1.
Annu Rev Biomed Eng ; 26(1): 197-221, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38346276

RESUMO

Insertable biosensor systems are medical diagnostic devices with two primary components: an implantable biosensor within the body and a wearable monitor that can remotely interrogate the biosensor from outside the body. Because the biosensor does not require a physical connection to the electronic monitor, insertable biosensor systems promise improved patient comfort, reduced inflammation and infection risk, and extended operational lifetimes relative to established percutaneous biosensor systems. However, the lack of physical connection also presents technical challenges that have necessitated new innovations in developing sensing chemistries, transduction methods, and communication modalities. In this review, we discuss the key developments that have made insertables a promising option for longitudinal biometric monitoring and highlight the essential needs and existing development challenges to realizing the next generation of insertables for extended-use diagnostic and prognostic devices.


Assuntos
Técnicas Biossensoriais , Desenho de Equipamento , Dispositivos Eletrônicos Vestíveis , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Humanos , Próteses e Implantes , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos
2.
Macromol Rapid Commun ; 43(9): e2100902, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35253953

RESUMO

The adoption of existing continuous glucose monitors (CGMs) is limited by user burden. Herein, a design for a glucose biosensor with the potential for subcutaneous implantation, without the need for a transcutaneous probe or affixed transmitter, is presented. The design is based on the combination of an enzyme-driven phosphorescence lifetime-based glucose-sensing assay and a thermoresponsive membrane anticipated to reduce biofouling. The metalloporphyrin, Pd meso-tetra(sulfophenyl)-tetrabenzoporphyrin ([PdPh4 (SO3 Na)4 TBP]3 , HULK) as well as glucose oxidase (GOx) are successfully incorporated into the UV-cured double network (DN) membranes by leveraging electrostatic interactions and covalent conjugation, respectively. The oxygen-sensitive metalloporphyrin is incorporated at different levels within the DN membranes. These HULK-containing membranes retain the desired thermosensitivity, as well as glucose diffusivity and primary optical properties of the metalloporphyrin. After subsequently modifying the membranes with GOx, glucose-sensing experiments reveal that membranes prepared with the lowest GOx level exhibit the expected increase in phosphorescent lifetime for glucose concentrations up to 200 mg dL-1 . For membranes prepared with relatively higher GOx, oxygen-limited behavior is considered the source of diminished sensitivity at higher glucose levels. This proof-of-concept study demonstrates the promising potential of a biosensor design integrating a specific optical biosensing chemistry into a thermoresponsive hydrogel membrane.


Assuntos
Técnicas Biossensoriais , Metaloporfirinas , Enzimas Imobilizadas/química , Glucose , Glucose Oxidase/química , Oxigênio
3.
Respirology ; 27(1): 56-65, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34693587

RESUMO

BACKGROUND AND OBJECTIVE: Right ventricular (RV) volumes are crucial outcome determinants in pulmonary diseases. Little is known about the associations of RV volumes during hospitalized acute exacerbations of chronic obstructive pulmonary disease (AECOPD). We aimed to ascertain associations of RV end-diastolic volume indexed to body surface area (RVEDVI) during hospitalized AECOPD and its relationship with mortality in long-term follow-up. METHODS: This is a prospective observational cohort study (December 2013-November 2019, ACTRN12617001562369) using dynamic retrospective ECG-gated computed tomography during hospitalized AECOPD. RVEDVI was defined as normal or high using Framingham Offspring Cohort values. Cox regression determined the prognostic relevance of RVEDVI for death. RESULTS: A total of 148 participants (70 ± 10 years [mean ± SD], 88 [59%] men) were included, of whom 75 (51%) had high RVEDVI. This was associated with more frequent hospital admissions in the 12 months before admission (52/75 [69%] vs. 38/73 [52%], p = 0.04) and higher breathlessness (modified Medical Research Council score, 2.9 ± 1.3 vs. 2.4 ± 1.2, p = 0.007). During follow-up, high RVEDVI was associated with greater mortality (log-rank p = 0.001). In univariable Cox regression, increasing RVEDVI was associated with higher mortality (hazard ratio [HR]: 1.02 per ml/m2 ; 95% CI: 1.01, 1.03; p = 0.001). In multivariable Cox regression, RVEDVI was independently associated with mortality (HR: 1.01 per ml/m2 ; 95% CI: 1.00, 1.03; p = 0.050) at a borderline significance level. Adding RVEDVI to three COPD mortality prediction systems improved model fit (pooled chi-square test [BODE: p = 0.05, ADO: p = 0.04, DOSE: p = 0.02]). CONCLUSION: In patients with hospitalized AECOPD, higher RV end-diastolic volume was associated with worse acute clinical parameters and greater mortality.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Tetralogia de Fallot , Humanos , Masculino , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Estudos Retrospectivos , Volume Sistólico
4.
Heart Lung Circ ; 31(8): 1102-1109, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35501246

RESUMO

BACKGROUND: Non-invasive computed tomography (CT)-derived fractional flow reserve (FFRCT) is computed from standard coronary CT angiography (CTA) datasets and provides accurate vessel-specific ischaemia assessment of coronary artery disease (CAD). To date, the technique and its diagnostic performance has not been verified in the Australian clinical context. The aim of this study was to describe and compare the diagnostic performance of FFRCT and CTA for the detection of vessel-specific ischaemia as determined by invasive fractional flow reserve (FFR) in the Australian patient population. METHODS: One-hundred-and-nine patients (219 vessels) referred for clinically mandated invasive angiography were retrospectively assessed. Each patient underwent research mandated CTA and FFRCT within 3 months of invasive angiography and invasive FFR assessment. Independent core laboratory assessments were made to determine visual CTA stenosis, FFRCT and invasive FFR values. FFRCT values were matched with the corresponding invasive FFR measurement taken at the given wire position. Visual CTA stenosis ≥50%, FFRCT values ≤0.8 and invasive FFR values ≤0.8 were considered significant for ischaemia. RESULTS: Per vessel accuracy, sensitivity, specificity, positive predictive value and negative predictive value of FFRCT were 80.4%, 80.0%, 80.6%, 64.9% and 90.0% respectively. Corresponding values for CTA were 75.1%, 87.1%, 69.2%, 58.1% and 91.7% respectively. In receiver operating characteristic curve analysis, FFRCT demonstrated superior area under the curve (AUC) compared with CTA in both per vessel (0.87 vs 0.77, p=0.004) and per patient analysis (0.86 vs 0.74, p=0.011). Per vessel AUC of combined CTA and FFRCT was superior to CTA alone (0.89 vs 0.77, p<0.0001). CONCLUSION: In this cohort of Australian patients, the diagnostic performance of FFRCT was found to be comparable to existing international literature, with demonstrated improvement in performance compared with CTA alone for the detection of vessel-specific ischaemia.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Austrália , Constrição Patológica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/métodos
5.
J Stroke Cerebrovasc Dis ; 30(10): 106009, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34343837

RESUMO

BACKGROUND: Intracranial atherosclerosis is a common cause of stroke with a high recurrence rate. Haemodynamically significant lesions are associated with a particularly high risk of recurrence. Computational fluid dynamics (CFD) is a tool that has been investigated to identify haemodynamically significant lesions. CFD in the intracranial vasculature benefits from the precedent set by cardiology, where CFD is an established clinical tool. This precedent is particularly important in CFD as models are very heterogenous. There are many decisions-points in the model-creation process, usually involving a trade-off between computational expense and accuracy. OBJECTIVES: This study aimed to review published CFD models in intracranial atherosclerosis and compare them to those used in cardiology. METHODS: A systematic search for all published computational fluid dynamics models applied to intracranial atherosclerosis was performed. Each study was analysed as regards to the different steps in creating a fluid dynamics model and findings were compared with established cardiology CFD models. RESULTS AND CONCLUSION: 38 papers were screened and 12 were included in the final analysis. There were important differences between coronary and intracranial atherosclerosis models in the following areas: area of interest segmented, use of transient models vs steady-state models, boundary conditions, methods for solving the fluid dynamics equations and validation. These differences may be high-yield areas to explore for future research.


Assuntos
Angiografia Cerebral , Artérias Cerebrais/diagnóstico por imagem , Circulação Cerebrovascular , Angiografia por Tomografia Computadorizada , Arteriosclerose Intracraniana/diagnóstico por imagem , Angiografia por Ressonância Magnética , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Artérias Cerebrais/fisiopatologia , Hemodinâmica , Humanos , Hidrodinâmica , Arteriosclerose Intracraniana/fisiopatologia , Valor Preditivo dos Testes , Prognóstico , Interpretação de Imagem Radiográfica Assistida por Computador
6.
Radiology ; 292(2): 343-351, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31184558

RESUMO

Background Coronary CT angiography with noninvasive fractional flow reserve (FFR) predicts lesion-specific ischemia when compared with invasive FFR. The longer term prognostic value of CT-derived FFR (FFRCT) is unknown. Purpose To determine the prognostic value of FFRCT when compared with coronary CT angiography and describe the relationship of the numeric value of FFRCT with outcomes. Materials and Methods This prospective subanalysis of the NXT study (Clinicaltrials.gov: NCT01757678) evaluated participants suspected of having stable coronary artery disease who were referred for invasive angiography and who underwent FFR, coronary CT angiography, and FFRCT. The incidence of the composite primary end point of death, myocardial infarction, and any revascularization and the composite secondary end point of major adverse cardiac events (MACE: cardiac death, myocardial infarction, unplanned revascularization) were compared for an FFRCT of 0.8 or less versus stenosis of 50% or greater on coronary CT angiograms, with treating physicians blinded to the FFRCT result. Results Long-term outcomes were obtained in 206 individuals (age, 64 years ± 9.5), including 64% men. At median follow-up of 4.7 years, there were no cardiac deaths or myocardial infarctions in participants with normal FFRCT. The incidence of the primary end point was more frequent in participants with positive FFRCT compared with clinically significant stenosis at coronary CT angiography (73.4% [80 of 109] vs 48.7% [91 of 187], respectively; P < .001), with the majority of outcomes being planned revascularization. Corresponding hazard ratios (HRs) were 9.2 (95% confidence interval [CI]: 5.1, 17; P < .001) for FFRCT and 5.9 (95% CI: 1.5, 24; P = .01) for coronary CT angiography. FFRCT was a superior predictor compared with coronary CT angiography for primary end point (C-index FFRCT, 0.76 vs coronary CT angiography, 0.54; P < .001) and MACE (FFRCT, 0.71 vs coronary CT angiography, 0.52; P = .001). Frequency of MACE was higher in participants with positive FFRCT compared with coronary CT angiography (15.6% [17 of 109] vs 10.2% [19 of 187], respectively; P = .02), driven by unplanned revascularization. MACE HR was 5.5 (95% CI: 1.6, 19; P = .006) for FFRCT and 2.0 (95% CI: 0.3, 14; P = .46) for coronary CT angiography. Each 0.05-unit FFRCT reduction was independently associated with greater incidence of primary end point (HR, 1.7; 95% CI: 1.4, 1.9; P < .001) and MACE (HR, 1.4; 95% CI: 1.1, 1.8; P < .001). Conclusion In stable patients referred for invasive angiography, a CT-derived fractional flow reserve (FFRCT) value of 0.8 or less was a predictor of long-term outcomes driven by planned and unplanned revascularization and was superior to clinically significant stenosis on coronary CT angiograms. Additionally, the numeric value of FFRCT was an independent predictor of outcomes. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Dennie and Rubens in this issue.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença
7.
Med J Aust ; 210(9): 417-423, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30907000

RESUMO

Chronic obstructive pulmonary disease (COPD) and cardiovascular disease (CVD) frequently coexist but combined disease is often not recognised. Since symptoms overlap significantly, it is common for patients' presentations to be attributed to one disease alone, and for the other to be overlooked. The effect of COPD and CVD goes beyond the shared risk factors of smoking and advancing age. The presence of COPD adversely affects cardiac disease and vice versa. In comparison to individuals with one disease alone, those with both conditions have a higher mortality rate, experience more frequent exacerbations with more hospitalisations and have worse quality of life. More patients with mild and moderate COPD die from CVD than from COPD, and there is a higher rate of arrhythmias, particularly atrial fibrillation. Accurate and timely diagnosis is therefore crucial. Retrospective evidence indicates that individuals with COPD and CVD may have better outcomes with appropriate CVD pharmacotherapy, yet robust prospective evidence is lacking. Inhaled medications for patients with stable COPD improve quality of life and reduce exacerbations, but there is limited evidence that they reduce mortality. A low threshold for investigation and treatment of CVD in COPD and COPD in CVD is essential.


Assuntos
Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/terapia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/terapia , Administração por Inalação , Broncodilatadores/administração & dosagem , Comorbidade , Humanos , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco
8.
Intern Med J ; 48 Suppl 2: 5-13, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29388307

RESUMO

Several BCR-ABL1 tyrosine kinase inhibitors (TKIs) are approved for the first-line treatment of chronic phase chronic myeloid leukaemia (CML). Disease control is achieved in the vast majority of patients and disease-specific survival is excellent. Consequently, there is now emphasis on managing comorbidities and minimising treatment-related toxicity. Second-generation TKIs have cardiovascular risks that are greater than with imatinib treatment, but these risks must be balanced against the superior CML responses encountered with more potent TKIs. Cardiovascular risk should be assessed at baseline using a locally validated model based on the Framingham risk equation. Clinicians involved in the care of CML patients should be aware of the vascular complications of TKIs and manage cardiovascular risk factors early to mitigate treatment-related risks. Reversible risk factors, such as dyslipidaemia, smoking, diabetes and hypertension, should be addressed. We summarise the available data on cardiovascular complications in CML patients treated with TKIs. Using the latest evidence and collective expert opinion, we provide practical advice for clinicians to assess, stratify and manage cardiovascular risk in people with CML receiving TKI therapy.


Assuntos
Antineoplásicos/uso terapêutico , Doenças Cardiovasculares/prevenção & controle , Gerenciamento Clínico , Leucemia Mielogênica Crônica BCR-ABL Positiva/tratamento farmacológico , Inibidores de Proteínas Quinases/uso terapêutico , Proteínas Tirosina Quinases/antagonistas & inibidores , Antineoplásicos/farmacologia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/metabolismo , Ensaios Clínicos como Assunto/métodos , Humanos , Leucemia Mielogênica Crônica BCR-ABL Positiva/diagnóstico , Leucemia Mielogênica Crônica BCR-ABL Positiva/metabolismo , Inibidores de Proteínas Quinases/farmacologia , Proteínas Tirosina Quinases/metabolismo
9.
Eur Heart J ; 37(15): 1220-7, 2016 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-26763790

RESUMO

AIMS: Coronary plaque characteristics are associated with ischaemia. Differences in plaque volumes and composition may explain the discordance between coronary stenosis severity and ischaemia. We evaluated the association between coronary stenosis severity, plaque characteristics, coronary computed tomography angiography (CTA)-derived fractional flow reserve (FFRCT), and lesion-specific ischaemia identified by FFR in a substudy of the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). METHODS AND RESULTS: Coronary CTA stenosis, plaque volumes, FFRCT, and FFR were assessed in 484 vessels from 254 patients. Stenosis >50% was considered obstructive. Plaque volumes (non-calcified plaque [NCP], low-density NCP [LD-NCP], and calcified plaque [CP]) were quantified using semi-automated software. Optimal thresholds of quantitative plaque variables were defined by area under the receiver-operating characteristics curve (AUC) analysis. Ischaemia was defined by FFR or FFRCT ≤0.80. Plaque volumes were inversely related to FFR irrespective of stenosis severity. Relative risk (95% confidence interval) for prediction of ischaemia for stenosis >50%, NCP ≥185 mm(3), LD-NCP ≥30 mm(3), CP ≥9 mm(3), and FFRCT ≤0.80 were 5.0 (3.0-8.3), 3.7 (2.4-5.6), 4.6 (2.9-7.4), 1.4 (1.0-2.0), and 13.6 (8.4-21.9), respectively. Low-density NCP predicted ischaemia independent of other plaque characteristics. Low-density NCP and FFRCT yielded diagnostic improvement over stenosis assessment with AUCs increasing from 0.71 by stenosis >50% to 0.79 and 0.90 when adding LD-NCP ≥30 mm(3) and LD-NCP ≥30 mm(3) + FFRCT ≤0.80, respectively. CONCLUSION: Stenosis severity, plaque characteristics, and FFRCT predict lesion-specific ischaemia. Plaque assessment and FFRCT provide improved discrimination of ischaemia compared with stenosis assessment alone.


Assuntos
Isquemia Miocárdica/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Placa Aterosclerótica/fisiopatologia , Remodelação Ventricular/fisiologia
10.
Radiology ; 279(1): 75-83, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26444662

RESUMO

PURPOSE: To compare the diagnostic performance of 320-detector row computed tomography (CT) coronary angiography-derived computed fractional flow reserve (FFR; FFRCT), transluminal attenuation gradient (TAG; TAG320), and CT coronary angiography alone to diagnose hemodynamically significant stenosis as determined by invasive FFR. MATERIALS AND METHODS: This substudy of the prospective NXT study (no. NCT01757678) was approved by each participating institution's review board, and informed consent was obtained from all participants. Fifty-one consecutive patients who underwent 320-detector row CT coronary angiographic examination and invasive coronary angiography with FFR measurement were included. Independent core laboratories determined coronary artery disease severity by using CT coronary angiography, TAG320, FFRCT, and FFR. TAG320 is defined as the linear regression coefficient between luminal attenuation and axial distance from the coronary ostium. FFRCT was computed from CT coronary angiography data by using computational fluid dynamics technology. Diagnostic performance was evaluated and compared on a per-vessel basis by the area under the receiver operating characteristic (ROC) curve (AUC). RESULTS: Among 82 vessels, 24 lesions (29%) had ischemia by FFR (FFR ≤ 0.80). FFRCT exhibited a stronger correlation with invasive FFR compared with TAG320 (Spearman ρ, 0.78 vs 0.47, respectively). Overall per-vessel accuracy, sensitivity, specificity, and positive and negative predictive values for TAG320 (<15.37) were 78%, 58%, 86%, 64%, and 83%, respectively; and those of FFRCT were 83%, 92%, 79%, 65%, and 96%, respectively. ROC curve analysis showed a significantly larger AUC for FFRCT (0.93) compared with that for TAG320 (0.72; P = .003) and CT coronary angiography alone (0.68; P = .008). CONCLUSION: FFRCT computed from 320-detector row CT coronary angiography provides better diagnostic performance for the diagnosis of hemodynamically significant coronary stenoses compared with CT coronary angiography and TAG320.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Humanos , Iohexol , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
11.
Radiology ; 276(1): 91-101, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25710278

RESUMO

PURPOSE: To identify computed tomographic (CT) coronary indexes independently associated with a fractional flow reserve (FFR) of 0.8 or less, to derive a score that combines CT indexes most predictive of an FFR of 0.8 or less, and to evaluate the diagnostic accuracy of the score in predicting an FFR of 0.8 or less. MATERIALS AND METHODS: This retrospective study had institutional review board approval and waiver of the need to obtain informed consent. Consecutive patients who underwent CT coronary angiography and FFR assessment with one or more discrete lesion(s) of intermediate (30%-70%) severity at CT were included. Quantitative CT measurements were performed by using dedicated software. The CT indexes evaluated included the following: plaque burden, minimal luminal area and diameter, stenosis diameter, area of stenosis, lesion length, remodeling index, plaque morphology, calcification severity, and the Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) score, which approximates the size of the myocardium subtended by a lesion. By using covariates independently associated with an FFR of 0.8 or less, a score was determined on the basis of modified Akaike information criteria, and the C statistics of individual and combined indexes were compared. RESULTS: Eighty-five patients (mean age, 64.2 years; range, 48-88 years; 65.9% men; 124 lesions; 38 lesions with an FFR ≤ 0.8) were included. Area of stenosis, lesion length, and APPROACH score were the strongest predictors of an FFR of 0.8 or less and were used to derive the ASLA score. The optimism-adjusted Harrell C statistic for the combined score was 0.82, which was superior to that for area of stenosis (0.74), lesion length (0.75), and the APPROACH score (0.71) (P < .001 for trend). The corresponding incremental discrimination improvement indexes were 0.17, 0.11, and 0.19, respectively (P < .001 for all), suggesting that the score improves reclassification compared with any one angiographic index. The average time required for score derivation was 102.6 seconds. CONCLUSION: The ASLA score, which accounts for CT-derived area of stenosis, lesion length, and APPROACH score, may conveniently improve the prediction, beyond individual indexes, of functionally significant intermediate coronary lesions.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença
12.
Am Heart J ; 169(4): 564-71.e4, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25819864

RESUMO

BACKGROUND: Angiographic evaluation of diameter stenosis has modest predictive value for functionally significant coronary artery stenoses as assessed by fractional flow reserve (FFR). Lesion length and assessment of area of myocardium at risk (Bypass Angioplasty Revascularization Investigation [BARI] Myocardial Jeopardy Index [MJI]) subtended by the stenotic coronary arteries are also predictors of functionally significant coronary artery stenoses. We sort to assess the diagnostic accuracy of DILEMMA score, which combines minimal lumen diameter (MLD), lesion length, and BARI MJI in prediction of significantly reduced FFR (≤0.8). METHODS: We assessed patients who underwent coronary angiography and FFR. Lesion length and MLD were assessed by quantitative coronary angiography. Estimation of area of myocardium at risk subtended by coronary stenoses was performed using the BARI MJI. RESULTS: A total of 296 patients (age 64 ± 10.6 years, 68% male, 497 vessels) were included. DILEMMA score was significantly higher in vessels with significant FFR, 6.09 ± 3.23 versus 3.84 ± 2.99 (P < .001). In the derivation cohort, the optimism-adjusted Harrell c statistic for DILEMMA score was 0.82 compared with 0.76 for BARI MJI, 0.75 for lesion length, and 0.7 for MLD. In the validation cohort, the c-statistic for DILEMMA score, BARI MJI, lesion length, and MLD was 0.88, 0.77, 0.81, and 0.72, respectively. The DILEMMA score was a better predictor of FFR ≤0.8 compared with MLD, lesion length, and BARI MJI individually (P < .001, P < .02, and P < .045, respectively) on Bonferroni-adjusted pairwise comparison. CONCLUSIONS: DILEMMA score, taking into account MLD, lesion length, and BARI MJI, may have incremental predictive value beyond the individual indices alone for detecting functionally significant coronary artery stenoses.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
13.
Eur Radiol ; 24(3): 738-47, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24217643

RESUMO

OBJECTIVES: To determine the accuracy of 320-row multidetector coronary computed tomography angiography (M320-CCTA) to detect functional stenoses using fractional flow reserve (FFR) as the reference standard and to predict revascularisation in stable coronary artery disease. METHODS: One hundred and fifteen patients (230 vessels) underwent M320-CCTA and FFR assessment and were followed for 18 months. Diameter stenosis on invasive angiography (ICA) and M320-CCTA were assessed by consensus by two observers and significant stenosis was defined as ≥50%. FFR ≤0.8 indicated functionally significant stenoses. RESULTS: M320-CCTA had 94% sensitivity and 94% negative predictive value (NPV) for FFR ≤0.8. Overall accuracy was 70%, specificity 54% and positive predictive value 65%. On receiver operating characteristic (ROC) curve analysis, the area under the curve (AUC) for CCTA to predict FFR ≤0.8 was 0.74 which was comparable with ICA. The absence of a significant stenosis on M320-CCTA was associated with a 6% revascularisation rate. M320-CCTA predicted revascularisation with an AUC of 0.71 which was comparable with ICA. CONCLUSIONS: M320-CCTA has excellent sensitivity and NPV for functional stenoses and therefore may act as an effective gatekeeper to defer ICA and revascularisation. Like ICA, M320-CCTA lacks specificity for functional stenoses and only has moderate accuracy to predict the need for revascularisation. KEY POINTS: • Important information about the heart is provided by 320-row multidetector CT coronary angiography (M320-CCTA). • M320-CCTA accurately detects and excludes functional stenoses determined by fractional flow reserve (FFR). • Non-significant stenoses on M320-CCTA associated with fewer cardiac events and less revascularisation. • M320-CCTA may act as a gatekeeper for invasive angiography and inappropriate revascularisation. • Like ICA, M320-CCTA only has moderate accuracy to predict vessels requiring revascularisation.


Assuntos
Angiografia Coronária/normas , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada Multidetectores/normas , Idoso , Angina Pectoris/diagnóstico por imagem , Área Sob a Curva , Angiografia Coronária/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
15.
Eur Radiol ; 23(7): 1812-21, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23430194

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). METHODS: Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. RESULTS: All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). CONCLUSIONS: Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. KEY POINTS: • Advances in CT technology provides comprehensive anatomical and functional cardiac information. • Combined 320-detector CTA/adenosine-stress CTP is feasible with excellent image quality. • Combined CTA/CTP is accurate in identifying myocardial ischaemia compared with QCA/SPECT-MPI. • Combined CTA/CTP results in lower patient radiation exposure than SPECT-MPI. • CTA/CTP may become an established imaging technique for suspected CAD.


Assuntos
Adenosina , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/patologia , Feminino , Taxa de Filtração Glomerular , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Perfusão , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos
16.
Eur Heart J ; 33(1): 67-77, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21810860

RESUMO

AIMS: Adenosine stress computed tomography myocardial perfusion imaging (CTP) is an emerging non-invasive method for detecting myocardial ischaemia. Its value when compared with fractional flow reserve (FFR), a highly accurate index of ischaemia, is unknown. Our aim was to determine the diagnostic accuracy of CTP and its incremental value when used with computed tomography coronary angiography (CTA) for detecting ischaemia compared with FFR. METHODS AND RESULTS: Forty-two patients (126 vessel territories), who had at least one ≥50% angiographic stenosis on invasive angiography considered for non-urgent revascularization, were included and underwent FFR and CT assessment, including CTP, delayed contrast enhancement scan and CTA all acquired using 320-detector row CT, and prospective ECG gating. Fractional flow reserve was determined in 86 territories subtended by vessels with ≥50% stenosis upon visual assessment. Fractional flow reserve ≤0.8 was considered to indicate significant ischaemia. Computed tomography myocardial perfusion imaging correctly identified 31/41 (76%) ischaemic territories and 38/45 (84%) non-ischaemic territories. Per-vessel territory sensitivity, specificity, positive, and negative predictive values of CTP were 76, 84, 82, and 79%, respectively. The combination of a ≥50% stenosis on CTA and perfusion defect on CTP was 98% specific for ischaemia, while the presence of <50% stenosis on CTA and normal perfusion on CTP was 100% specific for exclusion of ischaemia. Mean radiation for CTP and combined CT was 5.3 and 11.3 mSv, respectively. CONCLUSION: Computed tomography myocardial perfusion imaging is moderately accurate in identifying perfusion defects associated with ischaemia as assessed by FFR in patients considered for revascularization. In territories, where CTA and CTP are concordant, CTA/CTP is highly accurate in the detection and exclusion of ischaemia. This is achievable with acceptable radiation exposure using 320-detector row CT and prospective ECG gating.


Assuntos
Reserva Fracionada de Fluxo Miocárdico/fisiologia , Isquemia Miocárdica/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Adenosina , Idoso , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Revascularização Miocárdica/métodos , Variações Dependentes do Observador , Estudos Prospectivos , Sensibilidade e Especificidade , Vasodilatadores
17.
J Mater Chem B ; 10(32): 6118-6132, 2022 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-35916077

RESUMO

Glucose biosensors that could be subcutaneously injected and interrogated without a physically connected electrode and transmitter affixed to skin would represent a major advancement in reducing the user burden of continuous glucose monitors (CGMs). Towards this goal, an optical glucose biosensor was formed by strategically tailoring a thermoresponsive double network (DN) membrane to house a phosphorescence lifetime-based glucose sensing assay. This membrane was selected based on its potential to exhibit reduced biofouling via 'self-cleaning' due to cyclical deswelling/reswelling in vivo. The membrane was strategically tailored to incorporate oxygen-sensitive metalloporphyrin phosphor, Pd meso-tetra(sulfophenyl)-tetrabenzoporphyrin ([PdPh4(SO3Na)4TBP]3) (HULK) and glucose oxidase (GOx). Specifically, electrostatic interactions and colvalent bonds were used to stabilize HULK and GOx within the membrane, respectively. Enhancing the oxygen permeability of the membrane was necessary to achieve sensitivity of HULK/GOx to physiological glucose levels. Thus, silicone microparticles were incorporated at two concentrations. Key properties of SiHy-0.25 and SiHy-0.5 microparticle-containing compositions were compared to a control having no microparticles (SiHy-0). The discrete nature of the silicone microparticles maintained the desired thermosensitivity profile and did not impact water content. While the modulus decreased with silicone microparticle content, membranes were more mechanically robust versus a conventional hydrogel. SiHy-0.25, owing to apparent phase separation, displayed greater glucose diffusion and oxygen permeability versus SiHy-0.5. Furthermore, SiHy-0.25 biosensors exhibited the greatest glucose sensitivity range of 100 to 300 mg dL-1versus only 100 to 150 mg dL-1 for both SiHy-0 and SiHy-0.5 biosensors.


Assuntos
Técnicas Biossensoriais , Glucose , Glucose Oxidase/química , Oxigênio , Silicones
18.
Heart ; 108(3): 194-202, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34686567

RESUMO

OBJECTIVES: To obtain more powerful assessment of the prognostic value of fractional flow reserveCT testing we performed a systematic literature review and collaborative meta-analysis of studies that assessed clinical outcomes of CT-derived calculation of FFR (FFRCT) (HeartFlow) analysis in patients with stable coronary artery disease (CAD). METHODS: We searched PubMed and Web of Science electronic databases for published studies that evaluated clinical outcomes following fractional flow reserveCT testing between 1 January 2010 and 31 December 2020. The primary endpoint was defined as 'all-cause mortality (ACM) or myocardial infarction (MI)' at 12-month follow-up. Exploratory analyses were performed using major adverse cardiovascular events (MACEs, ACM+MI+unplanned revascularisation), ACM, MI, spontaneous MI or unplanned (>3 months) revascularisation as the endpoint. RESULTS: Five studies were identified including a total of 5460 patients eligible for meta-analyses. The primary endpoint occurred in 60 (1.1%) patients, 0.6% (13/2126) with FFRCT>0.80% and 1.4% (47/3334) with FFRCT ≤0.80 (relative risk (RR) 2.31 (95% CI 1.29 to 4.13), p=0.005). Likewise, MACE, MI, spontaneous MI or unplanned revascularisation occurred more frequently in patients with FFRCT ≤0.80 versus patients with FFRCT >0.80. Each 0.10-unit FFRCT reduction was associated with a greater risk of the primary endpoint (RR 1.67 (95% CI 1.47 to 1.87), p<0.001). CONCLUSIONS: The 12-month outcomes in patients with stable CAD show low rates of events in those with a negative FFRCT result, and lower risk of an unfavourable outcome in patients with a negative test result compared with patients with a positive test result. Moreover, the FFRCT numerical value was inversely associated with outcomes.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Prognóstico , Tomografia Computadorizada por Raios X
19.
Med J Aust ; 194(4): 186-9, 2011 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-21401459

RESUMO

Computed tomography coronary angiography is the most reliable diagnostic test for coronary atherosclerosis. Stress testing should be reserved for diagnosis of myocardial ischaemia. Revascularisation, either by stenting or bypass grafts, is commonly performed in patients with stable coronary artery disease but is a double-edged sword. In the presence of ischaemia, revascularisation improves outcomes; in its absence, outcomes are worsened. In current practice, the decision of whether to revascularise is mainly made on the basis of the angiographic appearance of the coronary lesion in question. Physiological assessment of coronary lesions by the use of a pressure wire and measurement of fractional flow reserve (FFR) often shows that lesions thought to be sufficiently severe to warrant stenting or bypass do not cause ischaemia. A recent randomised study has shown that using FFR measurements to guide coronary stenting resulted in a lower use of stents, decreased costs and superior outcomes at 2 years, compared with traditional angiographic assessment alone. We believe that changes to the methods of health reimbursement are needed in both the public and private health systems, to facilitate greater use of FFR measurement.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Reserva Fracionada de Fluxo Miocárdico , Algoritmos , Angiografia Coronária/economia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/economia , Doença da Artéria Coronariana/fisiopatologia , Custos e Análise de Custo , Eletrocardiografia , Humanos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Revascularização Miocárdica/métodos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
Circ Cardiovasc Interv ; 14(1): e009586, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33322917

RESUMO

BACKGROUND: Coronary artery disease is common in patients with severe aortic stenosis. Computed tomography-derived fractional flow reserve (CT-FFR) is a clinically used modality for assessing coronary artery disease, however, its use has not been validated in patients with severe aortic stenosis. This study assesses the safety, feasibility, and validity of CT-FFR in patients with severe aortic stenosis. METHODS: Prospectively recruited patients underwent standard-protocol invasive FFR and coronary CT angiography (CTA). CTA images were analyzed by central core laboratory (HeartFlow, Inc) for independent evaluation of CT-FFR. CT-FFR data were compared with FFR (ischemia defined as FFR ≤0.80). RESULTS: Forty-two patients (68 vessels) underwent FFR and CTA; 39 patients (92.3%) and 60 vessels (88.2%) had interpretable CTA enabling CT-FFR computation. Mean age was 76.2±6.7 years (71.8% male). No patients incurred complications relating to premedication, CTA, or FFR protocol. Mean FFR and CT-FFR were 0.83±0.10 and 0.77±0.14, respectively. CT calcium score was 1373.3±1392.9 Agatston units. On per vessel analysis, there was positive correlation between FFR and CT-FFR (Pearson correlation coefficient, R=0.64, P<0.0001). Sensitivity, specificity, positive predictive value, and negative predictive values were 73.9%, 78.4%, 68.0%, and 82.9%, respectively, with 76.7% diagnostic accuracy. The area under the receiver-operating characteristic curve for CT-FFR was 0.83 (0.72-0.93, P<0.0001), which was higher than that of CTA and quantitative coronary angiography (P=0.01 and P<0.001, respectively). Bland-Altman plot showed mean bias between FFR and CT-FFR as 0.059±0.110. On per patient analysis, the sensitivity, specificity, positive predictive, and negative predictive values were 76.5%, 77.3%, 72.2%, and 81.0% with 76.9% diagnostic accuracy. The per patient area under the receiver-operating characteristic curve analysis was 0.81 (0.67-0.95, P<0.0001). CONCLUSIONS: CT-FFR is safe and feasible in patients with severe aortic stenosis. Our data suggests that the diagnostic accuracy of CT-FFR in this cohort potentially enables its use in clinical practice and provides the foundation for future research into the use of CT-FFR for coronary evaluation pre-aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Volume Sistólico , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda