BACKGROUND: The treatment of multiple myeloma (MM) has been revolutionized by the introduction of therapeutic monoclonal antibodies (tmAbs). Daratumumab, a human IgG1/κ tmAb against CD38 on plasma cells, has improved overall survival in refractory MM and was recently approved as a frontline therapy for MM. Work on tmAb interference with serum protein electrophoresis (SPE) during MM monitoring has failed to provide information for laboratories on incidence of interference and effective methods of managing the interference at a practicable level. We aimed to evaluate daratumumab and elotuzumab interference in a large academic hospital setting and implement immediate solutions. METHODS: We identified and chart reviewed all cases of possible daratumumab interference by electrophoretic pattern (120 of 1317 total cases over 3 months). We retrospectively reviewed SPE cases in our laboratory to assess clinical implications of tmAb interference before the laboratory was aware of tmAb treatment. We supplemented samples with daratumumab and elotuzumab to determine the limits of detection and run free light chain analysis. RESULTS: Approximately 9% (120 of 1317) of tested cases have an SPE and/or immunofixation electrophoresis (IFE) pattern consistent with daratumumab, but only approximately 47% (56) of these cases were associated with daratumumab therapy. Presence of daratumumab led to physician misinterpretation of SPE/IFE results. Limits of daratumumab detection varied with total serum gammaglobulin concentrations, but serum free light chain analysis was unaffected. CONCLUSIONS: Clinical laboratories currently rely on interference identification by electrophoretic pattern, which may be insufficient and is inefficient. Critical tools in preventing misinterpretation efficiently include physician education, pharmacy notifications, separate order codes, and interpretive comments.


Assuntos
Anticorpos Monoclonais Humanizados , Anticorpos Monoclonais , Erros de Diagnóstico/prevenção & controle , Cadeias Leves de Imunoglobulina/análise , Mieloma Múltiplo , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/farmacocinética , Anticorpos Monoclonais/uso terapêutico , Anticorpos Monoclonais Humanizados/análise , Anticorpos Monoclonais Humanizados/farmacocinética , Anticorpos Monoclonais Humanizados/uso terapêutico , Eletroforese das Proteínas Sanguíneas/métodos , Humanos , Imunoeletroforese/métodos , Fatores Imunológicos/análise , Fatores Imunológicos/farmacocinética , Fatores Imunológicos/uso terapêutico , Limite de Detecção , Mieloma Múltiplo/sangue , Mieloma Múltiplo/diagnóstico , Mieloma Múltiplo/tratamento farmacológico , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA