Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(12): 123507, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586932

RESUMO

A Ku-band (12-18 GHz) multichannel Doppler reflectometer (DR) has been developed in the GAMMA 10/potential control and divertor simulating experiment (PDX) tandem mirror device to improve the applicability of DR measurement for simultaneous monitoring of velocity of electron density turbulence at different locations. Our previous single-channel DR circuit has been replaced by the multichannel microwave system using a nonlinear transmission line based comb generator with heterodyne technique. The multichannel DR system has been installed in the central cell of GAMMA 10/PDX. Initial results of application to GAMMA 10/PDX plasma are presented, showing Doppler frequency shifts during an additional ion cyclotron resonance frequency heating and gas-puffing experiment.

2.
Rev Sci Instrum ; 93(11): 113518, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461466

RESUMO

Doppler-backscattering (DBS) has been used in several fusion plasma devices because it can measure the perpendicular velocity of electron density perturbation v⊥, the radial electric field Er, and the perpendicular wavenumber spectrum S(k⊥) with high wavenumber and spatial resolution. In particular, recently constructed frequency comb DBS systems enable observation of turbulent phenomena at multiple observation points in the radial direction. A dual-comb microwave DBS system has been developed for the large helical device plasma measurement. Since it is desirable to control the gain of each frequency-comb separately, a frequency-comb DBS system was developed with a function to adjust the gain of the scattered signal intensity of each channel separately. A correction processing method was also developed to correct the amplitude ratio and the phase difference between the in-phase and quadrature-phase signals of the scattered signals. As a result, the error in Doppler-shift estimation required to observe vertical velocity and the radial electric field was reduced, which enables more precise measurements.

3.
Rev Sci Instrum ; 92(3): 033515, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820074

RESUMO

The multipass Thomson scattering (MPTS) technique is one of the most useful methods for measuring low-electron-density plasmas. The MPTS system increases Thomson scattering (TS) signal intensities by integrating all multipass (MP) signals and improving the TS time resolution by analyzing each pass signal. The fully coaxial MPTS system developed in GAMMA 10/potential-control and diverter-simulator experiments has a polarization-based configuration with image-relaying optics. The MPTS system can enhance Thomson scattered signals for improving the measurement accuracy and megahertz-order time resolution. In this study, we develop a new MPTS system comprising a laser amplification system to obtain continuous MP signals. The laser amplification system can improve degraded laser power and return an amplified laser to the MP system. We obtain continuous MP signals from the laser amplification system by improving the laser beam profile adjuster in gas scattering experiments. Moreover, we demonstrate that more MP signals and stronger amplified MP signals can be achieved via multiple laser injections to the laser amplification system in the developed MP system comprising a laser amplification system.

4.
Rev Sci Instrum ; 92(5): 053506, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243319

RESUMO

In the GAMMA 10/PDX tandem mirror, plasma with strong ion-temperature anisotropy is produced by using the ion cyclotron range of frequency waves. This anisotropy of ion temperature causes several Alfvén-Ion-Cyclotron (AIC) waves to spontaneously excite in the frequency range just below the ion cyclotron frequency. In addition, difference-frequency (DF) waves are excited in the radial inner region of the plasma by wave-wave coupling among the AIC waves. The radial density profiles were measured at multi-axial positions using a frequency-modulation reflectometer with an axial array of microwave antennas, and an axial variation of the density was found to be significant. In addition, a relative phase difference of the DF wave between axially separated two points was first obtained by finely choosing the probing frequency of the reflectometers with a maximum coherence used as a measure, indicating that the DF wave is a propagating wave, while the pump AIC waves are standing waves in the axial region of measurement.

5.
Rev Sci Instrum ; 89(10): 10C102, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399870

RESUMO

The multi-pass Thomson scattering (MPTS) system is a useful technique for increasing the Thomson scattering (TS) signal intensities and improving the TS diagnostic time resolution. The MPTS system developed in GAMMA 10/PDX has a polarization-based configuration with an image relaying system. The MPTS system has been constructed for enhancing the Thomson scattered signals for the improvement of measurement accuracy and the megahertz sampling time resolution. However, in the normal MPTS system, the MPTS signal intensities decrease with the pass number because of the damping due to the optical components. Subsequently, we have developed a new MPTS system with the laser amplification system. The laser amplification system can improve the degraded laser power after six passes in the multi-pass system to the initial laser power. For the first time worldwide, we successfully obtained the continued multi-pass signals after the laser amplification system in the gas scattering experiments.

6.
Rev Sci Instrum ; 88(3): 033504, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372363

RESUMO

A two-channel microwave reflectometer system with fast microwave antenna switching capability was developed and applied to the GAMMA 10 tandem mirror device to study high-frequency small-amplitude fluctuations in a hot mirror plasma. The fast switching of the antennas is controlled using PIN diode switches, which offers the significant advantage of reducing the number of high-cost microwave components and digitizers with high bandwidths and large memory that are required to measure the spatiotemporal behavior of the high-frequency fluctuations. The use of two channels rather than one adds the important function of a simultaneous two-point measurement in either the radial direction or the direction of the antenna array to measure the phase profile of the fluctuations along with the normal amplitude profile. The density fluctuations measured using this system clearly showed the high-frequency coherent fluctuations that are associated with Alfvén-ion-cyclotron (AIC) waves in GAMMA 10. A correlation analysis applied to simultaneously measured density fluctuations showed that the phase component that was included in a reflected microwave provided both high coherence and a clear phase difference for the AIC waves, while the amplitude component showed neither significant coherence nor clear phase difference. The axial phase differences of the AIC waves measured inside the hot plasma confirmed the formation of a standing wave structure. The axial variation of the radial profiles was evaluated and a clear difference was found among the AIC waves for the first time, which would be a key to clarify the unknown boundary conditions of the AIC waves.

7.
Rev Sci Instrum ; 87(11): 11E730, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910340

RESUMO

We have developed an analysis method to improve the accuracies of electron temperature measurement by employing a fitting technique for the raw Thomson scattering (TS) signals. Least square fitting of the raw TS signals enabled reduction of the error in the electron temperature measurement. We applied the analysis method to a multi-pass (MP) TS system. Because the interval between the MPTS signals is very short, it is difficult to separately analyze each Thomson scattering signal intensity by using the raw signals. We used the fitting method to obtain the original TS scattering signals from the measured raw MPTS signals to obtain the electron temperatures in each pass.

8.
Rev Sci Instrum ; 87(11): 11E127, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910479

RESUMO

In conventional multichannel/imaging microwave diagnostics of interferometry, reflectometry, and electron cyclotron emission measurements, a local oscillator (LO) signal is commonly supplied to a receiver array via irradiation using LO optics. In this work, we present a 60-GHz interferometer with a new eight-channel receiver array, called a local oscillator integrated antenna array (LIA). An outstanding feature of LIA is that it incorporates a frequency quadrupler integrated circuit for LO supply to each channel. This enables simple and uniform LO supply to the receiver array using only a 15-GHz LO source and a coaxial cable transmission line instead of using an expensive 60-GHz source, LO optics, and a waveguide transmission line. The new interferometer system is first applied to measure electron line-averaged density inside the divertor simulation experimental module (D-module) on GAMMA 10/PDX tandem mirror device.

9.
Rev Sci Instrum ; 85(11): 11D411, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430174

RESUMO

We propose a new interferometer system for density profile measurements. This system produces multiple measurement chords by a leaky-wave antenna driven by multiple frequency inputs. The proposed system was validated in laboratory evaluation experiments. We confirmed that the interferometer generates a clear image of a Teflon plate as well as the phase shift corresponding to the plate thickness. In another experiment, we confirmed that quasi-optical mirrors can produce multiple measurement chords; however, the finite spot size of the probe beam degrades the sharpness of the resulting image.

10.
Rev Sci Instrum ; 85(11): 11D805, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430218

RESUMO

A new antenna array is proposed in order to improve the sensitivity and complexity of microwave imaging diagnostics systems such as a microwave imaging reflectometry, a microwave imaging interferometer, and an electron cyclotron emission imaging. The antenna array consists of five elements: a horn antenna, a waveguide-to-microstrip line transition, a mixer, a local oscillation (LO) module, and an intermediate frequency amplifier. By using an LO module, the LO optics can be removed, and the supplied LO power to each element can be equalized. We report details of the antenna array and characteristics of a prototype antenna array.

11.
Rev Sci Instrum ; 85(11): 11D801, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430214

RESUMO

A multi-pass Thomson scattering (TS) has the advantage of enhancing scattered signals. We constructed a multi-pass TS system for a polarisation-based system and an image relaying system modelled on the GAMMA 10 TS system. We undertook Raman scattering experiments both for the multi-pass setting and for checking the optical components. Moreover, we applied the system to the electron temperature measurements in the GAMMA 10 plasma for the first time. The integrated scattering signal was magnified by approximately three times by using the multi-pass TS system with four passes. The electron temperature measurement accuracy is improved by using this multi-pass system.

12.
Rev Sci Instrum ; 83(10): 10E310, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126970

RESUMO

A new interferometer is installed on the west anchor cell of the GAMMA 10 tandem mirror. In GAMMA 10, we have used a heterodyne-type interferometer with a 70-GHz IMPATT oscillator and a 150-MHz oscillator for frequency modulation. The new interferometer consists of a 17.5-GHz phase locked dielectric resonator oscillator and a 37.5-MHz temperature-compensated crystal oscillator, as well as frequency multipliers. The main motivation for the new interferometer using frequency multipliers is to achieve a stable and cost effective interferometer. Direct anchor heating experiments with new anchor ion cyclotron range of frequency antennas in both the west and the east anchor cells are carried out. Density increases in both anchor cells are clearly observed using the new interferometer.

13.
Rev Sci Instrum ; 83(10): 10E326, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126984

RESUMO

A novel configuration of the multi-pass Thomson scattering (TS) system is proposed to improve the time resolution and accuracy of electron temperature measurements by use of a polarization control technique. This configuration can realize a perfect coaxial multi-passing at each pass, and the number of round trips is not limited by the optical configuration. To confirm the feasibility of the new method, we installed this system in the GAMMA 10 plasma system. As a result, the integrated scattering signal of the double-pass configuration is about two times larger than that of the single-pass configuration. These results are in good agreement with the design.

14.
Rev Sci Instrum ; 83(10): 10E333, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126991

RESUMO

In the GAMMA 10 tandem mirror, the typical electron density is comparable to that of the peripheral plasma of torus-type fusion devices. Therefore, an effective method to increase Thomson scattering (TS) signals is required in order to improve signal quality. In GAMMA 10, the yttrium-aluminum-garnet (YAG)-TS system comprises a laser, incident optics, light collection optics, signal detection electronics, and a data recording system. We have been developing a multi-pass TS method for a polarization-based system based on the GAMMA 10 YAG TS. To evaluate the effectiveness of the polarization-based configuration, the multi-pass system was installed in the GAMMA 10 YAG-TS system, which is capable of double-pass scattering. We carried out a Rayleigh scattering experiment and applied this double-pass scattering system to the GAMMA 10 plasma. The integrated scattering signal was made about twice as large by the double-pass system.

15.
Phys Rev Lett ; 97(5): 055001, 2006 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-17026107

RESUMO

Off-axis electron-cyclotron heating in an axisymmetric barrier mirror produces a cylindrical layer with energetic electrons, which flow through the central cell and into the end region. The layer, producing a localized bumped ambipolar potential Phi(C), forms a strong shear of radial electric fields E(r) and peaked vorticity with the direction reversal of E(r)xB sheared flow near the Phi(C) peak. Intermittent vortexlike turbulent structures near the layer are suppressed in the central cell by this actively produced transverse energy-transport barrier; this results in T(e) and T(i) rises surrounded by the layer.

16.
Phys Rev Lett ; 94(8): 085002, 2005 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-15783899

RESUMO

Vortexlike turbulent structures in hot-ion mode plasmas with several keV are observed in the case with a radially produced weak shear of electric fields E(r). However, a strong E(r) shear formation due to a high ion-confining potential phi(c) production clears up these vortices together with plasma-confinement improvement and disappearance of both drift-wave and turbulencelike Fourier spectral signals. These findings are based on three-time progress in phi(c) in comparison to phi(c) attained 1992-2002. The significant advance of phi(c) is well extended in line with proposed potential-formation physics scalings.

17.
J Synchrotron Radiat ; 5(Pt 3): 874-6, 1998 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15263682

RESUMO

The extension of a new theory on the X-ray energy response of semiconductor detectors is carried out to characterize the X-ray response of a multichannel semiconductor detector fabricated on one silicon wafer. Recently, these multichannel detectors have been widely utilized for position-sensitive observations in various research fields, including synchrotron radiation research and fusion-plasma investigations. This article represents the verification of the physics essentials of a proposed theory on the X-ray response of semiconductor detectors. The three-dimensional charge-diffusion effects on the adjoining detector-channel signals are experimentally demonstrated at the Photon Factory for two types of multichannel detectors. These findings are conveniently applicable for measuring diffusion lengths for industrial requirements.

18.
J Synchrotron Radiat ; 5(Pt 3): 877-9, 1998 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15263683

RESUMO

On the basis of a new theory of semiconductor X-ray detector response, a new type of multilayer semiconductor detector was designed and developed for convenient energy analyses of intense incident X-ray flux in a cumulative-current mode. Another anticipated useful property of the developed detector is a drastic improvement in high-energy X-ray response ranging over several hundred eV. The formula for the quantum efficiency of multilayer semiconductor detectors and its physical interpretations are proposed and have been successfully verified by synchrotron radiation experiments at the Photon Factory. These detectors are useful for data analyses under strong radiation-field conditions, including fusion-plasma-emitting X-rays and energetic heavy-particle beams, without the use of high-bias applications.

19.
Phys Rev Lett ; 86(19): 4310-3, 2001 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-11328162

RESUMO

The main operations from 1979 to 2000 in the GAMMA 10 tandem-mirror, characterized in terms of the high-potential mode having kV-order plasma-confining potentials and the hot-ion mode yielding fusion neutrons with 10-20 keV bulk-ion temperatures, are summarized and generalized as a result of scalings of the formation and the effects of the potentials. The wide validity of potential-formation physics from Cohen's theory and the validity of the generalized Pastukhov's theory for the effects of thermal-barrier potentials on electron confinement are verified and consolidated through electron-energy balance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA