Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 30(15): 26027-26042, 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-36236801

RESUMO

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh's criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

2.
J Synchrotron Radiat ; 28(Pt 1): 309-317, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399582

RESUMO

Ptychography is a rapidly developing scanning microscopy which is able to view the internal structures of samples at a high resolution beyond the illumination size. The achieved spatial resolution is theoretically dose-limited. A broadband source can provide much higher flux compared with a monochromatic source; however, it conflicts with the necessary coherence requirements of this coherent diffraction imaging technique. In this paper, a multi-wavelength reconstruction algorithm has been developed to deal with the broad bandwidth in ptychography. Compared with the latest development of mixed-state reconstruction approach, this multi-wavelength approach is more accurate in the physical model, and also considers the spot size variation as a function of energy due to the chromatic focusing optics. Therefore, this method has been proved in both simulation and experiment to significantly improve the reconstruction when the source bandwidth, illumination size and scan step size increase. It is worth mentioning that the accurate and detailed information of the energy spectrum for the incident beam is not required in advance for the proposed method. Further, we combine multi-wavelength and mixed-state approaches to jointly solve temporal and spatial partial coherence in ptychography so that it can handle various disadvantageous experimental effects. The significant relaxation in coherence requirements by our approaches allows the use of high-flux broadband X-ray sources for high-efficient and high-resolution ptychographic imaging.

3.
Langmuir ; 29(10): 3439-45, 2013 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-23432093

RESUMO

Control over the oxidation state and crystalline phase of thin-film iron oxides was achieved by low-temperature atomic layer deposition (ALD), utilizing a novel iron precursor, bis(2,4-methylpentadienyl)iron. This low-temperature (T = 120 °C) route to conformal deposition of crystalline Fe3O4 or α-Fe2O3 thin films is determined by the choice of oxygen source selected for the second surface half-reaction. The approach employs ozone to produce fully oxidized α-Fe2O3 or a milder oxidant, H2O2, to generate the Fe(2+)/Fe(3+) spinel, Fe3O4. Both processes show self-limiting surface reactions and deposition rates of at least 0.6 Å/cycle, a significantly high growth rate at such mild conditions. We utilized this process to prepare conformal iron oxide thin films on a porous framework, for which α-Fe2O3 is active for photocatalytic water splitting.

4.
Light Sci Appl ; 12(1): 131, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37248235

RESUMO

Noninvasive X-ray imaging of nanoscale three-dimensional objects, such as integrated circuits (ICs), generally requires two types of scanning: ptychographic, which is translational and returns estimates of the complex electromagnetic field through the IC; combined with a tomographic scan, which collects these complex field projections from multiple angles. Here, we present Attentional Ptycho-Tomography (APT), an approach to drastically reduce the amount of angular scanning, and thus the total acquisition time. APT is machine learning-based, utilizing axial self-Attention for Ptycho-Tomographic reconstruction. APT is trained to obtain accurate reconstructions of the ICs, despite the incompleteness of the measurements. The training process includes regularizing priors in the form of typical patterns found in IC interiors, and the physics of X-ray propagation through the IC. We show that APT with ×12 reduced angles achieves fidelity comparable to the gold standard Simultaneous Algebraic Reconstruction Technique (SART) with the original set of angles. When using the same set of reduced angles, then APT also outperforms Filtered Back Projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT) and SART. The time needed to compute the reconstruction is also reduced, because the trained neural network is a forward operation, unlike the iterative nature of these alternatives. Our experiments show that, without loss in quality, for a 4.48 × 93.2 × 3.92 µm3 IC (≃6 × 108 voxels), APT reduces the total data acquisition and computation time from 67.96 h to 38 min. We expect our physics-assisted and attention-utilizing machine learning framework to be applicable to other branches of nanoscale imaging, including materials science and biological imaging.

5.
Rev Sci Instrum ; 91(8): 085115, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872941

RESUMO

Determining real-time changes in the local atomistic order is important for a mechanistic understanding of shock wave induced structural and chemical changes. However, the single event and short duration (nanosecond times) nature of shock experiments pose challenges in obtaining Extended X-ray Absorption Fine Structure (EXAFS) measurements-typically used for monitoring local order changes. Here, we report on a new single pulse (∼100 ps duration) transmission geometry EXAFS capability for use in laser shock-compression experiments at the Dynamic Compression Sector (DCS), Advanced Photon Source. We used a flat plate of highly oriented pyrolytic graphite (HOPG) as the spectrometer element to energy disperse x rays transmitted through the sample. It provided high efficiency with ∼15% of the x rays incident on the HOPG reaching an x-ray area detector with high quantum efficiency. This combination resulted in a good signal-to-noise ratio (∼103), an energy resolution of ∼10 eV at 10 keV, EXAFS spectra covering 100 s of eV, and a good pulse to pulse reproducibility of our single pulse measurements. Ambient EXAFS spectra for Cu and Au are compared to the reference spectra, validating our measurement system. Comparison of single pulse EXAFS results for ambient and laser shocked Ge(100) shows large changes in the local structure of the short lived state of shocked Ge. The current DCS EXAFS capability can be used to perform single pulse measurements in laser shocked materials from ∼9 keV to 13 keV. These EXAFS developments will be available to all users of the DCS.

6.
Sci Rep ; 10(1): 19550, 2020 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-33177558

RESUMO

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. In this paper, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

7.
Rev Sci Instrum ; 90(8): 083701, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31472643

RESUMO

Motivated by the advanced photon source upgrade, a new hard X-ray microscope called "Velociprobe" has been recently designed and built for fast ptychographic imaging with high spatial resolution. We are addressing the challenges of high-resolution and fast scanning with novel hardware designs, advanced motion controls, and new data acquisition strategies, including the use of high-bandwidth interferometric measurements. The use of granite, air-bearing-supported stages provides the necessary long travel ranges for coarse motion to accommodate real samples and variable energy operation while remaining highly stable during fine scanning. Scanning the low-mass zone plate enables high-speed and high-precision motion of the probe over the sample. With an advanced control algorithm implemented in a closed-loop feedback system, the setup achieves a position resolution (3σ) of 2 nm. The instrument performance is evaluated by 2D fly-scan ptychography with our developed data acquisition strategies. A spatial resolution of 8.8 nm has been demonstrated on a Au test sample with a detector continuous frame rate of 200 Hz. Using a higher flux X-ray source provided by double-multilayer monochromator, we achieve 10 nm resolution for an integrated circuit sample in an ultrafast scan with a detector's full continuous frame rate of 3000 Hz (0.33 ms per exposure), resulting in an outstanding imaging rate of 9 × 104 resolution elements per second.

8.
Am J Surg Pathol ; 41(7): 1005-1010, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28505008

RESUMO

Multinodular and vacuolating neuronal tumor is a recently described seizure-associated entity with overlapping features of a malformative and neoplastic process. We report a case of multinodular and vacuolating neuronal tumor in a 29-year-old man with a history of recent headaches and complex partial seizures. Neuroimaging revealed a nonenhancing, T2 and T2 fluid-attenuated inversion recovery hyperintense multinodular lesion in the right temporal lobe. Lesional tissue demonstrated well-demarcated nodules of ganglioid cells with vacuolation of both the perikarya and the fibrillary neuropil-like background. The ganglioid cells showed weak cytoplasmic reactivity for synaptophysin and were nonreactive for neurofilament and chromogranin. CD34-positive stellate cells were present within the nodules. A 50-gene next-generation sequencing panel did not identify any somatic mutations in genomic DNA extracted from the tumor.


Assuntos
Neoplasias Encefálicas/patologia , Convulsões/etiologia , Lobo Temporal/patologia , Adulto , Neoplasias Encefálicas/complicações , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Lobo Temporal/diagnóstico por imagem
9.
Rev Sci Instrum ; 86(11): 113901, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26628145

RESUMO

Synchrotron characterization techniques provide some of the most powerful tools for the study of film structure and chemistry. The brilliance and tunability of the Advanced Photon Source allow access to scattering and spectroscopic techniques unavailable with in-house laboratory setups and provide the opportunity to probe various atomic layer deposition (ALD) processes in situ starting at the very first deposition cycle. Here, we present the design and implementation of a portable ALD instrument which possesses a modular reactor scheme that enables simple experimental switchover between various beamlines and characterization techniques. As first examples, we present in situ results for (1) X-ray surface scattering and reflectivity measurements of epitaxial ZnO ALD on sapphire, (2) grazing-incidence small angle scattering of MnO nucleation on silicon, and (3) grazing-incidence X-ray absorption spectroscopy of nucleation-regime Er2O3 ALD on amorphous ALD alumina and single crystalline sapphire.

10.
Science ; 324(5925): 367-70, 2009 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-19372426

RESUMO

Metal oxide semiconductor field-effect transistors, formed using silicon dioxide and silicon, have undergone four decades of staggering technological advancement. With fundamental limits to this technology close at hand, alternatives to silicon dioxide are being pursued to enable new functionality and device architectures. We achieved ferroelectric functionality in intimate contact with silicon by growing coherently strained strontium titanate (SrTiO3) films via oxide molecular beam epitaxy in direct contact with silicon, with no interfacial silicon dioxide. We observed ferroelectricity in these ultrathin SrTiO3 layers by means of piezoresponse force microscopy. Stable ferroelectric nanodomains created in SrTiO3 were observed at temperatures as high as 400 kelvin.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA