemiologia
15.
Artigo em Inglês | MEDLINE | ID: mdl-27629147

RESUMO

BACKGROUND: The effect of chronic kidney disease (CKD) on benefit from cardiac resynchronization therapy with defibrillator (CRT-D) in reducing ventricular tachyarrhythmia (VTA) risk among mild heart failure (HF) patients is not well understood. METHODS: We evaluated the impact of baseline renal function on VTAs in 1274 left bundle branch block (LBBB) patients enrolled in MADIT-CRT. Two prespecified subgroups were created based on estimated glomerular filtration rate (GFR): GFR <60 (n = 413) and GFR ≥60 ml/min/1.73 m2 (n = 861). Primary end point was ventricular tachycardia/ventricular fibrillation/death (VT/VF/death). Secondary end points were any VT/VF and ventricular tachycardia ≥ 200 bpm or VF (fast VT/VF). RESULTS: There were 413 (32%) LBBB patients presenting with CKD, primarily of moderate severity (GFR mean 48.1 ± 8.3). For patients with and without CKD, CRT-D was associated with lower risk of the primary end point (GFR<60: HR = 0.61, 95% CI: 0.41-0.89, p = .010; GFR≥60: HR = 0.58, 95% CI: 0.52-0.89, p = .005), relative to ICD-only treatment. For patients in both renal function categories, CRT-D in comparison to ICD alone was associated with lower risk of VT/VF (GFR<60: HR = 0.68, 95% CI: 0.42-1.10, p = .113; GFR≥60: HR = 0.65, 95% CI: 0.48-0.88, p = .005) and fast VT/VF (GFR<60: HR = 0.49, 95% CI: 0.25-0.96, p = .038; GFR≥60: HR = 0.55, 95% CI: 0.39-0.80, p = .001), when accounting for competing mortality risk. This effect was independent of CRT-induced reverse remodeling. CONCLUSION: Among mild HF patients with LBBB, those with and without CKD both derived benefit from CRT-D in risk reduction in VTAs, independent of cardiac reverse remodeling.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Insuficiência Renal Crônica/complicações , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Taquicardia Ventricular/prevenção & controle , Resultado do Tratamento
16.
Circulation ; 132(17): 1613-9, 2015 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-26316618

RESUMO

BACKGROUND: Prospective data on the safety and efficacy of the wearable cardioverter defibrillator (WCD) in a real-world setting are lacking. The Prospective Registry of Patients Using the Wearable Defibrillator (WEARIT-II) Registry was designed to provide real-world data on the WCD as a strategy during a period of risk stratification. METHODS AND RESULTS: The WEARIT-II Registry enrolled 2000 patients with ischemic (n=805, 40%), or nonischemic cardiomyopathy (n=927, 46%), or congenital/inherited heart disease (n=268) prescribed WCD between August 2011 and February 2014. Clinical data, arrhythmia events, implantable cardioverter defibrillator implantation, and improvement in ejection fraction were captured. The median age was 62 years; the median ejection fraction was 25%. The median WCD wear time was 90 days, with median daily use of 22.5 hours. There was a total of 120 sustained ventricular tachyarrhythmias in 41 patients, of whom 54% received appropriate WCD shock. Only 10 patients (0.5%) received inappropriate WCD therapy. The rate of sustained ventricular tachyarrhythmias by 3 months was 3% among patients with ischemic cardiomyopathy and congenital/inherited heart disease, and 1% among nonischemic patients (P=0.02). At the end of WCD use, 840 patients (42%) were implanted with an implantable cardioverter defibrillator. The most frequent reason not to implant an implantable cardioverter defibrillator following WCD use was improvement in ejection fraction. CONCLUSIONS: The WEARIT-II Registry demonstrates a high rate of sustained ventricular tachyarrhythmias at 3 months in at-risk patients who are not eligible for an implantable cardioverter defibrillator, and suggests that the WCD can be safely used to protect patients during this period of risk assessment.


Assuntos
Arritmias Cardíacas/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Idoso , Arritmias Cardíacas/tratamento farmacológico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Cardiomiopatias/complicações , Fármacos Cardiovasculares/uso terapêutico , Terapia Combinada , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores/efeitos adversos , Desfibriladores/estatística & dados numéricos , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Seguimentos , Cardiopatias Congênitas/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Cooperação do Paciente , Prescrições/estatística & dados numéricos , Estudos Prospectivos , Sistema de Registros , Volume Sistólico
17.
J Card Fail ; 22(2): 143-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26433087

RESUMO

BACKGROUND: Cardiac resynchronization with defibrillators (CRT-D) reduces heart failure and mortality compared with defibrillators alone. Whether this applies to all ages is unclear. METHODS AND RESULTS: We assessed the association of age on heart failure and death as a post hoc analysis of the MADIT-CRT follow-up study, in which 1,281 patients with class I/II heart failure (HF) were randomized to CRT-D or implantable cardioverter-defibrillators alone. Different age groups (<60, 60-74, and ≥75 years) were evaluated over 7 years for mortality and HF events. Among the 3 age groups, there were 399, 651, and 231 patients, respectively. We compared events with the use of a multivariate regression model. CRT-D compared with defibrillators alone significantly reduced the composite of HF or death across all age groups: <60 years: relative risk reduction (RRR) = 36%; 60-74 years: RRR = 61%; ≥75 years: RRR = 56%. CRT-D significantly reduced HF in all age groups: <60 years: RRR = 49%; 60-74 years: RRR = 62%; ≥75 years: RRR = 74%. CRT-D was associated with significant mortality reduction only in the 60-74 year age group: RRR = 59%. CONCLUSIONS: CRT-D reduced HF events and the composite of mortality or HF events during long-term follow-up in all age groups. CRT-D reduced mortality only in the 60-74 year age group.


Assuntos
Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Desfibriladores Implantáveis/estatística & dados numéricos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Estatísticas não Paramétricas , Resultado do Tratamento
19.
Eur Heart J ; 36(7): 425-33, 2015 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-25176942

RESUMO

AIM: The neural cardiac therapy for heart failure (NECTAR-HF) was a randomized sham-controlled trial designed to evaluate whether a single dose of vagal nerve stimulation (VNS) would attenuate cardiac remodelling, improve cardiac function and increase exercise capacity in symptomatic heart failure patients with severe left ventricular (LV) systolic dysfunction despite guideline recommended medical therapy. METHODS: Patients were randomized in a 2 : 1 ratio to receive therapy (VNS ON) or control (VNS OFF) for a 6-month period. The primary endpoint was the change in LV end systolic diameter (LVESD) at 6 months for control vs. therapy, with secondary endpoints of other echocardiography measurements, exercise capacity, quality-of-life assessments, 24-h Holter, and circulating biomarkers. RESULTS: Of the 96 implanted patients, 87 had paired datasets for the primary endpoint. Change in LVESD from baseline to 6 months was -0.04 ± 0.25 cm in the therapy group compared with -0.08 ± 0.32 cm in the control group (P = 0.60). Additional echocardiographic parameters of LV end diastolic dimension, LV end systolic volume, left ventricular end diastolic volume, LV ejection fraction, peak V02, and N-terminal pro-hormone brain natriuretic peptide failed to show superiority compared to the control group. However, there were statistically significant improvements in quality of life for the Minnesota Living with Heart Failure Questionnaire (P = 0.049), New York Heart Association class (P = 0.032), and the SF-36 Physical Component (P = 0.016) in the therapy group. CONCLUSION: Vagal nerve stimulation as delivered in the NECTAR-HF trial failed to demonstrate a significant effect on primary and secondary endpoint measures of cardiac remodelling and functional capacity in symptomatic heart failure patients, but quality-of-life measures showed significant improvement.


Assuntos
Insuficiência Cardíaca/terapia , Estimulação do Nervo Vago/métodos , Eletrocardiografia Ambulatorial , Tolerância ao Exercício/fisiologia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Qualidade de Vida , Resultado do Tratamento , Estimulação do Nervo Vago/efeitos adversos , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Remodelação Ventricular/fisiologia
20.
N Engl J Med ; 367(24): 2275-83, 2012 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-23131066

RESUMO

BACKGROUND: The implantable cardioverter-defibrillator (ICD) is highly effective in reducing mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are frequent, with potential adverse effects. METHODS: We randomly assigned 1500 patients with a primary-prevention indication to receive an ICD with one of three programming configurations. The primary objective was to determine whether programmed high-rate therapy (with a 2.5-second delay before the initiation of therapy at a heart rate of ≥200 beats per minute) or delayed therapy (with a 60-second delay at 170 to 199 beats per minute, a 12-second delay at 200 to 249 beats per minute, and a 2.5-second delay at ≥250 beats per minute) was associated with a decrease in the number of patients with a first occurrence of inappropriate antitachycardia pacing or shocks, as compared with conventional programming (with a 2.5-second delay at 170 to 199 beats per minute and a 1.0-second delay at ≥200 beats per minute). RESULTS: During an average follow-up of 1.4 years, high-rate therapy and delayed ICD therapy, as compared with conventional device programming, were associated with reductions in a first occurrence of inappropriate therapy (hazard ratio with high-rate therapy vs. conventional therapy, 0.21; 95% confidence interval [CI], 0.13 to 0.34; P<0.001; hazard ratio with delayed therapy vs. conventional therapy, 0.24; 95% CI, 0.15 to 0.40; P<0.001) and reductions in all-cause mortality (hazard ratio with high-rate therapy vs. conventional therapy, 0.45; 95% CI, 0.24 to 0.85; P=0.01; hazard ratio with delayed therapy vs. conventional therapy, 0.56; 95% CI, 0.30 to 1.02; P=0.06). There were no significant differences in procedure-related adverse events among the three treatment groups. CONCLUSIONS: Programming of ICD therapies for tachyarrhythmias of 200 beats per minute or higher or with a prolonged delay in therapy at 170 beats per minute or higher, as compared with conventional programming, was associated with reductions in inappropriate therapy and all-cause mortality during long-term follow-up. (Funded by Boston Scientific; MADIT-RIT ClinicalTrials.gov number, NCT00947310.).


Assuntos
Desfibriladores Implantáveis , Taquicardia/terapia , Idoso , Desfibriladores Implantáveis/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Feminino , Seguimentos , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Taquicardia/diagnóstico , Taquicardia/mortalidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA