Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 60(7)2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39064567

RESUMO

(1) Background and Objectives: Mitral regurgitation is a common valve disease requiring surgical repair. Even with satisfactory results, repair techniques may underlie subjectivity and variability and require long learning curves. A novel approach, the "Roman Arch" technique, may ease the technical burden. This study assessed an automated suturing device's feasibility and time efficiency for a proposed simplified technique. (2) Materials and Methods: Using the MiStitch™ and MiKnot™ devices (LSI Solutions, Inc., Victor, NY, USA), the suture pattern was performed in a cadaver model. Three surgeons with different expertise levels conducted the procedures. Repair and suture placement times were recorded and analyzed. (3) Results: The modified "Roman Arch" repair was completed on all ten human heart specimens with an average total repair time of 3:01 ± 00:59 min and a trend toward reduced times as experience increased. The study confirmed the technical feasibility with 90% of the attempts rated as rather satisfactory or very satisfactory. (4) Conclusions: The MiStitch™ system effectively facilitated the modified "Roman Arch" repair in an ex vivo setting, suggesting its potential to reduce the technical complexity of mitral valve repairs. Further studies are needed to confirm its efficacy and safety in clinical practice.


Assuntos
Insuficiência da Valva Mitral , Valva Mitral , Técnicas de Sutura , Humanos , Técnicas de Sutura/instrumentação , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Cadáver , Estudos de Viabilidade
2.
J Card Surg ; 37(6): 1728-1729, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35274777

RESUMO

A 79-year-old man was referred for urgent coronary artery bypass grafting. Contrast-enhanced computed tomography revealed an atypically nose-shaped contrast defect, which intraoperatively turned out to be an atheromatous plaque. Its preoperative detection allowed us to prevent an adverse cerebral event. This case highlights that a thorough preoperative work-up should ideally include a CT angiography, in patients where atherosclerotic changes are to be expected.


Assuntos
Doenças da Aorta , Aterosclerose , Placa Aterosclerótica , Idoso , Aorta/diagnóstico por imagem , Aorta/cirurgia , Doenças da Aorta/cirurgia , Ponte de Artéria Coronária/efeitos adversos , Humanos , Masculino , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/cirurgia
3.
J Card Surg ; 37(7): 1959-1966, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35385588

RESUMO

BACKGROUND: Aim of this study is to analyse the performances of Clinical Risk Score (CRS) and European System for Cardiac Operative Risk Evaluation (EuroSCORE)-II in isolated tricuspid surgery. METHODS: Three hundred and eighty-three patients (54 ± 16 year; 54% female) were enrolled. Receiver operating characteristic analysis was performed to evaluate the relationship between the true positive fraction of test results and the false-positive fraction for a procedure. RESULTS: Considering the 30-day mortality the area under the curve was 0.6 (95% confidence interval [CI] 0.50-0.72) for EuroSCORE II and 0.7 (95% CI 0.56-0.84) for CRS-score. The ratio of expected/observed mortality showed underestimation when considering EuroSCORE-II (min. 0.46-max. 0.6). At multivariate analysis, the CRS score (p = .005) was predictor of late cardiac death. CONCLUSION: We suggest using both scores to obtain a range of expected mortality. CRS to speculate on late survival.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Tricúspide , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Valva Tricúspide/cirurgia
4.
Circ Res ; 124(2): 243-255, 2019 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-30582450

RESUMO

RATIONALE: Endothelial colony forming cells (ECFCs) or late blood outgrowth endothelial cells can be isolated from human cord or peripheral blood, display properties of endothelial progenitors, home into ischemic tissues and support neovascularization in ischemic disease models. OBJECTIVE: To assess the functions of CYTL1 (cytokine-like 1), a factor we found preferentially produced by ECFCs, in regard of vessel formation. METHODS AND RESULTS: We show by transcriptomic analysis that ECFCs are distinguished from endothelial cells of the vessel wall by production of high amounts of CYTL1. Modulation of expression demonstrates that the factor confers increased angiogenic sprouting capabilities to ECFCs and can also trigger sprouting of mature endothelial cells. The data further display that CYTL1 can be induced by hypoxia and that it functions largely independent of VEGF-A (vascular endothelial growth factor-A). By recombinant production of CYTL1 we confirm that the peptide is indeed a strong proangiogenic factor and induces sprouting in cellular assays and functional vessel formation in animal models comparable to VEGF-A. Mass spectroscopy corroborates that CYTL1 is specifically O-glycosylated on 2 neighboring threonines in the C-terminal part and this modification is important for its proangiogenic bioactivity. Further analyses show that the factor does not upregulate proinflammatory genes and strongly induces several metallothionein genes encoding anti-inflammatory and antiapoptotic proteins. CONCLUSIONS: We conclude that CYTL1 can mediate proangiogenic functions ascribed to endothelial progenitors such as ECFCs in vivo and may be a candidate to support vessel formation and tissue regeneration in ischemic pathologies.


Assuntos
Proteínas Angiogênicas/metabolismo , Comunicação Autócrina , Proteínas Sanguíneas/metabolismo , Neovascularização da Córnea , Citocinas/metabolismo , Células Progenitoras Endoteliais/metabolismo , Células Endoteliais da Veia Umbilical Humana/metabolismo , Neovascularização Fisiológica , Comunicação Parácrina , Proteínas Angiogênicas/genética , Animais , Proteínas Sanguíneas/genética , Hipóxia Celular , Citocinas/genética , Modelos Animais de Doenças , Feminino , Glicosilação , Células HEK293 , Células Endoteliais da Veia Umbilical Humana/transplante , Humanos , Masculino , Camundongos Endogâmicos C57BL , Camundongos SCID , Via Secretória , Transdução de Sinais , Esferoides Celulares , Fator A de Crescimento do Endotélio Vascular/metabolismo
5.
Thorac Cardiovasc Surg ; 68(8): 669-673, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31491791

RESUMO

BACKGROUND: We previously identified preparation of the internal mammary artery as a risk factor significantly impairing antibiotic tissue penetration into the presternal subcutaneous tissue. We, therefore, adapted our dosing schema regarding preoperative timing to overcome this risk factor. METHODS: Eight patients who underwent coronary artery bypass grafting with a left internal mammary artery and vein grafts were included in this clinical trial. Cefazolin (4 g) was administered twice (3 hours and 1 hour) prior to skin incision and once during skin closure (2 g). Antibiotic concentrations were measured with subcutaneous microdialysis probes on both sternal sides. Results were directly compared with the previously published patient cohort receiving the standard schema (4 g cefazolin prior to skin incision and 2 g during closure). RESULTS: All patients (7 male, 1 female, 69 ± 7 years, 26.3 ± 3.9 kg/m2) survived the perioperative period. Mean area under the curve on the right and left sternal side was 117.0 ± 92.5 µg/mL and 114.5 ± 83.2 µg/mL, respectively (p = 0.95). This was well above the previously measured mean peak tissue concentrations without early preoperative antibiotic administration on the side of mammary artery harvesting (52.4 ± 48.5 µg/mL vs. 13.1 ± 5.8 µg/mL; p = 0.039). The %fT > minimal inhibitory concentration (MIC) for Staphylococcus epidermidis and Staphylococcus aureus during the first 10 hours in presternal tissue was ≥ 70% but did not differ compared with standard schema. CONCLUSIONS: Early, additional preoperative administration of cefazolin was able to significantly increase peak tissue concentrations during surgery compared with the standard protocol. No difference, however, could be achieved in the percentage of time during which the concentration exceeded the MIC.


Assuntos
Antibacterianos/administração & dosagem , Antibioticoprofilaxia , Cefazolina/administração & dosagem , Ponte de Artéria Coronária , Infecção da Ferida Cirúrgica/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/efeitos adversos , Antibacterianos/farmacocinética , Áustria , Cefazolina/efeitos adversos , Cefazolina/farmacocinética , Ponte de Artéria Coronária/efeitos adversos , Esquema de Medicação , Feminino , Humanos , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/microbiologia , Fatores de Tempo , Distribuição Tecidual , Resultado do Tratamento
6.
Arterioscler Thromb Vasc Biol ; 38(11): 2755-2762, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30354231

RESUMO

Objective- HO-1 (heme oxygenase-1) induction may prevent or reduce ischemia-reperfusion injury. We previously evaluated its in vivo induction after a single systemic administration of heme arginate in peripheral blood mononuclear cells. The current trial was designed to assess the pharmacological tissue induction of HO-1 in the human heart with heme arginate in vivo. Approach and Results- Patients planned for conventional aortic valve replacement received placebo (n=8), 1 mg/kg (n=7) or 3 mg/kg (n=9) heme arginate infused intravenously 24 hours before surgery. A biopsy of the right ventricle was performed directly before aortic cross-clamping and after cross-clamp release. In addition, the right atrial appendage was partially removed for analysis. HO-1 protein and mRNA concentrations were measured in tissue samples and in peripheral blood mononuclear cells before to and up to 72 hours after surgery. No study medication-related adverse events occurred. A strong, dose-dependent effect on myocardial HO-1 mRNA levels was observed (right ventricle: 7.9±5.0 versus 88.6±49.1 versus 203.6±148.7; P=0.002 and right atrium: 10.8±8.8 versus 229.8±173.1 versus 392.7±195.7; P=0.001). This was paralleled by a profound increase of HO-1 protein concentration in atrial tissue (8401±3889 versus 28 585±10 692 versus 29 022±8583; P<0.001). Surgery and heme arginate infusion significantly increased HO-1 mRNA concentration in peripheral blood mononuclear cells ( P<0.001). HO-1 induction led to a significant increase of postoperative carboxyhemoglobin (1.7% versus 1.4%; P=0.041). No effect on plasma HO-1 protein levels could be detected. Conclusions- Myocardial HO-1 mRNA and protein can be dose-dependently induced by heme arginate. Protective effects of this therapeutic strategy should be evaluated in upcoming clinical trials. Clinical Trial Registration- URL: http://www.clinicaltrials.gov . Unique identifier: NCT02314780.


Assuntos
Arginina/administração & dosagem , Arginina/farmacocinética , Heme Oxigenase-1/biossíntese , Heme/administração & dosagem , Heme/farmacocinética , Miocárdio/enzimologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Arginina/efeitos adversos , Áustria , Carboxihemoglobina/metabolismo , Relação Dose-Resposta a Droga , Método Duplo-Cego , Indução Enzimática , Estudos de Viabilidade , Feminino , Heme/efeitos adversos , Heme Oxigenase-1/genética , Humanos , Infusões Intravenosas , Leucócitos Mononucleares/enzimologia , Masculino , Pessoa de Meia-Idade , RNA Mensageiro/biossíntese , RNA Mensageiro/genética
7.
J Card Surg ; 34(10): 1140-1142, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31389639

RESUMO

Quadruple valve surgery represents a complex and rare surgical procedure, requiring a systematic and standardized approach. In this intervention, pulmonary valve replacement (PVR) in patients without pre-existing congenital heart disease represents a challenge and no large data have been reported yet. We hereby report a case of bioprosthetic PVR in an octogenarian within a quadruple valve procedure, illustrating our preferred technique of PVR with bioprosthetic implantation and right ventricular outflow tract reconstruction.


Assuntos
Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia , Humanos , Masculino , Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico , Doenças Raras , Reoperação
8.
J Reconstr Microsurg ; 34(1): 1-7, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28992646

RESUMO

BACKGROUND: Radical debridement and wound closure with vascularized flaps has become a standard procedure in the treatment of deep sternal wound infections. Negative pressure incision management systems have been proven to diminish wound infections after sternotomy. In this study, the utility of Prevena Incision Management System (KCI Licensing Inc.) was evaluated in obese patients who received unilateral pectoralis major flap for the treatment of deep sternal wound infections. METHODS: The outcome and wound-related complication rates of 19 obese patients (mean body mass index, 33.7) treated for deep sternal wound infection with pectoralis major muscle flap in combination with Prevena between 2011 and 2016 were compared with 28 obese patients treated with conventional wound dressing only between 2000 and 2010. RESULTS: In patients additionally treated with Prevena, significantly fewer surgical revisions due to wound-related complications were necessary as compared with patients who received conventional wound dressing (5.3 vs. 32.1%, p = 0.034). A significantly shorter ICU length of stay (median 0 vs. 3.5 days, p < 0.001) and a trend toward shorter length of hospitalization (median 14 vs. 19.5 days after pectoralis major flap) could be observed. CONCLUSION: The application of Prevena significantly reduced revision surgery rates in obese patients treated with unilateral pectoralis major flap for deep sternal wound infections.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Desbridamento/métodos , Tratamento de Ferimentos com Pressão Negativa , Músculos Peitorais/transplante , Reoperação , Esternotomia/métodos , Infecção da Ferida Cirúrgica/cirurgia , Idoso , Feminino , Humanos , Tempo de Internação , Masculino , Obesidade , Estudos Retrospectivos , Esterno/cirurgia , Retalhos Cirúrgicos , Infecção da Ferida Cirúrgica/terapia , Resultado do Tratamento
9.
Transpl Int ; 30(5): 510-518, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28186648

RESUMO

Heme oxygenase-1 (HO-1) catalyses the degradation of heme to biliverdin, free iron, and carbon monoxide. The promoter region contains a highly polymorphic (GT)n repeat, where shorter (GT)n repeat sequences are linked to higher transcriptional activity, which was shown to correlate with a cytoprotective effect. Higher HO-1 levels may protect from cardiac allograft vasculopathy. Cardiac allograft recipients transplanted between 1988 and 2012 were analyzed for the HO-1 (GT)n repeat polymorphism using PCR and DNA fragment analysis with capillary electrophoresis. A relation to cardiac allograft vasculopathy (CAV) was analyzed using Cox regression including common risk factors for CAV and the occurrence of rejection episodes as explanatory variables. A total of 344 patients were analyzed, of which 127 patients were positive for CAV (36.9%). In our multivariable Cox regression analysis, the short homozygous HO-1 (GT)n genotype with <27 repeats (S/S) revealed a higher risk for CAV (P = 0.032). Donor age (P = 0.001) and donor weight (P = 0.005) were significant predictors for CAV. A potential risk for CAV was associated with rejection episodes (P = 0.058) and history of smoking (P = 0.06). The recipient HO-1 (GT)n genotype may contribute to CAV development. This finding has to be evaluated in larger series including studies targeting the underlying disease mechanism.


Assuntos
Transplante de Coração/efeitos adversos , Heme Oxigenase-1/genética , Doenças Vasculares/genética , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polimorfismo Genético , Regiões Promotoras Genéticas , Fatores de Risco , Adulto Jovem
10.
J Heart Valve Dis ; 26(5): 592-594, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-29762930

RESUMO

Herein is presented the case of an 83-year-old male patient in cardiogenic shock with acute aortic regurgitation that occurred six years after aortic valve replacement (AVR) with a 23 mm Trifecta™ valve. Prosthesis endocarditis was initially suspected because of a floating structure attached to the aortic valve that was visible on echocardiography. Emergency redo-AVR surgery was performed, but no signs of endocarditis were found intraoperatively. Hence, cusp tearing of the implanted bioprosthesis was considered to be the reason for the severe aortic regurgitation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Efeitos Adversos de Longa Duração , Complicações Pós-Operatórias , Falha de Prótese , Reoperação/métodos , Choque Cardiogênico/etiologia , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Diagnóstico Diferencial , Ecocardiografia/métodos , Endocardite/diagnóstico , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/etiologia , Efeitos Adversos de Longa Duração/fisiopatologia , Efeitos Adversos de Longa Duração/cirurgia , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Resultado do Tratamento
11.
J Card Fail ; 20(2): 135-45, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24412522

RESUMO

BACKGROUND: Heart failure (HF) is a common and often fatal complication of myocardial infarction (MI). Glutathione S-transferase P1-1 (GSTP1) has antiapoptotic and antiinflammatory effects and is a specific serum marker in HF patients. However, its role in HF treatment is unknown. METHODS AND RESULTS: GSTP1 effect was examined in a rat MI-induced HF model. Magnetic resonance imaging was used to examine cardiac function. GSTP1 and tumor necrosis factor α receptor-associated factor 2 (TRAF2) mRNA and protein expression were elevated in failing myocardium, although GSTP-1 binding activity to TRAF2 was not changed versus control. HF was associated with higher active JNK1 and p38 protein expression but reduced GSTP-1 binding activity to JNK1 and p38. Recombinant GSTP1 inhibited JNK1 and p38 and enhanced its own binding activity to TRAF2 and JNK1 in vitro. In the HF model, single-dose GSTP1 treatment reduced infarct area, apoptosis, and the expression of JNK1, p38, nuclear factor κB, and proinflammatory cytokines and improved thinning ratio, cardiac index and output, stroke volume, ejection fraction, regional wall motion, and survival compared with control. CONCLUSIONS: GSTP1 application early after MI results in long-term beneficial structural and functional effects that prevent progression to HF. GSTP1 could be a novel adjunct myocardial salvage approach in patients after MI.


Assuntos
Cardiotônicos/administração & dosagem , Glutationa S-Transferase pi/administração & dosagem , Insuficiência Cardíaca/prevenção & controle , Infarto do Miocárdio/tratamento farmacológico , Animais , Células Cultivadas , Progressão da Doença , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/patologia , Ratos
12.
Bioengineering (Basel) ; 11(7)2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-39061748

RESUMO

Tricuspid regurgitation (TR) is a prevalent finding in echocardiography and in case of severe disease is associated with impaired patient outcome. Clover repair offers a surgical solution that can be applied for the treatment of primary and secondary TR. An ex vivo passive beating porcine heart model was created to test a modified clover technique using automated suturing devices and to compare this approach to standard ring annuloplasty. Secondary TR was induced in 10 porcine hearts and the backflow of fluid was assessed. The primary endpoint of this study was regurgitant volume measured in mL at the site right atrial cannula. The baseline regurgitation was 43.3 ± 10.8 mL. The mean regurgitant volume was significantly reduced after all repair procedures to 22.2 ± 5.9 mL with isolated ring annuloplasty, 12 ± 3.9 mL with the modified clover, and 7.6 ± 3.4 mL with the combined procedure (p < 0.0001). The modified clover technique shows how to effectively reduce TR in an ex vivo model. This method may be suitable to facilitate tricuspid repair, especially for totally endoscopic valve surgery.

13.
J Clin Med ; 13(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38892924

RESUMO

Objectives: Mitral valve repair is the current standard approach for mitral valve regurgitation. However, patients suffering from functional mitral regurgitation have a significant risk of recurrent regurgitation. Adjustable mitral rings may provide a solution for this adverse event. Methods: A single-center, first-in-man clinical study was performed on patients suffering from mitral valve regurgitation. Patients were implanted with the study ring and followed for six months. A balloon catheter can be inserted into the study ring frame at any time after implantation and inflated independently in the areas P1, P2, or P3, which reduces the anterior-posterior diameter. Results: Five patients (75.4 ± 6.1 years; EuroSCORE II 2.1 ± 0.9%; three female) were successfully implanted. Mechanisms of mitral regurgitation were prolapse of the P2-segment in three patients and annular dilation in two patients. Surgical implantation according to the protocol was feasible and is described herein. Median cardiopulmonary bypass time and cross clamp time were 105 (118; 195) and 94 (90; 151) min, respectively. The median intensive care unit stay was 2 (2; 3) days. No perioperative, 30-day, or 6-month mortality was observed, and the repair was stable without residual or recurrent regurgitation ≥ grade 2. All patients reached the primary endpoint without device-related morbidity. Conclusions: Successful implantation was completed in five patients without device-related adverse events. Ring implantation was safe and feasible for all patients. The opportunity of post-implant adjustment to improve leaflet coaptation is a promising new therapeutic strategy that is assessed in a phase II study.

14.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38913864

RESUMO

OBJECTIVES: Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain. METHODS: A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed. RESULTS: The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20-0.94, P = 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60-1.09, P = 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63-1.07, P = 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47-1.45, P = 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P = 0.032). CONCLUSIONS: Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis.


Assuntos
Valva Aórtica , Endocardite , Implante de Prótese de Valva Cardíaca , Técnicas de Sutura , Titânio , Humanos , Masculino , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Valva Aórtica/cirurgia , Endocardite/prevenção & controle , Técnicas de Sutura/instrumentação , Estudos Retrospectivos , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos
15.
Viruses ; 16(1)2024 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-38257821

RESUMO

Microvascular integrity is a critical factor in myocardial fluid homeostasis. The subtle equilibrium between capillary filtration and lymphatic fluid removal is disturbed during pathological processes leading to inflammation, but also in hypoxia or due to alterations in vascular perfusion and coagulability. The degradation of the glycocalyx as the main component of the endothelial filtration barrier as well as pericyte disintegration results in the accumulation of interstitial and intracellular water. Moreover, lymphatic dysfunction evokes an increase in metabolic waste products, cytokines and inflammatory cells in the interstitial space contributing to myocardial oedema formation. This leads to myocardial stiffness and impaired contractility, eventually resulting in cardiomyocyte apoptosis, myocardial remodelling and fibrosis. The following article reviews pathophysiological inflammatory processes leading to myocardial oedema including myocarditis, ischaemia-reperfusion injury and viral infections with a special focus on the pathomechanisms evoked by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. In addition, clinical implications including potential long-term effects due to viral persistence (long COVID), as well as treatment options, are discussed.


Assuntos
COVID-19 , Viroses , Humanos , COVID-19/complicações , Síndrome de COVID-19 Pós-Aguda , SARS-CoV-2 , Progressão da Doença , Edema
16.
Front Cardiovasc Med ; 11: 1363336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38322769

RESUMO

Objectives: To date, there is no evidence regarding the safety of automated titanium fastener compared with hand-tied knots for prosthesis fixation in infective endocarditis. Methods: Between January 2016 and December 2022, a total of 220 patients requiring surgery for infective endocarditis were included in this retrospective analysis. The primary study endpoint was re-endocarditis during follow-up. The secondary study endpoints included stroke onset, all-cause mortality, and a composite outcome of either re-endocarditis, stroke, or all-cause mortality during follow-up. Results: Suture-securing with an automated titanium fastener was performed in 114 (51.8%) patients, whereas the conventional technique of hand knot-tying was used in 106 (48.2%) patients. The risk of re-endocarditis was significantly lower in the automated titanium fastener group, as shown in a multivariable proportional competing risk regression model (adjusted sub-hazard ratio 0.33, 95% confidence interval 0.11-0.99, p = 0.048). The multivariable Cox proportional hazards regression analysis showed that the automated titanium fastener group was not associated with an increased risk of stroke-onset or attaining the composite outcome, respectively, (adjusted hazard ratio 0.54, 95% confidence interval 0.27-1.08, p = 0.082), (adjusted hazard ratio 0.65, 95% confidence interval 0.42-1.02, p = 0.061). Also, this group was not associated with an increased risk of all-cause mortality, as demonstrated in the multivariable Poisson regression analysis (adjusted incidence-rate ratio 1.42, 95% confidence interval 0.83-2.42, p = 0.202). Conclusions: The use of automated titanium fastener device seems to be safe for infective endocarditis. Analyses of larger cohorts are required.

17.
J Surg Res ; 185(1): 419-25, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23731688

RESUMO

BACKGROUND: Various techniques of orthotopic single lung transplantation in rats have been reported; however, their widespread use has been limited owing to the complexity of the procedure. We report a novel microsurgical lung transplantation model in rats with a high survival rate that can be performed by one surgeon alone. METHODS: A total of 90 left lung allografts were transplanted from Fischer to Wistar Kyoto rats. We developed a triple axis precision system to place and stabilize the vascular clips intrathoracically to clamp the bronchovascular structures, thereby avoiding interference with the heart and contralateral lung movement. A single-suture bronchial anastomosis technique and proximal cuffing approach for vascular anastomosis was used, rendering surgical assistance unnecessary. RESULTS: In our recent series, both short-term (12 h) and long-term (21 d) survival was 100%. The lungs showed excellent perfusion and ventilation immediately on transplantation. Blood gas samples drawn from the left pulmonary vein and the histologic sections revealed excellent graft function. The donor operation lasted 20 ± 2 min, donor left lung dissection required 20 ± 2 min, and implantation required 90 ± 5 min. CONCLUSIONS: The present innovative method of left orthotopic single lung transplantation can be performed by one experienced surgeon alone, with excellent results and a high degree of reproducibility.


Assuntos
Transplante de Pulmão/métodos , Microcirurgia/métodos , Complicações Pós-Operatórias/prevenção & controle , Toracotomia/métodos , Animais , Dissecação/métodos , Estimativa de Kaplan-Meier , Transplante de Pulmão/mortalidade , Transplante de Pulmão/normas , Masculino , Camundongos , Microcirurgia/mortalidade , Microcirurgia/normas , Modelos Animais , Ratos Endogâmicos F344 , Ratos Endogâmicos WKY , Reprodutibilidade dos Testes , Toracotomia/mortalidade , Toracotomia/normas
18.
Transpl Int ; 26(1): 34-41, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23145940

RESUMO

Cystic fibrosis (CF) is an inherited condition that leads to respiratory failure and is the third most common indication for adult bilateral lung transplantation (LuTX). In contrast to other lung diseases, the immune system of CF patients is up-regulated and we therefore hypothesized that these patients would benefit from induction therapy. In the current study, we investigated the impact of antithymocyte globulin (ATG) induction therapy in CF patients after LuTX. One hundred and forty six patients who underwent LuTX for CF at our centre between January 1999 and December 2010 were included in the study and retrospectively analysed. They were divided into two groups according to the immunosuppressive protocol: group-A (n = 103) with and group-B (n = 43) without induction therapy on top of the basic calcineurin inhibitor based triple immunosuppression with mycophenolate mofetil and steroids. Perioperative survival was significantly better in the ATG group, a benefit sustained for the entire follow-up. ATG induction resulted in a significantly lower incidence of acute rejections without an increase in infectious complications. Taken together, our results indicate that ATG induction therapy confers a significant survival benefit in CF patients undergoing LuTX and reduces rejection. We advocate the use of induction therapy in this patient cohort.


Assuntos
Fibrose Cística/cirurgia , Transplante de Pulmão/mortalidade , Adulto , Bronquiolite Obliterante/etiologia , Infecções por Citomegalovirus/etiologia , Feminino , Rejeição de Enxerto , Humanos , Transplante de Pulmão/efeitos adversos , Masculino
20.
Clin Anat ; 26(8): 1006-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23355323

RESUMO

A CT-scan of a 75-year-old patient showed an aneurysm of the descending aorta with a maximum diameter of 4.8 cm involving the left subclavian artery. Due to the fact that the patient had several comorbidities including a severe chronic obstructive pulmonary disease he was treated only conservatively. However, there were several interesting findings on the CT-scan: the branching pattern of the aortic arch revealed a left carotid artery arising as first side branch of the distal part of the ascending aorta. This vessel crosses the midline right in front of the trachea. Apart from that the patient did not have a brachiocephalic trunk: the right carotid artery arose as the first branch from the aortic arch and crossed the right subclavian artery anteriorly. Furthermore, the left subclavian seemed to arise from the descending aorta and not from the aortic arch.


Assuntos
Aorta Torácica/anormalidades , Idoso , Aorta Torácica/diagnóstico por imagem , Humanos , Masculino , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA