Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 34(8): 1364-1371, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37100199

RESUMO

PURPOSE: To evaluate recovery of platelet count after transjugular intrahepatic portosystemic shunt (TIPS) creation and patient factors predicting platelet recovery after TIPS creation. MATERIALS AND METHODS: Adults with cirrhosis who underwent TIPS creation at 9 U.S. hospitals from 2010 to 2015 were included in this retrospective analysis. Change in platelets from before TIPS to 4 months after TIPS creation was characterized. Logistic regression was used to assess factors associated with top quartile percentage platelet increase after TIPS. Subgroup analyses were performed among patients with a pre-TIPS platelet count of ≤50 ×109/L. RESULTS: A total of 601 patients were included. The median absolute change in platelets was 1 × 109/L (-26 × 109/L to 25 × 109/L). Patients with top quartile percent platelet increase experienced ≥32% platelet increase. In multivariable analysis, pre-TIPS platelet counts (odds ratio [OR], 0.97 per 109/L; 95% CI, 0.97-0.98), age (OR, 1.24 per 5 years; 95% CI, 1.10-1.39), and pre-TIPS model for end-stage liver disease (MELD) scores (OR, 1.06 per point; 95% CI, 1.02-1.09) were associated with top quartile (≥32%) platelet increase. Ninety-four (16%) patients had a platelet count of ≤50 × 109/L before TIPS. The median absolute platelet change was 14 × 109/L (2 × 109/L to 34 × 109/L). Fifty-four percent of patients in this subgroup were in the top quartile for platelet increase. In multivariable logistic regression, age (OR, 1.50 per 5 years; 95% CI, 1.11-2.02) was the only factor associated with top quartile platelet increase in this subgroup. CONCLUSIONS: TIPS creation did not result in significant platelet increase, except among patients with a platelet count of ≤50 × 109/L before TIPS. Lower pre-TIPS platelet counts, older age, and higher pre-TIPS MELD scores were associated with top quartile (≥32%) platelet increase in the entire cohort, whereas only older age was associated with this outcome in the patient subset with a pre-TIPS platelet count of ≤50 × 109/L.


Assuntos
Doença Hepática Terminal , Derivação Portossistêmica Transjugular Intra-Hepática , Adulto , Humanos , Pré-Escolar , Contagem de Plaquetas , Estudos Retrospectivos , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Índice de Gravidade de Doença , Cirrose Hepática/diagnóstico , Cirrose Hepática/cirurgia , Cirrose Hepática/complicações , Resultado do Tratamento
2.
Clin Gastroenterol Hepatol ; 20(8): 1636-1662.e36, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34274511

RESUMO

Complications of portal hypertension, including ascites, gastrointestinal bleeding, hepatic hydrothorax, and hepatic encephalopathy, are associated with significant morbidity and mortality. Despite few high-quality randomized controlled trials to guide therapeutic decisions, transjugular intrahepatic portosystemic shunt (TIPS) creation has emerged as a crucial therapeutic option to treat complications of portal hypertension. In North America, the decision to perform TIPS involves gastroenterologists, hepatologists, and interventional radiologists, but TIPS creation is performed by interventional radiologists. This is in contrast to other parts of the world where TIPS creation is performed primarily by hepatologists. Thus, the successful use of TIPS in North America is dependent on a multidisciplinary approach and technical expertise, so as to optimize outcomes. Recently, new procedural techniques, TIPS stent technology, and indications for TIPS have emerged. As a result, practices and outcomes vary greatly across institutions and significant knowledge gaps exist. In this consensus statement, the Advancing Liver Therapeutic Approaches group critically reviews the application of TIPS in the management of portal hypertension. Advancing Liver Therapeutic Approaches convened a multidisciplinary group of North American experts from hepatology, interventional radiology, transplant surgery, nephrology, cardiology, pulmonology, and hematology to critically review existing literature and develop practice-based recommendations for the use of TIPS in patients with any cause of portal hypertension in terms of candidate selection, procedural best practices and, post-TIPS management; and to develop areas of consensus for TIPS indications and the prevention of complications. Finally, future research directions are identified related to TIPS for the management of portal hypertension.


Assuntos
Varizes Esofágicas e Gástricas , Hipertensão Portal , Derivação Portossistêmica Transjugular Intra-Hepática , Ascite/etiologia , Varizes Esofágicas e Gástricas/complicações , Hemorragia Gastrointestinal/complicações , Hemorragia Gastrointestinal/cirurgia , Humanos , Hipertensão Portal/complicações , Hipertensão Portal/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Resultado do Tratamento
3.
Emerg Radiol ; 27(2): 115-126, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31925592

RESUMO

Intravenous (IV) contrast material is used extensively for CT and MRI scans done in emergency departments (ED). Its use is essential to make many critical diagnoses in ED patients. While adverse reactions can occur, newer research has added to our knowledge of IV contrast media tolerance and safety leading to improved and more liberal guidelines for intravenous contrast use. The updated information described in this review article indicates how intravenous contrast can be used safely in more patients, more expeditiously and with fewer precautions than with prior guidelines. This review article explains the basis for the new recommendations for intravenous contrast material use and describes indicated precautions and preparations to avoid adverse reactions for iodinated agents used for CT and gadolinium agents for MRI.


Assuntos
Meios de Contraste/administração & dosagem , Serviço Hospitalar de Emergência , Imageamento por Ressonância Magnética , Guias de Prática Clínica como Assunto , Tomografia Computadorizada por Raios X , Meios de Contraste/efeitos adversos , Hipersensibilidade a Drogas/etiologia , Hipersensibilidade a Drogas/prevenção & controle , Gadolínio/administração & dosagem , Gadolínio/efeitos adversos , Humanos , Injeções Intravenosas , Fatores de Risco , Gestão da Segurança
4.
J Vasc Interv Radiol ; 30(7): 1043-1047, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30772167

RESUMO

PURPOSE: To evaluate efficacy and safety of transjugular liver biopsy (TJLB) via the left hepatic vein in patients with left lobe-only liver transplants (LLOTs). MATERIALS AND METHODS: Retrospective review revealed 43 TJLBs performed in 26 patients with LLOTs (mean age 51.3 y; range, 18-73 y) between January 2009 and June 2016 at a single institution. A comparison group of 44 randomly selected TJLBs performed in 37 orthotopic whole liver transplant (OWLT) recipients (mean age 57.6 y; range, 35-74 y) during the same time period was evaluated. Patient demographics, type and age of transplant, technical success, adequacy of samples, number of portal tracts obtained, pathologic diagnosis, and complication rate were reviewed. RESULTS: Technical success was achieved in 98% (42/43) of LLOT procedures. TJLB failed in 1 patient with LLOT, in whom no patent hepatic veins were identified. Technical success was achieved in 100% (44/44) in the OWLT group. Mean (SD) number of needle passes was 4.12 (1.25) in the LLOT group vs 3.95 (1.28) in the OWLT group (P = .54). Mean (SD) specimen length was 1.16 (0.75) cm in the LLOT group vs 1.19 (0.58) cm in the OWLT group (P = .78). Mean (SD) number of portal tracts obtained in the LLOT group was 10.7 (5.26) vs 12.3 (4.68) in the OWLT group (P = .17). No major complications were observed in either group. CONCLUSIONS: TJLB in adult patients with LLOTs appears safe and feasible, with favorable rates of technical success and adequacy of sampling.


Assuntos
Biópsia por Agulha/métodos , Cateterismo Venoso Central/métodos , Veias Hepáticas , Biópsia Guiada por Imagem/métodos , Veias Jugulares , Transplante de Fígado , Complicações Pós-Operatórias/patologia , Adolescente , Adulto , Idoso , Angiografia Digital , Biópsia por Agulha/efeitos adversos , Cateterismo Venoso Central/efeitos adversos , Feminino , Veias Hepáticas/diagnóstico por imagem , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Veias Jugulares/diagnóstico por imagem , Transplante de Fígado/efeitos adversos , Masculino , Pessoa de Meia-Idade , Flebografia , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Radiografia Intervencionista , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Adulto Jovem
5.
J Vasc Interv Radiol ; 29(9): 1248-1253, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30061059

RESUMO

PURPOSE: To assess the effectiveness of disposable radiation-absorbing surgical drapes on operator radiation dose during transjugular liver biopsy (TJLB). MATERIALS AND METHODS: This dual-arm prospective, randomized study was conducted between May 2017 and January 2018 at a single institution. TJLB procedures (N = 62; patient age range, 19-80 y) were assigned at a 1:1 ratio to the use of radiation-absorbing surgical drapes or standard surgical draping. The primary outcome was cumulative radiation equivalent dose incident on the operator, as determined by an electronic personal dosimeter worn at the chest during each procedure. Cumulative kerma-area product (KAP), total fluoroscopy time, and total number of exposures used during each liver biopsy procedure were also determined. RESULTS: Mean radiation dose incident on the operator decreased by 56% with the use of radiation-absorbing drapes (37 µSv ± 35; range, 4-183 µSv) compared with standard draping (84 µSv ± 58; range, 11-220 µSv). Radiation incident on the patient was similar between groups, with no significant differences in mean KAP, total fluoroscopy time, and number of exposures acquired during the procedures. CONCLUSIONS: Use of disposable radiation-absorbing drapes reduces scatter radiation to interventionalists performing TJLB.


Assuntos
Biópsia Guiada por Imagem/instrumentação , Hepatopatias/diagnóstico por imagem , Exposição Ocupacional/prevenção & controle , Saúde Ocupacional , Exposição à Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Radiografia Intervencionista/instrumentação , Radiologistas , Campos Cirúrgicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Equipamentos Descartáveis , Feminino , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Projetos Piloto , Estudos Prospectivos , Fatores de Proteção , Doses de Radiação , Dosímetros de Radiação , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Fatores de Risco , São Francisco , Espalhamento de Radiação , Adulto Jovem
6.
J Vasc Interv Radiol ; 28(8): 1129-1135.e1, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28457758

RESUMO

PURPOSE: To assess radiation dose reduction during uterine fibroid embolization (UFE) using an optimized angiographic processing and acquisition platform. MATERIALS AND METHODS: Radiation dose data for 70 women (mean age, 46 y; range, 34-67 y) who underwent UFE were retrospectively analyzed. Twenty-one patients underwent UFE using the baseline fluoroscopic and angiographic image acquisition platform, and 49 underwent UFE after implementing an optimized imaging platform in otherwise identical angiography suites. Cumulative kerma-area product (CKAP), cumulative air kerma (CAK), total fluoroscopy time, and image exposure number were collected for each procedure. Image quality was assessed by 3 interventional radiologists blinded to the platform used for image acquisition and processing. RESULTS: Patients undergoing UFE using the new x-ray fluoroscopy platform had significantly lower CKAP and CAK indicators than patients for whom baseline settings were used. Mean CKAP decreased by 60% from 438.5 Gy · cm2 (range, 180.3-1,081.1 Gy · cm2) to 175.2 Gy · cm2 (range, 47.1-757.0 Gy · cm2; P < .0001). Mean CAK decreased by 45% from 2,034.2 mGy (range, 699.3-5,056.0 mGy) to 1,109.8 mGy (range, 256.6-4,513.6 mGy; P = .001). No degradation of image quality was identified through qualitative evaluation. CONCLUSIONS: Significant reduction in patient radiation dose indicators can be achieved with use of an optimized image acquisition and processing platform.


Assuntos
Embolização Terapêutica/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Proteção Radiológica/métodos , Radiografia Intervencionista , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia , Adulto , Idoso , Angiografia Digital , Feminino , Fluoroscopia , Humanos , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
J Vasc Interv Radiol ; 27(11): 1698-1704, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27397617

RESUMO

PURPOSE: To assess safety and efficacy of doxorubicin drug-eluting embolic (DEE) transarterial chemoembolization of hepatocellular carcinoma (HCC) by extrahepatic collateral arteries. MATERIALS AND METHODS: Records of 177 patients with HCC who underwent 338 consecutive DEE chemoembolization procedures from 2011 to 2014 were retrospectively reviewed. A subgroup of 16 patients (13 men, 3 women, median age 66 y) underwent 24 procedures for 17 HCCs via extrahepatic arteries and was included in the study. Median tumor size was 3.1 cm (range, 1.0-10.3 cm). Extrahepatic collaterals included right inferior phrenic (19 procedures; 12 patients), adrenal (4 procedures; 3 patients), and cystic arteries (2 procedures; 2 patients). Radiographic response was assessed by Modified Response Evaluation Criteria in Solid Tumors criteria. Complications were defined by National Cancer Institute Common Terminology Criteria for Adverse Events. RESULTS: DEE chemoembolization achieved stable disease in 6 (35.3%), partial response in 6 (35.3%), and complete response in 4 (23.5%) HCCs. Disease progression was ultimately observed in 8 tumors (47.1%), with mean time to progression of 8.3 months after chemoembolization (range, 2-13 mo). Three minor and 5 major complications occurred in 8 patients; 2 minor complications were rash in vascular distribution after right inferior phrenic artery DEE chemoembolization. The 5 major complications were transient hepatotoxicity that resolved within 4-80 days; 1 was accompanied by pleural effusion requiring hospitalization. A mean 13.4 months after DEE chemoembolization, 67% of transplant candidates proceeded to liver transplant. CONCLUSIONS: DEE transarterial chemoembolization via extrahepatic collaterals was effective and facilitated bridging to transplant. It was generally well tolerated; transient hepatotoxicity was the most common major complication.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Circulação Colateral , Doxorrubicina/administração & dosagem , Circulação Hepática , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/terapia , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Antibióticos Antineoplásicos/efeitos adversos , Carcinoma Hepatocelular/diagnóstico por imagem , Quimioembolização Terapêutica/efeitos adversos , Angiografia por Tomografia Computadorizada , Progressão da Doença , Doxorrubicina/efeitos adversos , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Transplante de Fígado , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
9.
Liver Transpl ; 21(4): 454-67, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25678220

RESUMO

The goal of this study was to determine whether the detection of discordant numbers of hypervascular foci at hepatic angiography versus contrast-enhanced (CE) cross-sectional imaging [computed tomography (CT) or magnetic resonance imaging (MRI)] is associated with adverse clinical outcomes in patients with hepatocellular carcinoma (HCC) who are listed for liver transplantation. We retrospectively reviewed the records of 218 consecutive patients with HCC who were listed for a liver transplant and who underwent transarterial chemoembolization at our institution between January 1, 2006 and December 31, 2010. Patients were grouped into 3 categories: (1) the number of nodules at CT/MRI was concordant with the number of hypervascular foci detected at angiography (n=136), (2) the number of nodules at CT/MRI was greater than the number of hypervascular foci at angiography (n=45), and (3) the number of nodules at CT/MRI was fewer than the number of hypervascular foci at angiography (n=37). The study outcomes were liver transplantation and tumor recurrence after transplantation. The detection of at least 3 more hypervascular foci at angiography versus the number of HCC nodules on CT/MRI was associated with a significantly lower rate of transplantation [multivariate subhazard ratio (SHR), 0.39; 95% confidence interval (CI), 0.17-0.92]. The detection of fewer hypervascular foci at angiography versus the number of HCC nodules on CT/MRI was associated with a significantly higher rate of tumor recurrence after transplantation (multivariate SHR, 3.49; 95% CI, 1.27-9.56). In conclusion, liver transplant candidates with HCC who demonstrate discordant findings between angiography and CE CT or MRI may be at a higher risk for dropout from the transplant list and for tumor recurrence after transplantation.


Assuntos
Angiografia Digital , Carcinoma Hepatocelular/diagnóstico , Técnicas de Apoio para a Decisão , Neoplasias Hepáticas/diagnóstico , Transplante de Fígado , Imageamento por Ressonância Magnética , Seleção de Pacientes , Tomografia Computadorizada por Raios X , Adulto , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Meios de Contraste , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Transplante de Fígado/efeitos adversos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Recidiva Local de Neoplasia , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , São Francisco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
11.
J Vasc Interv Radiol ; 26(9): 1331-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26212556

RESUMO

PURPOSE: To evaluate radiation dose reduction in patients undergoing transarterial chemoembolization with the use of a new image acquisition and processing platform. MATERIALS AND METHODS: Radiation-dose data were obtained from 176 consecutive chemoembolization procedures in 135 patients performed in a single angiography suite. From January 2013 through October 2013, 85 procedures were performed by using our institution's standard fluoroscopic settings. After upgrading the x-ray fluoroscopy system with an image acquisition and processing platform designed to reduce image noise and reduce skin entrance dose, 91 chemoembolization procedures were performed from November 2013 through December 2014. Cumulative dose-area product (CDAP), cumulative air kerma (CAK), and total fluoroscopy time were recorded for each procedure. Image quality was assessed by three interventional radiologists blinded to the x-ray acquisition platform used. RESULTS: Patient radiation dose indicators were significantly lower for chemoembolization procedures performed with the novel imaging platform. Mean CDAP decreased from 3,033.2 dGy·cm(2) (range, 600.3-9,404.1 dGy·cm(2)) to 1,640.1 dGy·cm(2) (range, 278.6-6,779.9 dGy·cm(2); 45.9% reduction; P < .00001). Mean CAK decreased from 1,445.4 mGy (range, 303.6-5,233.7 mGy) to 971.7 mGy (range, 144.2-3,512.0 mGy; 32.8% reduction; P < .0001). A 20.3% increase in mean total fluoroscopy time was noted after upgrading the imaging platform, but blinded analysis of the image quality revealed no significant degradation. CONCLUSIONS: Although a small increase in fluoroscopy time was observed, a significant reduction in patient radiation dose was achieved by using the optimized imaging platform, without image quality degradation.


Assuntos
Angiografia/instrumentação , Quimioembolização Terapêutica/instrumentação , Fluoroscopia/instrumentação , Doses de Radiação , Proteção Radiológica/instrumentação , Radiografia Intervencionista/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
12.
Acta Radiol ; 56(4): 454-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24682403

RESUMO

BACKGROUND: Right adrenal vein (RAV) catheterization can be a very challenging step in adrenal venous sampling (AVS). Visualization of the inferior emissary vein (IEV) may be an indication of successful RAV catheterization. PURPOSE: To compare the rate of successful RAV sampling in the presence of the IEV. MATERIAL AND METHODS: Retrospective review of all consecutive patients with PA who underwent AVS between April 2009 and April 2012 was performed. A total of 30 patients were identified. Procedural images, cortisol, and aldosterone values obtained from sampling of the RAV and inferior vena cava (IVC) were reviewed. Cortisol measurements obtained from RAV samples were divided by measurements from the infra-renal IVC blood samples in order to calculate the selectivity index (SI). An SI >3 was considered indicative of technically successful RAV sampling. RESULTS: RAV sampling was considered technically successful in 29 out of 30 cases (97%). In cases of successful RAV sampling (29 patients), the IEV was identified in 25 patients (86%). The IEV was visualized in isolation in 16 patients (64%), and in conjunction with visualization of the RAV or right adrenal gland stain in nine patients (36%). The IEV was not visualized in the one case of unsuccessful RAV sampling. Visualizing the IEV had a sensitivity of 86.2% for successful RAV sampling. CONCLUSION: The IEV may serve as a reliable landmark for the RAV during RAV sampling.


Assuntos
Glândulas Suprarrenais/irrigação sanguínea , Coleta de Amostras Sanguíneas/métodos , Cateterismo Periférico/métodos , Radiografia Intervencionista/métodos , Veias/anatomia & histologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Hidrocortisona/sangue , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
13.
J Vasc Interv Radiol ; 24(9): 1369-74, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23810309

RESUMO

PURPOSE: To determine clinical outcomes of patients who underwent imaging-guided percutaneous drainage of breast fluid collections after mastectomy and breast reconstruction. MATERIALS AND METHODS: A retrospective review was performed including all consecutive patients who underwent percutaneous drainage of fluid collections after mastectomy with tissue expander-based reconstruction between January 2007 and September 2012. During this period, 879 mastectomies (563 patients) with expander-based breast reconstruction were performed. Fluid collections developed in 28 patients (5%), which led to 30 imaging-guided percutaneous drainage procedures. The median follow-up time was 533 days. Patient characteristics, surgical technique, microbiology analysis, and clinical outcomes were reviewed. RESULTS: The mean age of patients was 51.5 years (range, 30.9-69.4 y), and the median time between breast reconstruction and drainage was 35 days (range, 4-235 d). Erythema and swelling were the most common presenting symptoms. The median volume of fluid evacuated at the time of drain placement was 70 mL. Drains were left in place for a median 14 days (range, 6-34 d). Microorganisms were detected in the fluid in 12 of 30 drainage procedures, with Staphylococcus aureus being the most common microorganism. No further intervention was needed in 21 of 30 drainage procedures (70%). However, surgical intervention (removal of expanders) was needed after 6 (20%) drainage procedures, and additional percutaneous drainage procedures were performed after 3 (10%) drainage procedures. CONCLUSIONS: Percutaneous drainage is an effective means of treating postoperative fluid collections after expander-based breast reconstruction and can obviate the need for repeat surgery in most cases.


Assuntos
Doenças Mamárias/epidemiologia , Doenças Mamárias/cirurgia , Implantes de Mama/estatística & dados numéricos , Drenagem/estatística & dados numéricos , Mastectomia/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Adulto , Idoso , Líquidos Corporais/citologia , Exsudatos e Transudatos/citologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Procedimentos de Cirurgia Plástica/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , São Francisco/epidemiologia , Resultado do Tratamento
14.
Clin Imaging ; 97: 72-77, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36907042

RESUMO

PURPOSE: We sought to identify which aspects of the referring clinician experience are most strongly correlated with overall satisfaction, and hence of greatest relevant importance to referring clinicians. METHODS: A survey instrument assessing referring clinician satisfaction throughout 11 domains of the radiology process map was distributed 2720 clinicians. The survey contained sections assessing each process map domain, with each section including a question about satisfaction overall in that domain and multiple more granular questions. The final question on the survey was overall satisfaction with the department. Univariate logistic regression and multivariate logistic regression were performed to assess the association between individual survey questions and overall satisfaction with the department. RESULTS: 729 referring clinicians (27%) completed the survey. Using univariate logistic regression nearly every question was associated with overall satisfaction. Amongst the 11 domains of the radiology process map multivariate logistic regression identified the following as mostly strongly associated with overall satisfaction: results/reporting overall (odds ratio 4.71; 95% confidence interval 2.15-10.23), section with which work most closely overall (3.39; 1.28-8.64), and inpatient radiology overall (2.39; 1.08-5.08). Other survey questions associated with overall satisfaction on multivariate logistic regression were attending radiologist interactions (odds ratio 3.71; 95% confidence interval 1.54-8.69), timeliness of inpatient radiology results (2.91; 1.01-8.09), technologist interactions (2.15; 0.99-4.40), appointment availability for urgent outpatient studies (2.01; 1.08-3.64), and guidance for selecting correct imaging study (1.88; 1.04-3.34). CONCLUSION: Referring clinicians value most the accuracy of the radiology report and their interactions with attending radiologists, particularly within the section they work most closely.


Assuntos
Radiologia , Humanos , Radiologia/métodos , Radiografia , Diagnóstico por Imagem , Inquéritos e Questionários , Radiologistas
15.
Magn Reson Med ; 67(6): 1747-57, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21956356

RESUMO

The purpose of this study was to test the potential of clinical imaging modalities, 64-slice multidetector computed tomography (MDCT) and 1.5T magnetic resonance imaging (MRI) for qualitative and quantitative evaluation of acute microinfarcts and to determine the effects of <120 µm microemboli on left ventricular function, perfusion, cardiac injury biomarkers, arrhythmia, and cellular and vascular structures. Under X-ray fluoroscopy, 40-120 µm (16 mm(3) ) microemboli were delivered to embolize the left anterior descending (LAD) coronary artery of nine pigs. MDCT/MRI were performed at 72 h in a single session. Microinfarcts were visible in six of nine animals on delayed contrast-enhanced MDCT/MR images but measurable in all animals using semiautomated threshold methods. Other MDCT and MRI sequences demonstrated decline in left ventricular ejection fraction, regional strain and perfusion in visible and invisible microinfarcted regions. Microemboli caused significant elevation in cardiac injury enzymes and arrhythmias. Various sizes of microinfarcts appeared microscopically as distinct aggregates of macrophages replacing myocardium. Semiautomated threshold methods are necessary to measure and confirm/deny the presence of myocardial microinfarcts. This study offers support for alternative applications of MDCT/MRI in assessing clinical cases in which microemboli <120 µm escape protective devices during percutaneous coronary interventions. Although microembolization resulted in no mortality, it caused left ventricular dysfunction, perfusion deficit, cellular damage increase in cardiac injury enzymes, and arrhythmias.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Embolia/diagnóstico , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico , Animais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
16.
Cardiovasc Intervent Radiol ; 44(1): 141-149, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32895782

RESUMO

PURPOSE: To determine the safety and feasibility of pancreatic retrograde venous infusion (PRVI) utilizing a microvalvular infusion system (MVI) to deliver ethiodized oil (lipiodol) by means of the Pressure-Enabled Drug Delivery (PEDD) approach. METHODS: Utilizing transhepatic access, mapping of the pancreatic body and head venous anatomy was performed in 10 swine. PEDD was performed by cannulation of veins in the head (n = 4) and body (n = 10) of the pancreas with a MVI (Surefire® Infusion System (SIS), Surefire Medical, Inc (DBA TriSalus™ Life Sciences)) followed by infusion with lipiodol. Sets of animals were killed either immediately (n = 8) or at 4 days post-PRVI (n = 2). All pancreata were harvested and studied with micro-CT and histology. We also performed three-dimensional volumetric/multiplanar imaging to assess the vascular distribution of lipiodol within the glands. RESULTS: A total of 14 pancreatic veins were successfully infused with an average of 1.7 (0.5-2.0) mL of lipiodol. No notable change in serum chemistries was seen at 4 days. The signal-to-noise ratio (SNR) of lipiodol deposition was statistically increased both within the organ in target relative to non-target pancreatic tissue and compared to extra pancreatic tissue (p < 0.05). Histological evaluation demonstrated no evidence of pancreatic edema or ischemia. CONCLUSIONS: PEDD using the RVI approach for targeted pancreatic infusions is technically feasible and did not result in organ damage in this pilot animal study.


Assuntos
Sistemas de Liberação de Medicamentos , Óleo Etiodado/administração & dosagem , Pâncreas/efeitos dos fármacos , Animais , Antineoplásicos/administração & dosagem , Infusões Intravenosas , Modelos Animais , Pressão , Suínos
18.
J Hepatocell Carcinoma ; 6: 93-103, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31355158

RESUMO

Purpose: To determine whether chemoembolization using drug-eluting beads (DEB-TACE) is safe and effective for liver transplantation candidates with liver-limited hepatocellular carcinoma (HCC) without vascular invasion and baseline hepatic dysfunction. Materials and methods: Seventeen adult liver transplantation candidates (median age 66 years, range 58-73 years; 13 men) with HCC were treated with DEB-TACE as a part of Stage 1 of a prospective single-institution Phase II trial. All patients had marginal hepatic reserve based on at least one of the following criteria: ascites (n=14), bilirubin between 3 and 6 mg/dL (n=5), AST 5-10 times upper normal limit (n=1), INR between 1.6 and 2.5 (n=4), portal vein thrombosis (n=2), and/or portosystemic shunt (n=2). Primary study objectives were safety and best observed radiographic response. Results: Thirty-seven DEB-TACE procedures were performed. Objective response rate and disease control rate were 63% and 88%, respectively. HCC progression was observed in 12 patients. Median time to progression was 5.6 months (range 0.9-13.6 months). Within 1 month following DEB-TACE, 13 patients (76%) developed grade 3 or 4 AE attributable to the procedure. Four patients (all within Milan Criteria) were transplanted (2.7-6.9 months after DEB-TACE), and 12 patients died (1.8-32 months after DEB-TACE). All deaths were due to liver failure that was either unrelated to HCC (n=5), in the setting of metastatic HCC (n=5), or in the setting of locally advanced HCC (n=2). Mortality rate at 1 month was 0%. Conclusions: DEB-TACE achieves tumor responses but carries a high risk of hepatotoxicity for liver transplant candidates with HCC and marginal hepatic reserve.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA