Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Radiol Prot ; 39(4): R37-R50, 2019 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-31307030

RESUMO

This paper provides a summary of the Education and Training (E&T) activities that have been developed and organised by the European Radiation Dosimetry Group (EURADOS) in recent years and in the case of Training Courses over the last decade. These E&T actions include short duration Training Courses on well-established topics organised within the activity of EURADOS Working Groups (WGs), or one-day events integrated in the EURADOS Annual Meeting (workshops, winter schools, the intercomparison participants' sessions and the learning network, among others). Moreover, EURADOS has recently established a Young Scientist Grant and a Young Scientist Award. The Grant supports young scientists by encouraging them to perform research projects at other laboratories of the EURADOS network. The Award is given in recognition of excellent work developed within the WGs' work programme. Additionally, EURADOS supports the dissemination of knowledge in radiation dosimetry by promoting and endorsing conferences such as the individual monitoring (IM) series, the neutron and ion dosimetry symposia (NEUDOS) and contributions to E&T sessions at specific events.

2.
Neuroepidemiology ; 37(2): 102-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21921643

RESUMO

BACKGROUND: The aim of this study was to estimate the prevalence of multiple sclerosis (MS) in the district of Sumadija (central part of Serbia). METHODS: All persons suffering from MS, with permanent residence in the region, were recruited. Prevalence was calculated on December 31, 2006, according to a standard procedure. RESULTS: On December 31, 2006, one hundred ninety-four patients (72 males and 122 females) were found to have MS. We found a crude MS prevalence of 64.9/100,000 (49.3/100,000 for males and 79.9/ 100,000 for females). The highest prevalence rates were registered in the age group of 30-39 years for females and 40-49 years for males, although the age-specific rates were higher in females in all age groups. The mean age at onset was 34.2 ± 9.3 years. The average duration of MS was 8.9 ± 6.2 years. The median EDSS score was 3.9 ± 2.0. The course of MS was relapsing-remitting in 63.9% of patients, secondary progressive in 32.5%, and primary progressive in 3.6%. At MS onset, motor symptoms were present in 70.1% of patients, sensory in 40.7%, cerebellar in 21.1%, brainstem in 15.5%, visual in 22.2%, and bowel/bladder disturbances in 22.2%. CONCLUSIONS: Our results demonstrate that the MS prevalence registered in the Serbian district Sumadija is similar to that of other surrounding areas in Southeastern Europe.


Assuntos
Esclerose Múltipla/diagnóstico , Esclerose Múltipla/epidemiologia , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vigilância da População/métodos , Prevalência , Sérvia/epidemiologia , Adulto Jovem
3.
Phys Med ; 87: 131-135, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34153572

RESUMO

Occupational radiation doses from interventional procedures have the potential to be relatively high. The requirement to optimise these doses encourages the use of electronic or active personal dosimeters (APDs) which are now increasingly used in hospitals. They are typically used in tandem with a routine passive dosimetry monitoring programme, with APDs used for real-time readings, for training purposes and when new imaging technology is introduced. However, there are limitations when using APDs. A survey in hospitals to identify issues related to the use of APDs was recently completed, along with an extensive series of APD tests by the EURADOS Working Group 12 on Dosimetry for Medical Imaging. The aim of this review paper is to summarise the state of the art regarding the use of APDs. We also used the results of our survey and our tests to develop a set of recommendations for the use of APDs in the clinical interventional radiology/cardiology settings, and draw attention to some of the current challenges.


Assuntos
Exposição Ocupacional , Monitoramento de Radiação , Proteção Radiológica , Hospitais , Exposição Ocupacional/análise , Doses de Radiação , Radiologia Intervencionista , Local de Trabalho
4.
Phys Med ; 82: 134-143, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33611050

RESUMO

The lack of mailed dosimetry audits of proton therapy centres in Europe has encouraged researchers of EURADOS Working Group 9 (WG9) to compare response of several existing passive detector systems in therapeutic pencil beam scanning. Alanine Electron Paramagnetic Resonance dosimetry systems from 3 different institutes (ISS, Italy; UH, Belgium and IFJ PAN, Poland), natLiF:Mg, Ti (MTS-N) and natLiF:Mg, Cu, P (MCP-N) thermoluminescent dosimeters (TLDs), GD-352M radiophotoluminescent glass dosimeters (RPLGDs) and Al2O3:C optically stimulated dosimeters (OSLDs) were evaluate. Dosimeter repeatability, batch reproducibility and response in therapeutic Pencil Beam Scanning were verified for implementation as mail auditing system. Alanine detectors demonstrated the lowest linear energy transfer (LET) dependence with an agreement between measured and treatment planning system (TPS) dose below 1%. The OSLDs measured on average a 6.3% lower dose compared to TPS calculation, with no significant difference between varying modulations and ranges. Both GD-352M and MCP-N measured a lower dose than the TPS and luminescent response was dependent on the LET of the therapeutic proton beam. Thermoluminescent response of MTS-N was also found to be dependent on the LET and a higher dose than TPS was measured with the most pronounced increase of 11%. As alanine detectors are characterized by the lowest energy dependence for different parameters of therapeutic pencil beam scanning they are suitable candidates for mail auditing in proton therapy. The response of luminescence detector systems have shown promises even though more careful calibration and corrections are needed for its implementation as part of a mailed dosimetry audit system.


Assuntos
Terapia com Prótons , Bélgica , Europa (Continente) , Itália , Polônia , Prótons , Dosímetros de Radiação , Radiometria , Reprodutibilidade dos Testes , Dosimetria Termoluminescente
5.
Radiat Prot Dosimetry ; 194(1): 42-56, 2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-33989429

RESUMO

Since 2012, the European Radiation Dosimetry Group (EURADOS) has developed its Strategic Research Agenda (SRA), which contributes to the identification of future research needs in radiation dosimetry in Europe. Continued scientific developments in this field necessitate regular updates and, consequently, this paper summarises the latest revision of the SRA, with input regarding the state of the art and vision for the future contributed by EURADOS Working Groups and through a stakeholder workshop. Five visions define key issues in dosimetry research that are considered important over at least the next decade. They include scientific objectives and developments in (i) updated fundamental dose concepts and quantities, (ii) improved radiation risk estimates deduced from epidemiological cohorts, (iii) efficient dose assessment for radiological emergencies, (iv) integrated personalised dosimetry in medical applications and (v) improved radiation protection of workers and the public. This SRA will be used as a guideline for future activities of EURADOS Working Groups but can also be used as guidance for research in radiation dosimetry by the wider community. It will also be used as input for a general European research roadmap for radiation protection, following similar previous contributions to the European Joint Programme for the Integration of Radiation Protection Research, under the Horizon 2020 programme (CONCERT). The full version of the SRA is available as a EURADOS report (www.eurados.org).


Assuntos
Monitoramento de Radiação , Proteção Radiológica , Europa (Continente) , Humanos , Doses de Radiação , Radiação Ionizante , Radiometria
6.
Phys Med Biol ; 66(3): 035012, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33202399

RESUMO

The lowest possible energy of proton scanning beam in cyclotron proton therapy facilities is typically between 60 and 100 MeV. Treatment of superficial lesions requires a pre-absorber to deliver doses to shallower volumes. In most of the cases a range shifter (RS) is used, but as an alternative solution, a patient-specific 3D printed proton beam compensator (BC) can be applied. A BC enables further reduction of the air gap and consequently reduction of beam scattering. Such pre-absorbers are additional sources of secondary radiation. The aim of this work was the comparison of RS and BC with respect to out-of-field doses for a simulated treatment of superficial paediatric brain tumours. EURADOS WG9 performed comparative measurements of scattered radiation in the Proteus C-235 IBA facility (Cyclotron Centre Bronowice at the Institute of Nuclear Physics, CCB IFJ PAN, Kraków, Poland) using two anthropomorphic phantoms-5 and 10 yr old-for a superficial target in the brain. Both active detectors located inside the therapy room, and passive detectors placed inside the phantoms were used. Measurements were supplemented by Monte Carlo simulation of the radiation transport. For the applied 3D printed pre-absorbers, out-of-field doses from both secondary photons and neutrons were lower than for RS. Measurements with active environmental dosimeters at five positions inside the therapy room indicated that the RS/BC ratio of the out-of-field dose was also higher than one, with a maximum of 1.7. Photon dose inside phantoms leads to higher out-of-field doses for RS than BC to almost all organs with the highest RS/BC ratio 12.5 and 13.2 for breasts for 5 and 10 yr old phantoms, respectively. For organs closest to the isocentre such as the thyroid, neutron doses were lower for BC than RS due to neutrons moderation in the target volume, but for more distant organs like bladder-conversely-lower doses for RS than BC were observed. The use of 3D printed BC as the pre-absorber placed in the near vicinity of patient in the treatment of superficial tumours does not result in the increase of secondary radiation compared to the treatment with RS, placed far from the patient.


Assuntos
Impressão Tridimensional , Terapia com Prótons/instrumentação , Doses de Radiação , Neoplasias Encefálicas/radioterapia , Criança , Simulação por Computador , Humanos , Método de Monte Carlo , Nêutrons , Imagens de Fantasmas , Dosagem Radioterapêutica
7.
Radiat Prot Dosimetry ; 188(1): 22-29, 2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-31832653

RESUMO

Medical staff in interventional procedures are among the professionals with the highest occupational doses. Active personal dosemeters (APDs) can help in optimizing the exposure during interventional procedures. However, there can be problems when using APDs during interventional procedures, due to the specific energy and angular distribution of the radiation field and because of the pulsed nature of the radiation. Many parameters like the type of interventional procedure, personal habits and working techniques, protection tools used and X-ray field characteristics influence the occupational exposure and the scattered radiation around the patient. In this paper, we compare the results from three types of APDs with a passive personal dosimetry system while being used in real clinical environment by the interventional staff. The results show that there is a large spread in the ratios of the passive and active devices.


Assuntos
Hospitais , Corpo Clínico , Exposição Ocupacional/análise , Dosímetros de Radiação , Radiologia Intervencionista , Humanos , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Local de Trabalho
8.
Ann ICRP ; 47(3-4): 20-34, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29664324

RESUMO

Since the early 1980s, the European Radiation Dosimetry Group (EURADOS) has been maintaining a network of institutions interested in the dosimetry of ionising radiation. As of 2017, this network includes more than 70 institutions (research centres, dosimetry services, university institutes, etc.), and the EURADOS database lists more than 500 scientists who contribute to the EURADOS mission, which is to promote research and technical development in dosimetry and its implementation into practice, and to contribute to harmonisation of dosimetry in Europe and its conformance with international practices. The EURADOS working programme is organised into eight working groups dealing with environmental, computational, internal, and retrospective dosimetry; dosimetry in medical imaging; dosimetry in radiotherapy; dosimetry in high-energy radiation fields; and harmonisation of individual monitoring. Results are published as freely available EURADOS reports and in the peer-reviewed scientific literature. Moreover, EURADOS organises winter schools and training courses on various aspects relevant for radiation dosimetry, and formulates the strategic research needs in dosimetry important for Europe. This paper gives an overview on the most important EURADOS activities. More details can be found at www.eurados.org .


Assuntos
Agências Internacionais , Exposição à Radiação/análise , Proteção Radiológica , Radiação Ionizante , Radiometria/normas , Humanos , Radiometria/instrumentação , Estudos Retrospectivos
9.
Phys Med Biol ; 63(8): 085017, 2018 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-29509148

RESUMO

Systematic 3D mapping of out-of-field doses induced by a therapeutic proton pencil scanning beam in a 300 × 300 × 600 mm3 water phantom was performed using a set of thermoluminescence detectors (TLDs): MTS-7 (7LiF:Mg,Ti), MTS-6 (6LiF:Mg,Ti), MTS-N (natLiF:Mg,Ti) and TLD-700 (7LiF:Mg,Ti), radiophotoluminescent (RPL) detectors GD-352M and GD-302M, and polyallyldiglycol carbonate (PADC)-based (C12H18O7) track-etched detectors. Neutron and gamma-ray doses, as well as linear energy transfer distributions, were experimentally determined at 200 points within the phantom. In parallel, the Geant4 Monte Carlo code was applied to calculate neutron and gamma radiation spectra at the position of each detector. For the cubic proton target volume of 100 × 100 × 100 mm3 (spread out Bragg peak with a modulation of 100 mm) the scattered photon doses along the main axis of the phantom perpendicular to the primary beam were approximately 0.5 mGy Gy-1 at a distance of 100 mm and 0.02 mGy Gy-1 at 300 mm from the center of the target. For the neutrons, the corresponding values of dose equivalent were found to be ~0.7 and ~0.06 mSv Gy-1, respectively. The measured neutron doses were comparable with the out-of-field neutron doses from a similar experiment with 20 MV x-rays, whereas photon doses for the scanning proton beam were up to three orders of magnitude lower.


Assuntos
Imageamento Tridimensional/métodos , Imagens de Fantasmas , Terapia com Prótons/métodos , Radiometria/métodos , Dosimetria Termoluminescente/métodos , Raios gama , Humanos , Método de Monte Carlo , Nêutrons , Fótons , Prótons , Radioatividade , Cintilografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Dosimetria Termoluminescente/instrumentação , Água
10.
Radiat Prot Dosimetry ; 180(1-4): 256-260, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29165619

RESUMO

Proton beam therapy has advantages in comparison to conventional photon radiotherapy due to the physical properties of proton beams (e.g. sharp distal fall off, adjustable range and modulation). In proton therapy, there is the possibility of sparing healthy tissue close to the target volume. This is especially important when tumours are located next to critical organs and while treating cancer in paediatric patients. On the other hand, the interactions of protons with matter result in the production of secondary radiation, mostly neutrons and gamma radiation, which deposit their energy at a distance from the target. The aim of this study was to compare the response of different passive dosimetry systems in mixed radiation field induced by proton pencil beam inside anthropomorphic phantoms representing 5 and 10 years old children. Doses were measured in different organs with thermoluminescent (MTS-7, MTS-6 and MCP-N), radiophotoluminescent (GD-352 M and GD-302M), bubble and poly-allyl-diglycol carbonate (PADC) track detectors. Results show that RPL detectors are the less sensitive for neutrons than LiF TLDs and can be applied for in-phantom dosimetry of gamma component. Neutron doses determined using track detectors, bubble detectors and pairs of MTS-7/MTS-6 are consistent within the uncertainty range. This is the first study dealing with measurements on child anthropomorphic phantoms irradiated by a pencil scanning beam technique.


Assuntos
Imagens de Fantasmas , Terapia com Prótons/instrumentação , Prótons , Radiometria/instrumentação , Dosimetria Termoluminescente/instrumentação , Algoritmos , Antropometria , Criança , Pré-Escolar , Desenho de Equipamento , Raios gama/uso terapêutico , Humanos , Método de Monte Carlo , Nêutrons , Doses de Radiação , Radiação Ionizante , Cintilografia , Dosagem Radioterapêutica
11.
Phys Med ; 54: 42-48, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30337009

RESUMO

Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14,922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm2), percutaneous coronary intervention (PCI, 85 Gy cm2), transcatheter aortic valve implantation (TAVI, 130 Gy cm2), electrophysiological procedures (12 Gy cm2) and pacemaker implantations. Pacemaker implantations were further divided into single-chamber (2.5 Gy cm2) and dual chamber (3.5 Gy cm2) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm2). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology.


Assuntos
Cardiologia/normas , Europa (Continente) , Valores de Referência
12.
Radiat Prot Dosimetry ; 174(4): 518-534, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27522054

RESUMO

The combination of fluoroscopically guided interventional procedures with computed tomography (CTF) has become widespread around the world. The benefits of CTF include the ability to obtain a real-time visualization of the entire body, increased target accuracy and improved visualization of biopsy needles. Modern CTF units work with variable frame rates for image selection, and therefore the dose distributions for patients and staff can considerably vary, creating growing concern in terms of the occupational exposure of interventionists and the drawback of a higher exposure of the patient. A literature review of the latest CTF publications is summarized in this article. A wide range of CTF studies reveal different treatment methods used in clinical practice, and therefore the differences in the exposures between them; as well as in the radiation protection tools and dose monitoring. Further optimization of radiation protection methods, harmonization of exposure patterns as well as training and education of CTF staff on the basis of the information in the survey, are strongly recommended.


Assuntos
Fluoroscopia , Doses de Radiação , Proteção Radiológica , Humanos , Exposição Ocupacional , Radiografia Intervencionista , Tomografia Computadorizada por Raios X
13.
Radiat Prot Dosimetry ; 119(1-4): 191-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16709712

RESUMO

Recently, two new types of 'tissue equivalent' thermoluminescent detectors (TLDs) have aroused attention: LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P. In this work the characteristics of both detectors were compared with the characteristics of the well-known type LiF:Mg,Ti detector, TLD-100. The following properties were investigated: the glow curve structures, relative sensitivity, batch homogeneity and uniformity, detection threshold, reproducibility of the response, linearity in the wide dose range and fading. Also, the energy dependence for medium and low energy X rays was determined in the range of mean energies between 33 and 116 keV. The results confirmed 'tissue equivalency' of both new types in the investigated range of photon energies. LiF:Mg,Cu,Na,Si detector has very high sensitivity (approximately 75 times higher than that of TLD-100) and is convenient for use in a very low range of doses. Li2B4O7:Cu,Ag,P detector shows some improvements in comparison with the previously prepared types of lithium borate. The most important is the five times higher sensitivity than that of TLD-100. This detector is also very promising, especially in medical dosimetry.


Assuntos
Boratos/química , Boratos/efeitos da radiação , Fluoretos/química , Fluoretos/efeitos da radiação , Compostos de Lítio/química , Compostos de Lítio/efeitos da radiação , Modelos Químicos , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Simulação por Computador , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Fósforo/química , Fósforo/efeitos da radiação , Doses de Radiação
14.
Radiat Prot Dosimetry ; 170(1-4): 208-12, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27143793

RESUMO

Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radiophotoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0  up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK•CEN-Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruder Boskovic Institute-Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to Hp(3), although some improvements may be necessary.


Assuntos
Cristalino/efeitos da radiação , Exposição Ocupacional/análise , Imagens de Fantasmas , Monitoramento de Radiação/instrumentação , Proteção Radiológica/métodos , Bélgica , Croácia , Vidro , Humanos , Modelos Lineares , Método de Monte Carlo , Exposição Ocupacional/prevenção & controle , Fótons , Doses de Radiação , Dosímetros de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação , Reprodutibilidade dos Testes , Raios X
15.
Radiat Prot Dosimetry ; 168(2): 223-34, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25752758

RESUMO

Since autumn 2012, the European Radiation Dosimetry Group (EURADOS) has been developing its Strategic Research Agenda (SRA), which is intended to contribute to the identification of future research needs in radiation dosimetry in Europe. The present article summarises-based on input from EURADOS Working Groups (WGs) and Voting Members-five visions in dosimetry and defines key issues in dosimetry research that are considered important for the next decades. The five visions include scientific developments required towards (a) updated fundamental dose concepts and quantities, (b) improved radiation risk estimates deduced from epidemiological cohorts, (c) efficient dose assessment for radiological emergencies, (d) integrated personalised dosimetry in medical applications and (e) improved radiation protection of workers and the public. The SRA of EURADOS will be used as a guideline for future activities of the EURADOS WGs. A detailed version of the SRA can be downloaded as a EURADOS report from the EURADOS website (www.eurados.org).


Assuntos
Pesquisa Biomédica , Monitoramento de Radiação/normas , Proteção Radiológica , Radiação Ionizante , Radiometria/normas , Europa (Continente) , Guias como Assunto , Humanos , Doses de Radiação
16.
Exp Hematol ; 4(4): 246-55, 1976 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-954882

RESUMO

Chickens sham-bursectomized as 52- to 64-hours-old embryos (SBx), chickens bursectomized at hatching (NeoBx) and chickens from which the bursal primordium was removed at 52-64 h of embryonation (EBx) were immunized with guinea pig red blood cells when 21 days old. Following the second injection of antigen, EBx chickens were found to elaborate ME-sensitive and ME-resistant hemagglutinins, to produce direct and indirect plaque-forming cells, and to contain lymphocytes bearing a specific bursa (Bu) antigen. These immune properties were more often expressed in sham-bursectomized and neonatally bursectomized chickens. Cytomorphological changes in the spleen, bone marrow and cecal tonsil of EBx chickens were typical for birds lacking the bursa. The number of lymphocytes and plasma cells in the bone marrow and liver of SBx, NeoBx and EBx chickens was very low. These results suggest that a very early embryonic bursectomy of chickens does not abolish humoral immunity completely and does not prevent the differentiation of Bu antigen-bearing lymphocytes.


Assuntos
Bolsa de Fabricius/fisiologia , Embrião de Galinha/imunologia , Galinhas/imunologia , Imunidade , Animais , Formação de Anticorpos , Peso Corporal , Medula Óssea/imunologia , Células da Medula Óssea , Fígado/citologia , Tamanho do Órgão , Tonsila Palatina/citologia , Tonsila Palatina/imunologia , Baço/citologia , Baço/imunologia , Timo/citologia , Timo/imunologia
17.
Phys Med ; 31(8): 1112-1117, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26439858

RESUMO

PURPOSE: Point detectors are frequently used to measure patient's maximum skin dose (MSD) in fluoroscopically-guided interventional procedures (IP). However, their performance and ability to detect the actual MSD are rarely evaluated. The present study investigates the sampling uncertainty associated with the use of grids of point detectors to measure MSD in IP. METHOD: Chemoembolisation of the liver (CE), percutaneous coronary intervention (PCI) and neuroembolisation (NE) procedures were studied. Spatial dose distributions were measured with XR-RV3 Gafchromic(®) films for 176 procedures. These distributions were used to simulate measurements performed using grids of detectors such as thermoluminescence detectors, with detector spacing from 1.4 up to 10 cm. RESULTS: The sampling uncertainty was the highest in PCI and NE procedures. With 40 detectors covering the film area (36 cm × 44 cm), the maximum dose would be on average 86% and 63% of the MSD measured with Gafchromic(®) films in CE and PCI procedures, respectively. In NE procedures, with 27 detectors covering the film area (14 cm × 35 cm), the maximum dose measured would be on average 82% of the MSD obtained with the Gafchromic(®) films. CONCLUSION: Thermoluminescence detectors show good energy and dose response in clinical beam qualities. However the poor spatial resolution of such point-like dosimeters may far outweigh their good dosimetric properties. The uncertainty from the sampling procedure should be estimated when point detectors are used in IP because it may lead to strong underestimation of the MSD.


Assuntos
Quimioembolização Terapêutica/métodos , Intervenção Coronária Percutânea/métodos , Doses de Radiação , Pele/efeitos da radiação , Fluoroscopia , Dosimetria Termoluminescente , Incerteza
18.
Med Phys ; 42(7): 4211-26, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26133620

RESUMO

PURPOSE: To investigate the optimal use of XR-RV3 GafChromic(®) films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. METHODS: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. RESULTS: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. CONCLUSIONS: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.


Assuntos
Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Algoritmos , Calibragem , Doses de Radiação , Pele/efeitos da radiação , Incerteza , Raios X
19.
Radiat Prot Dosimetry ; 164(1-2): 138-42, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25316909

RESUMO

To help operators acknowledge patient dose during interventional procedures, EURADOS WG-12 focused on measuring patient skin dose using XR-RV3 gafchromic films, thermoluminescent detector (TLD) pellets or 2D TL foils and on investigating possible correlation to the on-line dose indicators such as fluoroscopy time, Kerma-area product (KAP) and cumulative air Kerma at reference point (CK). The study aims at defining non-centre-specific European alert thresholds for skin dose in three interventional procedures: chemoembolization of the liver (CE), neuroembolization (NE) and percutaneous coronary interventions (PCI). Skin dose values of >3 Gy (ICRP threshold for skin injuries) were indeed measured in these procedures confirming the need for dose indicators that correlate with maximum skin dose (MSD). However, although MSD showed fairly good correlation with KAP and CK, several limitations were identified challenging the set-up of non-centre-specific European alert thresholds. This paper presents preliminary results of this wide European measurement campaign and focuses on the main challenges in the definition of European alert thresholds.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares/métodos , Radiografia Intervencionista/métodos , Radiometria/instrumentação , Pele/diagnóstico por imagem , Raios X , Absorção de Radiação , Humanos , Concentração Máxima Permitida , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fenômenos Fisiológicos da Pele/efeitos da radiação
20.
Med Phys ; 42(5): 2572-84, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25979049

RESUMO

PURPOSE: To characterize stray radiation around the target volume in scanning proton therapy and study the performance of active neutron monitors. METHODS: Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9-Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H(∗)(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs--tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye™ NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific™ FH-40G survey meter. Experiments involved a water tank phantom (60 × 30 × 30 cm(3)) representing the patient that was uniformly irradiated using a 3 mm spot diameter proton pencil beam with 10 cm modulation width, 19.95 cm distal beam range, and 10 × 10 cm(2) field size. RESULTS: Neutron spectrometry around the target volume showed two main components at the thermal and fast energy ranges. The study also revealed the large dependence of the energy distribution of neutrons, and consequently of out-of-field doses, on the primary beam direction (directional emission of intranuclear cascade neutrons) and energy (spectral composition of secondary neutrons). In addition, neutron mapping within the facility was conducted and showed the highest H(∗)(10) value of ∼ 51 µSv Gy(-1); this was measured at 1.15 m along the beam axis. H(∗)(10) values significantly decreased with distance and angular position with respect to beam axis falling below 2 nSv Gy(-1) at the entrance of the maze, at the door outside the room and below detection limit in the gantry control room, and at an adjacent room (<0.1 nSv Gy(-1)). Finally, the agreement on H(∗)(10) values between all detectors showed a direct dependence on neutron spectra at the measurement position. While conventional rem-counters (LB 6411, RadEye™ NL, NM2-458) underestimated the H(∗)(10) by up to a factor of 4, Hawk TEPCs and the WENDI-II range-extended detector were found to have good performance (within 20%) even at the highest neutron fluence and energy range. Meanwhile, secondary photon dose equivalents were found to be up to five times lower than neutrons; remaining nonetheless of concern to the patient. CONCLUSIONS: Extended-range BSS, TEPCs, and the WENDI-II enable accurate measurements of stray neutrons while other rem-counters are not appropriate considering the high-energy range of neutrons involved in proton therapy.


Assuntos
Terapia com Prótons/métodos , Radiometria/métodos , Europa (Continente) , Nêutrons , Imagens de Fantasmas , Fótons , Terapia com Prótons/instrumentação , Prótons , Doses de Radiação , Radiometria/instrumentação , Análise Espectral/instrumentação , Análise Espectral/métodos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA